Power network telecommunication



Similar documents
Power network telecommunication

Universal power line carrier

Communications network solutions for smart grids Answers for infrastructure & cities.

Teleprotection Schemes and Equipment. James W. Ebrecht Young Power Equipment Scottsdale, AZ

WAN Technology. Heng Sovannarith

Telecommunications, Networks, and Wireless Computing

Fundamentals of Telecommunications

EECC694 - Shaaban. Transmission Channel

Efficient remote access to machines and plants with SIMATIC

BROADBAND AND HIGH SPEED NETWORKS

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

TI 313 (1.0 EN) d&b Remote network - Integration

Course 12 Synchronous transmission multiplexing systems used in digital telephone networks

Broadband 101: Installation and Testing

White Paper: Voice Over IP Networks

PLCs and SCADA Systems

R2. The word protocol is often used to describe diplomatic relations. How does Wikipedia describe diplomatic protocol?

Monitoring and diagnostics

Computer Network. Interconnected collection of autonomous computers that are able to exchange information

FlexCON VoIP. Industrial VoIP GW and Serial Converter. FXO, FXS, VF, Serial Industrial VoIP Ddd. Ethernet. Features

Analog vs. Digital Transmission

Chapter 2 - The TCP/IP and OSI Networking Models

Connection Services. Hakim S. ADICHE, MSc

Computer Networks. Definition of LAN. Connection of Network. Key Points of LAN. Lecture 06 Connecting Networks

NX 64 Digital Radio Link

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

Starlink 9003T1 T1/E1 Dig i tal Trans mis sion Sys tem

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Chapter 11: WAN. Abdullah Konak School of Information Sciences and Technology Penn State Berks. Wide Area Networks (WAN)

Chapter 7: Computer Networks, the Internet, and the World Wide Web. Invitation to Computer Science, C++ Version, Third Edition

Wireless Technologies for the 450 MHz band

How To Understand The Technical Specifications Of Videoconferencing

ABB RTU560A Series CMU & Modules

AP200 VoIP Gateway Series Design Features & Concept AddPac R&D Center

TCP/IP Network Communication in Physical Access Control

FibeAir I500R High Capacity Wireless Network Solution

WANs connect remote sites. Connection requirements vary depending on user requirements, cost, and availability.

Wharf T&T Limited Report of Wireless LAN Technology Trial Version: 1.0 Date: 26 Jan Wharf T&T Limited. Version: 1.0 Date: 26 January 2004

This course has been retired. View the schedule of current <a href=

(Refer Slide Time: 2:10)

NXU RoIP Link to Eliminate Voice-Grade Leased Line

How To Build A Network For Mining

Think! Think! Data communications. Long-Distance. Modems: to analog and back. Transmission Media. The last mile is the hardest for digital information

Performance Measurements on Power Line Carrier Data Transmissions in Indoor Office Environments

Endless possibilities

Course 1. General view on the fixed telephone network. Digital networks. General aspects. Definitions.

- T-Carrier Technologies -

ADSL or Asymmetric Digital Subscriber Line. Backbone. Bandwidth. Bit. Bits Per Second or bps

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

Network+ Guide to Networks 6 th Edition. Chapter 7 Wide Area Networks

Complete Power-Line Narrow Band System for Urban- Wide Communication

Communication Networks. We are securing the past in a fast moving future. FOX605 multiservice platform.

How To Set Up An Ip Trunk For A Business

emobility WAGO Leading the Charge

1.264 Lecture 32. Telecom: Basic technology. Next class: Green chapter 4, 6, 7, 10. Exercise due before class

Failsafe Protection for Utility Critical Infrastructure

Siemens ENEAS solutions for substation automation and protection

Multiplexing. Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single physical medium.

Smart Solutions for Network IP Migration

Xpress2500 Access System

TCOM 370 NOTES 99-6 VOICE DIGITIZATION AND VOICE/DATA INTEGRATION

IP/MPLS. Marios Parperis - Alcatel-Lucent Energy Systems Integration Division. October Alcatel-Lucent 2010 All Rights Reserved

/ gridsecurity Cyber Security Global solutions for energy automation Answers for infrastructure and cities.

