E1/T1 or Fractional E1/T1 Access Unit with Integrated Router



Similar documents
FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Where to buy > See the product page > Data Sheet. E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

WEB RANger-II Internet Access Router

IPmux-1E TDM Pseudowire Access Gateway

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

FCD-E1E Managed E1 and Fractional E1 Access Device

Optimux-134, Optimux-125

Optimux-134, Optimux-125

Kilomux-2100/2104. Modular integrating access multiplexer for data, voice, fax and LAN. Data Sheet. The Access Company

Optimux-34, Optimux-25

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

DXC Family. Multiservice Access Node FEATURES

DXC-8R/10A/30 Multiservice Access Nodes

Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

LA-110. Advanced Integrated Access Device FEATURES

STM-1 Synchronous Digital Multiplexer and Multiservice Access Node

Loop-IP6700 TDMoEthernet

TDMoEthernet. Description

Product Overview. Features CHAPTER

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

In addition to our VoiceDirector hardware products, the following SIP broadband devices are also compatible with VoiceDirector:

Loop-IP6700 TDMoEthernet

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Loop-IP6510 Multiple WAN Router/Bridge

Loop-IP6702 TDMoEthernet

VALIANT COMMUNICATIONS LIMITED

CTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan

! encor en etworks TM

Cisco Channelized T1/E1 and ISDN PRI Modules

Mediatrix 1204 Overview

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

F2400 FOM II Series Fiber Optic Modem Technical Manual

Loop Telecom. Total Access Solutions for Enterprise Network, Cellular & Gateway Operator.

cpci cfxo3120 FXO/FXS VoIP Gateway

Egate-100 Gigabit Ethernet over TDM Aggregation Gateway

FOM-5A, 6A. Asynchronous Fiber Optic Modem

Quidway AR 18-1X Series Router Datasheet

ORION TELECOM NETWORKS INC. T1

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

CISCO SPA3102 PHONE ADAPTER WITH ROUTER

WANic 800 & or 2 HSSI ports Up to 52 Mbps/port. WANic 850 & or 2 T3 or E3 ports Full-speed CSU/DSU. WANic 880.

Cisco SPA400 Voic System with 4-Port FXO Gateway Cisco Small Business Voice Systems

Chapter 2 - The TCP/IP and OSI Networking Models

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Overview of the Cisco 2500 Series Access Server

Adit 3000 Series Part Guide

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

300Mbps Wireless N VoIP VDSL/ADSL Modem Router

HDO700 P FIBRE OPTIC TRANSMITTER

VRGIII N Series Triple Play Gateway

Extend the Life of Your Legacy PBX while Benefiting from SIP Trunks. December 5, 2013

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

Adit 600 Product Guide

Rack mounted telephone- and leased line modem for industrial applications

Octal T1-10/100 RIOP Installation Guide

How To Extend A Cell Phone Over Wireless To A Long Distance Over A Cell Tower

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

FlexPoint T1/E1 Copper to Fiber Line Driver


IPmux-216 TDM Pseudowire Access Gateway

AP200 VoIP Gateway Series Design Features & Concept AddPac R&D Center

Application Note: Extending a TSP s Analog Capabilities Using an Access Bank I

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

Optical Product Families

Controlware Access Backup Solutions

SOLUTIONS FOR AN EVOLVING WORLD IMUX T1/E1 Multiplexer. with common logic redundancy IMUX 2000 T1/E1 1

EdgeMarc 4508T4/4508T4W Converged Networking Router

DL TC72 Communication Protocols: HDLC, SDLC, X.25, Frame Relay, ATM

T1 Networking Made Easy

Model 2120 Single Port RS-232 Terminal Server Frequently Asked Questions

Public Network. 1. Relatively long physical distance 2. Requiring a service provider (carrier) Branch Office. Home. Private Network.

SOHOware Long Reach Ethernet (LRE) Solution

MITEL 3300 CONTROLLERS

Product Specifications

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

MITEL MiVOICE BUSINESS 3300 CONTROLLERS

The BANDIT Device in the Network

AM3440-A/B/C Access Mux. Description. Features

1. Overview. 2. F-bit Utilization

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Multiband MAX. Multimedia Access Videoconferencing Backup/Overflow. Networking Solutions for High Bandwidth Network Requirements

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

User Manual. SIP Analog Telephone Adaptor SIP-GW2. Sedna Advanced Electronics Ltd.

