We are dedicated to your satisfaction before, during and after the inspection.



Similar documents
PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

Inspection Report. Client. Property Address: 1500 Imaginary Place McKinney Tx 75069

DFW Premier Home Inspections

I NI NP R Inspected Items

Property Inspection Report

ProSafe Home Inspections, Inc Connally Drive. Jacksonville, Texas Property Inspected:

PROPERTY INSPECTION REPORT

1000 Point TX Home Inspection

Home Inspection Report

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

Propery Inspection Report

PROPERTY INSPECTION REPORT


Report Identification: 123 Austin Park. Inspection Report. Travis Blake. Property Address: 123 Austin Park Autin TX 78645

PROPERTY INSPECTION REPORT

Stafford Inspections P.O. Box Dallas, TX PROPERTY INSPECTION REPORT

BullsEye Home Inspections P.O. BOX 1794 Grapevine, TX

COMPREHENSIVE PROPERTY INSPECTIONS

South Carolina Home Inspector Standards of Practice

HEDDERMAN ENGINEERING, INC Carrie Cove Ct., Spring, TX , fax

Inspecton Report. Property Address:

HOME INSPECTION CHECKLIST

HAPPY HOMEBUYER Somewhere St. Arland, Texas, This report was created exclusively for

PROPERTY INSPECTION REPORT

TREC SOLD TO: INVOICE NUMBER Flushwing Dr. Austin, TX 78754

111 Condo Circle Contents Property Inspection Report Information from the State of Texas and additional information from the inspector.

Professional Inspection Report

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

Vision Home Inspection

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

Home Inspection Report

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

10 Secrets of Home Inspections Every Home Buyer Should Know

Inspection Report. Prepared for: William Smith 2700 New Street Plano, TX 75025

Inspection Item COMMENTS

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

RRIO Checklist. Use of checklist: Definitions: Limitations

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Inspection Report. Bob and Betty Buyer. Property Address: 4567 Home street Anchorage AK Inspection Connection LLC

Self-Home Inspection Checklist

License Requirements for Persons Engaging in the Business of Inspection Practice:

HOMEOWNER S PERMIT GUIDE

A+ Home Inspections Cutten Parkway, Houston, TX Phone: (832) PROPERTY INSPECTION REPORT

GENERAL WIRING RULES FOR HOUSES

Final Walk-Through Checklist

A.C.E. Home Inspection Service St. Peters, MO (636)

How To Read A House Inspection Report

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

A Guide to Home Inspections

2. What building projects are exempted? (permit not required)

Vari Inspection Services

(817) (voice) / (817) (fax) victor@houseexamdfw.com

October 5, 2015 Dear Client,

PROPERTY INSPECTION REPORT

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

Home Management Checklist: Spring

Georgia Home Inspection Services

Building Permits: When are they required?

A Seller s Guide to the Home Inspection By

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

South Carolina Home Inspector Standards of Practice

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST

Does Wall Township require an inspection by the building department on resale of a home?

Inspection Tech. (330) Inspected By: Aaron Westerburg

INVOICE. DATE: May 11, DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

A Residential Owner s Guide to PERMITS. Elgin CITY OF PLANNING & NEIGHBORHOOD SERVICES

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

ALL TEX Inspections 650 Century Plaza #110, Houston, TX Phone: (713) Fax: (281)

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

JJ Henson 230 Five Oaks San Antonio, Texas "HOME INSPECTION REPORT" Joe Realtor 1234 Main St. 07/25/2013

The City of Basehor, Kansas

Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN USA Drive. Morris Home Inspection Group, LLC

Total Home Inspection Checklist

159 Morningside Avenue, Toronto

Rental Property Safety Inspection Checklist

WHEN IS A PERMIT REQUIRED?

