How To Read A Powerline From A Powerpoint Powerline To A Power Source



Similar documents
Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

TEST REPORT EN (1997) +A1 (2001)

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

Recording. Smart recording (depending on the camera models)

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Intel Core i processor. 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The standard system is shipped without HDD. 2. For the HDD compatibility list, please

VS-4112U-RP Pro+ Hardware Spec.

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

Quad Core Intel Xeon Processor E3. 12 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

EMC Test for Compliance with EU EMC Directive 2004/108/EU

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

4GB DDR3 RAM. 8 x 3.5 SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 8 x hot-swappable and lockable tray. 4 x Gigabit RJ-45 Ethernet port

HICC-0600T D1 Network box camera

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

Wireless Day / Night Cloud Camera TV-IP751WIC (v1.0r)

Test Report #: Date: April 8, 2005

GV-FE420. Visítenos: Cámara IP Fisheye Megapixel

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

EMC TEST REPORT For. Webcam. Model Number: CAM67U

VS-100. PoE. H.264 PoE Video Server. H.264 Compression H.264 DI/DO. Compression Rate Comparison MJPEG MPEG4 H.264.

INTRODUCTION. -1- GV-LX4C3 Series April 24, 2012

CoreNVR 16. Network Video Recorder. Recording live monitoring and playback without additional PC. Control

Specification. Specification. 16 Based License x1080, 1280x1024, 1280x720, 1024x768 Decoding Capacity. or (H.

4-CH Hybrid Digital Video Recorder

5100 SERIES 32-CHANNEL SWITCHBOX NVR

A Full Range of Recording Systems

Specifier Notes: This guide specification incorporates CSI MasterFormat TM 2004 Edition Numbers and Titles.

DIGIEVER DS-4264 Pro+ NVR

2MP H.264/ MPEG-4/ MJEPG

Electromagnetic Compatibility Test Report Test results of Floww equipment

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

CoreNVR 9. 9-Channel Network Video Recorder with HDMI. Recording live monitoring and playback without additional PC

Wireless PTZ Cloud Camera TV-IP851WC (v1.0r)

mydlink One-bay Standalone NVR

DIGIEVER DS-1164 Pro+ NVR

Connect up to a total of 8 cameras from GV IP cameras (excluding GV Fisheye cameras) and third party IP cameras (of 640x 480

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

DS-7200HWI-SH/A Series DVR. Technical Specification

PoE-2600HD. 355 Pan. 90 Tilt. PoE af PoE H Mega-Pixel PT IP Camera 16 :9 FPS H.264

PoE-2600HD. 355 Pan. 90 Tilt. PoE af PoE H Mega-Pixel PT IP Camera 16 :9 FPS H.264

Megapixel PoE Day / Night Internet Camera TV-IP572PI (v1.0r)

AirCam OD-325HD-2.5MM

1.3 Mega-Pixel Video Quality

GV-FD MP H.264 3x zoom Low Lux WDR IR Fixed IP Dome

H.264 Internet Video Server

GV-FD2410 2MP H.264 3x zoom WDR Pro IR Fixed IP Dome

Telephone- and leased line modem for industrial applications TD-36

IP 67. IR-Cut. Day/Night. Filter

GV-FD3410 3MP H.264 3x zoom WDR Pro IR Fixed IP Dome

2-Megapixel Sony Progressive CMOS Sensor with Super Wide Dynamic Range and High Frame Rate

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

Network Camera SNC-P1

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

IR-Cut. Day/Night. Filter

AirCam PoE-2600HD. 355 Pan. 90 Tilt. PoE af PoE H Mega-Pixel PT IP Camera 16 :9 FPS H.264

CCID1410-ST 1/4" VGA IP PTZ Colour Dome Camera

GV-SD220-S Outdoor Full HD IP Speed Dome

DS-7600NI-SE/P Series NVR. Technical Specification

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

WN-200HD. 2 Mega-Pixels. 2.0 Mega Pixel Wireless 150Mbps IPCamera. High Quality 2.0 MegaPixel Image. Full Feature 150Mbps Wireless N Camera

5 Mega-pixel Bullet IR PoE IP Camera with Extended Support

1.3 CW-720IR. 720P Day/Night Wireless IPCAM. 1.3M Resolution and Quality Enhancement 64GB. Audio. IR for. Two-Way

Cond-IS RF Conducted Immunity System

8/16 Channel Elite-2 NVR

Waveguide Access Point WGA631. Product Guide

PE6108/PE6208/PE8108/PE8208

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

AirCam POE-200HD. H MegaPixel POE Dome. H.264 Compression. 1.3 Mega-Pixel Video Quality

T200, PTP/IEEE 1588 Grandmaster Clock and

OD-325HD-2.5MM. H.264 MegaPixel Outdoor 25M IR Night vision POE Camera. H.264 Compression. IP66 Waterproof Resistance

Network Video Recorder Quick Operation Guide

AXIS 262+ Network Video Recorder

Zoom Network camera, PoE 802.3af, IR LEDs, 2-Megapixel, Day & Night, Outdoor

Impedance 50 (75 connectors via adapters)

20675 Manhattan Place Torrance CA USA T: F:

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

IP-200PHD Mega-Pixels. 2.0 Mega Pixel Passive PoE IPCamera. High Quality 2.0 MegaPixel Image. Easy to Install. 1600x1200 Pixels.

Report No R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894

E13. 5MP Cube with Basic WDR, Fixed lens Hardware User s Manual. (PoE) Ver. 2012/10/22

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

POWERED BY. EPCOM Slim Line. Powered by Hikvision. Technical Specification

Data Loggers for Real Time Temperature Monitoring - WiFi

Transcription:

Page: 2 of 71 Contents 1. Applicant information...3 2. Laboratory information...4 3. Test system configuration...5 3.1 Operation environment...5 3.2 Measurement Uncertainty...6 4. Description of E.U.T...7 4.1 General information...7 4.2 Product description...8 4.3 Auxiliary equipments...9 4.4 Test configuration... 10 4.5 Operating conditions...11 5. Summary of test results... 12 5.1 Summary of EMI emission test results... 12 5.2 Summary of immunity test results... 12 5.3 Performance criteria... 13 6. Test results... 15 6.1 Conducted Emission... 15 6.2 Radiated Emission... 23 6.3 Harmonics... 31 6.4 Flicker... 36 6.5 Electrostatic Discharge... 39 6.6 Radio Frequency Electromagnetic Fields... 44 6.7 Electric Fast Transient/BURST... 47 6.8 Surge... 50 6.9 Conducted Immunity... 53 6.10 Dips and Interruptions... 56 6.11 Mains supply voltage variations... 58 7. E.U.T. photographs... 59

Page: 3 of 71 1. Applicant information Applicant: Samsung Techwin Co., Ltd. Address: #42 Seongju-Dong, Changwon-Shi, Kyungsangnam-Do, Korea Telephone: +82-70-7147-8361 Fax: +82-31-277-2784 E-mail: js2002.kang@samsung.com Contact name: Kang Jei Soon Manufacturer#1: Samsung Techwin Co., Ltd. Address: #42 Seongju-Dong, Changwon-Shi, Kyungsangnam-Do, Korea Telephone: +82-70-7147-8361 Fax: +82-31-277-2784 E-mail: js2002.kang@samsung.com Contact name: Kang Jei Soon Manufacturer#2: Address: TIANJIN SAMSUNG TECHWIN OPTO-ELECTRONIC CO., LTD No.11 Weiliu Road. Micro-Electronic Industrial Park Jingang Road Tianjin 300385, China

