The on-load tap-changer for maximum switching frequency more switching operations without needing maintenance

Similar documents
The On-Load Tap-Changer for Maximum Switching Frequency More Switching Operations without Needing Maintenance.

TAPCON 230 user-friendly, flexible and reliable

Product Overview MESSKO

THE OLTC AS AN "OIL ISOLATED SYSTEM" IN THE TRANSFORMER & OIL ANALYSIS IN OLTC. I Hr. Dr. Hurm, Hr. Dr. Schübel I I

Power transformers. Special transformers Railway

Dry-type transformers. Dry-type transformers from ABB The ideal solution for the oil and gas industry

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Data Sheet PS1B Pressure Switch

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

Ralf Christian, CEO Low and Medium Voltage. Making Things Right with Totally Integrated Power (TIP)

SR Door co-ordinators

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Integrated Custom Systems

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

WVC300 Micro-inverter solar grid system (Power line communications)

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Bar code scanners CLV45x / CLV450 / Standard Density

DISCONNECTORS AND LOAD SWITCHES for railways

Photovoltaic Solar Energy Unit EESFB

Micro Motion 3098 Gas Specific Gravity Meter

Remote Desktop Connection

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH INNOVATIONS FOR POWERFUL PERFORMANCES

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

INVITATION JUNE BERLIN ALL ABOUT TRANSFORMERS

Technical. Specifications. fischer Rugged Flash Drive. New. Rugged Solution for Safe Data Storage in Harsh Environment

Setting a Global Standard. SingleBore Subsea Completion System

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

T Substation Maintenance and Commissioning Test Equipment

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Series 8146/5-V37 and Series 8150/5-V37

Low Pressure Molding Solutions

Transformers. Special transformers Reactors products

Float & Tape Tank Gauging Solutions for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory-Grade Level Measurement

Sterilizers with extra class

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

The Best of Boiler Efficiency. The comprehensive product range for intelligent on-load boiler cleaning

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Product Summary. KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue. The art of handling air. Special leaflet SP/1/EN/7

The advice. The expertise. Wherever you are.

We turn sun energy into earning power. Solar power plants by and with Phoenix Solar

Plug and Socket Devices CES 63 A Series 8579

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Distribution Voltage Regulators

Bar code scanners CLX49x / CLX490 / Standard Density

NSK representative office Manila tel:

Transformer oil cooler ALFA A02

High-efficient gas boiler CompactGas

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PRECISION I RELIABILITY I PERFORMANCE. Cryogenic Testing. Experience a new level of performance

FastMig KMS 400 MVU EN NO. Operating manual. Brugsanvisning

LVDGROUP.COM CUSTOMER SERVICE

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Analytical Report RF high voltage cable accessories market

Polaris 5xx/7xx Medical Lights and Video

HOSCH. Sprung blade scraper with heating system. Documentation Type B6C/H

Technical Data. Dimensions

PAK. PakMaster XL PLUS-CE Series. PLUS The New SureLok Torch! Air Plasma Cutting Systems. Over 40 Years of Plasma Cutting Innovation

FP2 Relay. The Best Relaytion

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Rittal TopTherm fan-and-filter unit

Pluggable interface relays CR-P Pcb relays

ADM1TE 5/30A DIN rail single phase two wire energy meter

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

UFES Active protection for switchgear

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

PS-SEAL PTFE based high performance seal

GE Grid Solutions. Providing solutions that keep the world energized Press Conference Call Presentation November 12, Imagination at work.

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

ABB Power Electronics. Product Life Cycle Management Committed to operational reliability

NATUS SOLUTIONS Turnkey Project Management Project Engineering and Industrial Installations. Electrotechnical Solutions at the Highest Level

Understanding European versus U.S. temperature code ratings for solenoidoperated. A White Paper From ASCO

Material test chamber with mechanical convection

Mecc Alte 400Hz In Depth

PRODUCT INFORMATION. SICK Remote Service Product and System Support. Secure remote monitoring for efficient service

Basic Load Tap Changer Operation

Agilent 87421A/87422A Power Supply

NEUMAN & ESSER SEISMIC AIR POWER SYSTEMS

Providing a complete Ethernet anywhere solution. IS Ethernet Solutions

LASER CUTTING MACHINE AXEL 4020

Plug and Socket Devices SolConeX 16 A Series 8570

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

The Professional Choice. LDC With DC motor. OLAER LDC optimized for mobile use

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Transformer Fleet Management with e-terraassetcare

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Secure Data Drive Safe storage of sensitive data in harsh environments

A good connection. International approvals.

