T200, PTP/IEEE 1588 Grandmaster Clock and



Similar documents
Indoor / Outdoor Antenna

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

Precision Time Protocol (PTP/IEEE-1588)

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Waveguide Access Point WGA631. Product Guide

How To Run A Gps Time Server In A Gpx Device In A Powerbox (Gps) On A Gpm (Gpl) Or Ipa (Gpt) Device

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Communicate and view data from meters with one simple device

PPS usable by timing applications via serial port emulation

The Role of Precise Timing in High-Speed, Low-Latency Trading

Rack mounted telephone- and leased line modem for industrial applications

Loop-IP6702 TDMoEthernet

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

ORION TELECOM NETWORKS INC. T1

GPS NTP TIME SERVER Rack Version V2

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

Power Meter Series 700

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

3500/22M Transient Data Interface

Securing GNSS with PTP & SyncE Adam Wertheimer Microsemi Adam.Wertheimer@microsemi.com. Power Matters

GPS NTP TIME SERVER Rack Version V2.2x

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

Uninterruptible Power Supply

Telephone- and leased line modem for industrial applications TD-36

PowerGem Pro Uninterruptible Power Supply

SyncServer S250 S250 NETWORKING EXCELLENCE. Examples of Network Timing Configurations

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

GPS NTP Time Server for Intranet Networks DIN RAIL Version

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

SyncServer S300. High Performance, Enhanced Security GPS Network Time Server

Application. Key Features. Benefits. Contact us. Solution for Digital TV coverage. Multi DVB-T/-H/-T2 - & ISDB-T Gapfiller Nx1W

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

IFS SP-PoE Splitter User Manual

3500/62 Process Variable Monitor

STRATO LED Drivers 70W, Single output

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

TDMoEthernet. Description

SyncServer S350. Ultra Precise & Versatile GPS Network Time Server

SAH2217 Enhanced ATHEROS GPS Module with ultra high sensitivity and antenna open/short detection/protection

Loop-IP6700 TDMoEthernet

38 Series - Relay interface modules A

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

5GHz 300Mbps a/n Wireless Outdoor Access Point

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Quidway AR 18-1X Series Router Datasheet

TK800-Series Industrial GPRS / UMTS / LTE Router

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

G-TAP A Series // Data Sheet

Communication Unit 560CMU05 Data sheet

Cisco ASR 9001-S Router

Subject: Notice of Last Time Order and Manufacture Discontinuance of XL-GPS Time and Frequency Receiver Obsolescence Notice

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Product Specifications

USER MANUAL V5.0 ST100

EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions

38 Series - Relay interface modules A

7.5 Watt AC-DC Switch Power Supply

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

DLB Outdoor Wireless Device COPYRIGHT 2015 LIGOWAVE

HARTING econ 3000 Introduction and features

Overview of the Cisco 2500 Series Access Server

Data Loggers for Real Time Temperature Monitoring - WiFi

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Remote Monitoring and REC 501 Control Unit Product Guide

EMC Test for Compliance with EU EMC Directive 2004/108/EU

sat-nms SMU Signal Management Unit

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Mitel DECT Base Stations

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

Foxboro Evo Process Automation System

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

DLB 5-20 Outdoor Wireless Device DATASHEET. COPYRIGHT 2014 LigoWave

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

SNMP Web Management. User s Manual For SNMP Web Card/Box

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

1701/22 FieldMonitor Management Interface Module

Agilent 4338B Milliohm Meter

Loop-IP6700 TDMoEthernet

EMR. WAN Compact Router for Industrial Ethernet Networks. A secure access to Ethernet industrial networks making use of the public operator networks

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

Optimux-134, Optimux-125

Transcription:

T200, PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS receiver, OCXO or Rubidium oscillator 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 1

