FastMig KMS 400 MVU EN NO. Operating manual. Brugsanvisning
|
|
|
- Agnes Terry
- 9 years ago
- Views:
Transcription
1 FastMig KMS 400 MVU Operating manual Brugsanvisning NO
2
3 Operating manual English
4 Contents 1. Preface General Product introduction Operation control and connectors Accessories Remote control devices Cables Installation Positioning of the machine Distribution network Connection to the mains supply Welding and earth cables Operation control switches and potentiometers Main switch I/O Pilot lamps Operation of cooling fan Manual metal arc welding Maintenance Cables Power source Regular maintenance Operation disturbances Operation of the overload protection Control fuses Under- and overvoltages in the mains supply Loss of a phase in the mains supply Disposal of the machine Ordering numbers Technical data FastMig KMS 400 MVU
5 1. Preface 1.1 General Congratulations on choosing the FastMig welding equipment. Used correctly, Kemppi products can significantly increase the productivity of your welding, and provide years of economical service. This operating manual contains important information on the use, maintenance and safety of your Kemppi product. The technical specifications of the equipment can be found at the end of the manual. Please read the manual carefully before using the equipment for the first time. For your own safety and that of your working environment, pay particular attention to the safety instructions in the manual. For more information on Kemppi products, contact Kemppi Oy, consult an authorised Kemppi dealer, or visit the Kemppi web site at The specifications presented in this manual are subject to change without prior notice. Important notes Items in the manual that require particular attention in order to minimise damage and personal harm are indicated with the NOTE! notation. Read these sections carefully and follow their instructions. Disclaimer While every effort has been made to ensure that the information contained in this guide is accurate and complete, no liability can be accepted for any errors or omissions. Kemppi reserves the right to change the specification of the product described at any time without prior notice. Do not copy, record, reproduce or transmit the contents of this guide without prior permission from Kemppi. Kemppi Oy /
6 1.2 Product introduction FastMig KMS 400 MVU is multi-operator power source designed for demanding professional use. It is suitable for MMA and MIG welding in DC Operation control and connectors H11 01 S11 H12 X14 6,3A F11 X12 X11 X13 X15 F11 Fuse for connection for 6,3 A delayed X12 Earth connection control table H11 Signal lamp I/O X14, X15 Connection for control cable parallel H12 Warning lamp for 01 Inlet of mains cable thermal protection S11 Main switch I/O X11, X13 Welding connection parallel 4 FastMig KMS 400 MVU
7 1.3 Accessories Remote control devices R Control of MMA/TIG welding current, reference scale 1 5. R Wire feed adjustment, electrode current adjustment. 2. Voltage adjustment. MIG-MAG remote control device with controls for wire feed and voltage, memory scales 1 5. You can use control device also for control of MMA current Cables FastMig KMS 400 MVU 16d Extension cable for remote control 20 Earth cable 21 MMA welding cable R10, R20 Remote control devices Kemppi Oy /
8 2. Installation 2.1 Positioning of the machine Place the machine on a firm, dry and level surface. Where possible, do not allow dust or other impurities to enter the machines cooling air flow. Preferably site the machine above floor level; for example on a suitable carriage unit. Notes for positioning the machine The surface inclination should not exceed 15 degrees. Ensure the free circulation of the cooling air. There must be at least 20 cm of free space in front of and behind the machine for cooling air to circulate. Protect the machine against heavy rain and direct sunshine. Note! The machine should not be operated in the rain as the protection class of the machine, IP23S, allows for outside preserving and storage only. Note! Never aim metallic grinding spray/sparks towards the equipment. 2.2 Distribution network All regular electrical devices without special circuits generate harmonic currents into distribution network. High rates of harmonic current may cause losses and disturbance to some equipment. This equipment complies with IEC provided that the short-circuit power Ssc is greater than or equal to 4.7 MVA at the interface point between the user s supply and the public supply network. