Ces deux analyseurs permettent le contrôle de la qualité de l eau et des effluents.



Similar documents
Detection of (unusual) changes in wastewater composition using UV/VIS spectroscopy

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry

Designed for multi-injector endurance testing, the

INTERNATIONAL OLIVE COUNCIL

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

OEM Optical Competences. Solutions for Optical OEM Applications in Liquid Analysis.

NITRIC OXIDE and NITROGEN DIOXIDE 6014

2 Spectrophotometry and the Analysis of Riboflavin

Phosphorus, Reactive (Orthophosphate)

73 Series Spectrophotometers

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

The First Step in Effluent Treatment

Enhanced Organic Precursor Removals Using Aged Filter Media Page 1. Enhanced Organic Precursor Removals Using Aged Filter Media

Sewerage Management System for Reduction of River Pollution

Hellma. Where precision becomes an art. Calibration standards for spectrophotometers by Hellma

How To Use A Ds340 (Dsp)

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

TurbiDirect TurbiCheck TurbiCheck WL

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Application Note: Absorbance

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Overview. What is EMR? Electromagnetic Radiation (EMR) LA502 Special Studies Remote Sensing

Toxicity. Toxicity monitoring technologies for on line, on location and the laboratory

UVC LEDs for. Environmental Monitoring

Lab #11: Determination of a Chemical Equilibrium Constant

2.02 DETERMINATION OF THE FORMULA OF A COMPLEX BY SPECTROPHOTOMETRY

Nederland België / Belgique

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

DUST EMISSION MONITORING SYSTEM

Measuring Protein Concentration through Absorption Spectrophotometry

3 - Atomic Absorption Spectroscopy

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information

Brewery Wastewater: 2010 Water and Wastewater Conference Page 1

Guidelines for Online continuous monitoring system for Effluents

OT 40L / 90L. Laboratory Steam Sterilizers

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

MCAL Spectrophotometry. Spectrophotometry

ZETA POTENTIAL ANALYSIS OF NANOPARTICLES

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

digital quality control fail pass at your fingertips Smart Metrology Solutions.

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

Using the Spectrophotometer

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

Color, True and Apparent

QuickCODultra. Online COD for every kind of water. Especially for the rough stuff. Fast. Precise. Reliable. COD-ANALYSis

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

ENCM Environmental Impact Assessment and Environmental Monitoring. Determination of nitrate and phosphate levels in well water/surface water

1. Inspection and monitoring... 3

Un-cooled Multimode Pump Laser Module for Telecom Applications

Radiant Dyes Laser Accessories GmbH

Color, True and Apparent

Spectrophotometer Water Quality Analysers

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

Method 202 Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources. By: Paul Ottenstein

VWR SPECTROPHOTOMETERS

Calculating Nucleic Acid or Protein Concentration Using the GloMax Multi+ Microplate Instrument

UV-NIR LASER BEAM PROFILER

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Colorimetry Extinction coefficient (ε) Lambda max (λ max ) Qualitative vs. quantitative analysis

UV-Visible Spectroscopy

Spectrométrie d absorption moléculaire UV-visible

Application Note (A5)

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

Symmetry in Diagnostics HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. TOSOH BIOSCIENCE

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Agilent Cary 60 UV-Vis

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Air-Cooled, Direct-Diode Laser System. IDL Series

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

instruments Analytical Instruments for Science

NANYANG TECHNOLOGICAL UNIVERSITY. School of Civil and Environmental Engineering. CV2701: Laboratory 2A. Laboratory Manual. For

Spectrophotometer - Milton Roy Spectronic 21D or equivalent.

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

How to Measure Total Iron

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Upon completion of this lab, the student will be able to:

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

Electromagnetic Radiation (EMR) and Remote Sensing

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Vandal-proof keypad series

Section D..General Auto Electrical Corporation

GC-xt. The most flexible GC /GC-MS liquid sample injector

Fiber Optic Distributed Temperature Sensor (B-DTS)

Trace Gas Exchange Measurements with Standard Infrared Analyzers

SODIUM CARBOXYMETHYL CELLULOSE

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.


Transcription:

OptiLIS 201 & 301 Online multi-parameter water analyzers These two standalone analyzers enable you to control continuously both fresh water and effluents quality Ces deux analyseurs permettent le contrôle EFS 8010 de la qualité de l eau et des effluents.