Page: 4 of 71 2. Laboratory information Address EMC compliance Ltd. 480-5 Sin-dong, Yeongtong-gu, Suwon-city, Gyeonggi-do, 443-390, Korea Telephone Number: 82 31 336 9919 Facsimile Number: 82 505 299 8311 FCC CAB.: KR0040 VCCI Registration No. : R-3327, G-198, C-3706, T-1849 Industry Canada Registration No. : 8035A KOLAS NO.: 231 SITE MAP Suwon city EMC compliance

Page: 5 of 71 3. Test system configuration 3.1 Operation environment Temperature Humidity Pressure Chamber(10 m) : 24 C 38 % R.H. - Shielded room(ce) : 25 C 46 % R.H. - Shielded room(esd) : 23 C 50 % R.H. 99.9 kpa Test site These testing items were performed following locations; Test item Test site Conducted Emission Shielded Room Radiated Emission 10 m Chamber Harmonics current Immunity area Voltage fluctuations and flickers Immunity area Electrostatic discharge Shielded Room Radiated RF immunity Fully anechoic chamber (3 m) Electric Fast Transient/BURST Shielded Room Surge Shielded Room Conducted RF immunity Shielded Room Voltage dip/interruption Shielded Room Mains supply voltage variations Shielded Room

Page: 6 of 71 3.2 Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are test receiver, cable loss, antenna factor calibration, Antenna directivity, antenna factor variation with height, antenna phase center variation, antenna frequency interpolation, measurement distance variation, site imperfection, mismatch, and system repeatability. Based on CISPR 16-4-2, the measurement uncertainty level with a 95 % confidence level was applied. Conducted emission measurement (C.L: Approx 95 %, k = 2) Shielded Room (CE#1) Shielded Room (CE#2) Shielded Room (CE#3) 9 khz ~ 150 khz: ± 3.82 db 150 khz ~ 30 MHz: ± 3.43 db 9 khz ~ 150 khz: ± 3.82 db 150 khz ~ 30 MHz: ± 3.43 db 9 khz ~ 150 khz: ± 4.00 db 150 khz ~ 30 MHz: ± 3.63 db Radiated Emission measurement (C.L: Approx 95 %, k = 2) 10 m Chamber (#F4) 10 m Chamber (#F2) 30 MHz ~ 300 MHz 300 MHz ~ 1 000 MHz 3 m: + 4.56 db, - 4.58 db 10 m: + 4.56 db, - 4.56 db 3 m: + 4.84 db, - 4.85 db 10 m: + 4.71 db, - 4.72 db 1 GHz ~ 6 GHz 3 m: + 6.19 db, - 6.20 db 30 MHz ~ 300 MHz 300 MHz ~ 1 000 MHz 3 m: + 4.86 db, - 4.88 db 10 m: + 4.86 db, - 4.86 db 3 m: + 4.98 db, - 4.99 db 10 m: + 4.85 db, - 4.87 db 1 GHz ~ 6 GHz 3 m: + 6.19 db, - 6.20 db Radio Frequency Electromagnetic Fields (C.L: Approx 95 %, k = 2) ± 1.82 db Disturbance power Electromagnetic Fields (C.L: Approx 95 %, k = 2) ± 3.73 db

Page: 7 of 71 4. Description of E.U.T. 4.1 General information Display Network Camera Inputs Max. 64CH Resolution Protocols CIF ~ 5MP Onvif(Samsung, Axis, Sony, Panasonic, Vivotek), Samsung(SVNP) Live Local Display HDMI/VGA Multi-Channel Display [Local Monitor] 1 / 4 / 9 / 16 / Auto Seauence (4 page view) [Web] 1 / 4 / 9 / 16 / 32 / 64 / Auto Sequence Performance Operating System Embedded Linux Record Compression H.264, MPEG-4, MJPEG Recording Bandwidth Resolution Type Event Trigger Event Action 400Mbps(2MP 64camera real-time recording) CIF ~ 5MP Normal, Scheduled, Event (Pre/Post) - Alarm Input(8) - Video Loss - Camera Event(Sensor, MD, Video Analytics) - Internal VA(upto 16ch selectable, Advanced MD, Object Classfication(People, Car, Anything, Color(TBD)) e-mail, PTZ Preset, Alarm Out, Buzzer, Monitor Out Search & Play Playback Bandwidth 100Mbps(16ch simultaneously) Mode Date & Time(Calendar)/Event Log list Simultaneous playback 16 channels(local Monitor) 64 ch(web, CMS) Resolution CIF ~ 5MP Playback Control Fast Forward/Fast Backward, Move one step up/move one step down Storage Built-In N/A Extended External(DAS) External(NAS) RAID 12 (Hot Swap) N/A NAS(iSCSI) : vessraid 1840i RAID-5/6 Backup File backup(via Web) BU/Exe(GUI), JPG, AVI(Network) Function Singlei channel Play, Date-Time/Title display Sensor I/O 8/4 (NO/NC Selectable) Audio Input 64 channels (network) Network Interface Protocol DDNS Transmission Bandwidth Max Remote Users IP Version Security Compression G.711, G.726 Audio Communication 2-Way RJ-45, Gigabit Ethernet x4 TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTSP, NTP, HTTP, DHCP, PPPoE, SMTP, ICMP, IGMP, ARP, DNS, DDNS, upnp, ONVIF, HTTPS, SNMP, ONVIF Samsung ipolis DDNS MAX 400Mbps, Unlimited/2/1.5/1 Mbps,800/600/500/400/300/ 200/100/50kbps Search(3) / Live unicast(10) / Live multicast(20) IPv4/v6 User access Log IP Filtering 802.1x Encryption Web Viewer Language English, French, German, Spanish, Italian, Chinese, Korean, Russian, Japanese, Swedish, Denish, Portuguese, Czech, Polish, Turkish, Rumanian, Serbian, Dutch, Croatian, Hungarian, Greek, Finnish, Norwegian OS Supported OS : Window XP(service pack 2 or above), Vista, 7, 8, Mac OS X(10.4.8 or above), 64bit Web Browser MS IE 7.x, 8.x, 9.x, Google Chrome, Safari, Firefox 2.x, 3.x Viewer Software Type SSM., Webviewer, Smart Viewer CMS Support Support SDK/CGI

Page: 8 of 71 Functions Camera Setup Register Auto, Manual Setup Items - IP Address, Add Profile Edit, Bitrate, Compression, GOP, Quality - Video Setup(MD, VA, ABF, Brightness/Contrast, Flip/Mirror, IRIS, WDR, D&N, SSNR, Shutter) PTZ Control Via Webviewer Preset 256 Presets Smart phone Support Model I-Phone, Android Indicator/Interface Control Live(4ch) / Playback(1ch) Front Indicator HDD Action LED 12EA, RAID Status LED 3EA Switch PWR Switch 1EA Key-Lock 1EA Connectors VGA 1 EA HDMI Audio DVD Serial Ethernet Alarm USB 1 EA Out(1EA, RCA, Line) N/A N/A RJ-45(4EA, GbE) w/ LINK/ACT LED In(8EA, Terminal Block) Out(4EA, Terminal Block) 2EA Reset Switch(1EA) Power Cord 2x AC Inlet System Log Log List Max. 20000 (System Log, Event Log each) Environmental Operating Temperature / Humidity Humidity Electrical Power Power Consumption Mechanical Color / Material Dimension (WxHxD) Weight Standards Regulation +0 C to +40 C 20% ~ 85% 100 to 240 VAC ±10%; 50/60 Hz, 4~1.5A(Dual SMPS) TBD Black / Metal W440.0 x H132.0 x D426.8 mm (3U) TBD R82(France), EN-50132 Approvals Safety UL,KC EMC CE, FCC, KCC, CCC, Gost-R