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to 4.7 MVA. 2.3 Connection to the mains supply FastMig power sources are delivered equipped with 5 m mains cable without plug. If local electricity regulations of operating country are stating otherwise, the mains cable should be replaced in conformity with the local regulations. Connection of the mains cable, mounting and change of the plug should only be carried out by a competent electrician. Remove the machine s right side plate to enable the mounting of a mains cable. KMS 400 MVU power source can be connected to the mains supply of 230 V 3~ or 400 V 3~. If changing the mains cable take into consideration the following: The cable is entered into the machine through the inlet ring on the rear panel of the machine and fastened with a cable clamp (05). The phase conductors of the cable are coupled to connectors L1, L2 and L3. The earth protection coloured green-yellow is coupled to connector. NOTE! If you are using 5-lead cable, do not connect neutral conductor. 6 FastMig KMS 400 MVU
9 Sizes of the mains cables and fuse ratings for the machine at 100 % duty cycle are specified in the table below: Rated voltage Fuses, slow-blow Connection cable *) mm² 400 V 3~ 35 A H07RN-F 4G10 (10 mm²) 230 V 3~ 50 A H07RN-F 4G10 (10 mm²) *) In cables of S type there is a protective grounding conductor coloured green-yellow. 2.4 Welding and earth cables Recommended copper cables with cross-sectional area are as follows: FastMig KMS 400 MVU mm² In enclosed table are shown typical load capacities of rubber insulated copper cables, when ambient temperature is 25º C and lead temperature is 85º C. Cable Duty cycle ED Voltage loss / 10 m 100 % 60 % 30 % 50 mm² 285 A 370 A 520 A 0,35 V / 100 A 70 mm² 355 A 460 A 650 A 0,25 V / 100 A 95 mm² 430 A 560 A 790 A 0,18 V / 100 A Do not overload welding cables due to voltage losses and heating. Fasten the earth clamp of the return current cable carefully, preferably direct onto the piece to be welded. The contact surface of the earth clamp should always be as large as possible. Clean the fastening surface from paint and rust. 3. Operation control switches and potentiometers 3.1 Main switch I/O When you turn the switch into I-position, pilot lamp H11 on the front face is illuminated and the machine is ready for use. Note! Always turn the machine on and off with the mains switch, never use the mains plugs as a switch. 3.2 Pilot lamps The pilot lamps of the machine report the electric operation: The green pilot lamp H11 when lit indicates that the machine is on and ready for use and it is connected to the mains supply with the main switch in the I-position. H12 indicates when lit that the thermal protection of the machine has been activated due to over heating. The cooling fan will continue to run and cool the machine down and when the lamp is off the machine is ready to weld. 3.3 Operation of cooling fan In FastMig power sources there are two simultaneously operating fans. The fan is started for a moment when main switch is placed into position I. The fan will start during welding as the machine heats up and it will run for 1 to 10 minutes after the welding has stopped. Kemppi Oy /
10 4. Manual metal arc welding The FastMig power source can be used in electrode welding by connecting a FastMig MFS 53, MFS 55 or MSF 57 wire feeder to it. The power source can be made suitable for electrode welding without a wire feeder by connecting an R10 or R20 remote control to the X14 or X15 terminal at the back of the power source for welding current adjustment, and the welding power cable connected to the power source s (+) connector X11 or X Maintenance The amount of use and the working environment should be taken into consideration when planning the frequency of maintenance of the machine. Careful use and preventive maintenance will help to ensure trouble-free operation. 5.1 Cables Check the condition of welding and connection cables daily. Do not use damaged cables. Make sure that the mains cables in use are safe and according to laid down regulations. The repair and mounting of a mains connection cable should be carried out only by an authorised electrician. 