CHAPTER 8 MULTIPLEXING

Utility Communications FOXMAN-UN Network Management System for ABB Communication Equipment

Carrier Ethernet: New Game Plan for Media Converters

Packet Synchronization in Cellular Backhaul Networks By Patrick Diamond, PhD, Semtech Corporation

Octal T1-10/100 RIOP Installation Guide

Failsafe WAN, VoIP, IVRS & LAN connectivity

Application Note License-Exempt Gigabit Ethernet Microwave Radio Applications

LEASED-LINE REPLACEMENT

Chapter 6 Bandwidth Utilization: Multiplexing and Spreading 6.1

WAN. Introduction. Services used by WAN. Circuit Switched Services. Architecture of Switch Services

R-Win. Smart Wireless Communication Management System

NEW WORLD TELECOMMUNICATIONS LIMITED. 2 nd Trial Test Report on 3.5GHz Broadband Wireless Access Technology

White Paper. OPCOM3500 Multi-Service Access Platform INTRODUCTION CHARACTERISTICS

Next Generation of High Speed. Modems8

Performance Management and Fault Management. 1 Dept. of ECE, SRM University

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

IT4405 Computer Networks (Compulsory)

Telephone Company Lease Line Elimination. Dewey Day Principal Operational Technology Architect Pacific Gas & Electric

T1 Networking Made Easy

Introduction To SCADA and Telemetry

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

Transporting Legacy Switched Digital Circuits Using a Packet Network

Voice and Delivery Data Networks

Attenuation (amplitude of the wave loses strength thereby the signal power) Refraction Reflection Shadowing Scattering Diffraction

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

WAN Data Link Protocols

IT Data Communication and Networks (Optional)

Network administrators must be aware that delay exists, and then design their network to bring end-to-end delay within acceptable limits.

Telecommunications systems (Part 1)

Alcatel-Lucent 1645 AMC Access Mutiplexer Compact. Cost-effective and compact STM-1/4 multiservice metro access

AMETEK s New Broadband FOCUS:

How To Extend A Cell Phone Over Wireless To A Long Distance Over A Cell Tower

White Paper. D-Link International Tel: (65) , Fax: (65) Web:

White Paper: Broadband Bonding with Truffle PART I - Single Office Setups

Video Conferencing Glossary of Terms

ATA: An Analogue Telephone Adapter is used to connect a standard telephone to a high-speed modem to facilitate VoIP and/or calls over the Internet.

Transcription:

www.siemens.com Power network telecommunication PowerLink power line carrier system Answers for infrastructure and cities.

Power line carrier always up-to-date A few years ago, it was looking as if digital fiber-optic networks would replace the traditional PLC (power line carrier) systems at power supply utilities. As it turns out, however, PLC is still an indispensable communication alternative for numerous applications and will remain so in the future: This technology ensures extremely high standards of communication in network protection, and can easily be integrated into a wide range of communication networks, as in the case of the Siemens PowerLink PLC system. Perfect matching to modern communication environments, along with built-in technical potential for the requirements of the future, make PLC systems more attractive today than ever before. PowerLink the versatile solution PowerLink uses the high-voltage line between transformer substations as a communication path for data, protection signals, and voice. This technology, which has been tried and tested over decades and adapted to the latest standards, has two main application areas: as a communications link between substations where a fiber-optic connection does not exist or would not be economically viable, and as a backup system for transmitting protection signals parallel to an installed fiber-optic link. A basic distinction is made between analog (aplc) and digital (dplc) systems. Newer digital systems allow more efficient use of the frequency band, while traditional analog PLC systems offer advantages in cases where transmission conditions are less favorable (low signal/noise ratio, for example). With PowerLink, both operating modes are open to you. You can even combine aplc and dplc services in a single communications network. Advantages at a glance: Cost-effective for small to medium data volumes over long distances Processes analog and digital signals Dynamic transmission rate Adjustable transmission power Variable bandwidth Transmission capacity up to 320 kbps Integrated TCP/IP interface Voice compression Versatile multiplexer Integrated teleprotection systems Cross-functional management system for all integrated services Can be used effectively in combination with broadband technologies for optimal availability 2

