Increase the measurement speed with NOVA



Similar documents
Case study: how to use cutoff conditions in a FRA frequency scan?

NOVA. Getting started

The Autolab control command is located in the Measurement General group of commands.

Automatic data recovery

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Technical Note T1. Batch Mode to Sequence Experiments. 1. Introduction

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Shock test severity based on Shock Response Spectrum

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Response Time: The time required for the UUT to complete an I/O request.

TwinCAT NC Configuration

HOW TO SELECT VARISTORS

Replacing the USB DIO Decoder

MOBILE ALERT MONITORING SERVICE TUTORIAL

Names of Parts. English. Mic. Record Button. Status Indicator Micro SD Card Slot Speaker Micro USB Port Strap Hook

MP-1010 Capture Device USB

Clean and energy-efficient vehicles Advanced research and testing Battery systems

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

Energy savings in commercial refrigeration. Low pressure control

FREQUENCY RESPONSE ANALYZERS

Instruction Manual Service Program ULTRA-PROG-IR

Cell Phone Vibration Experiment

DATA SHEET. TDA1510AQ 24 W BTL or 2 x 12 W stereo car radio power amplifier INTEGRATED CIRCUITS

Software version 1.1 Document version 1.0

Impedance 50 (75 connectors via adapters)

PD Power Bandwidth- Worst Case Analysis July 2008

Rapier V1. Laser Gaming Mouse. User Guide English

1000+ AUDIOMETER OPERATING INSTRUCTIONS

Event counters in NOVA

Names of Parts. English 1. Mic. Record Button. Status Indicator Micro SD Card Slot Speaker Micro USB Port Strap Hook

Oscilloscope, Function Generator, and Voltage Division

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

How To Use A High Definition Oscilloscope

Fundamentals of Signature Analysis

EDIC-mini Tiny model A39

Quick Start Guide Vodafone Mobile Connect USB Stick. Designed for Vodafone

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

Chapter I Model801, Model802 Functions and Features

Intelligent Digital Multimeters

Desktop Headphone amplifier with Advanced DAC

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

Electrical Resonance

Herschel PACS Test Procedure STM PACS-KT-PR-011 Issue: 1 Revision: -

EDMS Operation Manual. 1. Install the USB Driver. 1.3 Click next

DAKTON µ BOX MANUAL µbox User Manual 1

Wahl C50 Calibrator FEATURES

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

SENSORED BRUSHLESS MOTOR & SPEED CONTROLLER COMBOS

ASERIES ATM Access Management System

Cable Analysis and Fault Detection using the Bode 100

TECHNICAL NOTE TNOI32

EVOline Multimedia Modules

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

TDA W Hi-Fi AUDIO POWER AMPLIFIER

Application Note #49 RF Amplifier Output Voltage, Current, Power, and Impedance Relationship

Completely reversed, strain controlled fatigue tests of a steel alloy with E= MPa resulted in the following data:

AN1826 APPLICATION NOTE TRANSIENT PROTECTION SOLUTIONS: Transil diode versus Varistor

RapidIO Network Management and Diagnostics

Real-time PCR: Understanding C t

HIGH FREQUENCY TRANSFORMER WITH TRANSFORMER SWITCHOVER

FFT Spectrum Analyzers

Multi-Profile CMOS Infrared Network Camera

EMF16 and Model 201 Graphics Software for Win 98/NT/ME/2K/XP/Vista/Win7/Win8 and Win10

User Guide FFFA

LEARN MORE MARQUE M155 DESIGNED IN SANTA CRUZ, CALIFORNIA

Quick Start Guide Vodafone Mobile Connect USB Stick. Designed for Vodafone

XPost: Excel Workbooks for the Post-estimation Interpretation of Regression Models for Categorical Dependent Variables

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

MATERIALS. Multisim screen shots sent to TA.

Tutorial

HDMI over IP Broadcasting System ITEM NO.: HE05BT, HE05BER HDMI Matrix over IP Broadcasting

SERIES-PARALLEL DC CIRCUITS

OVERVIEW HARDWARE. Mode buttons. USB Micro socket. Kensington Security Slot. 8x8 playable grid. Mode buttons

Tektronix RSA306 USB Spectrum Analyzer

EC-Lab Software User's Manual. Version 10.1x February 2011

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz

Detection of Exposure Damage in Composite Materials Using Fourier Transform Infrared Technology

Process Optimizer Hands-on Exercise

Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en

How DSL Works. by Curt Franklin

NEW. EVEN MORE data acquisition and test stand automation

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

Acer ADSL Surf USB Modem

Region 10 Videoconference Network (R10VN)

Specmaster: A Simple Spectrum Monitoring Tool

Network Considerations for IP Video

BlueGate. Your easy to use reference for getting the most out of your product USER GUIDE. Enjoy FREE REGISTRATION

FLASH USB Introduction ENGLISH

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Connecting UniOP to Telemecanique PLC s


Embedded Systems Design Course Applying the mbed microcontroller

VIBRATION DATA COLLECTION: A ROAD WORTH TRAVELING?

