Best Practices for Data Center Infrastructure Design



Similar documents
De-Mystifying Cabling Specifications

SIEMON PLUG AND PLAY FIBRE OPTIC SOLUTION

Fabrics SDN and Big Data. What this means to your white space

The Need for Low-Loss Multifiber Connectivity

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

10GBASE T for Broad 10_Gigabit Adoption in the Data Center

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Zone Distribution in the Data Center

SIEMON Data Center Solutions.

Obsolete Fiber Technology? Not in my Data Center!

Data Center Network Infrastructure The Smart Choice For Your Data Center

Network Topologies and Distances

ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

What is a Datacenter?

CISCO 10GBASE X2 MODULES

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

Corning Cable Systems Optical Cabling Solutions for Brocade

IP TELEPHONY A REVOLUTION FOR STRUCTURED CABLING SYSTEMS

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers

Broadband Video over Twisted Pair Cabling. By Paul Kish Director, IBDN Systems & Standards NORDX/CDT

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

Cabinet V800 V800 CABINETS

How To Make A Data Center More Efficient

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

ADC-APC Integrated Cisco Data Center Solutions

Considerations for choosing top-of-rack in today's fat-tree switch fabric configurations

Network Design. Yiannos Mylonas

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

InstaPATCH Cu Cabling Solutions for Data Centers

Telecommunications Infrastructure Standard for Data Centers Tutorial

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Cisco IT Data Center and Operations Control Center Tour

Data Center Architecture with Panduit, Intel, and Cisco

with Component Rating A Simple Perspective

Introduction of China Telecom Data Center. Your Connection to Asia Starts Here

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

TIA-942 Data Centre Standards Overview WHITE PAPER

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

Server Technology Inc.

Navigating the Pros and Cons of Structured Cabling vs. Top of Rack in the Data Center

Innovative Connectivity Solution for Maximum Performance and Security

Data Center Design Considerations

10GBASE-T for Broad 10 Gigabit Adoption in the Data Center

Trends and Standards in LAN Cabling Systems Intelligent Buildings

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

Your Network. Our Connection. 10 Gigabit Ethernet

Advantages of 4 th Generation CAT 6A UTP Cables. Antonio Cartagena Business Development - Caribbean Leviton Network Solutions

ADC KRONE s Data Centre Optical Distribution Frame: The Data Centre s Main Cross-Connect WHITE PAPER

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope

CISCO 10GBASE X2 MODULES

IT Cabling Solutions

Optimizing Infrastructure Support For Storage Area Networks

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Data Centre Link Survey

Enhanced Category 5 Cabling System Engineering for Performance

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram

Structured and Point to Point Network Cabling for Industrial Automation

How To Plan A Data Center Network

10GBASE-T SFP+ Transceiver Module: Get the most out of your Cat 6a Cabling

Whitepaper. 10 Things to Know Before Deploying 10 Gigabit Ethernet

Ethernet/IEEE evolution

Copper Cabling Infrastructure Offering

Implementing Fast Ethernet

10G and Beyond in the Data Center with OM3 Fiber

Panduit 28 AWG Patch Cords Installation Guideline

Arista and Leviton Technology in the Data Center

Fibre Channel Fiber Cabling

The Three Principles of Data Center Infrastructure Design WHITE PAPER

SummitStack in the Data Center

10 Gigabit Ethernet over copper: Unshielded, unprotected?

Data Communications Competence Center

40GBASE-T Advantages and Use Cases

Arista 40G Cabling and Transceivers: Q&A

Data Center Market Trends

Alternating Phase Power Distribution at the Data Center Rack PDU

White Paper. Optimizing the SAN Fiber Optic Physical Layer in Your Data Center

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Specifying an IT Cabling System

GLOBAL DATA CENTER INVESTMENT 2013

Transcription:

Best Practices for Data Center Infrastructure Design Cabling Distances and Space Planning When designing and laying out a data center, understanding best practices as well the pros and cons for each type of data center is critical. The TIA 942 data center guidelines are very specific that horizontal and vertical cabling should be run accommodating growth, so that these areas do not have to be revisited. It is also specific about equipment not being directly connected unless it is specifically required by the manufacturer. This is inline with other standards documents such as ANSI/TIA/EIA 568-B that design for opens systems architecture. So the question is raised: what is the best way to do this for a 10Gb/s environment?