CFS-2 VF VFO VFS 8 x VFM VF A D fe1 X21-1 X21-2 TCP/IP G703.1 RS 232 8 x RS 232 iswt 1 iswt 2 MUX CSP DSP system DP D A D A AMP 50 AMP 50 AGC ATT RXF PLPA TXF TXF LT 100 DSP Digital signal processing VF Voice frequency VFO Voice frequency interface FXO VFS Voice frequency interface FXS VFM Voice frequency interface E & M X.21-x Synchronous digital interface RS 232 Asynchronous digital interface iswt Integrated SWT 3000 Versatile multiplexer ifsk Integrated FSK channel DP Data pump AGC Automatic gain control ATT Attenuator FE1 Fractional E1 2 Mbps CFS-2 Carrier frequency section PLPA PowerLink power amplifier CSP Central signal processor unit AMP 50 50-W power amplifier RXF Receive filter TXF Transmit filter TCP/IP LAN interface High performance Easy to manage PowerLink offers a transmission capacity of 320 kbps and an integrated TCP/IP interface. This means that many different types of IP terminals can use the power line communications network effectively. PowerLink not only simplifies communications, it also makes communications cost-effective. The PowerSys software administers all of PowerLink s integrated applications under a standard user interface. This ensures higher oper ating security while keeping training time and costs to a minimum. 3

Features Universally applicable in analog, digital, or mixed operation Digital PLC system Analog PLC system Frequency range 24 khz 1,000 khz Bandwidth selectable 2 32 khz Data rate up to 320 kbps @ 32 khz Transmission power 20/50/100 W, fine adjustment through software Operation with or without frequency band spacing with automatic cross talk canceller Digital interface Synchronous X.21 (max. 2 channels) Asynchronous RS 232 (max. 8 channels) TCP/IP (2 x electrical, 1 x optical) E1 (2 Mbps) for voice compression G703.1 (64 kbps) Analog interface VF (VFM, VFO, VFS), max. 8 channels for voice, data, and protection signal Asynchronous RS232 (max. 4) via FSK Miscellaneous Adaptive dynamic data rate adjustment TCP/IP layer 2 bridge Integrated versatile multiplexer for voice and data Max. 5 compressed voice channels via VF interface Max. 8 voice channels via E1 interface StationLink bus for the cross-connection of max. 4 PLC transmission routes (compressed voice and data without voice compression on repeater) Reverse FSK analog /modem data via dplc (2 x) Protection signal transmission system SWT 3000 Integration of two devices Remote operation via cable or fiber-optic cable identical to the integrated version Single-purpose or multipurpose/alternate multipurpose mode Element manager, based on a graphical user interface for the control and monitoring of PLC and teleprotection systems Command interface binary and in accordance with IEC 61850 Remote access to PowerLink Via TCP/IP connection Via in-band service channel SNMP compatibility for integrating NMS Event memory with time stamp Simple feature upgrade through software 4

Substation Substation Phone (ISDN or analog) Remote terminal unit Computer (data transmission) Protection relay Router Modem connection PowerLink developed for the challenges of the future PowerLink has numerous outstanding features and functionality, many of which are patented. The real hallmark of the system, however, is its openness and flexibility, which offers you a host of technical options for the best operation of your communication networks. You can use PowerLink for the transmission of: Protection signals Telecontrol signals Voice Data TCP/IP communication For this purpose, PowerLink has analog and all current digital interfaces. Because these can be combined flexibly, you can protect investments you have already made, and continue to use the older analog terminals while you gradually switch over to the new communication technologies. At the same time, with PowerLink, you already have at your disposal all the possibilities of TCP/IP communication which is increasingly emerging as the standard in the power supply area as well. 5

