FAST AND EFFICIENT PURIFICATION OF SYNTHETIC PEPTIDES BY SOLID-PHASE EXTRACTION



Similar documents
Experimental procedures. Solid phase peptide synthesis (SPPS)

1) Technical informations. - a) How does it work? - b) Purification - c) Quality Control. 2) Standard synthesis

Novel Method for Solid Phase Peptide Synthesis Using Microwave Energy

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Peptide Synthesis Zheng Miao* and Zhen Cheng

Small μmol Scale Synthesis of a Labeled Antimicrobial Peptide using Biotage

Aspects of industrial purification of peptides using large-scale chromatography. Lars Andersson and Jonas Persson

How To Use An Acquity Qda Detector

Standard practices for Fmoc-based solid-phase. peptide synthesis in the Nowick laboratory. (Version 1.6.1)

Structure-Based Design of Covalent Siah Inhibitors

Peptide synthesis, radiolabelling and radiochemical analysis

Solid-phase Synthesis of Homodimeric Peptides: Preparation of Covalently-linked Dimers of Amyloid-beta Peptide

USP's Therapeutic Peptides Expert Panel discusses manufacturing processes and impurity control for synthetic peptide APIs.

Short Peptide Synthesis

Oasis HLB Cartridges and 96-Well Plates

How To Make A Peptide

Guidance for Industry

Purification of reaction mixtures using flash chromatography.

Peptide Library Synthesis

Solid Phase Peptide Synthesis Methodology with Integrin α5 and Ligand Ac-RGDNP-NH2

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary

Acid CleavageLDeprotection in Fmoc/tBu Solid-Phase Peptide Synthesis

Supplemental data. A simple and effective cleavable linker for chemical proteomics applications

SYNTHESIS OF BIOLOGICALLY ACTIVE PEPTIDES ON PS-BDODMA RESIN USING Boc-CHEMISTRY

Synthesis of Leucine Zippers and Leucine Zipper Dendrimers

Rapid Microwave-Assisted Solid Phase Peptide Synthesis

Supporting Information

PROTEIN SEQUENCING. First Sequence

ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup

Basics of SPE Technology & Mechanisms. Pieter Grobler, Sigma-Aldrich RSA

Automated Fast-Bead Synthesis of Small Peptides

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Dr. Rita P.-Y. Chen Institute of Biological Chemistry Academia Sinica

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary

Application Note. Increasing the activity of monoclonal antibody isoforms by MCSGP. Summary

Overview'of'Solid-Phase'Peptide'Synthesis'(SPPS)'and'Secondary'Structure'Determination'by'FTIR'

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

Spatial Screening of Cyclic Neoglycopeptides: Identification of Multivalent Wheat Germ Agglutinin Ligands**

K. M. Bhaskara Reddy, 1 Y. Bharathi Kumari, 2 Dokka Mallikharjunasarma, 1 Kamana Bulliraju, 1 Vanjivaka Sreelatha, 1 and Kuppanna Ananda 1

The latest SPPS application data

Ion Exchange Determination of Na+ by Displacement and Zn 2+ Using Preconcentration. Reading: Harris pp , 699

Materials and Methods. Protocol for Fmoc- based solid- phase peptide synthesis

Combinatorial Chemistry and solid phase synthesis seminar and laboratory course

An In-Gel Digestion Protocol

The basic division explosives for forensic purposes is shown in Fig. 1

Supplemental Material: peptide synthesis

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Note. Optimization of protocols for solid-phase synthesis on a flexible crosslinked support: Synthesis of [Leu 5 ]enkephalin

Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

1. COUPLING REAGENTS : Structure and acronyms

The Theory of HPLC. Gradient HPLC

Melting points (m.p.) were determined using a Reichert hot-stage melting point

Quality. Now Certified to ISO 9001:2008

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

EMMI Intensive Programme "Design, Synthesis and Validation of Imaging Probes Torino, September 2011

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

The Peptides Vol. 2: Analysis, Synthesis, Biology: Special Methods in Peptide Synthesis

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

ORIGINAL SCIENTIFIC PAPER. Gabriella POHN. Éva VARGA-VISI SUMMARY KEY WORDS

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Peptide purification strategies

Simple, economical and flexible apparatus for solid phase peptide synthesis

How To Test For Contamination In Large Volume Water

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Efficient Synthesis of Peptides with 4-Methylpiperidine as Fmoc Removal Reagent by Solid Phase Synthesis

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

Working with Hazardous Chemicals

EXPERIMENT 5: DIPEPTIDE RESEARCH PROJECT

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

HiPer Ion Exchange Chromatography Teaching Kit

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Naturally occuring depsipeptides exhibit interesting

