Digital Controllers ACTUATOR COMPATABILITY



Similar documents
Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

Model EC5111 Speed Controller Isochronous / Droop

Pow-R-Con Multi Function Control

Basics electronic speed Governor

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Rack mounted telephone- and leased line modem for industrial applications

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

Telephone- and leased line modem for industrial applications TD-36

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

How To Use A Ds340 (Dsp)

Diesel Engine Driven Generators Page 1 of 6

Operation and Calibration Manual. 723PLUS Digital Speed Control for Single Engine Marine Propulsion Applications Manual (Revision B)

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

SELECTION, APPLICATION AND MAINTENANCE

AC3200 INTELLIGENT BROADBAND AMPLIFIER

38 Series - Relay interface modules A

Analog Servo Drive 25A8

IP DSLAM IDL Quick Installation Guide

Product Specification instalert Rapid Messenger Variable Message Sign

723PLUS Digital Speed Control for Reciprocating Engines DSLC Compatible. Installation and Operation Manual , , ,

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Mobile Data Power Model: MDP-25

Ordering Part Numbers:

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

38 Series - Relay interface modules A

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Multi-Protocol decoder with Load regulation

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

EGSTON Standard E2xFxWx 12W

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS


How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Analogue + IVS Electronic Throttle Controls for CUMMINS Engines

The Do s and Don ts of Pressure Transducers

Digital generator set 1302 control kit

White Paper: Electrical Ground Rules

GTEC transfer switch open transition

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Advantium 2 Plus Alarm

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Contents. Document information

PowerStar Mini Triple Play TM

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Copyrights 2010 Victron Energy B.V. All Rights Reserved

Installation and safety instructions for AC/DC built-in devices

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ADACSNET USB Control Module

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

DC Electronic Loads 8500 series

Current Loop Application Note 1495

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Problem / Solution. The problem:

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Duct Humidity Transmitter

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Waveguide Access Point WGA631. Product Guide

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

ST Series POWER SUPPLIES USER INSTRUCTIONS

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Five9NS R2100RS Rack Mount Server. Installation Manual

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit

Measuring Temperature withthermistors a Tutorial David Potter

FOM-5A, 6A. Asynchronous Fiber Optic Modem

UCC 1 USB-CAN CONVERTER

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

HP UPS R1500 Generation 3

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Software Upgrade Instructions for Field Conversion of EGCP-2 Controls: Application Note (Revision NEW, 11/2005) Original Instructions

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

USB-to-Data Highway Plus Cable

Operating Manual UWAPS-TINY Series

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Energy Management Energy Meter Type EM23 DIN

RADIANT PLASMA 4700 Plasma Spark Generator

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

M3-ATX-HV. 6-34V Intelligent ATX Power Supply. Installation Guide Version 1.0c P/N M3-ATX-HV-01

Transcription:

Product Specification 36502B DESCRIPTION APECS DPG-21XX-00X Digital Controllers The DPG-21XX-00X digital controller is used primarily to govern diesel or gas fueled engines of generator sets. This microprocessor-based, digital controller performs across a wide speed range and allows adjustment of set speed and gain parameters with the built-in user interface. The COMM port provides access to all other controller settings, allowing adaptation to each application during service and initial configuration. Separately programmable Proportional, Integral, and Derivative gains are provided for tailoring controller response to many engine applications. Other adjustments include acceleration and deceleration ramp rates, idle speed set, hold time, and more. Properly tuned, this controller delivers fast engine response to speed or load change while providing precise stable isochronous operation. The controller s internal FAILSAFE reacts instantly to loss of the engine speed signal, allowing the actuator to return to minimum fuel. ACTUATOR COMPATABILITY DYNA 2000 DYNA 2500 DYNA 7000 DYNA 70025 DYNA 8000 DYNA 8200 DYNA 8400 DYNA 10141 APECS 0150 APECS 0250 APECS 0300 Power Flow Series Gas Valves APECS Linkage Free Integral Type OTHER MODELS AVAILABLE DPG-2200 Series Load Sharing Generator Applications DPG-2300 Series For Off-Road Applications DPG-2400 Series EFC Valve Applications CALIBRATION TOOL DPG Calibration Kit P/N 8447-1003 Isochronous speed control Precision frequency control: 0.25% Superior temperature stability Reverse battery protection Input voltage range: 9 30 Vdc Smoke control on start up Remote setup Serial communications port

