City of San Antonio (COSA) Boarding Homes Fire Sprinkler System Training



Similar documents
Roland Garcia Pearland Fire Department

INFORMATION BULLETIN 121c Requirements for Plumbing Limited Service and Repair Permits (LSR)

Requirements for Smoke/Carbon Monoxide & Fire Extinguisher Certification

Fire Alarm Systems Requirements by Occupancy Type

TEXAS STATE BOARD OF PLUMBING EXAMINERS EXAMINATION AND REGISTRATION Endorsement Training Programs

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

RULES OF DEPARTMENT OF MENTAL HEALTH AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER LIFE SAFETY LICENSURE RULES TABLE OF CONTENTS

How To Install A Carbon Monoxide Detector

ICC CODE CORNER 2012 IFC Code & Commentary

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

CHAPTER 9 FIRE PROTECTION SYSTEMS

Development Services Guidelines

Development Services Guidelines

Instructions for Obtaining a Certificate of Smoke Detector, Carbon Monoxide Alarm, and Kitchen Fire Extinguisher Compliance

BUILDING PERMIT APPLICATION APPLICABLE TO CITY LIMITS AND ETJ CHAPTER 18, General

Carbon Monoxide Alarms


RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

NFPA SELECT SIGNIFICANT CHANGES

Smoke & Carbon Monoxide

Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

Errata has been identified as follows:

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

Inspections must be conducted every three years in order to maintain an "approved" status on the City Of Bozeman Safe Rental Unit List.

Fraternity and Sorority House Fire Safety

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

FIRE SAFETY INSPECTION REPORT

PPM 591 HOME MODIFICATION

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

FIRE ALARM PLAN REVIEW. Office of the State Fire Marshal Massachusetts Department of Fire Services December 2009

Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) Fire Alarm Permit Application

TEXT (CO Detection Commercial Buildings Final) Part 1228 of Title 19 NYCRR is amended by adding a new section , to read as follows:

Smoke Detector/Carbon Monoxide Detector Inspections

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

FIRE SAFETY REQUIREMENTS

ORDINANCE NO. THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

908.7 (New) [IBC [F] (New)], (New), Chapter 47 (IBC Chapter 35)

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

FIRE SPRINKLERS IN TOWNHOMES/CONDOMINIUMS

Development Services Department City of San Antonio. Permits & Licenses. Development Services Manager. Deputy Historic Preservation Officer

Uniform With Exceptions

Pennsylvania Uniform Construction Code Homeowner s Guide

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

SUBCHAPTER F. SMOKE ALARMS AND FIRE EXTINGUISHERS

VILLAGE OF BETHALTO COMMERCIAL BUILDING PERMIT APPLICATION

Smoke & Carbon Monoxide

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

ESTABLISHMENT OF A NEW BUSINESS

CHAPTER 8. Village of Caledonia Alarm Systems Ordinance ( /01/13)

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

Effective June 27, TEXT (CO Detection Commercial Buildings)

How To Build A House In The United States

Minimum Housing and Health Standards

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

Guide to Massachusetts Smoke & Carbon Monoxide Requirements

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

How To Get A Fire Alarm Permit In Vail

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

CERTIFICATE OF COMPLIANCE

Inspection, Testing and Maintenance

City of Bettendorf Fire Alarm System Requirements

Fire Alarm Systems Permit Packet. City of Greer Fire Department

Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?

Contractor License Application

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

NOW, THEREFORE, BE IT ORDAINED by the Princeton Council as follows:

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

FOR CERTIFICATION AS PRESCRIBED BY THE STATE FIRE PREVENTION COMMISSION ON NOVEMBER 11, 2009 IN ACCORDANCE WITH THE STATE FIRE PREVENTION REGULATIONS

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

C I T Y O F S E L M A F I R E D E P A R T M E N T

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

Bureau Veritas Contact Information

EXISTING BUILDINGS AND STRUCTURES

BUILDING PERMIT SPECIFICATIONS

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

PLAN SUBMITTAL REQUIREMENTS FOR KITCHEN HOOD AND DUCT EXTINGUISHING SYSTEMS

Fire precautions in dwellings. Private sector housing Providing homes building communities

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

RRIO Checklist. Use of checklist: Definitions: Limitations

17 East Main Street Cuba,NewYork Code Enforcement

F.Y.I. Who Designs Fire Sprinkler Systems?

TOWN OF INDIALANTIC Brevard County, Florida APPLICATION FOR BUSINESS TAX RECEIPT (B.T.R.)

Inspecton Report. Property Address:

License fee is $45.00

Housing Quality Standards Inspection Checklist

Fire Log Book. Provided by Norfolk Fire & Rescue Service. Name and address of premises:...

