Tray Distillation Columns. Efficiency, Flooding & Weeping



Similar documents
Resolving Process Distillation Equipment Problems

Lecture 9 Solving Material Balances Problems Involving Non-Reactive Processes

Design Guidelines for Using Distillation Simulation Software in the Field

Column Design. Gavin Duffy School of Electrical Engineering Systems DIT, Kevin Street

Trays for any Application. Sulzer Chemtech

Gas Detection for Refining. HA University

Morrison Bros. Co. General Product Specifications

Thermostatic bar showers. Troubleshooting and maintenance

Why is my air conditioner dripping on my customers?

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

How To Make A High Co 2 Gas Blend

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

Distillation Principles

Liquid Distributors. Liquid Redistribution. Liquid Distribution. INTALOX Distributors

TECHNICAL DATA. Dry 122a. November 12, 2013

ON DISTILLATION TRAY WEIR LOADINGS. Michael R. Resetarits & A. Y. Ogundeji Fractionation Research, Inc. 424 S. Squires St Stillwater, OK 74074

Dry-out Design Considerations and Practices for Cryogenic Gas Plants

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Steam System Efficiency. Bill Lumsden Leidos Engineering

Air Eliminators and Combination Air Eliminators Strainers

Optimization of Natural Gas Processing Plants Including Business Aspects

Pumping Fuel & Fuel Oil

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

Carburetion Troubleshooting Quick Reference Guide

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

pdi PLASTIC DRUM INSTITUTE Plastic Drum Paneling Issues

Installer s Guide 18-AH39D1-13

Gas Custody Transfer Calibration

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50

SAMPLE CHAPTERS UNESCO EOLSS NATURAL GAS PROCESSING. H. K. Abdel-Aal National Research Center (NRC), Cairo, Egypt

Flushing and Cleaning the A/C System

Mechanical Seal Piping Plans

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

APCO SLOW CLOSING AIR/VACUUM VALVES

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

1301 Series High-Pressure Regulators

PRACTICAL PROCESS HYDRAULICS CONSIDERATIONS

Ethanol-Water Phase Separation White Paper

CEE 370 Fall Laboratory #3 Open Channel Flow

DESIGN, TESTING, AND OPERATING EXPERIENCE OF A SALTWATER DISPOSAL SYSTEM OIL-WATER SEPARATOR

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

WAVELET WATER QUALITY MONITORING KIT

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Spill Containment Manholes

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

NFPA : Basic Requirements for Storage Tanks

STEADY-STATE AND DYNAMIC SIMULATION OF CRUDE OIL DISTILLATION USING ASPEN PLUS AND ASPEN DYNAMICS

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Natural Gas Dehydrator Optimization

C. starting positive displacement pumps with the discharge valve closed.

1805 Series Relief Valves

PBX Series Quick Fit Connector Bimetallic Steam Traps

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

FLASH TANK ECONOMIZER PRODUCT GUIDE

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.

Liquid level measurement using hydrostatic pressure and buoyancy

What to Expect From the Examination. How to Study the Plumbing Codes

SUMP PUMP. Sump Pump Backup Systems. City of Ann Arbor B A C K U P O P T I O N S. Does everyone need a backup system?

Installation Instructions

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

Blowdown vessels Meeting the requirements of HSE PM60

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Steam System Best Practices Condensate System Piping

Comparative Economic Investigation Options for Liquefied Petroleum Gas Production from Natural Gas Liquids

oil liquid water water liquid Answer, Key Homework 2 David McIntyre 1

Auto-belay Cable Replacement Process

CEILING CASSETTE FAN COIL UNIT

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

A new motivation and perspective on teaching simulation and design:

Fire Hydrant Troubleshooting

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

SL280UHV SERIES GAS FURNACE WARNING

Please keep this manual for f uture reference.

