Description UPS Management Software



Similar documents
UPS MANAGEMENT SOFTWARE

UPS MANAGEMENT SOFTWARE OPTIONS

UPS Management Software

Options and monitoring

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

SentryPlus. Shutdown Management Software for Windows. User s Manual

Sentry Bulldog Shutdown Management Software (For UNIX Series)

UPS-Management Software

UPS-Management Software

UPS-Management Software

UPS-Management Software

UPS SNMP Watch User manual

Communication and connectivity the ideal solution for integrated system management and data integrity

Network Management Card. User Manual

User and Installation Manual

NetCrunch 6. AdRem. Network Monitoring Server. Document. Monitor. Manage

Introducing Tripp Lite s PowerAlert Network Management Software

securityprobe 5E Standard

Software and accessories

Secure Power Always. Agility Series UPS ( VA) Chloride Connectivity Solutions. Product data sheet

Bulletin 1609 UPS Management Software

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

PN5212/PN5320/PN7212/PN7320

0MNU106NPB-GB. This release supersedes all previous releases. Specifications are subject to change without any prior notice. UPSMON User Manual

Dell Network Management Card. User's Guide. w w w. d e l l. c o m s u p p o r t. d e l l. c o m

Connectivity. PowerShield 3. Communications Software

securityprobe5es -X20

UNMS II UPS Network Management System

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

EPSON Stylus C84N. Supplement. Includes information about networking utilities and installation on Windows 98 and Me

SNMP Web Management. User s Manual For SNMP Web Card/Box

RES ONE Automation 2015 Task Overview

Belkin Bulldog Plus. Shutdown Management Software for Windows. User s Manual

Firewall VPN Router. Quick Installation Guide M73-APO09-380

Installation and Configuration User's Guide

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

User s Manual Network Management Card

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide

User s Manual. Remote Management Card RMCARD202. Intelligent Remote Management Card allows a UPS system to be managed, monitored, and configured

IBM Tivoli Monitoring for Network Performance

Data Logger & Net Client Software (Windows, ipad, Android) Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment!

QuickSpecs. Overview. Compaq Remote Insight Lights-Out Edition

UPS Monitoring Software. User manual Borri Power Guardian

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

RCCMD Multiple Server Shutdown Software

Network User's Guide for HL-2070N

SITRANS RD500 Configuring the RD500 with PSTN or GSM modems and Windows-based servers and clients for communication Objective:

Option Network Management Software for UPS UNMS II

User Manual WatchPower

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

Environmental Monitoring Unit

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Course Description and Outline. IT Essential II: Network Operating Systems V2.0

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

PowerPanel Business Edition USER MANUAL

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Remote Supervisor Adapter II. User s Guide

INTELLECT TM Software Package

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

Belkin Bulldog Plus Shutdown Management Software for Windows

HP Netserver/Server Server Management Reference Guide

1 Getting Started. Before you can connect to a network

Version: UPS WEB/SNMP MANAGER. CS121 Series. Additional Components (CS121 Extensions) User Manual English

Semaphore T BOX Applications in Data Center Facilities

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

Multi-Homing Dual WAN Firewall Router

User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I Rev B

ABB solar inverters. User s manual ABB Remote monitoring portal

Server Management with Lenovo ThinkServer System Manager

Network Management Proxy 5 User manual

MONITORING. m 3 /s. m/s F Pa. g/m 3. Software. Data Input. M2M Transfer. Processing. XML/HTTP SNMP, GPRS/SMS. Measurement Sensors Dry contacts

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

Title Page Web/SNMP Management SmartSlot Card

NetAgent. UPS SNMP Agent. User s Manual

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

UPS Communicator. UPS Communicator English Manual Release

SNMP-NET UPS SNMP Card (Web-Based monitoring SNMP Card)

SANUPS POWER MANAGEMENT SOFTWARE SANUPS SOFTWARE

Securely manage data center and network equipment from anywhere in the world.

