Main features * : Internal database > 1000 tests. Suprathreshold tests. High frequency. Musical frequencies. Automatic masking.



Similar documents
GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER. Setting The Clinical Standard

GSI AUDIOSTAR PRO. Free Call: CLINICAL TWO-CHANNEL AUDIOMETER. Australian Distributer:

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

Product Line for Hearing Screening & Diagnostics

Air Conduction Audiometer Series. MA 27 with headphones and built-in carrying case. MA1, MA25 & MA27.

PURE TONE AUDIOMETRY Andrew P. McGrath, AuD

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

MA 25 Operating Manual

Operating Instructions MAICO MA 52

Using Your Fitting Software This guide provides comprehensive, task-based information about all the fitting software features.

HCS-3600MB2 Conference Main Unit

Instructions for the use of E-A-RTONE 3A. Insert Earphones. Revised 1997 per ANSI S and ISO 389-2: /99

MA33 & MA55. PC Based Audiometers. The ideal choice for health care professionals on the go. by Maico Diagnostics

Type-D EEG System for Regular EEG Clinic

MA 41 Operating Instructions

PURE TONE AUDIOMETER

PowerGem Pro Uninterruptible Power Supply

GSM GATEWAY PRI / E1 RACK 3U

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Application Note. Introduction to. Page 1 / 10

IntesisBox KNX Modbus TCP master

Audiometer Calibration System

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

testo easyheat Configuration and Analysis software Instruction manual

Instruction Manual FL

Agilent E5100A Network Analyzer

instruction guide Version 2.2 Table of contents

The Accuracy of 0 db HL as an Assumption of Normal Hearing

TI 313 (1.0 EN) d&b Remote network - Integration

PRImaGate Switch RACK 3U

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Instruction manual. testo easyheat Configuration and Analysis software

INTREPID Perimeter Intrusion Detection System

Perimeter Security System

LSM-480 USER MANUAL. A.D.J. SUPPLY EUROPE B.V. Junostraat EW Kerkrade The Netherlands

Rack mounted telephone- and leased line modem for industrial applications

Kenwood introduces. new HF/50MHz All-Mode Transceiver

Audiometer Calibration System Manual

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

GV-Data Capture V3 Series User's Manual

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

1000+ AUDIOMETER OPERATING INSTRUCTIONS

Premium Server Client Software

Regards from the Team at Rheology Solutions.

Nardalert S3 Non-Ionizing Radiation Monitor

MS9500 SERIES VOYAGER PRODUCT GUIDE. Single Line, Hand-Held, 1D, High-Density 1D, PDF-417 2D and Wireless Laser Bar Code Scanners

for CS flow / dew point sensors

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

IntesisBox KNX Modbus RTU master

IntesisBox KNX LG Air Conditioning

R&S ZNBT8 Vector Network Analyzer Specifications

Continuous, remote monitoring and logging of electromagnetic fields

HDO700 P FIBRE OPTIC TRANSMITTER

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

HEARING AID REGULATION 196/2001 [Authority Repealed]

T Substation Maintenance and Commissioning Test Equipment

Datex-Ohmeda Critical Care Monitor

User manual Rev 1.3 Contents

Phase Modular Finally the benefits of Modular ups are for all

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

General from page 5. MAGIC TH6 from page 10 Hardware Options Software Options Applications with MAGIC TH6. MAGIC VoIP Hybrid Manager from page 23

Everything you need for protection scheme testing

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Professional PC water leak correlator Perfect results thanks to fully digital technology

HEARING MEASUREMENT 8.1. INTRODUCTION (RATIONALE FOR AUDIOMETRY)

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Electronic Control Devices The European Product Catalogue 2007

Manual Pure-Tone Threshold Audiometry

GeoMax GNSS Zenith10 & Zenith20 Series

AC3200 INTELLIGENT BROADBAND AMPLIFIER

BATRON DOCUMENT NUMBER AND REVISION VL-FS-BTHQ 21605VSS-02 REV.A (BTHQ 21605VSS-FSTF-LED05W(1 DIE)) Feb/2002 BTHQ FSTF-LED WHITE 1/15

Distributed by TestEquity LLC

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Android based Alcohol detection system using Bluetooth technology

Technical Description. Multifunctional Desk-Top Call Station Digital Version 8, 16 Keys L.No ,

SBC8600B Single Board Computer

IntesisBox KNX - LON

Multi-Range Programmable DC Power Supplies 9115 Series

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

3U 4V 4A L1 L2 L3 V2 = 314 V3 = -84 N = -14 > ensuring high performance C.A 8332B C.A 8334B C.A 8335 POWER AND ENERGY QUALITY ANALYSERS

