Octopus for a sustainable future



Similar documents
Daikin Altherma hybrid heat pump. The natural combination

Split units TH with hermetic compressors

Daikin Altherma. hybrid heat pump. The natural combination

ECOCIAT. Domestic hot water heat recovery unit

Technical data. Danfoss DHP-A

The natural ombination

Natural geothermal energy.

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Daikin Altherma Hybrid Heat Pump

Hybrid system. Energy-efficient and environmentally friendly

ROTEX gas hybrid heat pump. A strong team.

york air-conditioning products Residential & VRF News 2015

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

The natural ombination

Building Energy Systems. - HVAC: Heating, Distribution -

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump

Create the right atmosphere with renewables.

D A T A S H E E T. TX3 Thermo Expansion Valves. Alco Controls TX3. Features. Introduction. Description of bulb charges

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

How to choose a heat pump and use it wisely

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

The heat is there let s use it! Using free environmental heat from the air with heat pump technology for central heating and domestic hot water

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

CUTES SOLAR POWERED AIR-CONDITIONER

D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

LG Electronics AE Company, Commercial Air Conditioning

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Heating when you need it Cooling when you don t. NIBE SPLIT Air/water heat pump

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Elements of Energy Efficiency in Data Centre Cooling Architecture

FULL DC INVERTER SYSTEMS

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hot Water. Heat pump water heaters. Residential and Commercial R410a

ultrafilter VARIOBLO Heat Regenerated Adsorption Dryer

Appendix - Controllers 179

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Study on Performance Evaluation of a Split Air Conditioning System Under the Actual Conditions

Glossary of Heating, Ventilation and Air Conditioning Terms

Gas Absorption Heat Pumps. Future proofing your heating and hot water

News in Data Center Cooling

Combi Unit Genius. The energy efficient Building Service Centre

Heat pumps: better by nature

Energy consumption and heat recovery of refrigeration system in modern Arena

UNDERSTANDING CENTRAL HEATING SYSTEMS

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Commercial Hot Water. Make a difference...

Creating Efficient HVAC Systems

ARP Food Industry, Portugal

Hiwall Hiross for Telecom. High Performance Air Conditioning

Test Report issued under the responsibility of:

Room Air Conditioner SVC MANUAL(Exploded View)

Wood market in Poland: structure of use, industrial and energy purposes

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

Energy savings in commercial refrigeration. Low pressure control

Failure code manual. content

AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Rainwater Harvesting

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8

Information Guide Domestic Air Source Heat Pumps

CRAC Precision climate control units for data centres

ALL IN ONE. Heat Pump Water Heater

Energy saving at home

DIABLO VALLEY COLLEGE CATALOG

Hybrid heat pumps. saving energy and reducing carbon emissions

HEAT PUMP FOR DISTRICT COOLING AND HEATING AT OSLO AIRPORT, GARDERMOEN

HP switch LP switch Discharge thermo Comp. Surface thermo

Network Condensing Units with Digital Modulation for Multi-Evaporator Refrigeration Systems. A Unique Concept for Refrigeration Applications

How To Use A Water Source Heat Pump

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

Vitocaldens 222-F Compact Gas-Hybrid appliance

Renewable Heat Pumps. A guide for the technically minded

CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/"SUNSTORE 4" Dipl.-Ing. Alfred Hammerschmid

Case study on residential building renovation and its impact on the energy use and thermal comfort

October 8, WHP Waste Heat-to-Power Fuel and Emission Free Power

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Conlift1, Conlift2, Conlift2 ph+

AIRAH Presentation April 30 th 2014

Top Technology for Industry, Agriculture, Business and Communities

Crowne Plaza Copenhagen Towers The world s greenest hotel

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

AdSORPTION CHILLER NAK

Dehumidifier D 850E. - Instruction manual version 02

Cooling kw Heating kw

1 Overview of applications and system configurations

Air conditioners Heating & Cooling

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

Transcription:

AN ENVIRONMENTALLY FRIENDLY HEAT PUMP - TODAY AND TOMORROW - Octopus has developed and produced heat pumps since 1981 and has, through many years development, taken forward the best possible solution for the environment and the customer. The latest product IS (Ice-Stick) has been developed and been renewed since 1991 and exists today in Sweden, Norway, Denmark, Finland, Estonia, Lithuania, Poland, Germany, Holland, Italy, Romania and Ireland. The customer is our focus therefore our principles are simplicity, environment and cost effectiveness. This governs all activity in Octopus and we focus on production, installation and service. Octopus for a sustainable future