PrepTip. Reverse Phase PrepTip User Guide

Marmara Üniversitesi Fen-Edebiyat Fakültesi Kimya Bölümü / Biyokimya Anabilim Dalı PURIFICATION AND CHARACTERIZATION OF PROTEINS

PhD Theses STUDY OF THE SOLVENT GRADIENT SIMULATED MOVING BED PREPARATIVE LIQUID CHROMATOGRAPHIC PROCESS. Written by Melinda Nagy

Protection of the Amide Side-Chain of Asparagine with the 1-Tetralinyl Group in the Solid-Phase Peptide Synthesis of Lysine-Vasopressin

Dipeptide Synthesis. polarized light (Figure 2).

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Transcription:

ACTA CHROMATOGRAPHICA, NO. 14, 2004 FAST AND EFFICIENT PURIFICATION OF SYNTHETIC PEPTIDES BY SOLID-PHASE EXTRACTION W. Kamysz 1,*, M. Okrój 2, E. Łempicka 3, T. Ossowski 3, and J. Łukasiak 1 1 Faculty of Pharmacy, Medical University of Gdańsk, 80-416 Gdańsk, Poland 2 Intercollegiate Faculty of Biotechnology, Medical University of Gdańsk, 80-211 Gdańsk, Poland 3 Faculty of Chemistry, University of Gdańsk, 80-956 Gdańsk, Poland SUMMARY Post-synthesis purification of peptides is often the most difficult part of the synthetic procedure. In this study we describe the purification of two synthetic antimicrobial peptides (calcitermin and temporin A) by solid-phase extraction (SPE). Our results indicate that SPE is a rapid, inexpensive, and relatively efficient method for post-synthetic purification of synthetic peptides. INTRODUCTION Purification of peptides is often the most difficult part of the process used to obtain the compounds [1]. Several methods are used for isolation and subsequent purification of the post-synthesis mixture. Depending on the properties of the peptide and the types of impurity, commonly used techniques are ion-exchange chromatography and gel filtration [2,3]. The standard method for isolation is high-performance liquid chromatography [4,5], which enables separation of substances with negligible differences between their chemical structures. Unfortunately, the need for specialised equipment and columns and high buffer consumption makes this method relatively expensive. Solid-phase extraction (SPE) is a method originally developed for concentration of synthetic, biological, and environmental samples before analysis by conventional methods [6]. SPE can also have other applications, for example removing impurities from samples and isolation of analytes from biomatrices [7]. This method is essentially a short chromatographic separation with a variety of the applications. Four general extraction me- - 180 -

chanisms are used in SPE; these involve non-polar, polar, ion-exchange, and covalent interactions [8]. SPE has been reported to have advantages over other methods of extraction because of its speed, reproducibility, and efficiency and because emulsions are not formed [9]. Good results can be obtained when SPE is used as a purification method for synthetic peptides. The use of SPE for determination and quantitative measurement of two nanopeptides in fish plasma was described by Kulczykowska [10] and we have reported the use of SPE for purification of the 33-amino acid peptide statherin SV2 [11]. In this paper we describe the synthesis and subsequent SPE-based purification of two antimicrobial peptides, calcitermin (VAIALKAAHYHTHKE) and temporin A (FLPLIGRVLSGIL-NH 2 ). We show, that either large (200 mg) or small (20 mg) quantities of peptides can be purified by SPE and that this fast, one-step procedure furnishes products of >95 97% purity. There is, moreover, no need for sophisticated equipment and consumption of mobile phase is minimal. We postulate that use of SPE could be especially beneficial in the isolation of peptides from post-reaction mixtures or concentration of substances (e.g. after disulfide bond formation). EXPERIMENTAL Starting Materials N α -9-fluorenylmethyloxycarbonyl amino acids, trifluoroacetic acid (TFA), 1,3-diisopropylcarbodiimide (DIC), diisopropylethylamine (DIEA), 4-dimethylaminopyridine (DMAP), piperidine, N-hydroxybenzotriazole (HOBt), Triton, triisopropylsilane (TIS), and O-(benzotriazol-1-yl)-N,N,N,N - tetramethyluronium tetrafluoroborate (TBTU) were obtained from Fluka (Switzerland), and dimethylformamide (DMF), N-methyl-2-pyrrolidone (NMP), dichloromethane (DCM), and acetonitrile from Lancaster (Germany). All solvents and reagents used for solid-phase synthesis were of analytical grade. Wang resin for calcitermin synthesis (1% DVB, 1.0 mmol g 1 ) was obtained from Fluka. Polystyrene AM RAM resin for temporin A synthesis (1% DVB, 0.7 mmol g 1 ) was from Rapp Polymere (Germany). Kromasil C 8 (5-µm particle size, 100-Å pore size) was purchased from Eka Chemicals AB (Bohus, Sweden). - 181 -