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Surface Tension. the surface tension of a liquid is the energy required to increase the surface area a given amount

METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS

Float and Thermostatic Traps Series H, C and X

Toroidal Conductivity Sensor

COMMERCIAL GAS DRYER

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Draining and filling cooling system

TABLE OF CONTENT

Fixtures - Parts - Accessories to shampoo bowls

Natural Gas Emergencies

INSTALLATION AND SERVICE MANUAL

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

Cartridge Filter Application Notes

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Kompressoren. Adsorption Dryer AD

NOTIFICATION OF PERFORMANCE TESTING FOR GASOLINE DISPENSING FACILITIES (GDFs) NESHAP 40 CFR, Part 63, Subpart CCCCCC (Sections

Evaporator Coil Installation Instructions

Flammable Liquids 29 CFR

Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized

Supplemental Questions

Transcription:

Tray Distillation Columns Efficiency, Flooding & Weeping

Tray Columns A tray consist of: Overflow or outlet weir Downcomer Tray Deck & Troubleshooting (2)

Tray Efficiency Distillation trays in a fractionator operate between 10 and 90 percent efficiency. Tray Efficiency : Compare the vapor temperature leaving a tray to the liquid temperature leaving the tray Poor Tray Efficiency is caused by: Flooding Dumping & Troubleshooting (3)

100% Efficiency & Troubleshooting (4)

Zero Percent Efficiency & Troubleshooting (5)

Average Tray Efficiency =10% & Troubleshooting (6)

Flooding due to lack of a downcomer clearance & Troubleshooting (7)

When flooding starts on a tray, all the trays above that point will also flood, but trays below that point will go dry. An early indication of flooding in a distillation column is loss of liquid level in the bottom of the column. If the downcomer clearance-which means the distance between the bottom edge of the downcomer and the tray below-is too great, the downcomer becomes unsealed. Vapor flows up the downcomer, and the trays above flood. If the downcomer clearance is too small, then liquid backs up in the downcomer, and the trays above flood. To calculate the height of liquid in the downcomer, due to liquid flowing through the downcomer clearance: H = 0.6 V 2 & Troubleshooting (8)

Loss of Downcomer Seal When the height of outlet weir is below the bottom edge of the downcomer from the tray above. This permits vapor to flow up downcomer. The upflowing vapor displaces the downflowing liquid flooding. The bottom edge of a downcomer should be about ½ inch below the top edge of the outlet weir. & Troubleshooting (9)

& Troubleshooting (10)

Vapor-Flow Pressure Drop When vapor flows through a tray deck, the vapor velocity increases as the vapor flows through the small openings provided by the valve caps, or sieve holes. The energy to increase the vapor velocity comes from the pressure of the flowing vapor. A common example of this is the pressure drop we measure across an orifice plate. If we have a pipeline velocity of 2 ftls and an orifice plate hole velocity of 40 ftls, then the energy needed to accelerate the vapor as it flows through the orifice plate comes from the pressure drop of the vapor itself. & Troubleshooting (11)

Vapor-Flow Pressure Drop & Troubleshooting (12)

Let us assume that vapor flowing through a tray deck undergoes a pressure drop of 1 psig (lb/in2 gauge). Figure 1.7 shows that the pres- sure below tray deck 2 is 10 psig and the pressure above tray deck 2 is 9 psig. How can the liquid in downcomer B flow from an area of low pressure (9 psig) to an area of high pressure (10 psig)? The answer is gravity, or liquid head pressure. The height of water needed to exert a liquid head pressure of 1 psig is equal to 28 in of water. If we were working with gasoline, which has a specific gravity of 0.70, then the height of gasoline needed to exert a liquid head pressure of 1 psig would be 28 in/0.70 = 40 in of clear liquid. & Troubleshooting (13)

Jet Flood & Troubleshooting (14)