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Transcription:

Transformer Control On-Load Tap-Changers VACUTAP VR I HD The on-load tap-changer for maximum switching frequency more switching operations without needing maintenance

VACUTAP VR I HD new and even more cost effective Today s on-load tap-changers for regulating transformers are subject to very extreme demands. Our answer to this is the new VACUTAP VR I HD steady further development of the VACUTAP VR vacuum on-load tap-changer which has been providing reliable service since 2004. The new on-load tap-changer which is optimized for applications with high, above average switching rates performs even more switching operations without maintenance, thus giving you more transformer operating time. And the best thing about all this: Almost all VACUTAP VR I s delivered up to now can be retrofitted. Developed for maximum switching frequencies take advantage of longer maintenance intervals The new VACUTAP VR I HD does not have time-based maintenance. Instead the next maintenance job is not performed until after the VACUTAP VR I HD has performed 600,000 switching operations. The diverter switch insert doesn t even need to be replaced until after 1.2 million switching operations. This means a further reduction in operating costs coupled with maximum quality and highest environ-mental and safety standards. You profit from short down times and maximum productivity. To be able to ensure this quality at all times, we depend on the exclusive use of vacuum interrupters for the VACUTAP VR I HD as with all VACUTAP on-load tap-changers. These vacuum interrupters were especially developed and optimized for use in on-load tap-changers. They are manufactured exclusively in accordance with our strict specifications and have been giving dependable service now for years. Advantages: Maintenance intervals increased to 600,000 switching operation, added cost reduction over the entire useful life of the VACUTAP VR I HD. Ready to handle harshest of demands at all times The new VACUTAP VR I HD guarantees precise switching procedures under the harshest of conditions. This also includes applications such as electrolysis, phase shifters or HVDC (High Voltage Direct Current) transmission in addition to furnace operation. MR vacuum on-load tap-changers are not only used worldwide in many steel and aluminum mills but also on drilling rigs in potentially explosive environments or in chemical plants with aggressive or polluted surroundings. Since MR is the first and the sole manufacturer of on-load tap-changers that has had the VV and VR on-load tap-changers certified in accordance with 94/9/EG (ATEX) guidelines (in conformance with IEC and NEC 505 in North America). Advantage: Precise switching procedures even under the most extreme of conditions. 2

Transformer Control On-Load Tap-Changers VACUTAP VR I HD Can be 100% retrofitted easy to install later on The VACUTAP VR I HD can be retrofitted and is fully compatible with almost all already delivered VACUTAP VR I on-load tapchangers. Easy to change since the dimensions of the diverter switch insert are the same as those of almost all VACUTAP VR s delivered up to now. Advantage: Almost all VACUTAP VR I OLTCs which have been delivered up to now can be retrofitted. MR tested maximum safety during long-term operation We also followed MR s philosophy of strict protection when we developed the VACUTAP VR I HD. In our worldwide unique test lab, this OLTC was subjected to mechanical and electrical lifespan tests with far higher demands than IEC standards require. For example, switching capacity trials were performed with 600,000 switching operations instead of the required 50,000 switching operations. Advantage: Unbeatable safety during daily operation. Environmentally-friendly technology sustainable during daily use The VACUTAP VR I HD is distinguished by its environmentallyfriendly vacuum technology. In contrast to conventional oil switching technology, we ensure that no cutoff arcs are created in the insulating oil. This means you don t need an oil filter system either during operation. In addition, the new generation of onload tap-changers is designed for selected, alternative insulating fluids. Advantages: Environmentally-friendly operation, low disposal costs for soiled insulating fluids. 3