THE ICE-STICK HEATS EFFICIENTLY AND ENVIRONMENTALLY FRIENDLY Our heat pump, the Ice-Stick, is a complete solution, very simple to install and start-up in a very short time. With the Ice-Stick one neither has to dig or drill the land. The energy for heating comes when the aluminium profiles condense the steam in the air to water and later pass on to become frost. With this heat pump the heating of your house, warehouse, weekend cottage etc. will be a lot more cost-effective than, for example oil or direct electrical. With a heat exchanger the heat is transferred to the water carrying system in the building. The Ice-Stick can very well be docked to your current water carrying systems, i.e. oil, pellets, electrical, gas or district heating. WHY AN ICE-STICK? The Ice-Stick saves energy in an environmentally friendly way. Once the Ice-Stick is installed, set the temperature you desire to have in the house, the rest is done by the Ice-Stick year after year. That is how simple an Ice-Stick is. With the Ice-Stick you will not destroy the whole of your garden or risking contaminating our already hard strained ground waters. The Ice-Stick uses only nature s forces when defrosting itself. The safe operation depends on the simple design. The Ice-Stick only depends on one moving part - the compressor. SIMPLE CONTROL THAT GIVES AN EVEN INDOOR TEMPERATURE The Ice-Stick knows of the indoor temperature and then governs both the compressor and boost heat. It also knows the heat pump water temperature and the pressure in the refrigerant circuit and checks that a machine kind operation is maintained. The need for heat in a house depends on many different factors. A big part of the year it is enough with energy from sun, people and household devices. During autumn, winter and spring, however the house will need to be heated some more. How much more varies depending on the house s energy density, ventilation, household heat, outdoor temperature, rains, distortion and sun. OctoEL (the Ice-Sticks control system) deals with this. It will only produce the amount of heat the house needs in order to hold an even indoor temperature. With the OctoEL it never produces more heat than needed, a lowest possible condensing and thereby also highest possible saving. A brilliant and simple design

HOUSE IN TYRINGE, SCANIA, SWEDEN Construction year 2003 Heated area 265 m 2 Heat pump model Heating system Temperature needed House electricity incl heating Boost IS 48X H 2 O floor heating 22 o C 9.600 kwh/år 3 m 3 wood/år Octopus Ispinne 48X with water carried floor heating is used for heating The Ice-Stick uses an electric boost and wood as extra boost INDUSTRIAL BUILDING IN ESLÖV, SCANIA, SWEDEN Construction year 1999 Heated area 840 m 2 Heat pump model Heating system Temperature needed Electricity 2 st IS 42X H 2 O floor heating 21 o C 22.000 kwh/år The building is used as an office, warehouse and workshop

THE PRINCIPLE OF A HEAT PUMP 1. The heat occupying part - low pressures This part of a heat pump is called evaporator. Through the evaporator the refrigerant runs with a low temperature and boiling point. The evaporator is heated by nature and this causes the refrigerant to evaporate. 2. Pressure increasing part - high pressures This part is the compressor. The warmed refrigerant comp rhyme avalanches and the pressure increase so that both the temperature and its condensing point ascends strongly. 3. Heat giving part - high pressures This part of the heat pump transfers the heat to the house and is called a heat exchanger. The refrigerant passes through the heat exchanger with a high-temperature and condensing point. In the heat exchanger the refrigerant is cooled down by the house s heating (e.g. radiators, floor heating), which leads to that the refrigerant condenses. 4. Pressure lowering part - low pressures This part consists of an expansion valve which expands the cooled refrigerant. This lowers the pressure which results in a substantial lowering of temperature and boiling point of the refrigerant. 1 0 to -30 C 4 2 +20 to +50 C 3

INSTALLATION ALTERNATIVES We have chosen to do the Ice-Stick in two different designs. One unit called X and the other called Xp. The different alternatives can simply be docked to the existing water carried systems e.g. oil, pellets, electrical, gas or district heating. Xp means that the heat pump module stands detached from the Ice-Stick and thereby can be placed where it is most appropriate. In the boiler-room or next to the house body. With an Xp the area between the Ice-Stick and heat pump module will function as land heat. X means that the heat pump module is placed in the Ice-Stick thereby it is two isolated water tubes and two electricty cables that have to be drawn between the house and the Ice-Stick. The control OctoEL is placed indoors.

TECHNICAL DATES Models Octopus TM IS Unit IS48X/XP IS61X/XP IS81X/XP Al-Profiles pcs 12 12 2 x 12 Electrical 400V, N3-phase 400V, N3-phase 400V, N3-phase Fuse A 10 10 16 Compressor, type Scroll Scroll Scroll Compressor, max input kw 3,0 3,7 5,0 Compressor, volume m 3 /h 11,41 14,4 19,2 Max HP water carried o C 55 55 55 Refrigerant Gasol/R290 kg ~1 ~1 ~2 Closing pressure min/max bar 1,5/23 1,5/23 1,5/23 Closing temperature evaporating/condensing o C -33/+64-33/+64-33/+64 Dimension evaporator (WxDxH) mm 810x980x2220 810x980x2220 2 x 810x980x2220 Dimension HP module (WxDxH) mm 515x555x630 515x555x630 515x555x630 Weight evaporator kg 97 97 2 x 97 Weight Heat pump module kg 87 92 102 Control unit OctoEL 10 OctoEL 10 OctoEL 16 OUR MODELS IS 48 For the smaller house with a normal energy consumption. IS 61 Combine this model with 30 metres land loop and get more energy the coldest days. IS 81 For big houses and industrial premises. This model comes with two Ice-Sticks. DIMENSION Choose one of the lying piles and then choose the heat pump model. Effect needs (kw) Total electricity (kwh) Oil (m 3 ) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 0 10 000 20 000 30 000 40 000 50 000 0 1 2 3 4 5 6 The model is recommended up to the marking IS48 IS61 IS81

Octopus Energi AB Box 161 SE-243 23 HÖÖR www.octopus.tm