Cisco Third-Generation 1-, 2-, and 4-Port T1/E1 Multiflex Trunk Voice/WAN Interface Cards

G-TAP A Series // Data Sheet

CTS2134 Introduction to Networking. Module 07: Wide Area Networks

The Product Description of SmartAX. MT882 ADSL2+ Router

Transcription:

Where to buy > See the product page > Data Sheet FCD-IP Integrated access device providing bundled services over E1/T1 access lines Provides bundled services (data, IP, and telephony) over E1/T1 access lines E1/T1 uplink over copper or fiber optic media Operates opposite RAD's DXC cross-connect system and Megaplex access multiplexers Supports Frame Relay, PPP, and MLPPP FCD-IP is an E1/T1 or fractional E1/T1 integrated access device (IAD), which enables service providers to bundle data, voice, and IP access services over a single E1 or T1 access line (see Figure 1). Supported WAN services are: T1 or fractional T1 CSU/DSU operating at rates of up to 1.544 Mbps E1 or fractional E1, with or without LTU, operating at rates of up to 2.048 Mbps E1 or T1 over fiber optic links Frame Relay with auto-learn of DLCI and maintenance protocol ISDN BRI ( U or S interface) for data services backup. The Access Company

FCD-IP An integrated router supports IP routing and transparent bridging. An optional internal 4-port Ethernet/Fast Ethernet switch can be installed in place of LAN ports. Internet/intranet access capabilities are enhanced through: IP Service Access authentication provided by PAP/CHAP Solid Firewall that protects an office LAN from undesired entry from the Internet NAT that allows the sharing of several legal IP addresses between the various LAN users Single IP address translation that allows a small or medium office LAN to connect to the Internet using a single dynamically or statically allocated IP address DHCP server that allows the sharing of ISP address pools between DHCP clients on the LAN. OSPF protocol based on the link state technology, distributing information about the state of links between routers. The sub-e1/t1 or quad analog voice drop-and-insert ports provide toll-quality voice transmission. Up to three sub-e1/t1 ports can be installed in FCD-IP, aggregating three fractional E1s into one full E1 stream (see Figure 2). In the ring (Figure 3) and daisy-chain and shared LAN applications (Figure 4), the first sub-e1/t1 port (sub1-e1/t1) can be used as a main link. In this case some of the E1/T1 timeslots pass through internal routers of all FCD-IP devices used in the application. The other timeslots are dropped at the user interfaces (FXS, remaining sub-e1/t1 ports etc). This enables the units to drop and insert timeslots and take routing decisions at any FCD-IP. Notes: The sub1-e1/t1 port cannot be defined as a main link if FCD-IP includes a DTE data port, two LAN ports or ISDN ports. FCD-IP connected to two LANs cannot be used in the ring applications. The fail-safe bypass of the sub1-e1/t1 link ensures the continuity of voice services in case of power supply failures. The bypass is not available for the fiber optic main links. ISDN or PSTN backup, using an external dial-up modem, ensures the continuity of data services. Figure 1. Bundled Services

Data Sheet An optional data port can be utilized either as a second serial router port or as a transparent n 64, n 56 data port for connecting legacy equipment. The unit can be easily configured through a quick setup menu using a terminal attached to the control port or by Telnet access over the LAN/WAN. FCD-IP features a variety of inband and out-of-band management options. These options include dedicated timeslot, dedicated DLCI and dial-in. The SNMP agent provides management by RADview or any other standard SNMP management station. Undesired access to FCD-IP via Telnet or SNMP can be blocked or password protected. The dual-level management authentication allows user access to router configuration parameters, while restricting user access to network configuration parameters. Software download is available via the control port using XMODEM and via LAN/WAN using TFTP. Parameter file download and upload is available via LAN or WAN using TFTP. Figure 2. Aggregating Three Fractional E1 Links into One Full E1 Link