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

Flow Visualization Using MS-Excel

Transcription:

Increase the measurement speed with NOVA Case study: how to increase the measurement speed by optimizing the USB communication with the Autolab? 1 USB 1.1 vs USB 2.0 Although the Autolab uses a USB 1.1 controller to time the measurements, it is possible to accelerate data transfer in between the Autolab and the host computer. This can be achieved by connecting the Autolab to a USB 2.0 powered hub rather than to the computer directly. This hub can then be connected to a USB 2.0 port on the host computer. This setup will force Windows to assign control of the Autolab PGSTAT to the Enhanced USB controller rather than the Universal USB controller. This can dramatically increase the communication speed between the Autolab and the host computer. No software upgrade is required for this connection setup. Any powered USB 2.0 hub will do. 2 Benefits Using the setup described in this technical note increases the communication speed between the Autolab and the host computer. This means that the following processes will become significantly faster: Uploading the Autolab interface Data transfer from the Autolab to the host computer Data transfer from the host computer to the Autolab Uploading of NOVA procedure to the Autolab after validation Real time display of data points in the measurement view The increase in transfer rate between the Autolab and the computer also means that procedures involving a lot of data transfer (like FRA measurement, or measurements with a repeat loop) will become faster. For illustration purposes, a FRA frequency scan in potentiostatic mode, from 10 khz to 0.1 Hz, 10 mv amplitude (rms), 50 frequencies with logarithmic distribution would take about 9 minutes to complete under normal circumstances and would take about 4 and ½ minutes with the USB 2.0 control setup. 3 Benchmark comparison To illustrate the increase in measurement speed a total of three procedures were used as benchmarks. The procedures are tested on the Autolab dummy cell, using both communication protocols. 1 Page

NOVA Technical note 13 3.1 Cyclic voltammetry potentiostatic The Autolab cyclic voltammetry potentiostatic was used as provided on dummy cell (c). Figure 1 shows the recorded data points plotted versus time. The time corresponds to the absolute time since the beginning of the experiment and it includes the preconditioning time (5 seconds in the procedure) and the time required to upload the procedure to the Autolab after validation. Using the normal USB control (USB 1.1), the time coordinate of the first data point is 7.7 seconds. Using the USB control described in this technical note, the first data point is recorded after 5.7 seconds, resulting in a net gain of 2 seconds. Figure 1 The data points recorded with the Cyclic voltammetry potentiostatic procedure (red curve USB 2.0 control, green curve USB 1.1 control) 3.2 Chrono charge/discharge The Autolab chrono charge discharge procedure was used as provided on dummy cell (a). Figure 2 shows the recorded data points obtained using the normal Autolab connection (USB 1.1), plotted versus time. The time corresponds to the absolute time since the beginning of the experiment and it includes the preconditioning time (10 seconds in the procedure) and the time required to upload the procedure to the Autolab after validation. Additional delays are introduced by the repeat loop. The total duration of the experiment is 92.3 seconds. 2 Page

Figure 2 The data points recorded with the chrono charge discharge procedure, using the USB 1.1 control Figure 3 shows the recorded data points obtained using the improved Autolab connection described in this technical note (USB 2.0), plotted versus time. The time corresponds to the absolute time since the beginning of the experiment and it includes the preconditioning time (10 seconds in the procedure) and the time required to upload the procedure to the Autolab after validation. Additional delays are introduced by the repeat loop. In this case, the total duration of the experiment is 72.3 seconds, resulting in a net gain of 20 seconds. 3 Page

NOVA Technical note 13 Figure 3 - The data points recorded with the chrono charge discharge procedure, using the USB 2.0 control Closer inspection of the data points reveals that the time delay introduced by the repeat loop is drastically reduced with the USB 2.0 communication protocol (see Figure 4). When the normal communication protocol is used, the time delay introduced by the repeat loop is roughly 3 seconds (22 s 19 s). When the USB 2.0 communication protocol is used instead, the overhead time introduced by the repeat loop is reduced to ca. 1 second, resulting in a net gain of 2 seconds for each repetition 1. 1 The count is therefore: 9 repeat loops, 2 second gain plus 2 seconds gained during the procedure upload = 20 seconds. 4 Page

Figure 4 Time delay introduced by the repeat loop shown in detail for the first repetition (red curves USB 2.0 control, blue curves USB 1.1 control) 3.3 FRA impedance potentiostatic The estimated time required to complete this measurement on dummy cell (c) is about 9 minutes. In practical measurement, using the USB 1.1 communication protocol, the total measurement time was slightly higher, around 10 minutes. This difference stems from the measurement repetitions introduced by gain or current range switches. Repeating the same measurement using the USB 2.0 communication protocol reduced the duration of the frequency scan to less than 5 minutes. 4 Conclusion These tests have clearly shown the benefit of using an addition USB 2.0 powered hub between the Autolab and the host computer. The communication speed is increased which in turn results faster measurements. This can be quite useful, especially during time critical experiments. 5 Page