Page: 9 of 71 4.2 Product description Type of product Model name (Basic) Network Video Recorder SRN-4000P Model name (Variant) - Difference - Trade name - Serial no Testing voltage Product rating Internal clock frequency Engineering Sample 230 V, 50 Hz AC 100-240 V, 50 / 60 Hz Above 108 MHz Note - 4.3 Auxiliary equipments Type Model / Part # Serial number Manufacturer Note PC Xnote - LG Monitor CF23MS NC07H1KZ602039A SAMSUNG USB Mouse 1 1088 8165900106545 Microsoft USB Mouse 2 1088 8165906051226 Microsoft USB Mouse 3 1088 8165906050941 Microsoft Headset SHS-250V - SAMSUNG JIG - - - Camera SCO-2370 - Samsung Techwin Video Converter IPE-1600R - Samsung Techwin

Page: 10 of 71 4.4 Test configuration Note * 1 Start End Cable Length Name I/O port Name I/O port Spec. (m) Power 1,2 AC Main 1,2 Power 1,2 1.4 Non-Shield - 2 USB 1,2 USB Mouse 1,2 USB 1,2 1.8 Shield - 3 LAN 1(RJ-45) Video Converter LAN(RJ-45) 3.0 Non-Shield - Cable 4 LAN 3(RJ-45) Note PC LAN(RJ-45) 3.0 Non-Shield - EUT 5 (Network LAN 2,4(RJ-45) Open - 3.0 Non-Shield - 6 Video Audio Out Monitor Audio In 3.0 Shield Out-door Recorder) 7 HDMI Monitor HDMI 1.6 Shield - 8 D-SUB Monitor D-SUB 1.4 Shield - 9 Alarm In/Out JIG Alarm In/Out 3.0 Non-Shield Out-door 10 Serial Open - 1.4 Non-Shield - 11 Video Converter Video In Camera Video Out 2.0 Shield - 12 USB USB Mouse 3 USB 1.8 Shield - Note PC 13 MIC/SPK Headset MIC/SPK 2.0 Non-Shield -

Page: 11 of 71 4.5 Operating conditions The EUT was configured as normal intended use. Test mode HDMI Mode, D-SUB Mode Normal operating Web viewer camera monitoring test. Ping test. Alarm test. (Used JIG)

Page: 12 of 71 5. Summary of test results 5.1 Summary of EMI emission test results Applied Test items Test method Result Conducted Emission EN 55022:2010 Radiated Emission EN 55022:2010 Harmonics current EN 61000-3-2:2006+A2:2009 Voltage fluctuations and flickers EN 61000-3-3:2008 5.2 Summary of immunity test results Applied Test items Test method Result * EN 50130-4:2011 Electrostatic discharge EN 61000-4-2:2009 Radiated RF immunity EN 61000-4-3:2006+A2:2010 Electric Fast Transient/BURST EN 61000-4-4:2004+A1:2010 Surge EN 61000-4-5:2006 Conducted RF immunity EN 61000-4-6:2009 Voltage dip/interruption EN 61000-4-11:2004 Mains supply voltage variations EN 50130-4:2011

Page: 13 of 71 5.3 Performance criteria The variety and the diversity of the apparatus within the scope of this document makes it difficult to define precise criteria for the evaluation of the immunity test results. If as a result of the application of the tests defined in this standard, the apparatus becomes dangerous or unsafe then the apparatus shall be deemed to have failed the test. A functional description and a definition of performance by the manufacture and noted in the test report, based on the following criteria: Electrostatic discharge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, Radiated electromagnetic fields There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, and no such Flickering of indicators occurs at a field strength of 3 V/m. For components of CCTV systems, where the picture is allowed at 10 V/m, providing. (a) there is no permanent damage or change to EUT (e.g. no corruption of memory or changes to programmable setting etc.) (b) at 3 V/m, any deterioration of the picture is so minor that the system could still be used; and (c) there is no observable deterioration of the picture at 1 V/m. Fast transient burst / slow high energy voltage surge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as

Page: 14 of 71 Conducted RF immunity There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators oeuvres at U = 130 dbμv. For component of CCTV systems, where the status is monitored by observing the TV picture, then deterioration of the picture is allowed at U = 140 dbμv, providing: (a) there is no permanent damage or change to the EUT (e.g. no corruption of memory or changes to programmable settings etc.) (b) at U = 130 dbμv, any deterioration of the picture is so minor that the system could still be used; and (c) there in no observable deterioration of the picture at U = 120 dbμv. Voltage dip/interruption / Voltage variation There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the conditioning is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change. The EUT shall meet the acceptance criteria for the functional test, after the conditioning.

Page: 15 of 71 6. Test results 6.1 Conducted Emission Test specification Testing voltage Test facility EN 55022:2010, Class A 230 V, 50 Hz Shielded room (CE#1) Date 2013. 08. 16 Temperature ( C) 25 C Humidity (% R.H.) 46 % R.H. Remarks 6.1.1 Limits of conducted emission measurement AC main Frequency Class A (db(μv)) Class B (db(μv)) [MHz] Quasi-peak Average Quasi-peak Average 0.15 ~ 0.5 79 66 66 ~ 56 * 56 ~ 46* 0.5 ~ 5 73 60 56 46 5 ~ 30 73 60 60 50 *The limit decreases linearly with the logarithm of frequency. Telecommunication Frequency [MHz] Class A Voltage Limits (db(μv)) Current Limits (db(μa)) Quasi-Peak Average Quasi-Peak Average 0.15 ~ 0.5 97 to 87 84 to 74 53 to 43 40 to 30 0.5 ~ 30 87 74 43 30 Frequency [MHz] Class B Limits (db(μv)) Current Limits (db(μa)) Quasi-Peak Average Quasi-Peak Average 0.15 ~ 0.5 84 to 74 74 to 64 40 to 30 30 to 20 0.5 ~ 30 74 64 30 20 * The limits decrease linearly with the logarithm of the frequency in the range 0.15 MHz to 0.5 MHz * The current and voltage disturbance limits are derived for use with an impedance stabilization Network (ISN) which presents a common mode (asymmetric mode) impedance of 150 Ω to the telecommunication port under test (conversion factor is 20 log 10 150/I = 44 db).

