NEW SCIENCE FIRE SAFETY ARTICLE INNOVATING FIRE ATTACK TACTICS SUMMER 2013 UL.COM/NEWSCIENCE



Similar documents
SOUTH LYON FIRE DEPARTMENT Manual of Procedures 404

Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases

Flashover. Newsletter by Vincent Dunn-July 2000

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference?

Manchaca Fire / Rescue Probationary Firefighter Academy. Salvage and Overhaul. SFFMA Section 5: Salvage and Overhaul

Firefighter Review. Instructor Guide

Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers

Fire Safety Risk Assessment Checklist for Residential Care Premises

Building Code Clarifications - 7. Fire Resistance

How To Build A Basement House

FIREFIGHTER & OCCUPANT SAFETY CONSIDERATIONS WITH MODERN LIGHTWEIGHT CONSTRUCTION.

STATE FIRE MARSHAL'S OFFICE

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

St. John s University

BUILDING PERMIT SPECIFICATIONS

NFPA Fire Fighter II

Decree of the Ministry of the Environment. on fire safety of garages

Death in the line of duty

Recommended Best Practices For Fire Department Training Programs

Fire-Rated Glass and Glazing START

Integrated Solar Radiant Systems

Fire Development and Fire Behavior Indicators

1402 Hybrid Firefighter I. Course Orientation Guide (Rev 1)

OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety

FIRE SAFETY FOR OFFICE WORKERS

The replacement or modification of existing windows shall comply with the following requirements:

Truck Company Operations

Using Class B Combustibles During Live Fire Training

FATAL TRAINING FIRES: FIRE ANALYSIS FOR THE FIRE SERVICE

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

WHAT YOU NEED TO KNOW ABOUT INSURING A HOME WITH FIRE SPRINKLERS

Reducing Injury and Damage Related to Electric Dryer Fires. Fire Containment Tests for the Second Edition of UL 2158

Factors to Consider When Developing an Evacuation Plan

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

LESSON PLAN FIRE PREVENTION AND SAFETY

city of edmonds development information

Live Fire Training Solutions Firefighter training that could save your life

Smoke & Carbon Monoxide

Use Of Residential Fire Sprinklers In New Housing Projects

FIRE INVESTIGATOR LEAD EVALUATOR HANDBOOK

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

FLA S FIRE SAFETY INITIATIVE

Building Condition Assessment Report

Development Services City of Lawrence, KS

PROFESSIONAL ENGINEERING INSPECTIONS, INC.

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Tank Farm and Bulk Storage Fire Incidents

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Strategy & Tactics FST 202. COURSE SYLLABUS Strategy & Tactics FST 202 [Semester] CRN 3 Credits

Fire Sprinkler Fact Sheet

PROTECT WHAT YOU VALUE MOST

FIREFIGHTER SAFETY. Stay safe during substation fires

CERTIFICATE OF COMPLIANCE

UFF Position Statement: Fire and Smoke as a Weapon

Single Family Residential Basement Finish

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

Estimated Cost of Repair

Bus Fire Safety in China. James Wang China Bus & Coach Yearbook

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

The Tools Firefighters Use

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

Wyoming State Capitol Building Restoration and Modernization

Get Alarmed, Tennessee! Smoke Alarm Program Saves

HAMILTON SCHOOL Brentwood Parkway, N.E., Washington, DC INITIAL YEAR BUILT 1968 BUILDING AREA

Related KidsHealth Links

2010 edition. Handbook of. Fire-Rated Glass. for schools

Chapter 2: Foundations

U.S. FIRE SERVICE FATALITIES IN STRUCTURE FIRES,

Elevating Your House. Introduction CHAPTER 5

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

How To Make A House Safe

Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

Fire Safety Requirements for Child Care Centre

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

Fundamentals of Motor Vehicle Fire Investigation

29 Broadway- 14 th Fl Tel: New York NY Fax: Due Diligence Report. New York, New York

Rules of Engagement for Structural Firefighting

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Fire Ground Leader Guide to Certification. FIRE CERTIFICATION PROGRAM, DPSST 4190 Aumsville Hwy. SE Phone Fax

English Victorian Semi-Detached House Fire.

EMERGENCY EVACUATION PLAN FOR LIFE AND FIRE SAFETY

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.