One solution for highest performance Best transmission performance under all operating conditions Variable transmission power The transmission power can be configured via software in two ranges (20 50 W or 40 100 W), based on the requirements of the transmission path. This makes it easy to comply with national regulations and to enable optimized frequency planning. Optimal data throughput under changing environmental conditions PowerLink adapts the data rate to changes in ambient conditions, thus guaranteeing maximum data throughput. Thanks to PowerLink s integral prioritization function, which can be configured for each channel, routing of the most important channels is assured even in poor weather conditions. Integrated versatile multiplexer () The is a statistical multiplexer with priority control. Asynchronous data channels can be transmitted in guaranteed or best effort modes, to guarantee optimal utilization of available transmission capacity. The priority control ensures reliable transmission of the most important asynchronous and synchronous data channels and voice channels even under poor transmission conditions. Naturally, the is integrated into PowerLink s management system, and with its extended options for transmitting digital voice and data signals perfectly equipped for the power line communication requirements of the future. For highest bandwidth efficiency, PowerLink offers integrated voice compression with different compression rates between 5.3 and 8 kbps. To prevent any impairment of voice quality, the compressed voice bands are routed transparently through transit stations without requiring additional decompression and compression. 6

Bridge to IP This functionality is best suited for the migration from TDM to packet-switched networks. PowerLink offers electrical and optical Ethernet interfaces, including an integrated L2 switch, extending the IP network to remote substations with a bit rate up to 320 kbps. Integrated teleprotection system SWT 3000 Two independent SWT 3000 systems can be integrated into PowerLink. Each SWT 3000 system can be used to transmit up to four commands in different operation modes. For maximum availability, an alternate transmission path via a digital communication link can be connected.

One technology many applications PowerLink s high degree of flexibility becomes readily apparent when we take a closer look at each of its potential applications. No matter what tasks are as - signed to the system: PowerLink s high quality and protective function are first-class in every case. PowerLink for telecontrol transmission remote terminal unit polling is, together with protection signal transmission, still a core requirement and use case for PowerLink. This is why polling is available in many different ways. Typically, a number of s are spread over several substations and connected in a daisy chain to a centralized power system control center (SCADA). PowerLink can be applied in analog mode via FSK channels or in digital mode via the implemented data pump to transmit information. Even old s with a VF modem can be connected directly to PowerLink. Our integrated multiplexer and the StationLink function offer pointto-point and point-to-multipoint operation for remote terminal units. Telecontrol via the integrated multiplexer Digital modulation (dplc) Polling telecontrol data via the integrated multi - plexer with data rates up to 19.2 kbps up to 19.2 kbps Power system control center Substation A Telecontrol via point-tomultipoint connections The functions of a power system control center include the regular interrogation of event data from the telecontrol units. Point-to-multipoint polling can be implemented in a substation between the Power- Link systems by means of the StationLink function. Substation C Substation B StationLink Point-to-multipoint connection for asynchronous data ( polling) Local Substation D Power system control center 8

ifsk up to 2,400 bps ifsk Power system control center Telecontrol via the integrated FSK channel Analog modulation (aplc) Connection of a telecontrol unit to an integrated modem Telecontrol with modem via the rfsk channel FSK modem FSK modem Power system control center Digital modulation (dplc) Polling telecontrol data from TCUs with integrated FSK modem via the at up to 2,400 bps 9

PowerLink for data transmission The versatile multiplexer integrated in PowerLink provides the following functions: Asynchronous data transmission Up to eight data terminal devices can be connected to PowerLink via the RS232 interface. These asynchronous data channels can be transmitted in the guaranteed or best effort modes, and thus guarantee optimal utilization of the available transmission capacity. Synchronous data transmission PowerLink provides 2 X.21 or 1 G703.1 interfaces for the data link between plesiochronous (PDH) or synchronous (SDH) transmission networks. LAN connection PowerLink permits the establishment of a LAN connection between substations in the high-voltage network. Electrical and optical Ethernet interfaces as well as an integrated L2 switch allow IP-enabled data terminal equipment to be connected directly at low cost. Transparent analog data transfer When PowerLink is used in analog mode, a maximum of four conventional asynchronous data channels (up to 2,400 bps) can be transmitted transparently by means of FSK modulation. Max. 2 x X.21 or 1 x G703.1 For example, data terminal Flexible combination of interfaces until full transmission capacity is attained Max. 8 x RS232 connection PtP, PtMP Optional 4 x RS232 with FSK modulation in analog operation Ethernet TCP/IP For example, router 10