James Price James Price dba WIN Home Inspection Lubbock (806)

INSPECTION REPORT. LOCATION OF PROPERTY 1234 Sample Street Tucson, AZ CLIENT Mr. & Mrs. John Q. Sample c/o Agent DATE OF INSPECTION 1/30/2008

PROPERTY INSPECTION REPORT

STATE OF SOUTH CAROLINA RESIDENTIAL PROPERTY CONDITION DISCLOSURE STATEMENT

Structure Survey Findings:

(Real Estate Office) (Agent)

Orlando Home Inspection Services

HEDDERMAN ENGINEERING, INC. Office , Fax

SWF Home Inspections

New Home Walk-Through Package

PROFESSIONAL ENGINEERING INSPECTIONS, INC.

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

2640 Fountain View Drive Houston, Texas P TTY OCCUPANCY TECHNICIAN: PHONE NUMBER:

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division

Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM

Exhibit B. Property Acquisition and Disposition Division Residential Design & Performance Standards

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

Transcription:

At-Ease Home Inspections Let us set your mind At-Ease 1301 E. Debbie Ln. Ste. 102 #188 Mansfield, TX. 76063 Direct 817-909-3254 Fax 817-417-0885 Home Inspection for John Doe Subject: 123 Anywhere Dallas, TX. 75014 We are dedicated to your satisfaction before, during and after the inspection. Promulgated by the Texas Real Estate Commission (TREC) P.O. Box 12188, Austin, TX 78711-2188, 1-800-250-8732 or (512) 459-6544 (http://www.trec.state.tx.us). REI 7A-1 Page 1 of 16

PROPERTY INSPECTION REPORT Prepared For: John Doe (Name of Client) Concerning: 123 Anywhere Dallas, TX. 75014 (Address or Other Identification of Inspected Property) By: Troy Thomas TREC #9957 01/01/2001 (Name and License Number of Inspector) (Date) (Name, License Number and Signature of Sponsoring Inspector, if required) This property inspection report may include an inspection agreement (contract), addenda, and other information related to property conditions. If any item or comment is unclear, you should ask the inspector to clarify the findings. It is important that you carefully read ALL of this information. This inspection is subject to the rules ( Rules ) of the Texas Real Estate Commission ( TREC ), which can be found at www.trec.state.tx.us. The TREC Standards of Practice (Sections 535.227-535.231 of the Rules) are the minimum standards for inspections by TREClicensed inspectors. An inspection addresses only those components and conditions that are present, visible, and accessible at the time of the inspection. While there may be other parts, components or systems present, only those items specifically noted as being inspected were inspected. The inspector is not required to move furnishings or stored items. The inspection report may address issues that are code-based or may refer to a particular code; however, this is NOT a code compliance inspection and does NOT verify compliance with manufacturer s installation instructions. The inspection does NOT imply insurability or warrantability of the structure or its components. Although some safety issues may be addressed in this report, this inspection is NOT a safety/code inspection, and the inspector is NOT required to identify all potential hazards. In this report, the inspector will note which systems and components were Inspected (I), Not Inspected (NI), Not Present (NP), and/or Deficient (D). General deficiencies include inoperability, material distress, water penetration, damage, deterioration, missing parts, and unsuitable installation. Comments may be provided by the inspector whether or not an item is deemed deficient. The inspector is not required to prioritize or emphasize the importance of one deficiency over another. Some items reported as Deficient may be considered life-safety upgrades to the property. For more information, refer to Texas Real Estate Consumer Notice Concerning Recognized Hazards, form OP-I. This property inspection is not an exhaustive inspection of the structure, systems, or components. The inspection may not reveal all deficiencies. A real estate inspection helps to reduce some of the risk involved in purchasing a home, but it cannot eliminate these risks, nor can the inspection anticipate future events or changes in performance due to changes in use or occupancy. It is recommended that you obtain as much information as is available about this property, including any seller s disclosures, previous inspection reports, engineering reports, building/remodeling permits, and reports performed for or by relocation companies, municipal inspection departments, lenders, insurers, and appraisers. You should also attempt to determine whether repairs, renovation, remodeling, additions, or other such activities have taken place at this property. It is not the inspector s responsibility to confirm that information obtained from these sources is complete or accurate or that this inspection is consistent with the opinions expressed in previous or future reports. Items identified in the report do not obligate any party to make repairs or take other action, nor is the purchaser required to request that the seller take any action. When a deficiency is reported, it is the client s responsibility to obtain further evaluations and/or cost estimates from qualified service professionals. Any such follow-up should take place prior to the expiration of any time limitations such as option periods. Evaluations by qualified tradesmen may lead to the discovery of additional deficiencies which may involve additional repair costs. Failure to address deficiencies or comments noted in this report may lead to further damage of the structure or systems and add to the original repair costs. The inspector is not required to provide follow-up services to verify that proper repairs have been made. Property conditions change with time and use. For example, mechanical devices can fail at any time, plumbing gaskets and seals may crack if the appliance or plumbing fixture is not used often, roof leaks can occur at any time regardless of the apparent Promulgated by the Texas Real Estate Commission (TREC) P.O. Box 12188, Austin, TX 78711-2188, 1-800-250-8732 or (512) 459-6544 (http://www.trec.state.tx.us). REI 7A-1 Page 2 of 16