5.2 Power source Note! Disconnect the plug of the machine from the mains socket and wait approx. 2 minutes (capacitor charge) before removing the cover plate. Check at least every half year: Electric connectors of the machine clean the oxidised parts and tighten the loosened ones. Note! You must know correction tension torques before starting the reparation of the joints. Clean the inner parts of the machine from dust and dirt e.g. with a soft brush and vacuum cleaner. Also clean the ventilation net behind the front grate. Do not use compressed air, there is a risk that dirt is packed even more tightly into gaps of cooling profiles. Do not use pressure washing device. Only authorised electrician shall carry out repairs to the machines. 5.3 Regular maintenance Kemppi Service Workshops make regular maintenance according to agreement. The major points in the maintenance procedure are listed as follows: Cleaning of the machine Checking and maintenance of the welding tools Checking of connectors, switches and potentiometers Checking of electric connections Checking of mains cable and plug Damaged parts or parts in bad connection are replaced by new ones Maintenance testing. Operation and performance values of the machine are checked, and adjusted when necessary by means of test equipment. 8 FastMig KMS 400 MVU
11 6. Operation disturbances In the event of a failure of the machine, contact an authorised Kemppi service agent or your local Kemppi dealer. Check the maintenance objects before the machine is sent to the Service Workshop. 6.1 Operation of the overload protection Yellow pilot lamp H12 of thermal protection is lit when thermostat has operated due to overheating of machine. The thermostat of machine will operate, if machine is continuously loaded over rated values or cooling air circulation is blocked. Cooling fan cools down the machine and when the pilot lamp is not lit the machine is automatically ready for welding. 6.2 Control fuses Fuse F11, 6,3 A delayed, on the rear wall of machine is as protection for connection of auxiliary devices X Note! Use same type and rating of fuse which is marked beside the fuse adapter. Damage caused by a wrong type fuse is not covered by the guarantee. 6.3 Under- and overvoltages in the mains supply Primary circuits of machine are protected against sudden, transient overvoltages. Machine is designed to withstand 3 x 440 V voltage continuously (see technical data). See to it that voltage is kept within admissible limits especially when mains supply is taken e.g. from combustion engine generator. If the mains has undervoltage (under approx. 300 V) or overvoltage (over approx. 480 V) machine control stops to operate automatically. 6.4 Loss of a phase in the mains supply Loss of a phase causes noticeable poorer welding properties than normally or the machine doesn t get started at all. Loss of a phase can be due to following: blowing of mains supply fuse defective mains cable bad connection of mains connection cable on terminal block or plug of machine 7. Disposal of the machine Do not dispose of electrical equipment with normal waste! In observance of European Directive 2002/96/EC on waste electrical and electronic equipment, and its implementation in accordance with national law, electrical equipment that has reached the end of its life must be collected separately and taken to an appropriate environmentally responsible recycling facility. The owner of the equipment is obliged to deliver a decommissioned unit to a regional collection centre, per the instructions of local authorities or a Kemppi representative. By applying this European Directive you will improve the environment and human health. Kemppi Oy /
12 8. Ordering numbers FastMig KMS 400 MVU Wire feeders MXF EL MXF EL MXF EL MXF MXF MXF MSF MSF MSF Panels for wire feeders SF SF 52W W SF 53W W SF Accessories Return current cable 5 m, 50 mm² Return current cable 5 m, 70 mm² Cable for MMA welding 5 m, 50 mm² Cable for MMA welding 5 m, 70 mm² R Remote controlled interconnecting cable 10 m Cooling unit FastCool Transport unit PM Gun holder GH FastMig KMS 400 MVU