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

Telephony Systems Trainer CODITEL

R&S ZNC Vector Network Analyzer Specifications

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

SC-30 INTEGRATING SOUND LEVEL METER REAL TIME FREQUENCY ANALYZER

Unidirectional Transmitter/ Receiver Units Introduction

DSA800 Series Spectrum Analyzer

43 Full HD Direct-lit LED Commercial Display

360 Programming Guide

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

BRIDGEWAY MOBILE VOIP RADIO-INTERCOM GATEWAY

Measuring electric and magnetic fields

1.44 kw Programmable DC Power Supplies XLN Series

Voice Dialer Speech Recognition Dialing IC

Telephone- and leased line modem for industrial applications TD-36

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

DAILY BIOLOGIC CHECK OF AUDIOMETERS

Transcription:

NEW RNGE OF UDIOMETER PRODUCTS screening, basic diagnosis, clinical diagnosis SIBELSOUND 400 Main features * : dvanced digital technology based on DSP Calculation of hearing loss and diagnosis Internal database > 1000 tests Suprathreshold tests High frequency Musical frequencies utomatic masking UDIOMETER USB Connectivity with other management systems (EMR - Electronic Medical Record) Customizable *see configurations Creating the future

NEW RNGE OF UDIOMETER PRODUCTS CONFIGURTION CCORDING TO MODEL Two channels Pure tone threshold audiometry by air conduction Pure tone threshold audiometry by bone conduction Pure tone threshold audiometry by free field Pure tone suprathreshold audiometry (SISIGRM) Pure tone suprathreshold audiometry (Fowler-BLB, Tone Decay, Weber, Lüscher, etc.) Speech audiometry M O OM OM + S U P R High frequency audiometry - - - Masking with narrow band noise Masking with white noise Masking with speech noise Synchronized masking Intermediate frequencies: 125, 750, 1500 Hz Musical frequencies Selection of exploration frequencies Continuous and pulse tone Pulse/alternating tone and modulating/alternating tone Reference tone (1 db) - - - Frequency modulation and amplitude modulation - - - Calculation of hearing loss Diagnosis (COUNCIL, IMSS MEXICO, ELI, SL, KLOCKHOFF, MOH, others...) Internal database for more than 1000 tests Intercom / Monitor USB and parallel connections to external printer USB computer connection RS232 computer connection udiometry software (Demo) udiometry software (Licence) Sound suppressors for air conduction External printer User manual and quick user guide Carrying bag udiometer type according to IEC60645 4 4 4 3 2 2 STNDRD OPTIONL - NOT VILBLE

THE EXPERIENCE SUPPORT US Description The SIBELSOUND 400, is a revolutionary two-channel audiometer. The entire system is controlled by Digital Signal Processor (DSP) for reliable, quick and easy audiometric exploration of hearing thresholds and screening tests, such as suprathreshold pure tone tests. The SIBELSOUND 400 audiometer was developed by SIBEL, S..'s RDI department in collaboration with the Surgery Department (Ear, Nose and Throat and udiology) of the University of Barcelona and well-known specialists in the field, in accordance with standard criteria of both national institutions such as the UNE and international institutions such as the IEC, ISO, etc. DSP digital technology Digital Signal Processor that uses an optimised microprocessor for applications that require very high-speed numerical operations. The processor is capable of working with multiple data in parallel, while its design and specific instructions are ideal for digital processing, features that distinguish a DSP from other types of processors. Communications One of the great qualities of the SIBELSOUND 400, is a communications system with other equipment that allows it to: Print directly to a USB printer Transfer information from the unit's internal database to a PC Communicate with a PC in real time Export patient tests to other management systems (EMR) Update the unit's internal firmware Using the appropriate software, communications can be established through two different channels: USB (standard) RS232C Serial (optional) Signals The SIBELSOUND 400 features: Pure tones (continuous, pulse, alternate) Frequency modulation mplitude modulation Speech Noise Narrow Band Noise White Noise Customizable

INNOVTION ND TECHNOLOGY Reset To return to the previous menu, cancel an action, delete data entries or place the counters at zero. Save Saves a test to the database. Intercom ctivates the technician/patient intercom. Right ear attenuator ctivates or deactivates a signal, depending on the "direct/inverted" working mode. SISIGRM Generates the manual increases in the SISIGRM test. Left ear attenuator ctivates or deactivates a signal, depending on whether the working mode is direct or inverted. Right channel signal Silencer or key which, when activated, sends or blocks the signal transmitted to the patient, depending on whether the working mode is direct or inverted. Invert This inverts the direct/inverted working mode of the signal keys. Left channel signal Silencer or key which, when activated, sends or blocks the signal transmitted to the patient, depending on whether the working mode is direct or inverted. Hz. Decreases and/or increases the frequency of the pure tone signal applied to the patient. Intro Used to save a test's thresholds and to give selected information. Patient Used to enter patient reference information in a test to be printed, store in the unit's internal database or transfer to a PC's database.