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The

Installation Guide for the Intel Server Control

How To Set Up Power Supply On Windows (Windows) With Powerup (Windows 8) On Windows 7.1) On A Pc Or Windows 8 (Windows 7) On An Ipad Or Ipad (Windows Xp

ViewPower User Manual

ActiveXperts Network Monitor. White Paper

EventSentry Overview. Part I About This Guide 1. Part II Overview 2. Part III Installation & Deployment 4. Part IV Monitoring Architecture 13

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

InsightPower Client. Shutdown Management Software for Windows 2000/XP/2003. User s Manual

WebPower UPS SNMP HTTP AGENT

User s Manual. Management Software for Inverter

Using Integrated Lights-Out in a VMware ESX environment

Opengear Technical Note

Niagara IT Manager s Guide

Network Management Card

Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7

Transcription:

UPSMAN UPSMON/UPSVIEW UPSMON CUSTOM Version: 2012-12-07 UPS MANAGEMENT SOFTWARE UPSMAN/UPSMON/UPSVIEW, and UNMS II Comprehensive UPS Administration and Alerting UNMS II Firewall UPSMAN Server + 2 Sender Windows Server UPS OS/2 Shutdown! Unix Shutdown! UPS CS121 UPSMAN Server + 2 Sender Event and scheduling configuration module and grafical monitoring interfaces Network shutdown messaging and command client module for heterogeneous networks Central Management of UPS, BACS, Environmental sensors & alarm contacts Communication via LAN/VPN, GSM, Modem, Email Customizable, user configurable graphical interface Description UPS Management Software The Software is a collection of client/server modules for networks and local workstations for monitoring the status of system resources and managing operations in response to changing conditions. While just one single component module, UPSMAN, would suffice for managing a simple UPS system at the most basic level, the collection of different modules can be scaled and combined to form very elaborate and sophisticated intelligent facility management systems. These systems can range from one server serially connected to single UPS in one building to a wide area network consisting of thousands of clients of various operating systems secured by diesel aggregates, battery conglomerates and other alternative UPS systems spread out over international borders. The server module of the Software is UPSMAN, which communicates via RS-232, USB or SNMP with the UPS or the UPS SNMP adapter. When UPSMAN begins, it collects the messages sent from the UPS and analyses received messages to notify the administrator/operator. Grafically all the UPSMAN actions can be monitored using the client modules Windows UPSMON, UNMS, UPSVIEW or any web-browser. The UPSMAN is able to manage UPS systems with potential-free contacts or serial interfaces (RS-232) from more than 100 UPS manufacturers. 80% of the UPS products in the world are supported through UPSMAN or the CS121 today. UPSMAN Configuration - Main Page UPSMAN Event Configuration - Comfortable Overview of all Events and their Corresponding Actions. UPSMAN insert Event Function every Event can be individually programmed with Responses, such as Text Log Entry, Email/SMS Notification etc. Copyright of the European Union is effective (Copyright EU) (c) 2012 GENERE Systems GmbH, Hamburg, Germany, All rights reserved

Description UPSMAN If UPSMAN detects voltage variations, power loss or any other UPS condition, it can respond with a wide variety of ACTIONs to each different EVENT, which for example may shutdown the server or send warnings and emails to connected users. The user can alter the configuration in respects to network messaging, sending of email or SMS, (Remote Console Command) shutdown, etc. More than 12 languages are supported. UPSMAN for Windows P/VISTA Business/2000//2003 Server/2008 Server/Windows 7, Novell NetWare and UNI have an SNMP proxy agent, which translates all UPS data into SNMP format. This allows for NMS software like HP Openview, IBM Netview and others to utilise its own processing tools. Every UPSMAN comes with its own web-server, that allows the monitoring or configuration from remote using any standard web-browser. UPSMAN runs also on less widely spread platforms like DEC VMS/Compaq and APPLE MAC and of course, inside the CS121 Web Adapter. CS122 UPS Status Text Log File viewed via Web-Browser UPSMON/UPSVIEW monitoring the UPS via Web-Browser remotely Description UPSMON/UPSVIEW UPSVIEW is a grafical Windows client for operating and monitoring the active UPSMAN software connected to an UPS. UPS-Routine schedules can be programmed (e. g. define dates for automatic UPStests, shutdown the system at defined dates, etc.) to check the status of the UPS, and execute different programs or create power quality statistics. With UPSVIEW you can evaluate the event protocol (log file) that is permanently updated by UPSMAN. The data communication to the UPSVIEW is achieved via TCP/IP, IP, NetBEUI or SNMP. The integrated Java tool JAVAMON for UPSMON/UPSVIEW and web server/html for the CS121 series are alternative grafical administration interfaces that can be conveniently accessed via the network/internet. UPSMAN on CS121 Web-Browser Configuration/Monitoring Windows UPSMON/UPSVIEW Monitoring a simple Network UPS Copyright of the European Union is effective (Copyright EU) (c) 2012 GENERE Systems GmbH, Hamburg, Germany, All rights reserved