On-load tap-changer VRC I HD 401 VRC I HD 551 VRC I HD 701 VRC I HD 1001 VRC I HD 1301 VRE I HD 701 VRE I HD 1001 VRE I HD 1301 VRD I HD 1301 VRF I HD 1001 VRG I HD 1001 VRF I HD 1301 VRG I HD 1301 Number of phases and application 1 1 1 1 1 1 1 1 1 1 1 Max. rated through current I um (in A) 400 550 700 1000 1300 700 1000 1300 1300 1000 1300 Rated short-time current (in ka) 6 8 10 12 15 10 12 15 15 12 15 Rated short-circuit duration (in s) 3 3 3 3 3 3 3 3 3 3 3 Rated short-circuit current (in ka) 15 20 25 30 37,5 25 30 37,5 37,5 30 37,5 Max. rated step voltage U im (in V) 1) 3300 3300 3300 3300 3300 4000 4000 4000 3300 4000 4000 Switching capacity P StN (in kva) 1320 1500 1500 1500 1500 2800 3000 3000 1500 3000 3000 Rated frequency (in Hz) 50 60 Operating positions Without change-over selector: max. 18, with change-over selector: max. 35 1) 1) A 10% violation in excess of the max. rated step voltage caused by overexitation of the transformer is permitted if the switching capacity is not exceeded too. 2) VRC in special model with multiple coarse change-over selector possible up to a max. of 107 positions. 4500 Switching capacity diagram, VRC-VRE I HD in arcing furnace operation 4500 Switching capacity diagram, VRD-VRF I HD in arcing furnace operation Rated step voltage Ui [V] 4000 3500 3000 2500 2000 1500 1000 500 0 VRC I HD 401 VRC I HD 551 VRC I HD 701 VRE I HD 701 1500 kva 3000 kva 0 200 400 600 800 1000 1200 1400 Rated through current I u [A] VRC I HD 100 1 VRE I HD 100 1 VRC I HD 130 1 VRE I HD 130 1 Rated step voltage Ui [V] 4000 3500 3000 2500 2000 1500 1000 500 0 1500 kva 3000 kva 0 200 400 600 800 1000 1200 1400 Rated through current I u [A] VRF I HD 100 1 VRD I HD 130 1 VRF I HD 130 1

Transformer Control On-Load Tap-Changers VACUTAP VR I HD Example On-load tap-changer designations Type VACUTAP VRC VRC VACUTAP VRD VRD VACUTAP VRE VRE VACUTAP VRF VRF VACUTAP VRG VRG Number of phases 1 phase I I um (in A) VRC I 400 VRC I 550 VRC I, VRE I 700 VRC I, VRE I, VRF/VRG I 1000 VRC I, VRE I, VRD I, VRF/VRG I 1300 Number of parallel sectors 1 sector 1 U m (in kv) VRC, VRE, VRD, VRF, VRG 72,5 VRC, VRE, VRD, VRF, VRG 123 VRC, VRE, VRD, VRF, VRG 170 VRC, VRE, VRD, VRF, VRG 245 VRC, VRE, VRD, VRF, VRG 300 VRC, VRE 362 Tap selector series VRC, VRE B VRC, VRE, VRD, VRF C VRC, VRE, VRD, VRF D VRC, VRE DE VRG E Number of max. 10 10 operating positions without change-over 12 12 selector 14 14 16 16 18 18 Number of max. 19 19 operating positions with change-over 23 23 selector 27 27 31 31 35 35 Mid positions 0 Mid position (without change-over selector) 0 1 Mid position 1 3 Mid positions 3 Change-over selectors Reversing change-over selector W Coarse change-over selector G VRF I HD 1301 72,5 / C 10 19 1 G Basic circuit diagram 7

Transformer Control On-Load Tap-Changers VACUTAP VR I HD Advantages over conventional oil switching technology Vacuum technology is distinguished by its low power consumption during the switch-off procedure in the vacuum interrupters. Due to the hermetically sealed switching chamber, arcs never come in contact with the extinguishing agent. This makes the switching characteristics independent of the surrounding medium. Advantages: No cutoff arcing in the on-load tap-changer oil No oil filter system needed Clean oil simplifies and speeds up maintenance work Much lower maintenance frequency in comparison to conventional oil switching technology Extra: The constant switching capacity over the entire lifespan of the vacuum interrupters. The vacuum quality in the tubes is improved even more during the switching procedures because the metal vapor plasma created by the arc binds free gas molecules from the contact material (getter effect). In addition, there is no oxidation of the contact surface. This ensures a uniformly good transition resistance. Easy offer preparation simplified planning and ordering To be able to prepare you an offer that is customized to your needs, we usually only need a current/voltage table from the transformer manufacturer in addition to the basic data of the transformer. We will contact the transformer manufacturer for you if further questions should arise during the design of the on-load tap-changer. Advantages: High degree of offer transparency, clear cost structure. Vacuum interrupters made exclusively for MR optimized for use in on-load tap-changers. Your advantage even in aggressive and/or polluted surroundings: TAPMOTION ED motor drive-unit standardly designed for IP 66 class protection and available as version with ATEX 95 certification. 5