SPECIFICATIONS DPG-21XX-00X controllers are compliant with applicable CE Directives EMC. The controller s main electrical and mechanical specifications are listed here along with several performance characteristics. DPG-21XX-00X Series controllers are available in five hardware configurations. Model No. Connector Style Options 7-wire 12-pin Euro Molex Configurations Speed Sensing Options Magnetic Pickup Ignition Sense Adj. Set Speeds DPG-2101-00X * * 1 + idle DPG-2111-00X * * 1 + idle Remote Speed INC and DEC DPG-2145-00X * * 2 + idle * DPG-2146-00X * * 1 + idle DPG-2155-00X * * 2 + idle * Electrical Operating Voltage Range: 9 30 Vdc * Rated Output Current: Maximum Surge Current: Connections: Input Signal from Magnetic Pickup: Input Signal from Engine s Ignition System: 7 A Maximum (continuous) 14 A (not to exceed ten seconds) Terminal strip with 7 Euro style terminals or a quick connector with 12 pins 2.0 VAC RMS minimum during cranking 40 V minimum during cranking (*) All cabling for these controllers is limited to less than 30m (98.4 ). Power cabling is limited to less than 10m (32.8 ) in total length. See wiring diagrams in User Manual 36526 for specific cable types required. Ambient Operating Temperature: Sealing: Mechanical -40 F to +185 F (-40 C to +85 C) Oil, water, and dust resistant via conformal coating and die cast enclosure Weight: 10 oz. (284 g) Performance Steady State Speed Band: Engine Speed MPU Measurement Range: Governing Speed Rangewith MPU: Engine Speed Ignition Measurement Range: Governing Speed Range with Ignition: ±.25% over ambient operating temperature range 10 MPU Hertz to 14,000 MPU Hertz 500 MPU Hertz to 11,000 MPU Hertz 2 Hertz to 350 Hertz 25 Hertz to 300 Hertz Suggested Mating Connectors for DPG-2145-00X and DPG-2155-00X Models AMP 770581-1 AMP 171637-3 or 794407-3 AMP 90707-1 AMP 408-4137 AMP 189727-1 Mini universal Mate-N-Lock Duplex finish socket Crimping hand tool for 18 gauge wire Crimping documentation Socket extraction tool

PARAMETER REFERENCE The parameter list provides information regarding each of the parameters that can be adjusted when a computer is connected to the controller via the COMM port and Universal PST program. The COMM port and Universal PST are intended only for configuration and periodic service. Do not leave a computer and/or COMM cable connected to the COMM port. The following table lists each of the parameters and their default, minimum, and maximum values. Several of the parameters have minimum and maximum values set by other parameters. Speed and Rate values are shown as Hertz values. PARAMETER LIST FOR DPG-2101-00X (MPU) & DPG-2146-00X (IGNITION) (These controllers use the 7-terminal Euro style screw terminal connector.) PARAMETER NAME DEFAULT MINIMUM MAXIMUM 1. No. of Flywheel Teeth -001 0 0 0 or (Pulses per revolution) -002 0 0 572 Req. 2. Set Speed A 1000 (25) Set Speed A Min Set Speed A Max 3. Not Available 4. Idle Speed 50 (20) Idle Speed Min Idle Speed Max Req. 5. Proportional 25 1 99 Req. 6. Integral 50 0 99 Req. 7. Derivative 25 0 99 Req. 8. OVG @ Set Speed A Use the controller s built-in GAIN potentiometer 9. Not Available 10. OVG @ Idle Speed 20 1 99 Req. 11. Gain Factor 20 (40) 1 99 Req. 12. Speed Filter 16 (4) 1 24 13. Idle Hold Time 0 0 9999 14. Accel Rate 1000 (3000) 1 9999 15. Decel Rate 1000 (3000) 1 9999 16. Startup Rate 1000 (3000) 1 9999 17. Integral Low Limit 0 0 Integral High Limit 18. Integral High Limit 99 Integral Low Limit 99 19. Password 0 0 99-001 100 0 100 20. Over Speed Limit -002 15000 (450) 0 15000 (450) 21. Set Speed A Min 10 (2) 10 (2) Set Speed A 22. Set Speed A Max 11000 (300) Set Speed A 11000 (300) 23. Not Available 24. Not Available 25. Idle Speed Min 10 (2) 10 (2) Idle Speed 26. Idle Speed Max 11000 (300) Idle Speed 11000 (300) 27. Duty Cycle Limit 95 10 95 28. Startup Speed 1000 (25) 10 (2) 11000 (300) 29. Startup Duty Cycle 30 5 95 Req. = Parameter adjustment required to achieve Basic Governing = Parameter use is optional Default, Minimum and Maximum values in parenthesis apply when the controller uses ignition pulses to sense engine speed, which would be the case for a DPG-2146-00X controller.

