How to Identify, Evaluate & Repair Shrinkage Cracks in Poured Concrete



Similar documents
Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Metropolitan Builders Association Masonry & Concrete Standard

PERFORMANCE GUIDELINES

Basement Moisture Problems

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

bout your HOUSE before you start Renovating Your Basement Structural Issues And Soil conditions

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

3 Masonry and Manufactured Stone (Interior and Exterior)

Vision Home Inspection

symptoms of a faulty foundation

WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.

Building Condition Assessment: West Lexington Street Baltimore, Maryland

Designed and Engineered to Perform

PROFESSIONAL ENGINEERING INSPECTIONS, INC.

BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR MARCH 2003 REVISED JUNE 13, 2012

FOUNDATION CRACKS, LEANS, BULGES, SETTLEMENT: INSPECTING FOUNDATIONS FOR STRUCTURAL DEFECTS - DETECTION, DIAGNOSIS, CAUSE, REPAIR

Chapter 2: Foundations

Cold Weather Concrete Practices

Spotting Structural Problems in a Home

HEDDERMAN ENGINEERING, INC. Office , Fax

STRUCTURAL ASSESSMENT

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

MEMORANDUM. General: Foundation:

Building Condition Assessment: North Howard Street Baltimore, Maryland

GOOD NEWS BUT NOT ALWAYS

Chapter 9 Remedial Measures

Chapter 3 Pre-Installation, Foundations and Piers

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

CONDITION OF QUALITY ITEMS

Further Reading Monitoring cracks Contacts Historic Scotland Technical Conservation Group Conclusion

What you need to know about concrete block basement construction.

General Earthquake Damage Inspection Checklist

October 30, Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

Roof Inspection. Summary Report

Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure

Report on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.

bout your HOUSE before you start Repairing And Replacing Materials Exterior Walls

What Causes Foundation Leaking?

Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS

Foundation Water Problems. An Overview and Discussion of some Causes and Cures for Water Infiltration into Basements and Foundation Structures

Sun Windows General Information Sun New Construction Window Installation Instructions

Prevention. Cause. Causes: Groundwater seepage through the basement walls. Prevention: OPEN 24 Hours. Surface runoff. Sanitary sewer backup

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

The minimum reinforcement for the stem wall is the placement of:

14 September Sarah Zorn Planning and Economic Development 25 West Fourth Street, Ste St. Paul, MN 55102

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas August 30, Prepared for:

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

Ron Miedema Cement Contractor 1865 Pine Ridge ~ Jenison, MI 49428

Inspecting to a higher standard.

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

Texas Premier Homes LIMITED BUILDER S WARRANTY COVERAGE

Basement & Foundation Damage

DAMAGE TO FOUNDATIONS FROM EXPANSIVE SOILS

How To Repair A House

PRE-PURCHASE INSPECTION REPORT

Foundation Inspection Methods - Part One By Daniel Friedman

Melbourne balcony Assessments

Commercial Roof Management

May 5, Client Client Address. Re: Inspection Address, Chicago, Illinois. Dear Mr. Client,

INVESTIGATING AND REMEDIATING LEAKS IN BELOW GRADE STRUCTURES AND UNDER PLAZAS

Foundation Repair Fundamentals And how they relate to the Real Estate Industry in the DFW Area

BUILDER LIMITED WARRANTY COVERAGE

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

Get The Picture. page 2. Congratulations on taking your first step toward becoming a basement waterproofing expert!

Waterproofing Problems: A Simple Explanation, A Simple Solution

Elevating Your House. Introduction CHAPTER 5

Bernie Nimer, Dave Seton Mayfair Hotel Development Corporation

PELHAM MEMORIAL HIGH SCHOOL STONE FAÇADE REPORT. November 2007

EAST LYME HIGH SCHOOL

Proposed Minimum Subterranean Termite Treatment Standards

The Ultimate Guide To Protecting Your House From Water In The Basement

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

Building Quality Standards Section

APPENDIX K PIPE INSPECTION

Lighthouse Engineering, L.L.C.

Pre-Drywall Inspection Report

Bituminous Sheet Flat Roofs: Their repair and maintenance

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

Performance Standards INTRODUCTION

Common Problems with Walls

6 RETROFITTING POST & PIER HOUSES

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

MINE SUBSIDENCE CLAIM INVESTIGATION PROCESS

Renovating Your Basement

Basement Window Installation Guide Hopper and Sliding

METHOD STATEMENT 006 TORCH APPLIED MEMBRANE TO BASEMENT WALLS

Water Management & Damage Prevention:

Name of course: Residential Construction Site Management (RCSM) Level 1

Slavic Village Building Condition Review

Waterproofing and interior insulation for basements takes new twist in technology.

Foundation. Foundation

Lighthouse Engineering, L.L.C.

Steve Brinkman Alain Pinel Realtors 167 S San Antonio Road Los Altos, CA RE: Foundation Inspection for 162 Del Monte Ave. Los Altos, CA 94022

Roof Inspection. Summary Report

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Transcription:

How to Identify, Evaluate & Repair Shrinkage Cracks in Poured Concrete What is concrete shrinkage cracking, how and where does it occur? Are concrete floor cracks a structural problem? How to recognize and evaluate shrinkage cracks in poured concrete slabs or floors Do shrinkage cracks in poured concrete always need repair? Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm. This document explains how to recognize shrinkage, evaluate, and repair cracks in poured concrete walls or floors, and discusses a few (minor) possible problems from shrinkage cracking such as water or radon leaks. This forms part of our longer concrete cracking article which describes the types of cracks that occur in poured concrete slabs or floors and explains the risks associated with each, thus assisting in deciding what types of repair may be needed. This website describes how to recognize and diagnose various types of foundation failure or damage, such as foundation cracks, masonry foundation crack patterns, and moving, leaning, bulging, or bowing building foundation walls. Types of foundation cracks, crack patterns, differences in the meaning of cracks in different foundation materials, site conditions, building history, and other evidence of building movement and damage are described to assist in recognizing foundation defects and to help the inspector separate cosmetic or low-risk conditions from those likely to be important and potentially costly to repair. Copyright 2011 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website. Shrinkage Cracks in Poured Concrete Slabs