Page: 16 of 71 6.1.2 Measurement procedure The measurements were performed in a shielded room. EUT was setup as shown in photograph and placed on a non-metallic table height of 0.8 m above the reference ground plane. The rear of table was located 0.4 m to the vertical conducted plane. EUT was power through the LISN, which was bonded to the ground plane. The LISN power was filtered. Each EUT power lead, except ground (safety) lead was individually connected through a LISN to input power source. EUT signal cables that hung closer than 0.4 m to the Horizontal metal ground 0.3 m ~ 0.4 m long. The power cord was bundles in the center. All peripheral equipment was powered from a sub LISN. The LISN and ISN were positioned 0.8 m from the EUT. Peak and Average detection were used in preliminary testing and Quasi-peak and Average detections were used at final measurement. Both lines of power cord, hot and neutral, were measured. 6.1.3 Used equipments Equipment Model Serial No. Makers Next Cal. Date Used Test Receiver ESHS30 828765/009 R&S 2013.10.22 Test Receiver ESCI7 100732 R&S 2014.02.18 Test Receiver ESCI 100001 R&S 2014.07.25 Test Receiver ESCI 100710 R&S 2013.11.06 LISN ENV216 101358 R&S 2013.10.22 LISN ESH3-Z5 100267 R&S 2014.07.08 8-WIRE ISN NTFM 8158 CAT5 CAT5-8158-0048 SCHWARZBECK 2013.10.30 8-WIRE ISN NTFM 8158 CAT3 CAT3-8158-0033 SCHWARZBECK 2013.10.30 ISN ST08 24342 TESEQ 2014.06.21 ISN ENY81 101545 R&S 2013.08.29

Page: 17 of 71 6.1.4 Photographs of test setup * AC Main

Page: 18 of 71 * Telecommunication

Page: 19 of 71 6.1.5 Conducted emission measurement result * AC Main (Power 1,2)_HDMI Mode (SRN-4000P) EMC Compliance.Ltd Shieldroom Serial : Operator : AC Power : 230V 50Hz Temp,Humidity: [db(uv)] 90 Level 80 70 60 50 40 30 <<Conducted Emission>> Standard Model : CISPR 22 : Class A Remark1 Remark2 : : Remark3 : Remark4 : <CISPR22 A> Limit (PK) Limit (AV) <CE_HDMI> Spectrum (N,AV) Spectrum (N,PK) Spectrum (L1,AV) Spectrum (L1.PK) Suspected Item(N) Suspected Item(L1) Final Item-QP(N) Final Item-CAV(N) Final Item-QP(L1) Final Item-CAV(L1) 20 10 0 5.000 10.000.150 30.000 Frequency [MHz] Final Result --- N Phase --- No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP CAV QP CAV QP AV QP CAV [MHz] [db(uv)] [db(uv)] [db] [db(uv)] [db(uv)] [db(uv)] [db(uv)] [db] [db] 1 0.6391 29.1 23.7 9.8 38.9 33.5 73.0 60.0 34.1 26.5 2 0.9815 37.7 37.0 9.7 47.4 46.7 73.0 60.0 25.6 13.3 3 1.21718 30.3 23.7 9.6 39.9 33.3 73.0 60.0 33.1 26.7 4 1.86702 29.4 21.1 9.6 39.0 30.7 73.0 60.0 34.0 29.3 5 8.02444 29.7 21.2 9.8 39.5 31.0 73.0 60.0 33.5 29.0 6 8.56568 27.7 20.7 9.7 37.4 30.4 73.0 60.0 35.6 29.6 --- L1 Phase --- No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP CAV QP CAV QP AV QP CAV [MHz] [db(uv)] [db(uv)] [db] [db(uv)] [db(uv)] [db(uv)] [db(uv)] [db] [db] 1 0.98112 37.5 36.6 9.7 47.2 46.3 73.0 60.0 25.8 13.7 2 0.98126 37.7 36.9 9.7 47.4 46.6 73.0 60.0 25.6 13.4 3 2.49992 29.1 21.8 9.6 38.7 31.4 73.0 60.0 34.3 28.6 4 8.12578 30.1 22.2 9.8 39.9 32.0 73.0 60.0 33.1 28.0 5 8.18512 29.6 21.4 9.8 39.4 31.2 73.0 60.0 33.6 28.8 6 14.71346 28.9 17.6 9.8 38.7 27.4 73.0 60.0 34.3 32.6

Page: 20 of 71 * AC Main (Power 1,2)_D-SUB Mode (SRN-4000P) EMC Compliance.Ltd Shieldroom Serial : Operator : AC Power : 230V 50Hz Temp,Humidity: [db(uv)] 90 Level 80 70 60 50 40 30 <<Conducted Emission>> Standard Model : CISPR 22 : Class A Remark1 Remark2 : : Remark3 : Remark4 : <CISPR22 A> Limit (PK) Limit (AV) <CE_D-SUB> Spectrum (N,AV) Spectrum (N,PK) Spectrum (L1,AV) Spectrum (L1.PK) Suspected Item(N) Suspected Item(L1) Final Item-QP(N) Final Item-CAV(N) Final Item-QP(L1) Final Item-CAV(L1) 20 10 0 5.000 10.000.150 30.000 Frequency [MHz] Final Result --- N Phase --- No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP CAV QP CAV QP AV QP CAV [MHz] [db(uv)] [db(uv)] [db] [db(uv)] [db(uv)] [db(uv)] [db(uv)] [db] [db] 1 0.98132 37.0 36.0 9.7 46.7 45.7 73.0 60.0 26.3 14.3 2 0.98458 36.6 35.2 9.7 46.3 44.9 73.0 60.0 26.7 15.1 3 7.16116 23.9 16.0 9.8 33.7 25.8 73.0 60.0 39.3 34.2 4 8.34882 29.4 21.4 9.8 39.2 31.2 73.0 60.0 33.8 28.8 5 14.11922 26.7 17.1 9.8 36.5 26.9 73.0 60.0 36.5 33.1 6 18.2808 22.6 17.1 9.8 32.4 26.9 73.0 60.0 40.6 33.1 --- L1 Phase --- No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP CAV QP CAV QP AV QP CAV [MHz] [db(uv)] [db(uv)] [db] [db(uv)] [db(uv)] [db(uv)] [db(uv)] [db] [db] 1 0.9812 36.6 35.5 9.7 46.3 45.2 73.0 60.0 26.7 14.8 2 0.9822 37.3 36.3 9.7 47.0 46.0 73.0 60.0 26.0 14.0 3 1.69088 30.9 22.0 9.6 40.5 31.6 73.0 60.0 32.5 28.4 4 8.07528 30.2 22.0 9.8 40.0 31.8 73.0 60.0 33.0 28.2 5 13.79566 21.4 13.1 9.8 31.2 22.9 73.0 60.0 41.8 37.1 6 20.06862 25.1 19.4 9.8 34.9 29.2 73.0 60.0 38.1 30.8

Page: 21 of 71 * Telecommunication port (SRN-4000P) * LCL 55 db (RJ-45 Port)_10Mbps EMC Compliance.Ltd Shieldroom Serial : Operator : AC Power : 230V 50Hz Temp,Humidity: [db(uv)] 110 Level 100 90 80 70 60 50 <<Conducted Emission>> Standard Model : CISPR 22 : Class A Remark1 Remark2 : : Remark3 : Remark4 : <KN22 Class A TEL> Limit (PK) Limit (AV) <CE_TEL LINE_10Mbps> Spectrum (AV) Spectrum (PK) Suspected Item(No Title1) Final Item-QP(No Title1) Final Item-AV(No Title1) 40 30 20 10 0 5.000 10.000.150 30.000 Frequency [MHz] Final Result --- ISN-CAT3 Phase --- No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP CAV QP CAV QP AV QP CAV [MHz] [db(uv)] [db(uv)] [db] [db(uv)] [db(uv)] [db(uv)] [db(uv)] [db] [db] 1 0.9813 36.8 36.2 9.8 46.6 46.0 87.0 74.0 40.4 28.0 2 2.50016 41.0 30.5 9.7 50.7 40.2 87.0 74.0 36.3 33.8 3 3.6971 37.9 27.6 9.7 47.6 37.3 87.0 74.0 39.4 36.7 4 3.80528 34.9 25.4 9.7 44.6 35.1 87.0 74.0 42.4 38.9 5 7.48698 42.3 19.8 9.8 52.1 29.6 87.0 74.0 34.9 44.4 6 11.20328 39.1 25.5 9.6 48.7 35.1 87.0 74.0 38.3 38.9 7 12.50022 58.4 47.2 9.6 68.0 56.8 87.0 74.0 19.0 17.2 8 20.60594 32.9 27.5 9.7 42.6 37.2 87.0 74.0 44.4 36.8

