IH 17025 E Sigma Island 90



Similar documents
BLACK TIE. Instructions Manual

Cooktop Low-Profile Ventilation Hoods

3 IN 1 BATHROOM HEATER

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

Installation, operation and maintenance manual TX 35A

Portable Air Conditioner

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Safe Method: Gas Safety in Catering Establishments

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

PROFESSIONAL POPCORN MAKER

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Use and Care Manual. Model CPA12KH AIR CONDITIONER

WS-69TB30SS (22") WS-69TB36SS (22") WS-69TS30SS (18") WS-69TS36SS (18")

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

E D I T I O N

CARING FOR YOUR WATER HEATER

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

AIR CONDITIONER INSTALLATION MANUAL

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

ORLAND FOLLOW PR-1211

Ceramic Glass Electric Galley Ranges

ES Manual de instalación, uso y mantenimiento de campanas decorativas Handbuch zu Installation, Bedienung und Wartung von dekorativen Abzugshauben

TIPS ON ENERGY SAVING

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

Stove Guard Kit User Manual

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

INSTALLATION INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

GF SERIES 1-TANK/2-TANK ELECTRIC FRYER USER S MANUAL

Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board


USER S MANUAL HSC-24A

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

2-SLICE COOL TOUCH TOASTER

BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150


Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

INSTRUCTION FOR THE USER

Dehumidifier Users manual. For Models: DH45S DH65S

INSTALLATION & USER INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Appliances. Year Limited Warranty INCLUDED

Convection TCO650. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

RFQ # PR Replace Kitchen Equipment in the CGR

LUCCI AIRFUSION QUEST II CEILING FAN

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Big Button Plus 20200

Operating Instructions Split System Air Conditioner

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

QUICK REFERENCE. Wired remote controller BRC2E52C7 BRC3E52C7

Operating Instructions Bedienungsanleitung Mode d emploi

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

INDOOR UNIT/OUTDOOR UNIT

INSTALLATION & USER INSTRUCTIONS WALL MOUNTED LCD ELECTRIC FIRE

Name Of Occupancy Date. Yes No Describe

SYSTEM Inverter Air Conditioners

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

24 Wide Screen LED Monitor with HDMI

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Fire Damage. To Help Prevent. a Guide

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Cable Drum Machine. Operation Manual BC260 SERIES. Cleans 1 1/4" to 3" lines up to 50'

TS93 EMR T/PT/TDE. Surface applied door closer

SL280UHV SERIES GAS FURNACE WARNING

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

PORTABLE AIR CONDITIONER

WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING

Front axle components, overview

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

AutoDome Easy II. VEZ Series. Mounting Manual

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Wall hoods. Wall hoods. Built-in hoods. Orion. p. 12 Stilo. p. 13 Talia. p. 15. Apolo. p. 16 Helia. p. 17. Air 20. p. 18 Air 10. p.

INSTRUCTION MANUAL RM AM/FM Digital Alarm Clock Radio

Meaco 30L and Meaco 40L dehumidifier instruction manual

Operating instructions. SCORP 220 Plus SCORP 360. Pipe Cutter. Code Machine-no.:

the Soft Top Breville Customer Service Center Instruction Book - Livret d instructions

Transcription:

INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90

Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood has been designed and manufactured specially with a view to satisfying your expectations and it will certainly constitute a fitting element of a modern kitchen. The modern structural solutions and the newest technologies used in production of this hood guarantee its high effectiveness and good appearance. Please read these instructions carefully before installing the hood. They will make you avoid mistakes during installation and operation of the hood. We wish you a lot of satisfaction from choosing our kitchen extractor hood. INHALTSVERZEICHNIS I Characteristics 3 II Components 3 III Technical data 4 IV Operating conditions 4 V Installation 5 1. Installation of the hanger 5 2. Installation of the hood 6 3. Connecting to the power network and operation check 7 4. Setting the operation mode of the kitchen extractor hood 7 4.1. Setting the air extractor mode of operation of the hood 7 4.2. Setting the odour absorber mode of operation of the hood 7 4.3 Fan speeds 7 VI Operation and maintenance 7 1. Operational safety 8 2. Operation 8 2.1. Control panel 8 2.2. Program function 8 3. Maintenance 9 3.1. Metal grease filters 9 3.2. Carbon filter 9 3.3. Lighting 10 3.4. Cleaning 10 NOTICE 11 2