HEOL-T200 : PERFORMANCE and EASY INTEGRATION The HEOL-T200 PTP IEEE-1588 Grandmaster Clock / NTP Time server with GPS Clock has been designed to provide accurate timing information trough an Ethernet link (using Precision Time Protocol), for Network synchronization and measurement applications, without the need to be connected to external Network, hence preserving your Network insulation. Based on a high performance 14 channels GPS chipset with very high accuracy, and TRAIM algorithm, accuracy is guaranteed with only one GPS satellite tracked. It enables also fast start-up times in very hard environmental conditions, as only one satellite is enough at power-up to generate a precise Time-stamp (static applications). Precision Time Protocol (IEEE1588) has been implemented, for applications that need sub-microsecond synchronization (Grand Master Clock). The PTP V2 implementation of the HEOL-T200 is fully compliant to the IEEE 1588-2008 standard (two steps clock) and provides PTP management messages for monitoring and configuration (also available on HTTP server). The antenna (protected against short-circuit) does not need to be located up a mast or on the rooftop as is the norm, which considerably reduces the cost and complexity of deployment in terms of antenna cabling and lightning strike protection and reduces the cost of maintenance. If the satellites signals are completely lost, the hold-over mode enables the module to keep sending accurate Ethernet frames, with very low drift, thanks to the OCXO, or Rubidium oscillator (drift is better than 1µs/day). A web server with secure access allows you to configure the HEOL-T200, and monitor its status at a glance (GPS satellites strength signals, Ethernet connections, alarms, input/outputs ). Automatic E-mails can be sent by the HEOL-T200, periodically or when alarms appear. This function is fully configurable via the http server. 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 2

An isolated event input allows you to time-stamp events from external systems, with very high accuracy (±100 nanoseconds, refer to UTC atomic clock). The TimeStamp information is reported through RS232, SNMP trap, E-mail or Broadcast frame. Alarm relay is available, for driving your external systems in case of failure of the T200. Alarms are displayed through SNMP traps (Ethernet interface) or through RS232. SNMP can also be used to configure T200 parameters (instead of http web server). A highly accurate pps (TOP) signal is available on SUB-D9 or I/O connector (polarity, period, length, and delay compensation are configurable by user). It is also available with optional 1500V isolated static relay. IRIG-B003 and A003 output available in RS422 or TTL level (please contact HEOL DESIGN for this option). A RS232 or RS422 serial port can be accessed for remote control and monitoring (with NMEA protocol output). Historic data can be backed-up to an EEPROM (over 8000 status records). The Power On Ethernet enables installation of the HEOL-T200x without the need for additional cables to provide power (except for Rubidium option). The T200 is available in 2 different metal housings, either compact (except for Rubidium option), or 19 rack mounted form factor. This rack unit displays on a LCD module the status and timing information. Compact form factor (OCXO only) 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 3

GPS antenna AC/DC T200 OCXO or Rubidium Clock Power + PoE GPS time receiver Processor + FPGA Ethernet 100M RS232 RS422 External Events TOP/pps IRIG/10M Remote interface +NMEA Event inputs Sync outputs User systems PTP + NTP (synchro and events) HTTP (config) SNMP (alarms and events) SMTP (E-mail) Network NTP clients / servers Automated systems T200 synoptic and external links Note : Heol Design is not responsible for the operation or failure of operation of GPS satellites or the availability of GPS satellite signals. 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 4