Description UNMS II The UNMS is a customizable network management software for the centralized or remote monitoring of UPS, Inverters, Rectifiers, Battery management system BACS and other power management devices. Additionally the system monitors Environmental sensors and alarm contacts like smoke sensors, door contacts, or any other GENERE sensor The UNMS is fully web-based and may be managed from any computer with a web browser in the network. A very special feature is the customizable interface of the UNMS. This allows the user to adjust the graphical look & feel of the software to his installations and makes the use of the product much easier than standardized software interfaces without customizable screens. Separate users setups allow access to the different management levels only for authorized users. The connection between the monitored devices is established through 4 ways (see picture below): A. UNMS Teleservice - Network LAN - this is a connection via TCP/IP through a LAN and/or VPN- Tunnel, a secured internet connection. B. UNMS Teleservice GSM Wireless- this is a wireless GSM/EDGE Network connection through a VPN Tunnel of the GENERE DATASERVER portal. C. UNMS Teleservice Email Trap this is a Push Email connection called EmailTrap, transmitting all data through the SMTP Protocol. D. UNMS Teleassistance Modem This Modem Peer-to-Peer solution is not longer supported after 2012, replaced by the solutions A - C. All 3 modes can work simultaneously so that all devices can be managed by a single UNMS, its a combination of local and remote monitoring system. UNMS II Datenblatt The City The Country The Systems- Configurate Copyright of the European Union is effective (Copyright EU) (c) 2012 GENERE Systems GmbH, Hamburg, Germany, All rights reserved

Description Every UPSMAN includes an Server ("Remote Console Command"). The counterpart is an additional client module, which executes a command on a remote system, similar to the Remote Shell- Program (RSH) known in the UNI world. is used to provide a simultaneous and secure shutdown of several servers and/or workstations on almost any platform. is also capable of relaying messages and commands to remote LAN/WAN clients. Using the specially developed network protocol, is the most successful UPS shutdown solution for networks and available for more than 35 operating systems. With its latest extension is now more flexible and offers more functions, such as: Message transfer via TCP/IP between different operating systems: An alarm message from a Windows network maybe also distributed in UNI and Mac network. This is particular applicable when using SNMP adapters, which normally only respond by sending SNMP traps to an operator. Via 2 a CS121 can now react via Windows network message and UNI -message and notify users. Automated remote maintenance from network computers without user account or login: 2 can execute any program on a remote computer No login required. Grafical configuration interface for all functions, also for UNI and Mac OS (from 10.x) Alive-Check clients may periodically check if the UPSMAN sender is available. group from up to 4 UPS as a parallel redundant system. Client Redundancy Configuration Page Diagram Modul Comfortable Shutdown Configurator Copyright of the European Union is effective (Copyright EU) (c) 2012 GENERE Systems GmbH, Hamburg, Germany, All rights reserved