There are considerations outside of the cable plant and number of connectors alone: usability, scalability, costs and the ability to perform Moves, Adds and Changes (MAC s). Additionally, some limitations exist based on the category of the cabling system. Copper and fiber distances may vary with the type of cabling system selected. We will discuss some of those parameters and their potential impact on data center designs. All copper channels are based on a worst case, 100 meter, 4 connector model. ISO/IEC 24764 (draft), TIA- 942, ISO/IEC 11801 Ed2.0 and recommendations from electronics manufacturers suggest that the fixed horizontal portion of the channel be a minimum of 15m (50 ft.). While some shorter lengths may be supported in other portions of the channels, there is a requirement in zone distribution and consolidation points for this minimum distance. When moving to 10Gb/s electronics, the 15m minimum will likely exist for all horizontal cables due to recommendations from electronics manufacturers and the fact that all models within IEEE are based on a minimum 15m distance. The 15m length is also dictated by signal strength issues, as your signal is strongest in those first 15m which can create issues with two connectors in close proximity. By providing at least 15m to the first connection point in the channel, you are allowing the attenuation to reduce the signal strength at the receiver or between components. In order to achieve the 15m distance, two options exist: either provide space in the pathway to take up the distance or create service loops under the floor. Service loops should not be a loop, but rather a loosely configured figure 8 for UTP systems, however this configuration is not a requirement for F/FUTP or F/STP systems. Bear in mind that the additional cable will consume more pathway space. Copper distances for category 6A twisted pair cabling are limited to 100m for all channels with the exception of 10GBASE-T running on category 6/class E cabling. The distance for these channels will be limited to less than 37m depending upon the scope of potential mitigation practices to control alien crosstalk. It should be noted that the purpose of TSB 155 is to provide parameters for the qualification of existing Cat 6/Class E applications for use of 10GbaseT, TSB 155 should not be used for designing new installations. Fiber channel lengths vary based on the grade and type of fiber and type of interface. Understanding these limitations will assist in the design and layout of the data center space. If you are utilizing 10GBASE-CX4 or Infiniband, you are distance limited to a maximum of 15m. The following chart summarizes the distances for all 10G applications and their associated cabling systems. 2

Application Media Classification Max. Distance Wavelength 10GBASE-T Twisted Pair Copper Category 6/Class E UTP up to 55m* 10GBASE-T Twisted Pair Copper Category 6A/Class E A UTP 100m 10GBASE-T Twisted Pair Copper Category 6A/Class E A F/UTP 100m 10GBASE-T Twisted Pair Copper Class F/Class F A 100m 10GBASE-CX4 Manufactured N/A 10-15m 10GBASE-SX 62.5 MMF 160/500 28m 850nm 10GBASE-SX 62.5 MMF 200/500 28m 850nm 10GBASE-SX 50 MMF 500/500 86m 850nm 10GBASE-SX 50 MMF 2000/500 300m 850nm 10GBASE-LX SMF 10km 1310nm 10GBASE-EX SMF 40km 1550nm 10GBASE-LRM All MMF 220m 1300nm 10GBASE-LX4 All MMF 300m 1310nm 10GBASE-LX4 SMF 10km 1310nm * As defined in 802.3an THE LAYOUT...WHERE AND HOW TO CONNECT When designing a cabling infrastructure, to often cost is the deciding characteristic of the channel selected. However, once all elements are considered, a design with higher initial cost may have a lower overall cost of ownership to a company that has a lot of MAC activity. The most important concern is that designers are familiar with all aspects of the different configurations available to make the best selection possible. A listing of cost, flexibility and performance is listed below. Model Cost Flexibility Performance 2-Connector Lowest Lowest Highest 3-Connector with CP Medium Medium Medium 3-Connector with CC Medium Medium Medium 4-Connector Highest Highest Lowest 3

SPACE PNING OPTIONS The MDA (Main Distribution Area) is considered the core of the data center, connectivity will be needed to support the (Horizontal Distribution Area). Following TIA-942 recommendations and utilizing s (Equipment Distribution Areas) and ZDA s(zone Distribution Areas) we would like to present four design options for consideration. OPTION ONE Option One is to run all fibers and copper from the core horizontal distribution areas and equipment distribution areas to a central patching area. This provides one central area for patching all channels. There are several benefits to this design. First, all cabinets can remain locked. As patching is done in a central area there is no need to enter a cabinet at any time unless there is an actual hardware change. For industries that are governed by compliance and security related issues, this may provide a greater benefit by reducing physical access to connections. Intelligent patching can be added to the patching field to increase security by automatically monitoring and tracking moves, adds and changes in that environment. MDA Core & SAN Option 1 Provides Any to All connectivity. Patch cord changes in the patching area can connect any device to any device. Note: Black lines are Fiber, Blue lines are Copper Fiber Patching Area Copper Patching Area Copper Patching Area Another advantage is that all ports purchased for active gear can be utilized. With the ability to use Vs, networks can be segmented as needed. In other scenarios, entire switch blades are likely dedicated to a cabinet of servers. However, if there are insufficient server NICs to utilize all ports, then the idle ports become costly inefficient. For instance, if a 48 port blade was dedicated to a cabinet at location XY12, but there was only 6 servers with two connections each, then 36 ports were paid for and maintenance is being paid on those ports to remain idle. By utilizing a central patching field, the additional 36 ports can be used as needed elsewhere in the network thereby lowering equipment and maintenance costs which are far more expensive than the cable channels. 4