FCD-IP Specifications E1 INTERFACE Framing G732N (no MF, CCS) G732N (no MF, CCS) with CRC-4 G732S (TS16 MF, CAS) G732S (TS16 MF CAS) with CRC-4 Bit Rate 2.048 Mbps Line Code AMI Zero Suppression HDB3 Impedance 120, balanced 75, unbalanced Signal Level Receive: 0 to -36 db with LTU 0 to -12 db without LTU Transmit: 3V ( 10%), balanced 2.37V ( 10%), unbalanced Jitter Performance As per ITU G.823 Connectors RJ-45, balanced or two BNC coaxial, unbalanced (via adapter cable) Diagnostics ITU G.703, G.704, G.706, G.732 User-activated local and remote loopbacks T1 INTERFACE Framing D4, ESF Bit Rate 1.544 Mbps Line Code AMI Zero Suppression Impedance 100 balanced Signal Level Receive: Transparent, B7ZS, B8ZS 0 to -36 db with CSU 0 to -15 db without CSU Transmit: 0, -7.5, -15, -22.5 db with CSU Soft adjustable at 0 to 655 ft, without CSU Jitter Performance As per AT&T TR-62411 Connector RJ-45 8-pin, balanced Diagnostics AT&T TR62411, ANSI T1.403 User activated local and remote loopbacks Network activated loopbacks and FDL loopbacks (RLB, LLB) ANALOG VOICE INTERFACE Number of Channels Four Modulation Method PCM (per ITU-T G.711 and AT&T PUB-43801), -Law or A-Law

Data Sheet INTERFACES E&M: 2-wire or 4-wire, supporting different types of E&M signaling: RS-464 Types I, II, III and V, and BT SSDC5, software-configured FXS: Loop start, WINK start (reverse polarity) for direct connection to a 2-wire telephone, CID (Caller ID) support FXO: Loop start, WINK start (reverse polarity) connection to a 2-wire telephone exchange subscriber line Nominal level: 0 dbm Nominal impedance: 600 Return loss: (ERL), better than 20 db Frequency response (Ref: 1020 Hz): 0.5 db, 300 to 3000 Hz 1.1 db, 250 to 3400 Hz Signal to total distortion, G.712, G.713 method 2: 0 to -30 dbm0, better than 33 db +3 to -45 dbm0, better than 22 db Idle channel noise: Better than -70 dbm0 (+20 dbrnc) Transformer isolation: 1500 VRMS DIAGNOSTICS Local digital loopback towards the analog side Remote analog loopback towards the remote side, activated from the local side 1 khz tone injection towards the analog side Connectors E&M: RJ-45, 8-pin FXS, FXO: RJ-11, 6-pin ISDN INTERFACE Interface ISDN BRI, S and U ETS 300012, I.430, NTT, 5ESS, DMS-100, NI1 Table 1. Fiber Optic Interface Characteristics Wavelength Fiber Type Transmitter Type Power Sensitivity Receiver Range Typical Max. [nm] [ m] [dbm] [dbm] [km] [miles] 850 62.5/125 multimode 1310 9/125 single mode 1550 9/125 single mode VCSEL -18-38 5 3 Laser -12-39 62 38 Laser -12-39 100 62

FCD-IP LAN INTERFACE Number of Ports 1, 2, or 4 IEEE 802.3 Type Single 10/100BaseT (RJ-45) port Dual 10BaseT (RJ-45) 4-port 10/100BaseT (RJ-45) switch DATA PORT INTERFACE Type and Connectors RS-232/V.24 or RS-530 with 25-pin D-type, female RS-422/V.36 with 37-pin D-type, female V.35 with 34-pin female X.21 with 15-pin D-type, female Note: All synchronous data ports are equipped with 25-pin D-type, female connectors. Adaptor cables for the V.35, V.36 and X.21 interfaces are supplied with the unit. FIBER OPTIC INTERFACE Types See Table 1 ITU G.921, G.955 (11/1996) WAN PROTOCOLS Type Frame Relay - RFC 1490 PPP and MLPPP ROUTING Types STATIC, RIP-I, RIP-2, RIP/SAP, OSPF ARP Table Up to 300 MAC addresses GENERAL Power AC: 100 to 240 VAC ( 10%), 50 to 60 Hz, 13 VA max DC: -24 to -48 VDC, 13W Physical Height: 4.4 cm (1.8 in) (1U) Width: 21.6 cm (8.5 in) Depth: 24.0 cm (9.4 in) Weight: 1.1 kg (2.5 lb) Environment Temperature: 0 C to 50 C (32 F to 122 F) Humidity: Up to 90%, non-condensing Figure 3. FCD-IP in an E1 Ring Topology