October 30, Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

IAPE STANDARDS SECTION 5 FACILITIES

Risk Assessment Form. Compliant to NFPA 1851 (2014 edition)

GENERIC RISK ASSESSMENT 3.6 FIGHTING FIRES - USING POSITIVE PRESSURE VENTILATION

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM ENGINE COMPANY SKILLS 1 ¾ RESIDENTIAL ATTACK LINES

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Transcription:

NEW SCIENCE FIRE SAFETY ARTICLE INNOVATING FIRE ATTACK TACTICS SUMMER 2013 UL.COM/NEWSCIENCE

NEW SCIENCE FIRE SAFETY OVERVIEW UL s dedicated team of scientists, engineers and researchers is creating New Science in a variety of ways. From live experiments to computational modeling, statistical analysis to quantification of risk, we are constantly seeking to improve products, techniques, methodologies, processes and standards. 2

WHY INNOVATIVE FIRE ATTACK TACTICS MATTER Firefighters are being challenged by different fireground hazards due to today s more open floor plans and the use of synthetic materials in furniture and building products. 1 These changes have made structure fires more deadly than ever before and call into question traditional firefighting tactics. Innovative fire attack tactics matter because, although they may go against traditional practices, they represent a more effective way to make the fireground safer for both building occupants and firefighters. CONTEXT The changes in modern building design and materials have altered the nature of structure fires, with modern homes able to reach flashover eight times faster than homes built 50 years ago. 2 This change is largely behind the 67% increase over the past 30 years in the rate of firefighter deaths due to traumatic injuries while operating inside structures. 3 And although the overall fire death rate in the U.S. has decreased by 64% during the same period, 4 it is clear that modern structure fires can be deadly to both firefighters and building occupants. Many of the tactics employed by the American fire service have been developed based on personal experience of individual firefighters and as passed down by their predecessors. 5 To the credit of many of these firefighters, their tactics have proven successful in controlling and mitigating the hazards of fire for more than 250 years. 6 However, the number of structure fires has decreased by 53% over the past 30 years, 7 which has had an unintended consequence of limiting the opportunities for firefighters and fire officers to gain the necessary experience to understand the increasingly complex fires they fight. 8 One common practice was for firefighters to fight fires exclusively from inside a burning building during search and rescue efforts. 9 There was a widely held belief supported by anecdotal evidence that attacking a fire with water from outside the building would push the fire further into the structure, making conditions beyond the fire worse and potentially increasing the risk to firefighters and trapped victims. 10 Because of this, the firefighters who were first on the scene would typically pull a fire hose with them as they searched room-by-room for victims while the fire blazed and their colleagues watched outside and waited for them to emerge. 11 3

Given these developments, UL saw a clear need for new insights about fire progression, fire behavior and what happens to the structural integrity of a building under fire conditions. UL also saw a need for improved firefighting tactics that would enable modern structure fires to be fought FIRE more SAFETY effectively JOURNAL while improving firefighter safety and building occupant survivability. 12 UL used two homes to test a variety of experimental scenarios, including a number of innovative exterior WHAT DID UL DO? attack tactics. UL conducted two sets of full-scale, live-fire experiments to demystify the modern fireground specifically, to better understand modern fire conditions and to evaluate the effectiveness of traditional and new firefighting tactics. 13 The first set of live-fire experiments were staged in two houses constructed in UL s large fire facility in Northbrook, IL. 14 These experiments were conducted under the United States Department of Homeland Security (DHS) Assistance to Firefighter Grant Program. 15 One of the houses had one story (1,200 ft 2, three bedrooms, one bathroom), with a total of eight rooms. The second house had two stories (3,200 ft 2, four bedrooms, two and a half bathrooms) and had a total of 12 rooms, a modern open floor plan, a two-story great room and an open foyer. A total of 17 full-scale residential structure fire experiments were conducted in the two houses to examine different ventilation scenarios and a variety of tactics, including controlling the front door, making different sized ventilation holes in the roof and using exterior hose streams. 16 UL conducted two sets of full-scale, live-fire experiments to test a number of innovative fire attack tactics. The second set of live-fire experiments were funded by the Fire Department of New York (FDNY) and carried out in partnership with the FDNY and the National Institute of Standards and Technology (NIST). The experiments 17 were conducted on a series of unoccupied homes on Governors Island. The structures were two-story townhouses with full basements, approximately 800 square feet per floor, concrete block walls, brick exterior, and wood-framed interior walls and flooring systems. The fuel load included real furniture of common construction wood frame, polyurethane foam, polyester batting and fabric to simulate current hazards. The furniture was consistent from home to home to enable comparison between experiments. All of the Governors Island experiments were also consistent with the previous room-and-contents fire experiments conducted by NIST and UL. These experiments resulted in ventilationlimited (fuel-rich) fires. UL used these homes to test a variety of experimental scenarios, including a number of innovative exterior attack tactics. The exterior attack is an offensive approach analogous to the military concept of softening the target that requires an aggressive attack just prior to entry, search and tactical ventilation. 18 UL benchmarked the exterior attack against a traditional offensive attack that is initiated by deploying 4