condition of the roof, and the performance of the structure and the systems may change due to changes in use or occupancy, effects of weather, etc. These changes or repairs made to the structure after the inspection may render information contained herein obsolete or invalid. This report is provided for the specific benefit of the client named above and is based on observations at the time of the inspection. If you did not hire the inspector yourself, reliance on this report may provide incomplete or outdated information. Repairs, professional opinions or additional inspection reports may affect the meaning of the information in this report. It is recommended that you hire a licensed inspector to perform an inspection to meet your specific needs and to provide you with current information concerning this property. ADDITIONAL INFORMATION PROVIDED BY INSPECTOR Inspection Time In: 8:30am Time Out: 12:00pm_ Property was: Occupied / Vacant House Orientation (For Purpose Of This Report Front Faces) North / South / East/ West Weather Conditions During Inspection: Sunny / Overcast / Raining / Snowing Outside temperature during inspection: 60 or below / 60 to 70 / 70 to 80 / 80 to 90 / 90+ DEGREES Parties present at inspection: Buyer / Seller / Listing Agent / Buyers Agent / None Other: Promulgated by the Texas Real Estate Commission (TREC) P.O. Box 12188, Austin, TX 78711-2188, 1-800-250-8732 or (512) 459-6544 (http://www.trec.state.tx.us). REI 7A-1 Page 3 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected I NI NP NI=Not Inspected NP=Not Present D=Deficiency Inspection Item D I. STRUCTURAL SYSTEMS A. Foundations Type of Foundation(s): Slab-on grade Floor slopes are apparent in the forward most guest bedroom. This condition could indicate greater than normal movement within the structure and potential structural problems. Further investigation of the foundation is recommended. Notice: This inspection is one of first impression and the inspector was not provided with any historical information pertaining to the structural integrity of the inspected real property. This is a limited cursory and visual survey of the accessible general conditions and circumstances present at the time of this inspection. Opinions are based on general observations made without the use of specialized tools or procedures. Therefore, the opinions expressed are one of apparent conditions and not of absolute fact and are only good for the date and time of this inspection. The inspection of the foundation may show it to be providing adequate support for the structure or having movement typical to this region, at the time of the inspection. This does not guarantee the future life or failure of the foundation. The Inspector is not a structural engineer. This inspection is not an engineering report or evaluation and should not be considered one, either expressed or implied. If any cause of concern is noted on this report, or if you want further evaluation, you should consider an evaluation by an engineer of your choice. B. Grading & Drainage The grading should be improved to promote the flow of storm water away from the house. The ground should slope away from the house at a rate of one inch per foot for at least the first ten feet. Ideally, at least six (6) inches of clearance should be maintained between soil level and the top of the foundation walls. C. Roof Covering Materials Type(s) of Roof Covering: Asphalt composition shingle Viewed From: Walked on roof Damaged downspouts on the southwest corner should be repaired promptly. Notice: Life expectancy of the roofing material is not covered by this property inspection report. If any concerns exist about the roof covering life expectancy or potential for future problems, a roofing specialist should be consulted. The Inspector cannot offer an opinion or warranty as to whether the roof has leaked in the past, leaks now, or may be subject to future leaks, either expressed or implied. The inspection of this roof may show it to be functioning as intended or in need of minor repairs. This inspection does not determine the insurability of the roof. You are strongly encouraged to have your Insurance Company physically inspect the roof, prior to closing, to fully evaluate the insurability of the roof. This confidential report is prepared exclusively for John Doe Page 4 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected I NI NP NI=Not Inspected D NP=Not Present D=Deficiency Inspection Item D. Roof Structure & Attic Viewed From: Entered attic and performed a visual inspection Approximate Average Depth of Insulation: 5 inches plus Approximate Average Thickness of Vertical Insulation: 6 inches The roof structure and attic are performing as intended. No significant problems were observed. E. Walls (Interior & Exterior) Interior Walls: Evidence of patching was detected in various locations including but not limited to the master and forward guest bedrooms. Exterior Walls: The expansion gaps on both sides of the structure needs to be properly filled. F. Ceilings & Floors Ceilings: The ceilings are performing as intended. No significant problems were observed. Floors: Recommend adding the proper transition piece from the hallway to the hall bathroom flooring. Floor slopes are apparent in the forward most guest bedroom. This condition could indicate greater than normal movement within the structure and potential structural problems. Further investigation of the foundation is recommended. This confidential report is prepared exclusively for John Doe Page 5 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected I NI NP NI=Not Inspected D NP=Not Present D=Deficiency Inspection Item G. Doors (Interior & Exterior) Interior Doors: The interior doors are performing as intended. No significant problems were observed. Exterior Doors: The door between the garage and the interior of the house should be equipped with an auto-closer device to prevent automobile fumes from entering the house. The weather stripping at the bottom of the garage overhead door should extend all the way from one end to the other without a gap. Recommend having it replaced. The front doors doorknob doesn t respond properly, recommend having it replaced or repaired. The exterior trim around the back door shows some signs of water damage. Recommend having it repaired. H. Windows The window to the right in rear breakfast nook area is chipped in two places and should be repaired or replaced. The window to the left in the rear breakfast nook area was unable to be opened with a normal amount of force. Recommend having it repaired as needed. The damaged screen(s) were found on the window(s) should be repaired or replaced. Water damaged was noted on but not limited to the window sill of the window to the far right in the family room The second window from the left in the family room doesn t stay up on its own. Recommend having it repaired as needed. Recommend re-caulking the windows where needed to help prevent possible water penetration. This confidential report is prepared exclusively for John Doe Page 6 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected I NI NP NI=Not Inspected D NP=Not Present D=Deficiency Inspection Item The window to the middle bedroom is showing signs of separation from the structure. Recommend having it further investigated, repaired and monitored. I. Stairways (Interior & Exterior) J. Fireplace/Chimney Fireplace: The fireplace is performing as intended. No significant problems were observed. Chimney: Water damage was noted on the exterior trim of the chimney. Recommend having it repaired. K. Porches, Balconies, Decks, and Carports The porch is performing as intended. No significant problems were observed. This confidential report is prepared exclusively for John Doe Page 7 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected NI=Not Inspected NP=Not Present D=Deficiency I NI NP D Inspection Item II. ELECTRICAL SYSTEMS A. Service Entrance and Panels Service Entrance: The service entrance is performing as intended. No significant problems were observed. Panel Box: Box Rating and/or Main Disconnect Rating: 200amps/200amps Box Location: Garage This home does not meet current arc-fault circuit-interrupter (AFCI) requirements. This is an asbuilt condition, but Per TREC standards of practice we are required to report this condition as a deficiency. Some items reported as Deficient may be considered upgrades to the property. For more information, refer to Texas Real Estate Consumer Notice Concerning Recognized Hazards, form OP-I. B. Branch Circuits, Connected Devices, and Fixtures Type of Wiring: Copper The front porch light fixture needs to be tightened to the structure and sealed to help prevent possible water penetration. The outlet to the left of the master bathroom entrance has hot neutral in reverse. Recommend having it repaired as needed. The smoke detector in the forward most guest bedroom is not properly attached to the ceiling. Recommend having it properly secured. There are not enough smoke alarms located in the home. Under current building standards, there should be a smoke alarm located outside each separate sleeping area in the immediate vicinity of the sleeping rooms. This confidential report is prepared exclusively for John Doe Page 8 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected I NI NP NI=Not Inspected D NP=Not Present D=Deficiency Inspection Item III. HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS A. Heating Equipment Type of System: Central Forced Air Furnace Energy Source: Gas The thermostat is for a