Features Available for Windows 9x, NT (INTEL, ALPHA, MIPS), 2K, P, 2003/2008 Server, Netware, Mac OS 9.x and 10.x, 15 UNI versions and Open VMS and IBM OS/2. Logging of all UPS information and measurement values in CSV, comma separated values, format for MS-Excel, Lotus, GChart (http://www.generex.de/e/download/cs12x/gchart.html) Monitoring of UPS systems with potential-free contacts or serial interface. Scheduler for time controlled execution of functions, such as battery test, reboot, shutdown etc. Automatic shutdown, Multiserver Shutdown: Unlimited shutdown manager for clients for more than 40 different operating systems. This makes it possible for an UPSMAN Server to notify and shutdown any type of computer in a given network, which can then be used to centralize the administration of large networks while greatly reducing both the amount of organisational work and the amount of consumed network time for communications. Different methods are available for conducting shutdowns and system start ups: 1. Cold-boot (computers are directly cut-off from or connected to the power supply. This option may require a SiteSwitch.) 2. Warm-boot (using operating systems are prompted to shutdown or restart.) 3. Wake on LAN (using data packages other computers in a local network are prompted to startup.) Program execution, messaging, logging etc. of local and remote computers into the network. (Master/Slave via module). Grafic display of input voltage and frequency with min., -max. and average values. Password protection of all UPS remote functions Multiple-start possible to control several UPS from one computer Scheduling of up to four electrical sockets (special UPS types or optional hardware type SS4 required http://www.generex.de/e/products/facillities/site_switc h/siteswitch_p.html ) Configuration and look & feel is identical on all platforms (UNI, Windows, NetWare, VMS, MAC OS) User messages in 12 languages UPSMAN can work with extension modules such as the SensorManager (temperature/humidity and other sensors), RASManager (modem solution), SiteSwitch (power distribution and switching unit), UPS SNMP Watch (software for parallel redundant UPS), HP Openview snap-in, etc. Supports nearly all UPS devices of allimportant UPS manufacturers using RS-232 protocol and contact closure interfaces. Display of the autonomy time and user notification of warnings for low battery, battery error, over temperature, and hardware errors. Log files have a date/time stamp and the UPSMON/UPSVIEW tool bar has a counter for power failures, battery low, system shutdowns and test failures. SMTP compatible system with transmission of information via email, email to SMS or other external services. Integrated SNMP-Agent (RFC 1628 or private MIB) for NetWare, Windows NT/2000, Linux and SUN. Event dependent sending of network messages, logging, email, program execution, etc. Copyright of the European Union is effective (Copyright EU) (c) 2012 GENERE Systems GmbH, Hamburg, Germany, All rights reserved

software - CS121 Web software for Windows NT/2000/2003/P/VISTA CS121 SNMP WEBMANAGER software for Unix/Mac OS systems Network Protocol TCP/IP, NetBEUI, SNMP TCP/IP, FTP TELNET, PPP, SNMP, ARP andothers TCP/IP, FTP TELNET, PPP, SNMP, ARP andothers Remote UPS monitoring - Shutdown support 2 - Extended remote shutdown function 3 - group/redundancy for up to 4 UPS HP Openview LAN support Network Messaging UNMS - Multi-system remote control Modbus Facility Management capability - - Web browser management Scheduler shutdown History / Event log file Multi-language text log files and network messages Unattended installation available (for automatic script based installations) - Password protected remote functions e.g. Emergency off, reboot, tests, etc. UPSMAN/UPSMON/UPSVIEW CS121 Web/Adapter UPS - functions software for Windows NT/2000/2003/P/VISTA CS121 SNMP WEBMANAGER software for Unix/Mac OS systems UPS-Standard functions/warning: e.g. Battery low power failure overload UPS connection restored System shutdown UPS-Standard functions/warning: e.g. Inverter overload Fuse blown Rectifier mains fault Inverter feeding Battery switch open UPS - send UPS shutdown signal UPS - SNMP redundancy capability (USW software) Graphic display UPSMON / HTML / JAVA Environmental monitoring - Facilitymanagement e.g. GENERE SITEMANAGER, SITEMONITOR, SENSOR- MANAGER, SITESWITCH Qualified hotline Korean and Japanese language Copyright of the European Union is effective (Copyright EU) (c) 2012 GENERE Systems GmbH, Hamburg, Germany, All rights reserved