Shrinkage cracks in poured concrete are easily recognizable and can be distinguished from other types of cracks that occur later in the life of a foundation wall or floor slab. The photograph of cracks above was taken of shrinkage cracks in a concrete slab floor in a home built in 2006. The cracks in this case ranged in width (measured across the crack) from "hairline" (less than 1/16") to about 3/32" in the basement floor slab of this particular home. They may appear larger. What is unique about shrinkage cracks in concrete is that they usually appear to be discontinuous, as shown in this photo. The crack will meander along in the concrete, taper to a stop, and then continue beginning in a parallel line to the first crack, meandering again through the concrete. This is characteristic of concrete (or mud) shrinking while giving up its moisture. You can see the shrinkage of even a perfect concrete floor slab with no visible cracks in the field of its surface if the floor was poured inside of an existing foundation. Look for the gap between the edges of the slab and the foundation wall? Look also for the stains or concrete debris on the wall at the slab level? These confirm that at the time the slab was poured it was touching the wall. Causes of variation in width of shrinkage cracks in poured concrete Why do concrete shrinkage cracks vary in width across a wall or floor? Probably because concrete shrinkage cracks are meandering or "wandering" in their path, and are usually intermittent or interrupted in their course, as you can see in the photograph above. As the path of cracking caused by concrete shrinkage wanders and stops and starts across an area of wall or floor, you will often see overlapping or roughly parallel nearby cracks that represent the end of one crack line and the beginning of another. The total width of the two close-by cracks is probably about the same as the total crack width where a crack wanders in solitary along the concrete. The stresses producing the crack have simply shifted slightly in the wall or floor as it cured. Why cracks appear to originate in poured concrete walls at windows or at outside corners in concrete floor slabs Why do concrete shrinkage cracks often begin near the corner of a window, or in a floor near a corner in the foundation footprint?

If you think of the entire reinforced concrete wall or floor as a rather uniform membrane, any discontinuity in the membrane, such as an opening for a window or the placement of a corner projecting into the room in the case of a floor, creates a variation in the distribution of (shrinkage during curing) forces in the wall or floor. Shrinkage cracks may have their origin at these points of discontinuity. What is the significance of differences in concrete height on opposite sides of a crack? Why are some "shrinkage cracks" at different heights on either side of the crack? The floor on one side of this 3/16" wide crack was about 3/32" higher than on the other. This may be due to settlement of the broken slab section on poorly-compacted fill in the building's basement. Multiple forces and movements may be present as a poured concrete foundation cures, such as a combination of shrinkage and settlement, or shrinkage and outside pressures on a wall from backfill. (It's best to let any masonry wall cure before backfilling, though that's most critical with masonry block (CMU) walls where early backfill before the first floor has been framed in place has been known to lead to a total collapse of the foundation.) In a poured concrete wall or floor if the surface of the concrete on opposite sides of a crack are also at different elevations, that is if the concrete on one side of a crack is higher than the other, additional forces have been at work and the crack is not a simple shrinkage crack. Repair cracks that make trip hazards: If the height difference across a floor crack is 1/8" or more it forms a tripping hazard and it should be repaired. Do we need to repair shrinkage cracks in foundation walls or slabs?

Small shrinkage cracks that are above ground level in a foundation wall, such as the cracks in the inside corner of this poured concrete foundation are unlikely to be much of a problem except for a few less common cases where water running down the wall is leaking in at the shrinkage crack. [Do you think that the crack shown here is an initial footing or foundation settlement crack? Maybe so.] Shrinkage cracks in concrete walls or floor slabs that are leaking into the building interior such as the one shown in this photograph should be sealed. However a careful inspection in this particular case revealed that the window flashing and exterior siding had been installed so as to direct wind-blown rain into a concentrated runoff pattern that [unfortunately] passed over and then through this crack in the foundation wall. Some flashing and siding adjustments outside cured this problem. Concrete cracks often occur at natural stress points where the uniformity of a poured concrete wall or floor has been interrupted by placement of a window (in walls of course) or inside corners (in floors). You may often find shrinkage cracks that trace across the concrete to these stress points. Shrinkage cracks in a concrete slab or floor might need to be repaired to avoid water leakage from below or to stop radon gas entering the building. In the photograph shown here the floor was badly cracked from a combination of concrete shrinkage, settlement, and frost heaves (the building had been left un-heated in a freezing climate).

You can see that lots of water was leaking into the basement up through the floor. In this case, while repairs to the basement floor, or perhaps better, a new basement floor slab, were in order, the root cause of high water levels under the basement floor needed to be addressed first. How are concrete walls, foundation, or floor slab shrinkage cracks avoided or repaired While shrinkage in poured concrete walls or floor slabs is a normal property of curing concrete, shrinkage cracks can be controlled, or where they have occurred, in some cases repairs are needed. In addition to reading about repairing concrete shrinkage cracks (if crack repair is needed at all) at Shrinkage Crack Repairs also see how we prevent shrinkage cracks in poured concrete floors and walls by reading Cracks at Control Joints in Concrete.