I. Characteristics Kitchen extractor hood IH 17025 Sigma Island was designed to remove kitchen fumes. It requires installation of a conduit discharging used air to the outside. The conduit (usually a pipe, with Ø150 mm) shall not be longer than 4-5 m. The hood can operate as an odor absorber after installation of an active carbon filter. In such case a conduit discharging used air to the outside is not necessary, but it is recommended to install an air exhaust guide. The kitchen hood is an electrical appliance manufactured according to class II of shock protection. It has its own lighting and an exhaust fan which can be set to one of three rotational speeds. The hood was designed for permanent installation on a vertical wall over a gas or electric cooker. II. Components The hood consists of the following elements (Fig. 1): 1. Hood body D, equipped with lights, 2. Upper chimney B, and lower chimney A, 2. Ceiling hanger equipped with the fan unit C, 3. Set of mounting plugs. 3

III. Technical data Type Characteristiscs IH 17025 E Supply voltage AC 230V 50Hz Fan motor 1 Lighting Halogen lights 4x20W Number of grease filters 2 Fan speeds 4 Width [cm] 90 Depth [cm] 60 Height [cm] 70,5 102 Outlet [ø mm] 150 or. 120 Capacity [m 3 /h] Max. 900 Power consumption [W] 280 Noise level [dba] Max. 51 Operational mode Extractor or absorber Colour INOX IV. Operating conditions 1. The kitchen hood was designed for removal of kitchen fumes to the outside. It should be connected to an appropriate ventilation duct (do not connect the hood to any chimney, smoke or flue-gas ducts which are in use). 2. The device shall be installed at the distance of at least 650 mm above the working top of an electric cooker and 700 mm - of a gas cooker. 3. Do not leave open flame under the hood. When removing pots from the burners set the flame to its minimum level. 4. Any food cooked in fat shall be constantly monitored, since overheated fat can ignite very easily. 5. The grease filter of your kitchen hood should be cleaned at least every 2 months, because a filter soaked with grease becomes easily flammable. 6. Pull the plug of the power cord from a wall socket before any cleaning, filter replacement or repair operation. 7. If any other non-electric devices are used in the same room as the hood (e.g. liquid fuel ovens, flow-through or volumetric water heaters), it is necessary to provide appropriate ventilation (air supply). Safe operation is possible when during simultaneous operation of the hood and combustion devices dependent on air supply the negative pressure of not more than 0.004 milibar is maintained at the location of these devices inside the room (this point does not apply when the hood is used as an odour absorber). 8. When connecting to 230V power supply network use an electric socket in working order 4

V. Installation To install the hood proceed as follows: 1. Install the ceiling hanger C, 2. Hang the hood body D on the hanger C 3. Connect the hood to the ventilation duct. 4. Connect the hood to the power network. 1. Installation of the ceiling plate a) Indicate the center of the cooker plate on the ceiling, b) Unscrew the ceiling installation plate from the top decorative cover (Fig. 3), place it against the position marked on the ceiling, align it properly with the cooker, mark the fixing holes, c) Drill the holes marked on the ceiling using drills of diameter appropriate to the purchased installation plugs/dowels. Put the plugs in the drilled holes and screw the installation plate to the ceiling. 5

2. Installation of the hood a). Install upper chimney part B, Fig. 1 on the motor set (Fig. 3). Use screws G as is shown on Fig 4. b). Put the lower chimney onto the upper and hold it in maximum position. c). Install part D from Fig. 1, as it is shown on Fig. 5. Please remember, about minimal distance between hood and cooking plate (see Fig. 2). Put down the lower chimney, on correct place. d). Take off the aluminum filters. Connect the wires inside the hood. Install the filters once again. e). Connect the hood in to the net. Hood is install correctly. 6

3. Connecting to the power network and operation check After connecting the device to the power supply network (in accordance with the requirements defined above) it is necessary to check the lighting of the hood and whether its motor works correctly. The wall socket shall be accessible for disconnecting the plug after the hood is installed. 4. Setting the operation mode of the kitchen extractor hood 4.1 Setting the air extractor mode of operation of the hood In the extractor mode air is discharged to the outside by a special conduit. In that setting any carbon filters shall be removed. The hood can be connected to the opening discharging air to the outside by means of a rigid or flexible conduit of 150 mm diameter, and appropriate clamps for conduits which should be purchased in a shop selling installation materials. A qualified installer should be commissioned to make the connection. 4.2 Setting the odour absorber mode of operation of the hood In this option filtered air returns to the room through cut outs on both sides of the top funnel. In this setting it is necessary to install the carbon filter; installation of the air exhaust guide is recommended. 4.3 Fan speeds. The lowest and medium speeds should be used under normal conditions and with low concentration of fumes. The top speed should be used in case of high concentration of kitchen fumes, e.g. during frying or grilling. VI. Operation and maintenance 1. Operational safety. All safety instructions included in this manual shall be observed without exception! Grease filters and active carbon filters should be cleaned and replaced according to manufacturer s instructions, or more frequently in periods of intensive use (more than 4 hours a day). If a gas cooker is used it is forbidden to leave uncovered flame. When removing pots from gas burners set the flame to its minimum level. Always make sure that flame does not extend outside the pot. Such a situation causes undesired energy losses and dangerous heat build-ups. The hood should not be used for other purposes than those for which it was designed. 7