PowerLink for telephone networks PowerLink is designed to connect different types of telephone systems and individual telephones from analog to IP. In transit stations, the compressed voice band is routed transparently, with no additional decompression and compression, so that the end-to-end voice quality is not degraded. This StationLink functionality for voice channels is shown in the graphic below. 1 2 3 4 1 Analog interface Analog connection of individual telephones 2 Analog interface Analog connection of telephone systems a/b E & M PABX E1 PABX TCP/IP 3 Digital interface Digital connection of telephone systems 4 TCP/IP interface Connection of telephone or telephone systems via TCP/IP Power system control center Substation A Substation B Substation C PABX PABX PABX PABX StationLink functionality for voice channels 11

PowerLink for protection signal transmission The teleprotection system SWT 3000 can be operated as an integrated system (with a maximum of two systems) or adapted with PowerLink. Every SWT 3000 system can transmit up to four protection commands. The command interface type for distance protection devices can be either standard binary or compliant with IEC 61850. Even a combination of both command interface types is supported. For highest availability, an alternate transmission path via a digital communication link (for example, SDH) can be connected. Alternate multipurpose mode: In this mode, the entire transmission capacity is used for voice and data as long as it is not needed for protection purposes. The PowerLink pilot tone is used as the guard tone in this mode. If a protection command needs to be transmitted, voice transmission is interrupted for the duration of transmission of the protection command. Data transmission may also be interrupted if the relevant parameter is set. The SWT 3000 system offers you a unique and varied range of operating options: Single-purpose mode: In this operating mode, the PowerLink transmission channel is used exclusively for transmitting protection signals. Maximum transmission range, with the highest reliability in the case of pulse noise and the minimum signal propagation delay, are achieved in this mode. Multipurpose mode: In this mode, voice and data are transmitted parallel to protection signals. Protection signal transmission 1 External SWT 3000 4-wire link 2 External SWT 3000 Fiber-optic link 3 Internal SWT 3000 Integrated in PowerLink 4 Internal SWT 3000 Integrated SWT 3000 with path switching via digital networks (1+1) 1 2 3 4 SWT 3000 SWT 3000 SWT 3000 SWT 3000 SDH/PDH 12

Easy-to-operate the PowerLink management system All applications in PowerLink, like the versatile multiplexer and the integrated and external SWT 3000 devices, use one common HMI. PowerSys administration interface Intuitive and easy-to-operate, the Windows-based Power- Sys software runs on all standard PCs. In addition to local operation, PowerLink also offers two options for remote administration. This makes it possible to meet a wide range of different customer infrastructure requirements. Regardless of the chosen solution, the user has complete system access just as with a direct local connection. For easy maintenance, the integrated event recorder with real-time clock synchronization options provides the required information. Remote access via in-band channel RM Remote access via IP The administration of remote PowerLink systems can be easily performed from the local operator console via a customized service channel or the IP network. Administration can also be performed via the corporate LAN network, using the common TCP/IP network protocol. The system can be connected with its own network protection equipment and a firewall to ensure the security level necessary for the company. PowerLink systems can be integrated in higher-level management systems via the IP access, using the SNMP protocol (simple network management protocol). System and network status data can be transferred, for example, to an alarm, inventory, or performance management system. In case the PowerLink devices in stations B and C are enabled with Ethernet service, station C is also part of the NMS supervision. Station A Station B Station C Station A Station B Station C RM addr. 1 RM addr. 2 RM addr. 3 RM addr. 4 SSF RM RM Switch/hub Local PowerSys PLC transmission path RM link in the substation RM Remote maintenance interface SSF Front service interface RM addr. Remote administration address NMS LCT IP network NMS Network Management System LCT Local craft terminal Remote access via in-band channel Remote access via IP 13

Published by and copyright 2013 Siemens AG Infrastructure & Cities Sector Smart Grid Division Services Humboldtstr. 59 90459 Nuremberg, Germany For more information, please contact our Customer Support Center Phone: +49 180/524 84 37 Fax: +49 180/524 24 71 (Charges depending on provider) E-mail: support.ic@siemens.com Order No. IC1000-G240-A166-X-4A00 Printed in Germany Dispo No. 06200 c4bs No. 783 GB 130023 3316002981 WS 02131.0 Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.