hoselines inside the structure directly at the seat of the fire. 19 The UL experiments showed that the traditional approach is not always the best. Several experiments were conducted in homes with different fire conditions. In one example, in a two-story house, fire was showing from a second floor window: Traditional tactics call for the hoseline to be charged in the front of the house prior to entry, but water is usually not flowed onto the fire prior to entry. Even if the interior path to the fire is known, flowing water directly onto the fire is faster from the outside than it is from the inside In this experiment, temperatures were measured in the hallway just outside the room and in the other bedrooms on the second floor. Twenty-five gallons of water directed off of the ceiling of the fire room from the exterior decreased fire room temperatures from 1,792 degrees F to 632 degrees F in 10 seconds; the hallway temperature decreased from 273 degrees F to 104 degrees F in 10 seconds. 20 The key findings of our experiments show that the common belief about exterior fire attack pushing the fire is unfounded and that innovative fire attack tactics can improve the safety and effectiveness of firefighting efforts: Applying water directly into the fire compartment as soon as possible results in the most effective means of suppressing the fire. 23 Water applied via exterior attack does not push the fire. 21 The anecdotal experience of firefighters can be explained by one of the following scenarios: 1) A flow path is changed with ventilation and not with water application. 2) A flow path is changed with water when the thermal layer is disrupted and steam moves ahead of the line, elevating the level of heat and creating the impression to those downstream that the fire is being pushed. 3) Turnout gear becomes saturated with energy, which begins to pass through to the firefighter. If this occurs in close proximity to when a hoseline is opened, it might appear that the hoseline caused the rapid buildup of heat. 4) One room is extinguished, allowing air to entrain into another room, which causes that room to ignite, burn more intensely or reach flashover. 22 Rather than making conditions more hazardous, applying water directly into the fire compartment as soon as possible results in the most effective means of suppressing the fire. 23 Specifically, our research showed that applying a hose stream through a window or door into a room involved in a fire significantly lowered room temperatures everywhere in the home. Even a small amount of water, applied as quickly as possible regardless of where it is from, improved conditions inside the burning home. And in cases where front and rear doors were open and windows had been vented, the application of water through one of the vents enhanced conditions throughout the structure. 5

Our experiments showed that exterior fire attack increases the potential survival time for building occupants and provides safer conditions for firefighters performing search and rescue. In fact, our experiments demonstrated that the traditional practice of increasing ventilation to a ventilation-limited structure fire by opening doors, clearing windows or cutting the roof increased fire hazards and the potential for a rapid transition to flashover. 24 While the attack should be commenced from the exterior, to improve conditions for firefighters and building occupants, it must be finished inside. Applying water to the fire as soon as possible from the outside softens the target and helps firefighters gain the upper hand, but the attack and size-up should be continued from inside the home. Once conditions inside the structure are made safer, continuing the attack from the inside increases the speed and effectiveness of fully extinguishing the fire. 25 UL conducted full-scale, live-fire experiments to better understand modern fire conditions. IMPACT The UL research provided an enhanced understanding of fire behavior in structures and demonstrated the viability of innovative attack tactics. UL is now working to spread the word to transform the way firefighters think about and approach structure fires. UL is presenting the data from the experiments to the Fire Department Instructors Conference and Fire Rescue International. UL is also sharing the data with the International Society of Fire Service Instructors, the International Fire Service Training Association and the National Fire Protection Association. 26 In this way, the innovative tactics tested in UL s live-fire experiments will help ensure that firefighters around the world more safely and effectively fight modern structure fires. 6