Page: 22 of 71 * LCL 65 db (RJ-45 Port)_100Mbps EMC Compliance.Ltd Shieldroom Serial : Operator : AC Power : 230V 50Hz Temp,Humidity: [db(uv)] 110 Level 100 90 80 70 60 50 <<Conducted Emission>> Standard Model : CISPR 22 : Class A Remark1 Remark2 : : Remark3 : Remark4 : <CISPR22 A_TEL> Limit (PK) Limit (AV) <CE_TEL LINE_100Mbps> Spectrum (AV) Spectrum (PK) Suspected Item(No Title2) Final Item-QP(No Title2) Final Item-AV(No Title2) 40 30 20 10 0 5.000 10.000.150 30.000 Frequency [MHz] Final Result --- ISN-CAT5 Phase --- No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP CAV QP CAV QP AV QP CAV [MHz] [db(uv)] [db(uv)] [db] [db(uv)] [db(uv)] [db(uv)] [db(uv)] [db] [db] 1 0.98072 36.7 36.1 9.7 46.4 45.8 87.0 74.0 40.6 28.2 2 0.98198 36.6 36.0 9.7 46.3 45.7 87.0 74.0 40.7 28.3 3 13.41908 45.0 41.9 9.8 54.8 51.7 87.0 74.0 32.2 22.3 4 14.12108 27.7 19.0 9.8 37.5 28.8 87.0 74.0 49.5 45.2 5 16.22738 47.0 44.1 9.8 56.8 53.9 87.0 74.0 30.2 20.1 6 21.03156 33.3 26.9 9.8 43.1 36.7 87.0 74.0 43.9 37.3 7 21.67914 29.6 24.0 9.8 39.4 33.8 87.0 74.0 47.6 40.2 8 26.54856 45.7 42.2 9.8 55.5 52.0 87.0 74.0 31.5 22.0

Page: 23 of 71 6.2 Radiated Emission Test specification Testing voltage Test facility Test distance EN 55022:2010, Class A 230 V, 50 Hz 10 m Chamber (#F2) 10 m, 3 m Date 2013. 08. 16 Temperature ( C) 24 C Humidity (% R.H.) 38 % R.H. Remarks 6.2.1 Limits of radiated emission measurement Limits below 1 GHz Frequency [MHz] Class A (db(μv/m)) @ 10 m Class B (db(μv/m)) @ 10 m 30 ~ 230 40 30 230 ~ 1 000 47 37 Limits above 1 GHz Class A @ 3 m Class B @ 3 m Frequency Average limit Peak limit Average limit Peak limit [GHz] (db(μv/m)) (db(μv/m)) (db(μv/m)) (db(μv/m)) 1 ~ 3 56 76 50 70 3 ~ 6 60 80 54 74 Note - The lower limit applies at the transition frequency. 6.2.2 Measurement procedure The test was done at a 10 m chamber with a quasi-peak detector. EUT was placed on a non-metallic table height of 0.8 m above the reference ground plane. Cables were folded back and forth forming a bundle 0.3 m to 0.4 m long and were hanged at a 0.4 m height to the ground plane. Cables connected to EUT were fixed to cause maximum emission. Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.

Page: 24 of 71 6.2.3 Used equipments Equipment Model no. Serial no. Makers Next Cal. Date Used Test Receiver ESCI7 100732 R&S 2014.02.18 Test Receiver ESCI 100001 R&S 2014.07.25 Test Receiver ESCI 100710 R&S 2013.11.06 Bi-Log Antenna VULB 9168 440 SCHWARZBECK 2013.10.04 Amplifier 310N 293004 SONOMA INSTRUMENT 2013.11.06 3 db Attenuator 8491B 22981 HP 2014.03.19 Antenna Mast MA4000-EP 303 Innco Systems - Turn Table DT2000S-1t 079 Innco Systems - Amplifier 8449B 3008A02343 AGILENT 2013.11.06 Horn ANT 3115 00155772 ETS 2015.03.20 Spectrum Analyzer FSP7 100289 R&S 2013.12.14 6.2.4 Sample calculation The field strength is calculated adding the antenna Factor, cable loss and, Antenna pad adding, subtracting the amplifier gain from the measured reading. The sample calculation is as follow: Result = M.R + C.F(A.F + C.L +3 db Att A.G) M.R = Meter Reading C.F = Correction Factor A.F = Antenna Factor C.L = Cable Loss A.G= Amplifier Gain 3 db Att = 3 db Attenuator If M.R is 30 db, A.F 12 db, C.L 5 db, 3 db, A.G 35 db The result is 30 + 12 + 5 + 3 35 = 15 db(μv/m)

Page: 25 of 71 6.2.5 Photographs of test setup * 30 MHz ~ 1 GHz

Page: 26 of 71 * 1 GHz ~ 6 GHz

Page: 27 of 71 6.2.6 Radiated emission measurement result * Graph and Data * 30 MHz ~ 1 GHz (Power 1,2)_HDMI Mode (SRN-4000P) EMC Compliance Ltd. 10m Chamber Serial : Operator : AC Power : 230V 50Hz Temp,Humidity: [db(uv/m)] 60 50 40 <<Radiated Emission>> Standard Model : EN55022 : Class A 10m Remark1 : Remark2 : Remark3 : Remark4 : <EN55022 Class A> Limit(QP) <CE_HDMI> Spectrum(H,PK) Spectrum(V,PK) Suspected Item(H) Suspected Item(V) Final Item(H,QP) Final Item(V,QP) Level 30 20 10 0 30.0 1000.0 50.0 100.0 500.0 Frequency [MHz] Final Result No. Frequency (P) Reading c.f Result Limit Margin Height Angle Remark QP QP QP QP [MHz] [db(uv)] [db(1/m)] [db(uv/m)] [db(uv/m)] [db] [cm] [deg] 1 31.576 V 43.6-15.1 28.5 40.0 11.5 400.0 193.4 2 93.171 V 46.9-18.3 28.6 40.0 11.4 100.0 236.9 3 124.939 V 41.4-14.2 27.2 40.0 12.8 100.0 212.9 4 150.159 H 41.4-12.4 29.0 40.0 11.0 400.0 212.4 5 206.904 V 47.3-14.6 32.7 40.0 7.3 100.0 355.2 6 300.024 V 49.7-10.4 39.3 47.0 7.7 100.0 355.2 7 499.965 V 37.9-4.5 33.4 47.0 13.6 100.0 16.6 8 875.112 H 32.5 3.7 36.2 47.0 10.8 100.0 176.3