Data Sheet Ordering # STANDARD CONFIGURATIONS FCD-IP/DC/E1/U/S FCD-IP/E1/U FCD-IP/DC/E1/FC13L/U/E&M FCD-IP/E1/4U/FXS FCD-IP/E1/U/S SPECIAL CONFIGURATIONS FCD-IP/~/$/+/* E1/T1 or fractional E1/T1 access unit with integrated router Legend ~ DC power supply (Default=AC power supply): DC -20 to -72 VDC Note: FCD-IP with FXS, FXO and E&M voice interfaces cannot work with -24 VDC voltage within the DC power supply range. $ Primary WAN interface with optional second data port: E1/# E1 or fractional E1 (RJ-45 only) T1/# T1 or fractional T1 E1/?/!/# E1 or fractional E1 with built-in fiber optic modem T1/?/!/# T1 or fractional T1 with built-in fiber optic modem Note: The T1 line cannot be used for a ring application. Optional second WAN interface: V24T V.24/RS-232 (DTE) V35T V.35 (DTE) 530T RS-530 (DTE) V36T V.36/RS-422/RS-449 (DTE) X21T X.21 (DTE) or Serial port interface: V24C V.24/RS-232 (DCE) V35C V.35 (DCE) 530C RS-530 (DCE) V36C V.36/RS-422/RS-449 (DCE) X21C X.21 (DCE) Note: All synchronous data ports are equipped with 25-pin D-type, female connectors. Adapter cables for the V.35, V.36, and X.21 interfaces are supplied with the unit.? Fiber optic connector: ST ST connector FC FC/PC connector SC SC connector! Wavelength and type: 85 850 nm, multimode, VCSEL 13L 1310 nm, single mode laser diode 15L 1550 nm, single mode laser diode + LAN interface: U 10/100BaseT (UTP) 2U 2 10BaseT (UTP) 4U 4 10/100BaseT (UTP) built-in switch * Optional sub-e1/t1, analog voice or ISDN backup interfaces: S sub-e1/t1 port (RJ-45 only) 2S 2 sub-e1/t1 ports (RJ-45 only) 3S 3 sub-e1/t1 ports (RJ-45 only) FXS 4 FXS voice channels FXO 4 FXO voice channels E&M 4 E&M voice channels IBE ISDN S interface IBU ISDN U interface FXS/S 4 FXS voice channels and one sub-e1/t1 port FXO/S 4 FXO voice channels and one sub-e1/t1 port E&M/S 4 E&M voice channels and one sub-e1/t1 port IBE/S ISDN S interface and one sub-e1/t1 port IBU/S ISDN U interface and one sub-e1/t1 port Notes: 1. The second WAN option is not available when configuring E1/T1 with an ISDN backup. 2. The dual LAN configuration is not available when configuring E1/T1 with an ISDN backup. 3. The line cannot be fiber for options 3S, FXS/S, FXO/S, E&M/S, IBE/S, or IBU/S. 4. 3S (3 sub-e1/t1 ports) cannot be installed with an additional FXO, FXS, E&M, IBE, or IBU. Figure 4. Daisy-Chain and Shared LAN Topology

FCD-IP Data Sheet SUPPLIED ACCESSORIES Power cord DC power connection kit (when DC power supply is ordered) CBL-RJ45/D9/F/6FT Control port cable When V.35, V.36, or X.21 interfaces are ordered, adaptor cables are supplied with the unit. OPTIONAL ACCESSORIES CBL-RJ45/2BNC/E1 Interface cable for converting a balanced E1 RJ-45 connector into a pair of BNC unbalanced coaxial connectors RM-17 Hardware kit for mounting one or two FCD-IP units into a 19-inch rack Table 1. Comparison Table Features FCD-IP FCD-IPM Total user ports Up to 11 Up to 19 Interface types X.21, V.35, V.24, RS-530, E1/T1, E&M, FXS, FXO, ISDN, SHDSL, ETH E1/T1 line type SNMP management Interoperability E1 bypass ETH performance 10/100 MB/s 10/100 MB/s X.21, V.35, V.24, RS-530, E1/T1, E&M, FXS, FXO, ISDN, SHDSL, ETH 676-100-06/11 (4.2) Specifications are subject to change without prior notice. 1991 2011 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders. International 24 Raoul Wallenberg Headquarters Tel Aviv 69719, Israel Street Tel. Fax 972-3-6498250, 972-3-6458181 E-mail market@rad.com 6474436 www.rad.com Order North 900 Corporate America Drive Headquarters Mahwah, Tel. 201-5291100 NJ 07430, USA Toll Fax 201-5295777 free 1-800-4447234 E-mail market@rad.com this publication by Catalog No. 801764 The Access Company