SOURCES 1 Comparison of Modern and Legacy Home Furnishings, UL, 2010. Web: 20 July 2013. https://www.ul.com/room_fire/room_fire.html. 2 Ibid. 3 Fahy, R., Ph.D., U.S. Fire Service Fatalities in Structure Fires, 1977-2009, National Fire Protection Association, June 2010. Web: 20 July 2013. http:// paramountalarm.info/2010-nfpa-us-fatalities-in-structures.pdf. 4 Fire Death Rate Trends: An International Perspective, U.S. Fire Administration, July 2011, Volume 12, Issue 8. Web: 16 July 2013. http://www.usfa.fema.gov/downloads/pdf/statistics/v12i8.pdf. 5 Kerber, S., and Sendelbach, T.E., What Research Tells Us about the Modern Fireground, FirefighterNation, 06 June 2013. Web: 19 July 2013. http://www. firefighternation.com/article/strategy-and-tactics/what-research-tells-usabout-modern-fireground. 6 Ibid. 7 Fahy, R., Ph.D., U.S. Fire Service Fatalities in Structure Fires, 1977-2009, National Fire Protection Association, June 2010. Web: 20 July 2013. http:// paramountalarm.info/2010-nfpa-us-fatalities-in-structures.pdf. 8 Kerber, S., Examination of the Impact of Ventilation and Exterior Suppression Tactics on Residential Fires, UL, NIST and the Fire Department of the City of New York, July 2012. 9 Kerber, S., Study of the Effectiveness of Fire Service Vertical Ventilation and Suppression Tactics in Single Family Homes, UL, 15 June 2013. Web: 29 July 2013. http://ulfirefightersafety.com/wp-content/uploads/2013/06/ul-fsri- 2010-DHS-Report_Comp.pdf. 10 Ibid. 11 Ibid. 12 Kerber, S., Examination of the Impact of Ventilation and Exterior Suppression Tactics on Residential Fires, UL, NIST and the Fire Department of the City of New York, July 2012. 13 Kerber, S., and Sendelbach, T.E., What Research Tells Us about the Modern Fireground, FirefighterNation, 06 June 2013. Web: 19 July 2013. http://www. firefighternation.com/article/strategy-and-tactics/what-research-tells-usabout-modern-fireground. 14 Kerber, S., Study of the Effectiveness of Fire Service Vertical Ventilation and Suppression Tactics in Single Family Homes, UL, 15 June 2013. Web: 29 July 2013. http://ulfirefightersafety.com/wp-content/uploads/2013/06/ul-fsri- 2010-DHS-Report_Comp.pdf. 15 Ibid. 16 Ibid. 17 Kerber, S., Examination of the Impact of Ventilation and Exterior Suppression Tactics on Residential Fires, UL, NIST and the Fire Department of the City of New York, July 2012. 18 Ibid. 19 Ibid. 20 Kerber, S., and Sendelbach, T.E., What Research Tells Us about the Modern Fireground, FirefighterNation, 06 June 2013. Web: 19 July 2013. http://www. firefighternation.com/article/strategy-and-tactics/what-research-tells-usabout-modern-fireground. 21 Kerber, S., Study of the Effectiveness of Fire Service Vertical Ventilation and Suppression Tactics in Single Family Homes, UL, 15 June 2013. Web: 29 July 2013. http://ulfirefightersafety.com/wp-content/uploads/2013/06/ul-fsri- 2010-DHS-Report_Comp.pdf. 22 Ibid. 23 Kerber, S., Examination of the Impact of Ventilation and Exterior Suppression Tactics on Residential Fires, UL, NIST and the Fire Department of the City of New York, July 2012. 24 Ibid. 25 Ibid. 26 Ibid. NEW SCIENCE FIRE SAFETY JOURNALS JOURNAL ISSUE 1 JOURNAL ISSUE 2 PV PANELS WIRELESS CHARGING OF ELECTRIC VEHICLES REDEFINING SMOKE ADVANCED COMPUTER MODELING LITHIUM-ION BATTERIES STATISTICALLY PREDICTING ELECTRICAL ARCING MODERN RESIDENTIAL FIRES NEW DYNAMICS OF BASEMENT FIRES 7

To learn more, explore the New Science of Indoor Air Quality, Transaction Security, Sustainable Energy and Fire Safety. Watch our videos; read our journals, articles and case studies; scroll through our galleries; and meet our experts. VISIT US ON UL.COM/NEWSCIENCE NEWSCIENCE@UL.COM +1 847.664.2040 New Science Fire Safety cannot be copied, reproduced, distributed or displayed without UL s express written permission. V.19. UL and the UL logo are trademarks of UL LLC 2013