Advantages No re-agent or prior filtration Self-cleaning measurement cell Ultra-low running costs 100% autonomy Flash lamp (product life >5 years) Integrated sampling system Multi-channel option (1) (1) The MULTI-CHANNEL option means that you will be able to analyze effluent from 4 different sampling locations with one single device. (2) The DILUTION SYSTEM will enable you to increase the measurement range ot the OptiLIS thus guaranteeing that the parameters will be accurately measured even with highly polluted water. Dilution option (2) PARAMETERS MEASURED COD BOD TOC SS TURBIDITY (*) NITRATES (*) COLOURS (*) DISSOLVED OYGEN TEMPERATURE CONDUCTIVITY PH REDO (*) 301 only

MEASUREMENT PRINCIPLE The OptiLIS water analyzers obtain their measurements by means of absorption spectrophotometry both visible and in UV. Organic matter has the property of absorbing light in the UV (the absorption spectrum), in the same manner as certain mineral substances such as ion nitrate. Other particles, such as suspended solids, also absorb visible light. A beam of light containing wavelengths going from the ultra-violet to the visible crosses a transparent cell containing the sample and undergoes a quantifiable attenuation. A mathematical calculation (based on Beer Lambert s law) enables the concentrations of the different parameters required for the sample to be calculated based on the absorption measured with the different wavelengths. CAS254 : absorption coefficient at 254nm CAS550 : absorption coefficient at 550nm

The models OptiLIS 201 This is the basic version of the UVvisible analyzers. OptiLIS 301 This is the top-of-the-range version of the UV-visible analyzers. It uses the «bi-lambda» measurement method. The device measures absorption at 2 distinct wavelengths - 254nm (UV) and 550nm (visible). The term frequently used for the absorption of a measured sample at 254nm is SAC254 (Spectral Absorption Coefficient at 254nm). These two wavelengths enable the OptiLIS 201 to determine the concentrations of COD, BOD, COT and SS in the effluent. The calibration is performed automatically by the device which determines the regression line between the SAC values and the values measured in a laboratory of the different samples This analyzer works on the principle of spectral recognition. The OptiLIS 301not only acquires the SAC254 and SAC550 but also provides the complete absorption spectrum of the sample between 190nm and 720nm. The information contained in the spectrum enables the device to determine more parameters than the OptiLIS 201 (nitrates, colours, turbidity) as well as providing more precise measurements for effluents whose pollution matrix is complex and variable over time EAMPLE OF THE ANALYSIS PROCESS Example of the analysis process with an OptiLIs 301 complete with a Multi-Channel system.

MEASUREMENT RANGES The dilution unit increases the range of each parameter by a factor of 30. 201 (*) without dilution unit 301 (*) with dilution unit COD 0-1000 mg/l 0-12000 mg / l TOC 0-400 mgc/l 0-4800 mgc / l BOD 0-500 mgo2/l 0-6000 mgo2 / l SS 0-1000 mg/l 0-30000 mg / l TURBIDITY x 0-30000 FTU NITRATE x 0-2100 mgno3 / l COLOUR 436 x 6000 UA / m COLOUR 525 x 6000 UA / m COULOUR 620 x 6000 UA / m DISSOLVED OYGEN 0 20 mg/l 0-20 mg/l TEMPERATURE 0 55 C 0-55 C CONDUCTIVITY 10 12000 μs/cm 10-12000 μs/cm PH 2 12 u. ph 2-12 u. ph REDO -800 - +800 mv -800 - +800 mv TECHNICAL SPECIFICATIONS 201/301 Inputs 8 x 4-20mA current inputs 4 dry contact inputs Outputs 4 current ouputs (4-20 ma) 4 relay outputs Interface Keypad and screen Data recovery USB Port Remote communication RS 232-422-485 (Modbus) Sampling Tube diameter 100mm, flow rate 130 l/ h Dimensions 650 x 600 x 500 mm Weight 60 kg Ambiant operating temperature 5-45 C Power supply 230 V - 50 Hz Humidity 95% non condensed

SITE ADDRESS Parc d activité du Baconnet 192, Allée des Chênes MONTAGNY (69700) FRANCE ACCESS MAP SUBSIDIARY IN CHINA to handle technical support (installation, training, maintenance and calibration) PHONE & E-MAIL Tel. : +33 (0)4 72 49 27 72 Fax : +33 (0)4 72 49 27 77 e-mail: sales_env@efs.fr Brochure OPTILIS V2.0 05-07-2012