The world market s leading company the perfect partner for those who expect only the best Maschinenfabrik Reinhausen GmbH (MR) is the largest company of the REINHAUSEN Group, both in sales and number of employees. Founded in 1901, MR is today considered the world s leading premium provider of on-load tap-changers for regulating power transformers. All our products meet highest standards when it comes to quality, reliability and endurance strength. Proof of our extraordinary market position - more than 50% of the world s electrical current flows through MR on-load tap-changers. Behind all this is our edge in expertise, gained from more than 80 years of experience in this specialist field. Our experts are familiar with the requirements of both end customers and transformer manufacturers. This knowledge drives our innovations and is also used to provide challenging special solutions. In addition, it enables us to continually set new standards, which are then used by the entire industry sector. We use our research and development center in Regensburg, unique worldwide, for this purpose. Every product that leaves our company has been tested against the applicable standards and beyond. That s how we ensure that our customers get exactly what they expect from us failure-free regulation of their transformers, even under extreme conditions and over a period of several years. Our responsibility does not stop at delivery. We will remain your absolutely reliable partner over the entire lifetime of the product. And that can be 50 years or more. Even after this time, our customers will receive the necessary service, maintenance and spare parts. Because what we make lasts a long time. That s a sure thing. The densest service network worldwide no matter where you are, we are close by Maximum precision and perfection are demanded of our products - and that of course applies for our service as well. To ensure this, we depend on a unique, closely-knit, worldwide network made up of certified premium service providers. These premium service providers are thoroughly trained in accordance with our regulations and also attend instruction courses at regular intervals. MR service means: 24-month warranty on all services Service engineers on site within 24 hours Access to original MR spare parts over decades Experience gained from thousands of service calls Preparation of individual service strategies Training courses for your service personnel at our training centers 8

Transformer Control On-Load Tap-Changers VACUTAP VR I HD Your one-stop provider everything in MR quality MR is your reliable partner for all power transformer issues and system provider for all products in the areas of Power Transmission, Power Distribution, Automation & Control, Asset Management Solutions, Power Composites and Power Quality. Power Transmission, Power Distribution On-load tap-changers VACUTAP, OILTAP Off-circuit tap-changers DEETAP, COMTAP Drives TAPMOTION Temperature monitoring COMPACT, TRASY2, MDiT Intelligent fan control MTeC Buchholz relay MSafe Flow indicators MFloC Oil level indicators MTO, MMK Pressure relief devices MPreC Dehydrating breathers MTraB Sensors, accessories Smart Grid Solutions Automation & Control Voltage regulator TAPCON Monitoring systems TAPGUARD and TRAFOGUARD Asset Management Solutions On-load tap-changer service and support Training Spare parts Retrofit solutions for all products Power Composites Composite hollow isolators ReCoTec Glass fiber reinforced plastic (GFRP) tubes ROTAFIL Power Quality Compensation systems for all voltage levels Components, network studies 9