PARAMETER REFERENCE (Cont d.) The parameter list provides information regarding each of the parameters that can be adjusted when a computer is connected to the controller via the COMM port and Universal PST program. The COMM port and Universal PST are intended only for configuration and periodic service. Do not leave a computer and/or COMM cable connected to the COMM port. The following table lists each of the parameters and their default, minimum, and maximum values. Several of the parameters have minimum and maximum values set by other parameters. Speed and Rate values are shown as Hertz values. PARAMETER LIST FOR DPG-2155-00X (MPU) & DPG-2145-00X (IGNITION) (These controllers use the 12-terminal quick connect.) PARAMETER NAME DEFAULT MINIMUM MAXIMUM 1. No. of Flywheel Teeth -001 0 0 0 or (Pulses per Revolution) -002 0 0 572 Req. 2. Set Speed A 1000 (25) Set Speed A Min Set Speed A Max 3. Set Speed B 1000 (25) Set Speed B Min Set Speed B Max 4. Idle Speed 50 (20) Idle Speed Min Idle Speed Max Req. 5. Proportional 25 1 99 Req. 6. Integral 50 0 99 Req. 7. Derivative 25 0 99 Req. 8. OVG @ Set Speed A Use the controller s built-in GAIN potentiometer 9. OVG @ Set Speed B 20 1 99 10. OVG @ Idle Speed 20 1 99 Req. 11. Gain Factor 20 (40) 1 99 Req. 12. Speed Filter 16 (4) 1 24 13. Idle Hold Time 0 0 9999 14. Accel Rate 1000 (3000) 1 9999 15. Decel Rate 1000 (3000) 1 9999 16. Startup Rate 1000 (3000) 1 9999 17. Integral Low Limit 0 0 Integral High Limit 18. Integral High Limit 99 Integral Low Limit 99 19. Password 0 0 99-001 100 0 100 20. Over Speed Limit -002 15000 (450) 0 15000 (450) 21. Set Speed A Min 10 (2) 10 (2) Set Speed A 22. Set Speed A Max 11000 (300) Set Speed A 11000 (300) 23. Set Speed B Min 10 (2) 10 (2) Set Speed A 24. Set Speed B Max 11000 (300) Set Speed B 11000 (300) 25. Idle Speed Min 10 (2) 10 (2) Idle Speed 26. Idle Speed Max 11000 (300) Idle Speed 11000 (300) 27. Duty Cycle Limit 95 10 95 28. Startup Speed 1000 (25) 10 (2) 11000 (300) 29. Startup Duty Cycle 30 5 95 Req. = Parameter adjustment required to achieve Basic Governing = Parameter use is optional Default, Minimum and Maximum values in parenthesis apply when the controller uses ignition pulses to sense engine speed, which would be the case for a DPG-2145-00X controller.