Page: 28 of 71 * 1 GHz ~ 6 GHz (Power 1,2)_HDMI Mode (SRN-4000P) EMC Compliance Ltd. 10m Chamber Serial : Operator : AC Power : AC 230V / 50Hz Temp,Humidity: [db(uv/m)] 90 Level 80 70 60 50 40 <<Radiated Emission>> Standard Model : CISPR Pub.22 : Class A GHz 3m Remark1 : Remark2 : Remark3 : Remark4 : <CISPR 22 A GHz 3m> Limit(AV) Limit(PK) <CE_HDMI_SVSWR> Spectrum(H,PK) Spectrum(V,PK) Suspected Item(H) Suspected Item(V) Final Item(H,AV) Final Item(H,PK) Final Item(V,AV) Final Item(V,PK) 30 20 10 0 3000.0 4000.01000.0 5000.0 6000.0 Frequency [MHz] Final Result No. Frequency (P) Reading Reading c.f Result Result Limit Limit Margin Margin Height Angle Remark AV PK AV PK AV PK AV PK [MHz] [db(uv)] [db(uv)] [db(1/m)] [db(uv/m)] [db(uv/m)] [db(uv/m)] [db(uv/m)] [db] [db] [cm] [deg] 1 1019.375 H 35.7 56.0-8.9 26.8 47.1 56.0 76.0 29.2 28.9 100.0 37.3 2 1374.375 H 36.2 52.4-5.3 30.9 47.1 56.0 76.0 25.1 28.9 100.0 16.3 3 1500.000 V 34.8 54.1-4.5 30.3 49.6 56.0 76.0 25.7 26.4 100.0 29.2 4 1680.000 V 36.3 55.8-3.3 33.0 52.5 56.0 76.0 23.0 23.5 100.0 170.2

Page: 29 of 71 * 30 MHz ~ 1 GHz (Power 1,2)_D-SUB Mode (SRN-4000P) EMC Compliance Ltd. 10m Chamber Serial : Operator : AC Power : 230V 50Hz Temp,Humidity: [db(uv/m)] 60 50 40 <<Radiated Emission>> Standard Model : EN55022 : Class A 10m Remark1 : Remark2 : Remark3 : Remark4 : <EN55022 Class A> Limit(QP) <CE_D-SUB> Spectrum(H,PK) Spectrum(V,PK) Suspected Item(H) Suspected Item(V) Final Item(H,QP) Final Item(V,QP) Level 30 20 10 0 30.0 1000.0 50.0 100.0 500.0 Frequency [MHz] Final Result No. Frequency (P) Reading c.f Result Limit Margin Height Angle Remark QP QP QP QP [MHz] [db(uv)] [db(1/m)] [db(uv/m)] [db(uv/m)] [db] [cm] [deg] 1 31.698 V 43.6-15.1 28.5 40.0 11.5 400.0 321.5 2 120.210 H 38.1-14.7 23.4 40.0 16.6 400.0 47.9 3 124.939 V 43.5-14.2 29.3 40.0 10.7 100.0 257.5 4 152.220 H 40.0-12.3 27.7 40.0 12.3 400.0 212.8 5 171.378 H 36.5-12.6 23.9 40.0 16.1 400.0 89.8 6 208.238 V 46.7-14.5 32.2 40.0 7.8 100.0 6.2 7 300.024 V 53.0-10.4 42.6 47.0 4.4 100.0 10.4 8 841.648 H 34.4 3.0 37.4 47.0 9.6 100.0 259.1

Page: 30 of 71 * 1 GHz ~ 6 GHz (Power 1,2)_D-SUB Mode (SRN-4000P) EMC Compliance Ltd. 10m Chamber Serial : Operator : AC Power : AC 230V / 50Hz Temp,Humidity: [db(uv/m)] 90 Level 80 70 60 50 40 <<Radiated Emission>> Standard Model : CISPR Pub.22 : Class A GHz 3m Remark1 : Remark2 : Remark3 : Remark4 : <CISPR 22 A GHz 3m> Limit(AV) Limit(PK) <CE_D-SUB_SVSWR> Spectrum(H,PK) Spectrum(V,PK) Suspected Item(H) Suspected Item(V) Final Item(H,AV) Final Item(H,PK) Final Item(V,AV) Final Item(V,PK) 30 20 10 0 3000.0 4000.01000.0 5000.0 6000.0 Frequency [MHz] Final Result No. Frequency (P) Reading Reading c.f Result Result Limit Limit Margin Margin Height Angle Remark AV PK AV PK AV PK AV PK [MHz] [db(uv)] [db(uv)] [db(1/m)] [db(uv/m)] [db(uv/m)] [db(uv/m)] [db(uv/m)] [db] [db] [cm] [deg] 1 1019.375 V 32.9 48.4-8.9 24.0 39.5 56.0 76.0 32.0 36.5 100.0 50.2 2 1500.000 V 38.4 55.2-4.5 33.9 50.7 56.0 76.0 22.1 25.3 100.0 50.2 3 1680.000 H 36.2 54.6-3.3 32.9 51.3 56.0 76.0 23.1 24.7 100.0 155.5 4 3000.000 V 33.8 51.7 1.0 34.8 52.7 56.0 76.0 21.2 23.3 100.0 191.1

Page: 31 of 71 6.3 Harmonics Test specification Testing voltage Test facility EN 61000-3-2:2006+A2:2009 230 V, 50 Hz Immunity area Date 2013. 08. 20 Temperature( C) 26 C Humidity (% R.H.) 41 % R.H. Pressure (kpa) 100.2 kpa Remarks 6.3.1 Measurement procedure The equipment is supplied in serieswith shunt(s) Rmor current transformer(s) from asourcehaving thesame nominal voltage and frequency as the rated supplyvoltage and frequencyof the equipment. Measurements shallbemadeunder normal load, or conditionsfor adequateheat discharge, and under normaloperating conditions. User soperation controls or automaticprogrammers shall be set to produce themaximumharmonic component, for each successiveharmonic component in turn.for thepurposeof harmonic current limitation, equipment is classified asfollows : ClassA: Equipmentnot specified in one of the threeother Classesshallbe considered as ClassAequipment. - Balanced three-phaseequipment; - Household appliances excluding equipment identified as Class D; - Tools excludingportable tools; - Dimmers for incandescent lamps; - Audio equipment. Class B:Portable tools;arc welding equipmentwhich isnotprofessional equipment. Class C : Lighting equipment. Class D: Equipmenthaving aspecified power according to 6.2.2 less than or equal to 600 w,of thefollowing types: - Personal computers and personal computer monitors; - Television receivers.

Page: 32 of 71 6.3.2 Used equipments Equipment Model no. Serial no. Makers Harmonics/Flicker meter 5001x-CTS -400-413 Next Cal. date 54984 C.I. 2014.05.22 Used 6.3.3 Photographs of test setup

Page: 33 of 71 6.3.4 Measurement result

Page: 34 of 71

Page: 35 of 71

Page: 36 of 71 6.4 Flicker Test specification EN 61000-3-3:2008 Testing voltage 230 V, 50 Test facility Immunity area Date 2013. 08. 20 Temperature( C) 26 C Remarks Humidity (% R.H.) 41 % R.H. Pressure ( ) 100.2 6.4.1 Measurement procedure EUT was connected to the power analyzer system. Measurement was performed to obtain the desired flicker parameters. The measuring time depends on which parameters are to be measured. Plt =2h Pst = 10 min Controls and automatic programs shall be set to produce the most unfavorable sequence of voltage changes, using only those combinations of controls and programs are mentioned by the manufacturer in the instruction manual.