OPTION TWO Option Two is to place patch panels in server cabinets that correspond directly to their counterparts in the switch cabinets. In this scenario, switch blades/ports will be dedicated to server cabinets. This may be easier from a networking perspective, but may not provide the best usage of all ports in the active electronics. Extra ports can be used as spares or simply for future growth. However, if an enterprise is planning to implement blade technology where server density may decrease per cabinet, this may not be a cost effective option. For the switch cabinets, the type of copper cabling chosen will be a significant factor due to the increased UTP cable diameters required to support 10GBASE-T. In reality, cabinets and cabling (both copper and fiber) are changed far less frequently than the active electronics. But with the new category 6A UTP cable s maximum diameter of 9.1mm (0.354 in.), pathways within the cabinets may not provide enough room to route cable and still provide the structural stability necessary. It is always recommended that percent fill calculations be addressed with the cabinet manufacturer. Moving the patch panels to adjacent locations or implementing a lower switch density may be required. While moving switches into open racks with adjacent patch panels provides a solution, this is only recommended if proper access security processes exist and some form of intelligent patching or other monitoring system is used so that network administrators can be notified immediately of any attempt to access switch ports. MDA Core & SAN Option 2 One to One patching for each port. Least flexibility Note: Black lines are Fiber, Blue lines are Copper 5

OPTION THREE Option Three consists of providing consolidation points for connections. These can be either connecting blocks or patch panels. This allows for a zoned cabling approach, but may lead to higher moves, adds and changes costs. It is also difficult to design within the parameters of a 4 connector channel when using Zone distribution. The other disadvantage to the consolidation point model is that the changes take more time than swapping a patch cord if the pair count changes. Depending on the location of the consolidation point, there may be additional risks from loss of static pressure under the floor when removing floor tiles ending up with more than 4 connectors in a channel, or harming existing channels during changes. MDA Core & SAN Option 3 CP CP CP Consolidation Points (must be 15m min. from horizontal patch panels). Can be patched from any CP to any server cabinet. Note: Black lines are Fiber, Blue lines are Copper 6

OPTION FOUR A final option is to have all server cabinets and switch cabinets in a row, terminating to a single patching field for the row, rather than to a central location. Core connections from the MDA are brought into this patching field. This option can work well in ISP or other environments where cross department/customer functionality is not desirable or tolerated. This option provides a bit of best of both worlds in that there will be some spare ports, but also the floor tiles will not have to be lifted to perform MAC work. While this is very similar to the first option, the segmentation can make it easier for network administrators and physical plant technicians to coordinate efforts. Additionally this style of design provides for flexibility in the ever changing environment of shrinking and expanding storage/networking requirements over time. MDA Core & SAN Copper /Fiber Patching Area For Row Option 4 CONCLUSION Whichever cabling choice or space option is made, the key step is planning. Siemon has resources to assist in the layout and planning or just as a second pair of eyes for any project. For more information, and additional resources got to www.siemon.com. All Patching done within respective rows. Note: Black lines are Fiber, Blue lines are Copper ABOUT THE AUTHOR Carrie Higbie has been involved in the computing and networking for 25+ years in executive and consultant roles. She is Siemon s Global Network Applications Manager supporting end-users and active electronics manufacturers. She publishes columns and speaks at industry events globally. Carrie is an expert on TechTarget s SearchNetworking, SearchVoIP, and SearchDataCenters and authors columns for these and SearchCIO and SearchMobile forums and is on the board of advisors. She is on the Board of Directors and former President of the BladeSystems Alliance. She participates in IEEE, the Ethernet Alliance and IDC Enterprise Expert Panels. She has one telecommunications patent and one pending. 7