PARAMETER REFERENCE (Cont d.) The parameter list provides information regarding each of the parameters that can be adjusted when a computer is connected to the controller via the COMM port and Universal PST program. The COMM port and Universal PST are intended only for configuration and periodic service. Do not leave a computer and/or COMM cable connected to the COMM port. The following table lists each of the parameters and their default, minimum, and maximum values. Several of the parameters have minimum and maximum values set by other parameters. Speed and Rate values are shown as Hertz values. PARAMETER LIST FOR DPG-2111-00X (These controllers use the 7-terminal Euro style screw terminal connector.) PARAMETER NAME DEFAULT MINIMUM MAXIMUM 1. No. of Flywheel Teeth or (Pulses per Revolution) -001 0 0 0-002 0 0 572 Req. 2. Set Speed A 1000 Set Speed A Min Set Speed A Max 3. Not Available 4. Idle Speed 50 Idle Speed Min Idle Speed Max Req. 5. Proportional 25 1 99 Req. 6. Integral 50 0 99 Req. 7. Derivative 25 0 99 20 1 99 Req. 8. OVG @ Set Speed A The controller s built-in GAIN ADJUST potentiometer provides a +/-20% adjustment range of the nominal gain value entered. 9. Not Available 10. OVG @ Idle Speed 20 1 99 Req. 11. Gain Factor 20 1 99 Req. 12. Speed Filter 16 1 24 13. Idle Hold Time 0 0 9999 14. Accel Rate 1000 1 9999 15. Decel Rate 1000 1 9999 16. Startup Rate 1000 1 9999 17. Integral Low Limit 0 0 Integral High Limit 18. Integral High Limit 99 Integral Low Limit 99 19. Password 0 0 99-001 100 0 100 20. Over Speed Limit -002 15000 0 15000 21. Set Speed A Min 10 10 Set Speed A 22. Set Speed A Max 11000 Set Speed A 11000 23. Not Available 24. Not Available 25. Idle Speed Min 10 10 Idle Speed 26. Idle Speed Max 11000 Idle Speed 11000 27. Duty Cycle Limit 95 10 95 28. Startup Speed 1000 10 11000 29. Startup Duty Cycle 30 5 95 Req. = Parameter adjustment required to achieve Basic Governing = Parameter use is optional

PO Box 1519 Fort Collins CO, USA 80522-1519 1000 East Drake Road Fort Collins CO 80525 Ph: +1 (970) 482-5811 Fax: +1 (970) 498-3058 EUROPEAN COMPLIANCE FOR CE MARKING EMC DIRECTIVE Declared to 89/336/EEC COUNCIL DIRECTIVE of 03 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility. See the Declaration of Conformity in User Manual 36526. Distributors & Service Woodward has an international network of distributors and service facilities. For your nearest representative, call the Fort Collins plant or see the Worldwide Directory on our website. Corporate Headquarters Rockford IL, USA Ph: +1 (815) 877-7441 www.woodward.com EMC LIMITATIONS Cabling All cabling for this unit is limited to less than 30m (98.4 ). Power cabling is limited to less than 10m (32.8 ) in total length from its source; power is intended to be from a local bus structure. The control is not intended to have a power bus that is derived from a plant-wide distribution system, remote source, or similar mains type distribution systems. The power to the control should also be a dedicated circuit, directly to the battery or source via a power and return wire that are routed together. See User Manual 36526 for additional regulatory information, limitations, and wiring diagrams with specific, required cable types. Power Bus The power bus is intended to be a local bus and to have inductive load kickback events suppressed. Therefore, the control s power input is not designed to withstand a charging system load dump, heavy inductive kickbacks, or heavy surge type pulses. If the control is installed outside its intended usage, as described in this manual, centralized voltage pulse suppression should be implemented to protect the control and other components on the bus. (See the installation instructions in User Manual 36526.) COMM Port The COMM port is intended to be a service port, with only temporary connection during service or initial configuration. The COMM port is susceptible to some EMC phenomena and possible unintentional battery return currents. 1. Battery return (B-) is also the communication signal common; typically PCs connect the communication signal s common to protective earth. The PC grounding can provide an unintended return path for B- currents. If B- and the PC are grounded to protective earth, a communication isolator should be used between the PC and the control. Damage to the PC or control, and/or unintended operation may result from a broken battery return wire or the parallel path. 2. The pins inside the COMM port plug are susceptible to damage by ESD discharges, static electricity arcs. Care should be taken not to touch them with tools or put fingers into the port. Always touch your hand or tool to a grounded piece of metal (discharge ESD) before coming in contact with the COMM port. 3. The input is susceptible to RF noise such as switching transients and transmitter signals coupled into the communication cable. Cable orientation and short cable length may be used to eliminate these issues, depending on the severity of the environment. RELATED DOCUMENTATION This document is distributed for informational purposes only. It is not to be construed as creating or becoming part of any Woodward Governor Company contractual or warranty obligation unless expressly stated in a written sales contract. User Manual 36526 For more information contact: Woodward 2006 All Rights Reserved 06/03/M