Transcription:

City of San Antonio (COSA) Boarding Homes Fire Sprinkler System Training Development Services Department (DSD) & San Antonio Fire Department (SAFD) 1901 S. Alamo Wednesday, January 23, 2013 9:00 am 11:00 am

Outline Boarding Homes Ordinance Definitions Options for Fire Sprinkler Systems Fire Sprinkler Systems Types NFPA 13D, NFPA 13R Fire Sprinkler System Matrix Permitting Inspections Contact & More Information Questions

Boarding Homes Ordinance December 13, 2012, City Council: Passed Boarding Homes Ordinance Approved a new annual inspection program for boarding homes If legally in existence prior to adoption of ordinance Grandfathered to codes under which they were constructed Ordinance effective March 1, 2013 If not already legally in existence : Boarding homes registering before March 1, 2013, will have until December 31, 2013 to comply with fire sprinkler requirement Existing boarding homes annual registration, inspection and related requirements

Definitions International Building Code (IBC) Boarding Home: A building arranged or used for lodging for compensation, with or without meals, and not occupied as a single-family unit. COSA Ordinance Boarding Home Facility: Furnishes, in one or more buildings, lodging to three or more elderly and/or disabled persons who are unrelated to the owner of the establishment by blood or marriage; and Provides community meals, light housework, meal preparation, transportation, grocery shopping, money management, laundry services, or assistance with self-administration of medication to persons/residents who are capable of feeding, dressing, moving, self-evacuating, bathing, and attending to other personal needs or maintenance without assistance; and Does not provide personal care services to persons/residents. Transient: Occupancy of a dwelling unit or sleeping unit for not more than 30 days.

Fire SprinklerSystem Types NFPA 13D Transient (< 30 days) 10 or less residents; Non-transient 16 or less residents Designed and installed by licensed Fire Sprinkler Contractor or Master Plumber who holds the Multipurpose Fire Protection Sprinkler Specialist Endorsement Permitted and inspected by SAFD Plans reviewed by DSD Fire Team

Fire Sprinkler System Types NFPA 13D Residential sprinkler designed for one- or two-family dwellings and manufactured homes Least expensive to install No fire department connection required Intended for living spaces only Sprinklers not required in garages, open attached porches, carports or attics

Fire Sprinkler System Types NFPA 13R Transient (< 30 days) more than 10 residents Non-transient more than 16 residents Designed and installed by licensed Fire Sprinkler Contractor Permitted and inspected by SAFD Plans reviewed by DSD Fire Team

Fire Sprinkler System Matrix # Of Capable/ Transient/ IBC Minimum Sprinkler IBC Use Residents Not Capable* Not Transient Group System Type References < 10 - T R-3 13D 310.5, 903.2.8.1 Boarding >10 - T R-1 13R b 310.3, 903.2.8 Homes < 16 - NT R-3 13D 310.5, 903.2.8.1 >16 - NT R-2 13R b 310.4, 903.2.8 < 5 C - R-3 13D/P2904 308.3.1, 308.4.1, 903.2.8.2 Capable = capable of self preservation Not Capable = not capable of self preservation Footnote b = where the structure is 4 stories or less as defined by the International Building Code

Permitting NFPA13D & NFPA13R Applicable Forms IB107 Fire Sprinkler Permit Application and Checklist Location Online Plans and Calculations designed per NFPA 13D/13R submitted to Fire counter Applicable Code Interpretations (e.g., CI2010-016 Antifreeze system)

SAFD Boarding Home General Inspections Items Access and address Life safety systems Fire alarm (if applicable) and Fire sprinkler systems A semiannual Gas test if gas appliances are present Smoke & carbon monoxide detectors Fire Drills Egress Check locking devices on doors Burglar /Security bars Subject to review and approval by SAFD Laundry room check Check for extension cords Fire extinguishers Fixed pipe system

Inspections NFPA 13D & NFPA 13R Boarding Home Specific SAFD inspections questions contact Chief Randy Jenkins at 210.207.7967; Randy.Jenkins@sanantonio.gov General SAFD fire inspections questions contact Chief Matt Jimenez at 210.207.1438; Matias.Jimenez@sanantonio.gov

Fire Sprinkler Plan Review Contact Information Fire Protection Specialist Ms. Suanne Callow at 210.207.8160; Suanne.Callow@sanantonio.gov Sr. Fire Protection Engineer Ms. Jennifer G. Gallegos, PE, at 210.207.8056; Jennifer.Gallegos@sanantonio.gov

For More Information Department of Aging and Disability ttp://www.dads.state.tx.us/ COSA Boarding Home Website http://www.sanantonio.gov/boardinghomesordinance.aspx

For More Information Texas State Board of Plumbing Examiners - http://www.tsbpe.state.tx.us/index.html

For More Information State Fire Marshal s Office http://www.tdi.texas.gov/fire/index.html

Questions?