WORLD WIDE LOCATIONS The Americas Siemon North America 101 Siemon Company Drive Watertown, CT 06795-0400 USA Tel: (1) 866 474 1197 Customer Service Direct: Tel: (1) 866 548 5814 (US) Tel: (1) 888 425 6165 (Canada) Fax: (1) 860 945 4225 info@siemon.com Siemon CASA Central & South America Calle.77 No.11-19, Oficina 601 Edificio Torre 77 Bogota, Colombia Phone: + 011-571-317-2121 Fax: +011-571-317-1163 info_andino@siemon.com Siemon Brasil Av. Adolfo Pinheiro, 1001 -cj. 145 04733-100 São Paulo/SP Brazil Tel: (55) 11 5523 8122 Fax: (55) 11 5521 3943 info_brasil@siemon.com Siemon Mexico Blvd. Manuel Avila Camacho No. 2900-502 Fracc. Los Pirules, Tlalnepantla Edo.de Mexico, C.P. 54040 Mexico Tel: (52) 55 5370 6100 Fax: (52) 55 5370 6300 info_mexico@siemon.com Siemon Venezuela Calle Veracruz, Torre Orinoco Piso 2, Oficina 2-C Las Mercedes Caracas, Venezuela Tel: (58) 212 992 5884 Fax: (58) 212 993 9138 info_venezuela@siemon.com Siemon Peru Calle Martir Oloaya 169 of 701 Lima, Distrito Miraflores Peru Tel: (511) 446 5188 Fax: (511) 446 5188 info_peru@siemon.com Europe, Middle East, and Africa Siemon UK 36-48 Windsor Street Chertsey, Surrey KT16 8AS Tel: (44) (0) 1932 571771 Fax: (44) (0) 1932 575070 info_uk@siemon.com Siemon Germany Mainzer Landstrasse 16 60325 Frankfurt Germany Tel: (49) (0) 69 97168 184 Fax: (49) (0) 69 97168 304 info_deutsch@siemon.com Siemon France Paris Axe France ZAC Paris Rive Gauche 118-122 Avenue de France 75013 Paris, France Tel: (33) 1 46 46 11 85 Fax: (33) 1 46 46 10 00 info_france@siemon.com Asia Pacific Siemon Australia (Sydney) Unit 3A, 10 Rodborough Road PO Box 6063 Frenchs Forest NSW 2086 Sydney, Australia Tel: (02) 8977 7500 Fax: (02) 8977 7501 info_asiapacific@siemon.com Siemon Australia (Brisbane) Siemon - Australia (Brisbane) Unit 9, 128 Brookes Street Brookes Terraces (Cnr Ann & Brookes Streets) Fortitude Valley QLD 4006 Brisbane, Australia Tel: (61) 07 3854 1200 Fax: (61) 07 3854 1077 info_asiapacific@siemon.com Siemon Southeast Asia 46 East Coast Road #07-01/02 East Gate Singapore 428766 Tel: (65) 6345 9119 Fax: (65) 6345 1120 info_singapore@siemon.com Siemon Italy Via Senigallia 18/2 20161 Milano Italy Tel: (39) 02 64 672 209 Fax: (39) 02 64 672 400 info_italia@siemon.com Siemon Australia (Melbourne) Siemon - Australia (Melbourne) Level 6, Suite 616 1 Queens Road Melbourne VIC 3004 Melbourne, Australia Tel: 03 9866 5277 Fax: 03 9866 5299 info_asiapacific@siemon.com Siemon China (Shanghai) Rm. 3407-3408, Hong Kong Square S. No. 283, Huai Hai Road Shanghai, 200021, P.R. China Tel: (86) 21 6390 6778 Fax: (86) 21 6384 0167 info_china@siemon.com Siemon China (Beijing) Suite 1108 SCITECH Tower 22 Jianguomenwai Avenue Beijing 100004, P.R. China Tel: (86) 10 6559 8860 Fax: (86) 10 6559 8867 info_china@siemon.com Siemon China (Guangzhou) Rm. 1104, Middle Tower, Times Square 28 Tianhebei Road Guangzhou, 510620, P.R. China Tel: (86) 20 3882 0055 Fax: (86) 20 3882 0575 info_china@siemon.com Siemon China (Chengdu) Rm. 1209-1210 Western China Business Tower No. 19,4 Section, Renminan Road Chengdu, Sichuan 610041, P.R. China Tel: (86) 28 6680 1100 Fax: (86) 28 6680 1096 Japan Siemon Japan 10F Meguro G Bldg. 1-4-16 Meguro, Meguro-ku, Tokyo, 153-0063 Japan Tel: 81 (3) 5437-1580 Fax: 81 (3) 5437-1581 info_japan@siemon.com 2007 Siemon WP-InfrastructureDesign_Rev.B 8/07