Page: 37 of 71 6.4.2 Used equipments Equipment Model no. Serial no. Makers Next Cal. date Harmonics/Flicker meter 5001x-CTS -400-413 54984 C.I. 2014.05.22 Used 6.4.3 Photographs of test setup

Page: 38 of 71 6.4.4 Measurement result

Page: 39 of 71 6.5 Electrostatic Discharge Test specification EN 61000-4-2:2009 Contact: ± 6 Air: ± 2, ± 4, ± 8 HCP: ± 2, ± 4, ± 6 VCP: ± 2, ± 4, ± 6 Test level Discharge impedance 330 Ω / 150 Number of discharge (Each polarity) Contact: 10 Air: 10 HCP / VCP: 10 Interval between discharges 1s Testing voltage 230 V, 50 Test facility Shielded room Date 2013. 08. 20 Temperature( C) 23 C Remarks - There was no change of operation status during above testing. Humidity (% R.H.) 50 % R.H. Pressure ( ) 99.9 6.5.1 Measurement procedure A ground reference plane was located on the floor, and connected to earth via a low Impedance connection. The return cable of the ESD generator was connected to the reference plane. In case of floor standing equipment, EUT was placed on the reference plane on 0.1 m of insulating Support. In case of table top equipment, EUT was placed on a wooden table 0.8 m above the reference grounded floor. A horizontal coupling plane (HCP) was placed on the table, and Connected to the reference plane via a 470 resistor located in each end (0.5 insulating support between EUT and HCP). In both cases a vertical coupling plane(vcp) OF 0.5 X 0.5 m was located 0.1 m from the EUT s sides. The VCP was connected to the reference plane in the same matter as the HCP.

Page: 40 of 71 6.5.2 Used equipments Equipment Model No. Serial No. Makers Next Cal. Date ESD Tester PESD 1600 H011 309 HAEFELY 2014.07.15 ESD Tester NSG 437 182 TESEQ 2014.05.21 HCP - - - - VCP - - - - Used 6.5.3 Photographs of test setup

Page: 41 of 71 6.5.4 Measurement result Electrostatic Discharge (Test Point) Air discharge Contact discharge

Page: 42 of 71

Page: 43 of 71 (Power 1,2_HDMI Mode, D-SUB Mode) HCP/VCP discharge Location(EUT) HCP (All 4 sides) VCP (All 4 sides) Contact discharge Location(EUT) C1 Enclosure(Case) C2 USB Port C3 Audio Out Port C4 D-SUB Port C5 HDMI Port C6 LAN(RJ-45) Port C7 Screw C8 Serial Port Air discharge Location(EUT) A1 LED Applied level (±) ± 2, ± 4, ± 6 ± 2, ± 4, ± 6 Result Applied level (±) ±6 ±6 ±6 ±6 ±6 ±6 ±6 ±6 Result Applied level (±) ± 2, ± 4, ± 8 Result A2 Button ± 2, ± 4, ± 8 A3 Enclosure(Case) ± 2, ± 4, ± 8 A4 Power Port ± 2, ± 4, ± 8 A5 Alarm In/Out Port ± 2, ± 4, ± 8 A6 Switch ± 2, ± 4, ± 8

Page: 44 of 71 6.6 Radio Frequency Electromagnetic Fields Test specification EN 61000-4-3:2006+A2:2010 Tested frequency 80 ~ 2.7 Test level & Modulation 1 V/m, 3 V/m, 10 V/m, 80 % Amplitude Modulation (1 ) 1 V/m, 3 V/m, 10 V/m, Pulse Modulation (1 (0.5s ON: 0.5s OFF)) Frequency Step log 1 % step Dwell time 3s Distance 3 m from EUT to tip of antenna Testing Voltage 230 V, 50 Test facility Fully anechoic chamber (3 m) Date 2013. 08. 19 Temperature( C) 27 C Remarks - There was no change of operation status during above testing. Humidity (% R.H.) 39 % R.H. Pressure ( ) 99.9 6.6.1 Measurement procedure The test was performed at 3 m full anechoic chamber. For floor standing equipment, the EUT was standing on the floor. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor. The EUT was tested all sides, horizontal and vertical polarization.

Page: 45 of 71 6.6.2 Used equipments Equipment Model no. Serial no. Makers Next Cal. date Power meter PM2002 302852 AR 2014.04.05 Power sensor PH2000 303224 AR 2014.04.05 Power sensor PH2000 311217 AR 2014.04.05 Directional coupler DC6180 303976 AR 2014.04.08 Directional coupler DC7144M1 320279 AR 2014.02.07 Signal generator E4421B GB40052295 AGILENT 2013.10.11 Amplifier BBA100 100996-1 R&S 2014.02.12 Amplifier 60S1G3M2 320444 AR 2014.04.09 Broadband Ant. LPDA-0803 130269 - Fiber Optic Modem HI-4413P - Antenna master - - ETS ETSLINDGREM ETS Used - 6.6.3 Photographs of test setup

Page: 46 of 71 6.6.4 Measurement result (Power 1,2_HDMI Mode, D-SUB Mode) Location(EUT) Front side Rear side Left side Right side Antenna polarization Horizontal Vertical Horizontal Vertical Result Horizontal Vertical Horizontal Vertical

Page: 47 of 71 6.7 Electric Fast Transient/BURST Test specification EN 61000-4-4:2004+A1:2010 Coupling AC main Signal: Clamp Telecommunication: Clamp Test level AC main: ± 2 Peak Signal: ± 1 Peak Telecommunication: ± 1 Peak Repetition frequency 100, Tr/Th = 5 / 50 Coupling time 60 s Testing Voltage 230 V, 50 Test facility Shielded room Date 2013. 08. 20 Temperature( C) 22 C Remarks - There was no change of operation status during above testing. Humidity (% R.H.) 50 % R.H. Pressure ( ) 100.2 6.7.1 Measurement procedure A ground reference plane was located on the floor. EFT generator was connected to reference ground plane via low impedance connection. For floor standing equipment, EUT was placed on a 0.1 m wooden table. For tabletop equipment, EUT was placed on a 0.1 m above the ground reference plane. Test generator and coupling/decoupling network was placed on, and bounded to, the ground reference plane. When using the coupling clamp, the minimum distance between the coupling plates and all other conductive surfaces, except the ground reference plane beneath the coupling clamp, Shall be 0.5 m. 6.7.2 Used equipments Equipment Model No. Serial No. Makers Next Cal. date Ultra compact simulator UCS 500-M V0545100858 EM TEST 2014.01.31 Ultra compact simulator UCS500M 0701-03 EM TEST 2014.06.21 Capacitive Coupling Clamp - - EM TEST - Used

Page: 48 of 71 6.7.3 Photographs of test setup

Page: 49 of 71 6.7.4 Measurement result * AC main (Power 1,2_HDMI Mode, D-SUB Mode) EFT coupling point (+) (-) Result L+N+PE +2-2 * Signal (Power 1,2_HDMI Mode, D-SUB Mode) EFT coupling point (+) (-) Result Audio Out +1-1 Alarm In/Out +1-1 * Telecommunication (Power 1,2_HDMI Mode, D-SUB Mode) EFT coupling point (+) (-) Result LAN(RJ-45) +1-1