Transformer Control On-Load Tap-Changers VACUTAP VR I HD MR WORLDWIDE AUSTRALIA REINHAUSEN AUSTRALIA PTY. LTD. 17/20 22 St Albans Road, Kingsgrove, NSW, 2208 Phone: +61 2 9502 2202 Fax: +61 2 9502 2224 Email: sales@au.reinhausen.com BRAZIL MR DO BRASIL INDÚSTRIA MECÁNICA LTDA. Av. Elias Yazbek, 465, CEP: 06803-000 Embu - São Paulo Phone: +55 11 4785 2150 Fax: +55 11 4785 2185 Email: vendas@reinhausen.com.br CANADA REINHAUSEN CANADA INC. 3755, rue Java, Suite 180 Brossard, Quebec J4Y 0E4 Phone: +1 514 370 5377 Fax: +1 450 659 3092 Email: m.foata@ca.reinhausen.com INDIA EASUN-MR TAP CHANGERS (P) LTD. 612, CTH Road, Tiruninravur, Chennai 602 024 Phone: +91 44 26300883 Fax: +91 44 26390881 Email: easunmr@vsnl.com INDONESIA PT. REINHAUSEN INDONESIA German Center, Suite 6310, Jl. Kapt. Subijanto Dj. BSD City, Tangerang 15321 Phone: +62 21 2565 0045 Fax: +62 21 2565 0046 Email: c.haering@id.reinhausen.com IRAN IRAN TRANSFO AFTER SALES SERVICES CO. Zanjan, Industrial Township No. 1 (Aliabad) Corner of Morad Str., Postal Code 4533144551 Email: itass@iran-transfo.com ITALY REINHAUSEN ITALIA S.R.L. Via Alserio, 16, 20159 Milano Phone: +39 02 694 3471 Fax: +39 02 694 347 66 Email: sales@it.reinhausen.com JAPAN MR JAPAN CORPORATION German Industry Park, 1-18-2 Hakusan Midori-ku, Yokohama 226-0006 Phone: +81 45 929 5728 Fax: +81 45 929 5741 LUXEMBOURG REINHAUSEN LUXEMBOURG S.A. 72, Rue de Prés, L-7333 Steinsel Phone: +352 27 33 471 Fax: +352 27 33 4799 Email: sales@lu.reinhausen.com MALAYSIA REINHAUSEN ASIA-PACIFIC SDN. BHD. Level 11 Chulan Tower, No. 3 Jalan Conlay 50450 Kuala Lumpur Phone: +60 3 2142 6481 Fax: +60 3 2142 6422 Email: mr_rap@my.reinhausen.com P.R.C. (CHINA) MR CHINA LTD. (MRT) 开德贸易 ( 上海 ) 有限公司中国上海浦东新区浦东南路 360 号新上海国际大厦 4 楼 E 座, PC: 200120 电话 : +86 21 6163 4588 传真 : +86 21 6163 4582 邮箱 : mr-sales@cn.reinhausen.com mr-service@reinhausen.com 公司主页 : www.mr-china.cn RUSSIAN FEDERATION OOO MR Naberezhnaya Akademika Tupoleva 15, Bld. 2 ( Tupolev Plaza ), 105005 Moscow Phone/Fax: +7 495 980 89 67 Email: mrr@reinhausen.ru SOUTH AFRICA REINHAUSEN SOUTH AFRICA (PTY.) LTD. No. 15, Third Street, Booysens Reserve, Johannesburg Phone: +27 11 835 2077 Fax: +27 11 835 3806 Email: support@za.reinhausen.com SOUTH KOREA REINHAUSEN KOREA LTD. 21F, Korea SC First Bank Building, 100 Gongpyeong-dong, Jongno-gu, Seoul, 110-702 Phone: +82 2 767 4909 Fax: +82 2 736 0049 Email: you-mi.jang@kr.reinhausen.com USA REINHAUSEN MANUFACTURING INC. 2549 North 9 th Avenue, Humboldt, TN 38343 Phone: +1 731 784 7681 Fax: +1 731 784 7682 Email: sales@reinhausen.com UNITED ARAB EMIRATES REINHAUSEN MIDDLE EAST FZE Dubai Airport Freezone, Building Phase 6 3 rd floor, Office No. 6EB, 341 Dubai Phone: +971 4 2368 451 Fax: +971 4 2368 225 Email: service@ae.reinhausen.com Please note: The data in our publications may differ from the data of the devices delivered. We reserve the right to make changes without notice. IN2197390/01 EN VACUTAP VR I HD F0220801 01/12 uw Maschinenfabrik Reinhausen GmbH 2011 Maschinenfabrik Reinhausen GmbH Phone: +49 941 4090 0 www.reinhausen.com Falkensteinstrasse 8 Fax: +49 941 4090 7001 93059 Regensburg, Germany Email: sales@reinhausen.com