Synthesis of the Peptides The peptides were synthesized manually on the 0.1 millimole scale by a solid-phase method using the Fmoc/Bu t procedure [12]. The sidechain-protecting groups of the amino acids were trityl for His; tert-butyl ether for Tyr, Ser, and Thr; tert-butyl ester for Glu; Pbf for Arg; and Boc for Lys. Attachment of the first residue to the Wang resin was achieved by DMAP-catalysed esterification [13]. Both peptides were synthesized using the Fmoc method, according to a two-step procedure: 1. 5- and 15-min deprotection steps using 20% piperidine in a 1:1 (v/v) mixture of DMF and NMP (in the presence of 1% Triton); and 2. coupling reactions performed with the protected amino acid diluted in a 1:1 (v/v) mixture of DMF and NMP in the presence of 1% Triton, using DIC as the coupling reagent in the presence of HOBt (Fmoc- AA:DIC:HOBt 1:1:1) for 1 h. The completeness of each coupling reaction was monitored by means of the chloranil test [14]. If the test was positive, the coupling reaction was repeated using TBTU and HOBt in the presence of DIEA, with mixing for 2 h. The protected peptidyl resins were treated with a mixture of 95% trifluoroacetic acid (TFA), 2.5% water, and 2.5% TIS for 1 h. After cleavage the solid support was removed by filtration and the filtrate was concentrated under reduced pressure. The cleaved peptide was precipitated with diethyl ether and lyophilized. Purification of Peptides Peptides were purified by solid-phase extraction (SPE). The SPE columns were prepared by transferring 2.5 g sorbent to a 20-mL plastic polypropylene syringe or 0.5 g to a 5-mL syringe; both syringes were equipped with porous disks at the bottom and top. The adsorbent was Kromasil C 8, 5-µm particle diameter, 100-Å pore size. The sample was forced through the column by use of a vacuum flask and rubber stopper, with the vacuum pulling the solution through the SPE column. Finally, the solution was collected in a test tube located inside the flask. Purification of Calcitermin Before use the column was conditioned by washing with 2 10 ml acetonitrile, 2 10 ml acetonitrile water (1:1), and 2 10 ml water - 182 -

0.1% trifluoroacetic acid. A 10-mL sample of a stock solution (1 2% acetonitrile) of the crude peptide (213 mg) was transferred to a prewashed SPE cartridge. After washing with water (10 20 ml) the peptide was eluted from the cartridge with 5 8 ml of solutions of 5, 6, 7, or 8% acetonitrile in water in the presence of 0.1% TFA (Fig. 1). Fig. 1 Reversed-phase (RP) HPLC chromatograms (gradient 10 70% acetonitrile in 0.1% TFA) of crude calcitermin (a) and samples eluted from the cartridge (2.5 g sorbent) with 5% (b), 6% (c), 7% (d), and 8% (e) acetonitrile containing 0.1% TFA in water Purification of Temporin A Before use the column was conditioned by washing with 2 3 ml acetonitrile, 2 3 ml acetonitrile water (1:1), and 2 3 ml water 0.2% trifluoroacetic acid. A 2-mL sample of a stock solution (10% acetonitrile) of the crude peptide (20.4 mg) was transferred to a prewashed SPE cartridge. After washing with aqueous acetonitrile (10 20%) the peptide was eluted from the cartridge with 2 3 ml of solutions of 25, 26, 27, or 28% acetonitrile in water in the presence of 0.2% TFA (Fig. 2). Finally, the columns were washed with acetonitrile. The cartridges were not allowed to dry during the purification and the flow of eluent was such that 1 ml liquid passed through the cartridge in approximately 15 20 s. Collected fractions were evaporated and lyophilized. - 183 -