An increase in vapor flow causes a noticeable increase in the foam height of the tray deck, which then increases the spray height. When the spray height from the tray below hits the tray above, this is called the incipient flood point, or the initiation of jet flooding. Note, though, that jet flood may be caused by excessive downcomer backup. It is simple to see, in a glass column separating colored water from clear methanol, how tray separation efficiency is reduced as soon as the spray height equals the tray spacing. And while this observation of the onset of incipient flood is straightforward in a transparent tower, how do we observe the incipient flooding point in a commercial distillation tower? & Troubleshooting (15)

How to observe incipient flood Example: Depropnaizer & Troubleshooting (16)

The tower-top temperature drops The amount of butane in the overhead propane product drops The tower bottom temperature starts to fall The reboiler duty increases, to restore the tower-bottom temperature to its set point The weight flow of vapor, and the vapor velocity through the tray, increase & Troubleshooting (17)

The spray height, or entrainment, between the trays, increases When the spray height from the lower trays, impacts the upper trays, the heavier, butane-rich liquid contaminates the lighter liquid on the upper trays, with heavier butane Further increases in the reflux rate, then act to increase, rather than decrease, the butane content of the overhead propane product & Troubleshooting (18)

Incipient Flood Concept & Troubleshooting (19)

Tower Pressure Drop and Flooding For distillation trays, the incipient flood point corresponds to the best efficiency point. ( P)(28) ( NT )( TS)( SG) = K K=0.18 to 0.25; tray efficiency close to its best efficiency point K=0.35 to 0.45; tray suffering from entrainmentincrease in reflux rate, noticeably reduces tray efficiency & Troubleshooting (20)

K>=0.5; tray is in fully developed floodopening a vent on the overhead vapor line will blow out liquid, with the vapor K=0.10 to 0.12; tray deck is suffering from low tray efficiency, due to tray deck leaking K=0; the liquid level on the tray is zero, and quite likely the trays are lying in the bottom of the column & Troubleshooting (21)

Carbon Steel Trays Carbon steel trays One of the most frequent causes of flooding is the use of carbon steel trays. Especially when the valve caps are also carbon steel, the valves have a tendency to stick in a partially closed position. This raises the pressure drop of the vapor flowing through the valves, which, in turn, pushes up the liquid level in the downcomer draining the tray. The liq- uid can then back up onto the tray deck, and promote jet flood, due to entrainment. Of course, any factor (dirt, polymers, gums, salts) that causes a reduction in the open area of the tray deck will also promote jet flooding. & Troubleshooting (22)

Weeping Through Tray Decks Uneven liquid flow across tray deck causes poor vapor-liquid mixing. Uneven vapor flow bubbling-up through the tray deck will promote vapor-liquid channeling reduce tray efficiency Solution: Outlet weir height should be high enough & Troubleshooting (23)

Tray Pressure Drop Dry-tray pressure drop: The pressure drop of the vapor as it accelerates through the sieve hole Hydraulic tray pressure drop: The weight of liquid on tray created by weir height plus crest height P hyd = AF WH + 0.4( GPM / P = K dry Dv D L V 2 g 0.67 outlet weir length) & Troubleshooting (24)

Total Tray Pressure Drop P total = P dry + P hyd If P tray << P hyd tray will start to leak or weep If P tray >> P hyd liquid on tray can blow off of the tray deck (flooding) For best efficiency: P tray = P hyd & Troubleshooting (25)

Distillation Tower Turn Down Loss of tray efficiency due to vapor velocity is commonly called turndown It is opposite to flooding If the pressure drop per tray, expressed in inches of liquid, is more than three times the weir height, then the poor fractionation is due to flooding If the pressure drop per tray is less than the weir, poor fractionation is due to weeping or dumping & Troubleshooting (26)

Reflux Rate One way to stop trays from weeping is to increase the reflux rate. The higher reflux rate increases the reboiler duty which is on automatic temperature control. This will increase the vapor flow through the trays and the dry tray pressure drop. Higher reflux however is expensive in terms of energy cost. & Troubleshooting (27)