Page: 50 of 71 6.8 Surge Test specification EN 61000-4-5:2006 AC main: Direct Signal: CDN Coupling Differential mode: ± 0.5, ± 1 AC main: Common mode: ± 0.5, ± 1, ± 2 Test level Signal: ± 0.5, ± 1 Differential mode: 18 40 Ω + 0.5 Coupling Impedance Common mode: 10 Ω + 9 Direct Surge pulse shape Tr/Th = 1.2 / 50 Angles 0, 90, 180, 270 Number of surge 5 Coupling time 1 min Testing Voltage 230 V, 50 Test facility Shielded room Date 2013. 08. 20 Temperature( C) 22 C Remarks - There was no change of operation status during above testing. Humidity (% R.H.) 50 % R.H. Pressure ( ) 100.2 6.8.1 Measurement procedure A ground reference plane was located on the floor. SURGE generator was connected to reference ground plane via low impedance connection. For floor standing equipment & table top equipment, EUT was placed on a wooden table. 6.8.2 Used equipments Equipment Model No. Serial No. Makers Next Cal. date Ultra compact simulator UCS 500-M V0545100858 EM TEST 2014.01.31 Ultra compact simulator UCS500M 0701-03 EM TEST 2014.06.21 CDN CNV 508 N1 V1108108861 EM TEST 2014.01.03 Used

Page: 51 of 71 6.8.3 Photographs of test setup

Page: 52 of 71 6.8.4 Measurement result * AC main (Power 1,2_HDMI Mode, D-SUB Mode) Coupling point (+) (-) Result L+N + 0.5, + 1-0.5, - 1 L+PE + 0.5, + 1, + 2-0.5, - 1, - 2 N+PE + 0.5, + 1, + 2-0.5, - 1, - 2 * Signal (Power 1,2_HDMI Mode, D-SUB Mode) Coupling point (+) (-) Result Audio Out + 0.5, + 1-0.5, - 1 Alarm In/Out + 0.5, + 1-0.5, - 1

Page: 53 of 71 6.9 Conducted Immunity Test specification EN 61000-4-6:2009 Tested frequency 0.15 ~ 100 Test level & Modulation 1 V, 3 V, 10 V, 80 % Amplitude Modulation (1 ) 1 V, 3 V, 10 V, Pulse Modulation (1 (0.5s ON: 0.5s OFF)) Frequency Step log 1 % step Coupling method AC main: CDN(M3) Signal:Clamp Telecommunication: CDN (T8-RJ45) Testing Voltage 230 V, 50 Test facility Shielded room Date 2013. 08. 19 Temperature( C) 23 C Remarks - There was no change of operation status during above testing. Humidity (% R.H) 52 % R.H Pressure( ) 100.0 6.9.1 Measurement procedure A ground reference plane was located on the floor. The test was performed on a ground reference plane on a 0.1 m wooden table. This test were Performed using CDN for mains, clamp for signal and injection probe. The frequency range was swept from 0.15 to 100. This frequency range was Modulated with 1 sine wave at 80 %. The signal generators provided the modulated frequency at a 1 % step size. The power and all network cable, I/O cables longer than 3 m length were tested.

Page: 54 of 71 6.9.2 Used equipments Equipment Model no. Serial no. Makers Next Cal. date CS generator CWS 500 V0635101750 EM TEST 2014.01.17 CS generator CWS500N1 V1041107702 EM TEST 2013.11.01 CDN CDN L-801 M2/M3 2936 EM TEST 2014.02.06 CDN CDN M2/M3 0906-12 EM TEST 2013.10.11 Attenuator 73-6-34 MU918 MCE/WEINSCHEL 2013.10.11 EM Clamp KEMZ 801 17643 Schaffner 2014.04.17 CDN CDN S1/75 0410-28 EM TEST 2014.05.13 CDN CDN-T8-RJ45 0113-22 EM TEST 2014.02.22 Used 6.9.3 Photographs of test setup

Page: 55 of 71 6.9.4 Measurement result * AC main (Power 1,2_HDMI Mode, D-SUB Mode) Coupling point Coupling method Power CDN(M3) Result * Signal (Power 1,2_HDMI Mode, D-SUB Mode) Coupling point Coupling method Result Audio Out Clamp Alarm In/Out Clamp * Telecommunication (Power 1,2_HDMI Mode, D-SUB Mode) Coupling point Coupling method Result LAN(RJ-45) CDN (T8-RJ45)

Page: 56 of 71 6.10 Dips and Interruptions Test specification EN 61000-4-11:2004 Number of dips 3T Duration 10 s Phase Zero crossing (0 ) Testing Voltage 100 V, 50 / 240 V, 50 Test facility Shielded room Test Date 2013. 08. 20 Temperature ( C) 22 C Remarks Humidity (% R.H.) 50 % R.H. Pressure ( ) 100.2 6.10.1 Measurement procedure The dips/interruption test is only applicable to AC mains. The dips/interruptions were applied at zero crossing. 6.10.2 Used equipments Equipment Model no. Serial no. Makers Next Cal. date Ultra compact simulator UCS 500-M V0545100858 EM TEST 2014.01.31 Ultra compact simulator UCS500M 0701-03 EM TEST 2014.06.21 Used

Page: 57 of 71 6.10.3 Photographs of test setup 6.10.4 Measurement result * 100 V, 50 / 240 V, 50 (Power 1,2_HDMI Mode, D-SUB Mode) Test Level (%UT) Dip/Int. (%UT) Duration /Period Phase ( ) Count number Result 80 % 20% 250 Period (1) 0 3T 70 % 30 % 25Period 0 3T 40 % 60 % 10 Period 0 3T 0% 100 % 250 Period (2) 0 3T Note* Comment: - There was no change of operation status during above testing. (250 Period (1), 25Period, 10 Period) - Note* (250 Period (2)) The power of EUT is off during the test. After the test, EUT is getting back to normal operation. It fully recorded using ancillary Power source equipment to content with Manufacturer`s set up manual.

Page: 58 of 71 6.11 Mains supply voltage variations Test specification EN 50130-4:2011 Supply voltage U nom + 10 %, U nom - 15 % Testing voltage 100 V, 50 / 240 V, 50 Date 2013. 08. 20 Temperature ( C) 22 C Remarks Humidity (% R.H.) 50 % R.H. Pressure ( ) 100.2 6.11.1 Used equipments Equipment Model no. Serial no. Makers Next Cal. date Ultra compact simulator UCS 500-M V0545100858 EM TEST 2014.01.31 Ultra compact simulator UCS500M 0701-03 EM TEST 2014.06.21 Used 6.11.2 Measurement result * 240 V, 50 (Power 1,2_HDMI Mode, D-SUB Mode) Supply voltage + 10 % 264 V - 15 % 204 V Result Comment: - There was no change of operation status during above testing. * 100 V, 50 (Power 1,2_HDMI Mode, D-SUB Mode) Supply voltage + 10 % - 15 % 110 V 85 V Result Comment: - There was no change of operation status during above testing.

Page: 59 of 71 7. E.U.T. photographs Front View

Page: 60 of 71 Rear View Left View

Page: 61 of 71 Right View Top View

Page: 62 of 71 Bottom View Port

Page: 63 of 71 Inside

Page: 64 of 71 Main Board

Page: 65 of 71 Front Board

Page: 66 of 71 HDD (1000 GB*12EA)

Page: 67 of 71 Terminal Board

Page: 68 of 71 Power*2EA

Page: 69 of 71

Page: 70 of 71

Page: 71 of 71