Fig. 2 Reversed-phase (RP) HPLC chromatograms (gradient 35 80% acetonitrile in 0.1% TFA) of crude temporin A (a) and samples eluted from the cartridge (0.5 g sorbent) with 25% (b), 26% (c), 27% (d), and 28% (e) acetonitrile containing 0.2% TFA in water Analytical Procedure The purity of the fractions was tested by reversed-phase highperformance liquid chromatography (RP-HPLC) using a Beckman Gold System chromatograph and a 4.6 mm 150 mm, 5-µm particle diameter, 100-Å pore size, Kromasil C 8 column. The mobile phases were gradients prepared from 0.1% TFA in acetonitrile (solution A) and 0.1% aqueous TFA (solution B). For calcitermin the gradient was 10 70% A in 15 min; for temporin the gradient was 35 80% A in 15 min. The flow rate was 1.2 ml min 1. The presence of peptides was confirmed by the absorption peak at 226 nm. The peptides were characterized by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry (MALDI TOF-MS) and had the expected molecular weights. RESULTS AND DISCUSSION The aim of our experiments was to obtain highly purified peptides relatively quickly at minimal cost. Calcitermin and temporin A were purified with a cartridge prepared in this laboratory filled with an adsorbent - 184 -

commonly used in HPLC. To purify 213 mg crude (57%) calcitermin we used a cartridge filled with 2.5 g adsorbent. The procedure furnished 57 mg highly pure (98%) peptide. The quantities and purity of peptide in other fractions are depicted in Fig. 1. To purify 20.3 mg crude (49%) temporin A, 0.5 g adsorbent was used. The procedure resulted in 5.9 mg pure peptide (Fig. 2). Although particular fractions were analysed by HPLC, it can be difficult to determine the appropriate eluent concentration because peptides are eluted at an acetonitrile concentration approximately 10 15% lower than in HPLC. The best experimental results were obtained when appropriate concentrations were established using a small SPE cartridge and a small quantity of peptide. On the basis of extrapolation we can predict the method which is also suitable for obtaining larger samples. The method is rapid and effective. The true advantage was that the actual time spent on the purification of these peptides was approximately 5 min. Effective separation is possible when adsorbent with an appropriately small particle diameter (5 µm) is used. Commercially available cartridges (adsorbent particle diameter >10 µm) were not good enough for effective purification (data not shown). They are, however, suitable for desalting of peptides or preliminary purification [15]. Results better than those presented here could probably be obtained by use of finer adsorbent and thinner but longer cartridges. The only factor limiting separation is hindrance of flow in the cartridge, because relatively low pressure is applied (in our experiments negative pressure was generated by means of a water pump). SPE is an easy and inexpensive means of purification or separation of peptides [16]. It enables rapid and efficient purification of peptides with minimal consumption of organic solvents and eliminates the need for sophisticated equipment. Good results depend on use of adsorbent with an appropriate low particle diameter (<10 µm). The procedure can furnish pure peptide after one purification cycle only. ACKNOWLEDGEMENTS This work was supported by the Polish State Commitee for Scientific Research (KBN 3 P05F 04124). - 185 -

REFERENCES [1] G. Barany, N. Kneib-Cordonier, and D.G. Mullen, Int. J. Pept. Protein. Res., 30, 705 (1987) [2] S. Kiyama, N. Fujii, H. Yajima, M. Moriga, and A. Takagi, Int. J. Pept. Protein. Res., 23, 174 (1984) [3] F. Filira, L. Biondi, F. Cavaggion, B. Scolaro, and R. Rocchi, Int. J. Pept. Protein. Res., 36, 86 (1990) [4] H. Chen and C.J. Horvath, J. Chromatogr. A, 705, 3 (1995) [5] C. Shaw, Methods Mol. Biol., 32, 275 (1994) [6] H.N. Weller, Mol. Divers., 4, 47 (1998/99) [7] R.W. Fedeniuk and P.J. Shand, J. Chromatogr. A, 812, 3 (1998) [8] Varian Sample Preparation Products Catalogue, Varian Harbour City, CA, USA, 1995 [9] R.A. de Zeeuw, J. Chromatogr. B, 689, 71 (1997) [10] E. Kulczykowska, J. Chromatogr. B, 673, 289 (1995) [11] W. Kamysz, B. Kochańska, A. Kędzia, J. Ochocińska, Z. Maćkiewicz, and G. Kupryszewski, Polish J. Chem., 76, 801 (2002) [12] E. Atherton and R.C. Sheppard in S. Udenfriend and J. Meienhofer (eds) The Peptides: Analysis, Synthesis, Biology, Academic Press, New York, 1987 [13] S.S. Wang, J.P. Tam, B.S. Wang, and R.B. Merrifield, Int. J. Pept. Protein. Res., 18, 459 (1981) [14] W.S. Hancock and J.E. Battersby, Anal. Biochem., 71, 260, (1976) [15] A.G. Bonner, L.M. Udell, W.A. Creasey, S.R. Duly, and R.A. Laursen, J. Pept. Res., 57, 48, (2001) [16] R. Pipkorn, C. Boenke, M. Gehrke, and R. Hoffmann, J. Pept. Res., 59, 105 (2002) - 186 -