heat pump but the structure has a furnace. Recommend having it replaced. B. Cooling Equipment Type of System: Central Forced Air System The temperature drop measured across the evaporator coil of the air conditioning system is lower than considered typical. This usually indicates that servicing is needed. A qualified heating and cooling technician should be consulted to further evaluate this condition and the remedies available for correction. The outdoor unit of the air conditioning system is out of level. This should be improved. The area where the lines from the outdoor unit come into the structure needs to be sealed. C. Duct System, Chases, and Vents The duct system is performing as intended. No significant problems were observed. This confidential report is prepared exclusively for John Doe Page 9 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected NI=Not Inspected NP=Not Present D=Deficiency I NI NP D Inspection Item IV. PLUMBING SYSTEM A. Water Supply System and Fixtures Location of water meter: Front of Property Location of main water supply valve: Front of Property Static water pressure reading: Approximately 90psi plus As the static water pressure of the supply plumbing system exceeds 80 pounds per square inch (psi), it would be wise to install a pressure regulator. Otherwise, the plumbing system may be prone to leaks in piping, fittings or other equipment. The left knob to the laundry room washing machine connection should be red to represent hot water. The counter tops for the kitchen sink area and the island come loose and should be secured in place as needed. Water pressure was found to be low when tested with two fixtures operated simultaneously in both bathrooms. This condition should be investigated and/or repaired. The toilet is loose and should be re-secured in the master bathroom. Recommend having a stopper properly attached to the tub in the hall bathroom. B. Drains, Wastes, and Vents The DWV system is performing as intended. No significant problems were observed. C. Water Heating Equipment Energy Source: Gas Capacity: 50 Gallons The plumbing pipes at the top of the unit should be properly insulated to help prevent possible freezing during the winter months. The vent pipe serving the water heater does not have safe clearance from combustible materials. This condition should be improved for safety reasons. D. Hydro-Massage Therapy Equipment Access to the whirlpool motor should be provided (or its whereabouts should be verified with the current owner). This confidential report is prepared exclusively for John Doe Page 10 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected NI=Not Inspected NP=Not Present D=Deficiency I NI NP D Inspection Item V. APPLIANCES A Dishwasher The dishwasher is performing as intended. No significant problems were observed. B. Food Waste Disposer The food waste disposer is performing as intended. No significant problems were observed. C. Range Exhaust Vent The range exhaust vent is performing as intended. No significant problems were observed. D. Ranges, Cooktops, and Ovens The thermostat for the electric range was found to be inaccurate and should be repaired. The temperature was found to be greater than a 25 degree difference of 350 degrees as measured by a detached thermometer. E. Microwave Oven The microwave oven is performing as intended. No significant problems were observed. F. Trash Compactor G. Mechanical Exhaust Vents and Bathroom Heaters The mechanical exhaust vents are performing as intended. No significant problems were observed. H. Garage Door Operator(s) The garage door opener did not automatically reverse under resistance to closing. There is a serious risk of injury, particularly to children, under this condition. Improvement may be as simple as adjusting the sensitivity control on the opener. This should be repaired immediately. I. Doorbell and Chimes The doorbell and chimes are performing as intended. No significant problems were observed. This confidential report is prepared exclusively for John Doe Page 11 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected NI=Not Inspected NP=Not Present D=Deficiency I NI NP D Inspection Item J. Dryer Vents Due to the current homeowner having a dryer hooked up at the time of the inspection the vent could not be inspected. This confidential report is prepared exclusively for John Doe Page 12 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected I NI NP NI=Not Inspected D NP=Not Present D=Deficiency Inspection Item VI. OPTIONAL SYSTEMS A. Lawn and Garden Sprinkler Systems Broken sprinkler heads were noted. This condition should be remedied to ensure adequate spray coverage for the entire sprinkler system. B. Swimming Pools, Spas, Hot Tubs, and Equipment Type of Construction: Not Present C. Outbuildings