2. Operation 2.1 Control panel. Operation of the hood can be controlled by means of a combined switch (Fig. 6) - + - hood on - - - hood off, - T switch-off timer TIMER - L lighting on / off. 2.2. Program function Timer function: Kitchen extractor hood IH 17025 Sigma Island is equipped with the option of programming automatic switch-off of the hood fan in 10- minute intervals, up to maximum delay of 90 minutes. Timer is actuated by pressing T button during operation of the hood with the required fan speed. The display will flash and a dot will appear indicating that the device is in the switch-off time programming mode. Then you can program the time of automatic switch-off of the hood motor using + button, keeping in mind that the figure shown on the display multiplied by 10-minute time interval indicates the motor switch-off delay (e.g.: 1=10 minutes, 2=20 minutes, 3=30 minutes etc.). After setting the delay it has to be confirmed by pressing T button again. The display will stop flashing and will show the previously set speed, and the pulsating dot will indicate that the time to switching off of the hood motor is being counted. TIMER function can be cancelled by pressing T button again during counting of the time. NOTE: The program always memorizes the last delay setting. TIMER function has to be actuated within 20 seconds, otherwise the hood will return automatically to normal operation. The microprocessor system may get deleted or crash during momentary voltage drops in the network, and stop responding to commands from the keyboard. In such case the hood has to be disconnected from and then connected again to the power network in order to reset the system. 8

- Signalling of the active carbon filter replacing: Displaying of the letter C 220 h. - Signalling of the aluminium filter cleaning: Displaying of the letter F l00h. Both functions mentioned above do not collide with the work of the extraction hood, the number of the speed, however, becomes (from 0 to 4) not visible till the letters C or F have been deleted. After filter replacing or cleaning delete the respective letters by pushing down the pushbutton T for about 10 seconds. - Switching on/off the pushbutton highlighting: Keep pushbutton T (timer) pushed down for approximately 2 seconds. NOTE: The switching-on of the function of the automatic switching off (timer) must be carried out within 20 seconds, since otherwise, when in the meantime no activity has been executed, the extraction hood changes into the normal work mode automatically. The electronic system is protected with a quick-acting 250 V ~ 1,25 A cut-out (glass fuse insert 5 x20). 3. Maintenance Regular maintenance and cleaning of the device will guarantee its good and fault-less operation, and extend its life. Attention should be paid to replacing grease and carbon filters according to manufacturer s instructions. 3.1 Metal grease filters 1. Cleaning. Grease filters should be cleaned every two months during normal operation of the hood, in a dishwasher or manually, using mild detergent or liquid soap. 2. Replacement: To dismantle the filter proceed as follows: a) remove the bottom cover by releasing the lock catch, b) remove the metal grease filter 3.2. Active carbon filter (KF 17141) 1. Function description. Active carbon filters only are used if the extraction hood is not connected to the ventilation tube. An active carbon filter is able to absorb odours until its saturation. It is neither washable nor suitable for the regeneration and should be replaced at least every two months, and in the case of a particularly intensive use even more often. 2. Active carbon filter replacement. a) Remove metal grease filter, b) Put a new active carbon filter on the metal grease filter, as it is shown on Fig 7. 9

3.3. Lightning. The lighting system consists of 4 halogen lamps of 20 W power each. To replace a light bulb proceed as follows: a) Using a flat tool or screwdriver push on the ring holding the halogen lamp glass (Fig. 8), catch it, and remove to the outside. b) Replace the bulb using a piece of cloth or paper for that purpose. c) Then reinstall the ring and the glass proceeding in reverse order. Note: Make sure that you do not touch the halogen bulb to be installed with your bare fingers! 3.4. Reinigung The following shall be avoided during normal cleaning of the hood: wet cloth or sponge and water jet, solvents or alcohols which might dull lacquered surfaces, caustic agents, particularly in regard to cleaning stainless steel elements, hard, rough cloth It is recommended to us moist cloth and neutral cleaning agents. 10

NOTICE... 11

12