DDED VLUE SIBELSOUND 400 audiometer udiometry software W50 SIBELMED W50 is sophisticate software for viewing, storage, transmission, analysis and introduction of audiometric tests in a Microsoft Windows environment with the following options: Management of various patient databases Download of audiometric test data from SIBELSOUND 400 and C50 audiometers Manual audiometric test data input performed with other audiometers SISIGRM Display of different types of audiometric tests Diagnosis: (COUNCIL, IMSS MEXICO, ELI, SL, KLOCKHOFF, MOH, others...) Choice of various types of diagnosis parameters Test graphics Comparison of tests from the same patient Customizable reports Test report printouts Option for deleting tests from the unit SPEECH-UDIOMETRY PURE TONE UDIOMETRY www.sibelmed.com

INNOVTION ND TECHNOLOGY Technical Specifications FREQUENCIES ND LEVELS STNDRD FREQUENCY 125 250 500 750 1000 1500 2,000 3000 4000 6000 8000 Hz MUSICL FREQUENCY 131 262 523 1047 2093 4186 8372 Hz ir conduction 80 100 120 120 120 120 120 120 120 110 110 db HL Bone conduction 50 60 60 70 70 70 70 70 55 db HL Free field 70 80 80 80 80 80 80 80 80 db HL MSKING NOISE Narrow bandwidth C 60 80 100 100 100 100 100 100 100 100 90 db HL Narrow bandwidth BC 50 60 60 70 70 70 70 70 db HL White C 100 db SPL Speech 100 db SPL LOGO-UDIOMETRY ir conduction 100 db SPL Free field 80 db at 1m from the patient db SPL HIGH FREQUENCY 8000 9000 10,000 11,200 12,500 14,000 16,000 18,000 20,000 Hz ir conduction 90 90 90 90 50 50 50 50 50 db HL Minimum levels ll options -10-10 -10-10 -10-10 -10-10 -10-10 -10 db HL HIGH FREQUENCY -20-20 -20-20 -20-20 -20-20 -20-20 -20 db HL Level increases STNDRD 5 5 5 5 5 5 5 5 5 5 5 db Reference tone 1 1 1 1 1 1 1 1 1 1 1 db Frequency precision ± 1% Level precision ± 2% db SPL Channels: Two Functional specifications: See tables of models and frequencies Transducers: TDH39 - HD200 - B71 (depending on the model) Screen: LCD alphanumeric backlighted 2 X 16 Protection: Time restricted high frequency signals to protect both patient and unit Self-check: utomatically checks the status of the audiometer Unit test: llows the user or technician to check the condition of certain functions or components Custom settings: Programme to personalise the audiometer according to the needs of the user Calibrations: Equipped with calibrations according to ISO and NSI Safety standards: EN 60601-1:2006+C:2010, EN 60601-1-2:2007+C:2010 udiometry standards: EN 60645-1:2001, EN60645-2:1997, EN 60645-4:1995 Calibration standards: EN ISO 389-1:2000, EN ISO 389-3:1998, EN ISO 389-4:1998, EN ISO 389-5:2006, EN ISO 389-7:2005, NSI S3.6-2004 Working temperature: 10 to 40 ºC Relative humidity: <90% (no condensation) Power supply: 100 to 240V ±10% / 50/60 Hz ±3% Power: <50 V Dimensions: 390 mm x 260 mm x 105 mm Weight: 2.4 kg without accessories Standard accessories: Depending on the model Optional accessories: Depending on the model SIBEL S.., Rosselló 500, 08026 Barcelona (SPIN) Sales: Tel.+34 93 436 00 07 e-mail: export@sibelmed.com Technical Service: Tel.+34 93 433 54 50 e-mail: sat@sibelmed.com Fax:+34 93 436 16 11 SIBEL S.. belongs to www.sibelmed.com www.sibelgroup.com 0318 ISO9001:2008 EN-ISO 13485:2012+C:2012 FG0809- Sibelsound 400 - V.1.4-03/2014 SIBEL S.. reserves the right to modify the technical characteristics without prior notice.