SPECIFICATIONS GPS Receiver Type 14 channels Sensitivity -160dBm (tracking) Overdertermined clock 24 hours mode (self survey) Time Accuracy (pps) ±15 ns rms (1σ) Time to First Fix < 45 seconds (90%) (cold start) Warm up time < 15 minutes for full accuracy Active antenna voltage 5V or 3V, configurable Timing Generator Timing Ethernet protocol SNTP V4, NTP Broadcast/Unicast (200 requests per second maximum), 200 000 NTP Clients @ 1024s PTP Interface PTP IEEE1588-2008 : - UDP/IPv4 - Addressing mode : Multicast & Unicast - Delay Mechanism : End-to-End - Operation : Two Step Clock - Sync & Announce Intervals : 1, 2, 4, 8, 16, 32, 64 seconds - Priority 1&2 : 0 to 255 - Domain Number : 0 to 4 - Announce Receipt Timeout Multiplier : 2,3,4,5,6,7,8,9,10 PTP Management Messages for monitoring and configuration PTP Signaling Messages for unicast addressing mode OCXO Characteristics Rubidium Characteristics Frequency Stability : ± 500µs / day (constant temperature) Frequency Stability : ± 1µs / day (constant temperature) Power supply Input Voltage Power On Ethernet : compliant with IEEE 802.3af. Compact: 12/60VDC (-48V Telecom compliant) Rack: 85/250VAC, 110/250VDC Power consumption 7W (T200C), 9W (T200R), 25W (Rubidium) Interfaces Auxiliary DC Power Supply 2.54mm header, anti-extraction GPS Active antenna T200C : SMA T200R : SMA or N Ethernet link RJ45, 10/100Mbps + POWER Remote RS232 / RS422SUB-D9, 38400/8/No/1 pps output RS422, RS232, or fast static relay output. on SUB-D9 or I/O connector (3.81mm) Alarm Relay 2A/250V. 2500V isolation Event input 25V max peak voltage (add resistor if higher), 2500V isolation, ±100ns accuracy 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 5

Environmental Operating Temperature From 0/50 C to -40/+85 C, depending Upon the option Storage Temperature -40 / +85 C Humidity 90% non-condensing Dimensions (T200C) 201 x 95 x 26 (mm) Weight (T200C) 340 grams Dimensions (T200R) 1U -482.6mm (19 ) -depth with SMA 130 mm connector 150 mm -depth with N connector Weight (T200R) 1,85 Kg According to directive, the HEOL-T200 module has passed the following tests : EN55022/55011 class B : conducted and radiated emissions. EN61000-4-2: Immunity to electrostatic discharges. EN61000-4-3: Immunity tests on electromagnetic fields radiated at radio-electrical frequencies, with 10V/m electromagnetic field. EN61000-4-4: Immunity to rapid transients. EN61000-4-5: Immunity to surge. EN61000-4-6: Immunity tests on conducted interference, induced by radio-electrical fields. EN61000-4-8: Immunity to Power frequency magnetic field (30 A/m) EN61000-4-11: Voltage dips, short interruptions and voltage variations immunity tests. Compliance with the International Safety Standard for Information Technology (IEC/EN 60950). The HEOL-T200x module is RoHS (lead free) compliant. 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 6

I/O Connector T200 19 1U Rack rear view (with N antenna connector) 3&4 pins : Alarm relay or PPS/TOP output on Static relay (option PPSREL) - + 1 + 2-3 4 5 6 1&2 pins : Event input #1 5&6 pins : PPS/TOP RS422 output or IRIG B003 output (option IRIG) or Event input #2 (option EVENT2) I/O connector details 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 7

ORDERING PART NUMBER T200R-100ns-AC-I/O-OCXOSR Housing R: 19 Rack C: Compact PTP 100ns accuracy 1µs 10µs Power DC : 14 to 60V DC/POE: DC+Power Ethernet AC : 110 to 250V (Rack only) I/O option I/O connector mounted (blank : not mounted) Oscillator option OCXOSR : standard (0 / +50 C) OCXOMR : medium (-20 / +65 C) OCXOHR : high (-40 / +70 C) RUB : high stability Rubidium (Rack in AC version) - 0 / +50 C If other options are needed, just add the part number of these options at the end of the T200 part number : -422 for RS422 serial port instead of RS232 -EVENT2 for secondary Event input -IRIG for IRIG-B003 output -PPSREL for PPS/TOP output on fast static relay -N or TNC connector option (N only for rack) 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 8