D. Outdoor Cooking Equipment Energy Source: Not Present E. Gas Supply Systems The gas lines were not inspected or tested. The home inspector is not allowed to test the gas line(like the gas company), thus it is recommended that the buyer contact the gas company in order to test the gas pressure and verify that no gas leak exist before the closing day. F. Private Water Wells (A coliform analysis is recommended.) Type of Pump: Not Present Type of Storage Equipment: Not Present This confidential report is prepared exclusively for John Doe Page 13 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected NI=Not Inspected NP=Not Present D=Deficiency I NI NP D Inspection Item G. Private Sewage Disposal (Septic) Systems Type of System: Not Present Location of Drain Field: Not Present The inspector was not informed of the house being on a septic system. H. Whole-House Vacuum Systems I. Other Built-in Appliances This confidential report is prepared exclusively for John Doe Page 14 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected NI=Not Inspected NP=Not Present D=Deficiency I NI NP D Inspection Item ADDENDUM: REPORT SUMMARY The following is a synopsis of the potentially significant improvements that should be budgeted for over the short term. Other significant improvements, outside the scope of this inspection, may also be necessary. Please refer to the body of this report for further details on these and other recommendations. For your convenience, the following conventions have been used in this summary addendum. Major Concerns: a system or component which is considered significantly deficient or is unsafe. Significant deficiencies need to be corrected and, except for some safety items, are likely to involve significant expense. Safety Issues: denotes a condition that is unsafe and in need of prompt attention. Repair Items: denotes a system or component which is missing or which needs corrective action to assure proper and reliable function. Improvement Items: denotes improvements which are recommended but not required. Items To Monitor: denotes a system or component needing further investigation and/or monitoring in order to determine if repairs are necessary. Deferred Cost Items: denotes items that have reached or are reaching their normal life expectancy or show indications that they may require repair or replacement anytime during the next five (5) years. MAJOR CONCERNS The inspection of the property listed above must be performed in compliance with the rules of the Texas Real Estate Commission (TREC). SAFETY ISSUES The door between the garage and the interior of the house should be equipped with an auto-closer device to prevent automobile fumes from entering the house. This home does not meet current arc-fault circuit-interrupter (AFCI) requirements. This is an as-built condition, but Per TREC standards of practice we are required to report this condition as a deficiency. Some items reported as Deficient may be considered upgrades to the property. For more information, refer to Texas Real Estate Consumer Notice Concerning Recognized Hazards, form OP-I. There are not enough smoke alarms located in the home. Under current building standards, there should be a smoke alarm located outside each separate sleeping area in the immediate vicinity of the sleeping rooms. The vent pipe serving the water heater does not have safe clearance from combustible materials. This condition should be improved for safety reasons. The garage door opener did not automatically reverse under resistance to closing. There is a serious risk of injury, particularly to children, under this condition. Improvement may be as simple as adjusting the sensitivity control on the opener. This should be repaired immediately. REPAIR ITEMS Floor slopes are apparent in the forward most guest bedroom. This condition could indicate greater than normal movement within the structure and potential structural problems. Further investigation of the foundation is recommended. The temperature drop measured across the evaporator coil of the air conditioning system is lower than considered typical. This usually indicates that servicing is needed. A qualified heating and cooling technician should be consulted to further evaluate this condition and the remedies available for correction. IMPROVEMENT ITEMS This confidential report is prepared exclusively for John Doe Page 15 of 16

Report Identification: 123 Anywhere, Dallas, TX. 75014 I=Inspected NI=Not Inspected NP=Not Present D=Deficiency I NI NP D Inspection Item ITEMS TO MONITOR The window to the middle bedroom is showing signs of separation from the structure. Recommend having it further investigated, repaired and monitored. DEFERRED COST ITEMS This confidential report is prepared exclusively for John Doe Page 16 of 16