13 9. Technical data FastMig KMS 400 MVU 400 V 230 V Connection voltage 3~, 50/60 Hz 400 V -15 % % 230 V -10 % % Rated power 19 kva 20 kva Primary current MIG, 80%ED I 1max 27A 48A MIG, 100%ED I 1 26A 45A MMA, 80%ED I 1max 29A 50A MMA, 100%ED I 1 27A 47A Connection cable H07RN-F 4G6 (5 m) 4G6 (5 m) Fuse (delayed) 35 A 35 A Duty cycle 40 C 80 % ED 400 A/36 V 400 A/36 V 100 % ED 380 A/35 V 380 A/35 V Welding range MIG 10 V V 10 V V Max. welding voltage 46 V 46 V Open circuit voltage MIG V V MMA 50 V 50 V Idle power 25 W 25 W Efficiency at max. current 87 % 87 % Power factor at max. current Operating temperature range ºC ºC Storage temperature range ºC ºC Degree of protection IP23S IP23S EMC class A A Minimun short circuit power Ssc of 4.7 MVA 4.7 MVA supply network* External dimensions length 590 mm 590 mm width 230 mm 230 mm height 580 mm 580 mm Weight 49 kg 49 kg Operating voltage 400 V -15 % % 400 V -15 % % (for cooling unit) * See paragraph 3.2. Kemppi Oy /
14
15
16 KEMPPI OY Kempinkatu 1 PL 13 FI LAHTI FINLAND Tel Telefax [email protected] Kotimaan myynti: Tel Telefax [email protected] KEMPPI SVERIGE AB Box 717 S UPPLANDS VÄSBY SVERIGE Tel Telefax [email protected] KEMPPI NORGE A/S Postboks 2151, Postterminalen N-3103 TØNSBERG NORGE Tel Telefax [email protected] KEMPPI DANMARK A/S Literbuen 11 DK-2740 SKOVLUNDE DANMARK Tel Telefax [email protected] KEMPPI BELUX B.V. Postbus 5603 NL-4801 EA BREDA NEDERLAND Tel Telefax [email protected] KEMPPI (UK) Ltd Martti Kemppi Building Fraser Road Priory Business Park BEDFORD, MK44 3WH UNITED KINGDOM Tel +44 (0) Telefax +44 (0) [email protected] KEMPPI FRANCE S.A.S. 65 Avenue de la Couronne des Prés EPONE CEDEX FRANCE Tel Telefax [email protected] KEMPPI GmbH Perchstetten 10 D LANGGÖNS DEUTSCHLAND Tel Telefax [email protected] KEMPPI SPÓŁKA Z O.O. Ul. Borzymowska WARSZAWA POLAND Tel Telefax [email protected] KEMPPI AUSTRALIA PTY LTD. 13 Cullen Place P.O. Box 5256, Greystanes NSW 2145 SMITHFIELD NSW 2164 AUSTRALIA Tel Telefax [email protected] OOO KEMPPI Polkovaya str. 1, Building MOSCOW RUSSIA Tel Telefax [email protected] ООО КЕМППИ ул. Полковая 1, строение Москва Tel Telefax [email protected] KEMPPI, TRADING (BEIJING) COMPANY, LIMITED Room 420, 3 Zone, Building B, No.12 Hongda North Street, Beijing Economic Development Zone, Beijing CHINA Tel Telefax [email protected] 肯 倍 贸 易 ( 北 京 ) 有 限 公 司 中 国 北 京 经 济 技 术 开 发 区 宏 达 北 路 12 号 创 新 大 厦 B 座 三 区 420 室 (100176) 电 话 : 传 真 : [email protected] KEMPPI INDIA PVT LTD LAKSHMI TOWERS New No. 2/770, First Main Road, Kazura Garden, Neelankarai, CHNAI TAMIL NADU Tel Telefax [email protected]
MinarcMig Adaptive 170
MinarcMig Adaptive 170 Operating manual English Käyttöohje Suomi Bruksanvisning Svenska Bruksanvisning Norsk Brugsanvisning Dansk Gebrauchsanweisung Deutsch Gebruiksaanwijzing Nederlands Manuel d utilisation
Kempact MIG 2530 EN FI SV NO DA DE NL FR ES PL RU ZH PT IT. Operating manual. Käyttöohje. Bruksanvisning. Bruksanvisning.
Kempact MIG 2530 Operating manual Käyttöohje Bruksanvisning Bruksanvisning Brugsanvisning Gebrauchsanweisung Gebruiksaanwijzing Manuel d utilisation Manual de instrucciones Instrukcja obsługi Инструкции
MinarcMig. Evo 170, 200 EN FI SV NO DA DE NL FR ES PL RU PT IT. Operating manual. Käyttöohje. Bruksanvisning. Bruksanvisning.
MinarcMig Evo 170, 200 Operating manual Käyttöohje Bruksanvisning Bruksanvisning Brugsanvisning Gebrauchsanweisung Gebruiksaanwijzing Manuel d utilisation Manual de instrucciones Instrukcja obsługi Инструкции
FastMig M A new breed of industrial workhorse
FastMig M A new breed of industrial workhorse Proven reliability from the top of the welding technology Top welding performance for industrial MIG/MAG welding. Welding machine with various configurations
Master MLS. MasterTig MLS. MasterCool 2500, 3500 3000, 4000 EN FI SV NO DA DE NL FR ES PL RU ZH PT IT. Operating manual English.
Master MLS 2500, 3500 MasterTig MLS 3000, 4000 MasterCool 10 Operating manual English Käyttöohje Suomi Bruksanvisning Svenska Bruksanvisning Norsk Brugsanvisning Dansk Gebrauchsanweisung Deutsch Gebruiksaanwijzing
Minarc Evo 150 EN FI SV NO DA DE NL FR ES PL RU PT IT. Operating manual English. Käyttöohje Suomi. Bruksanvisning Svenska. Bruksanvisning Norsk
Minarc Evo 150 Operating manual English Käyttöohje Suomi Bruksanvisning Svenska Bruksanvisning Norsk Brugsanvisning Dansk Gebrauchsanweisung Deutsch Gebruiksaanwijzing Nederlands Manuel d utilisation Français
FastMig KM 300, 400, 500 EN FI SV NO DA DE NL FR ES PL RU ZH PT IT. Operating manual. Käyttöohje. Bruksanvisning. Bruksanvisning.
FastMig KM 300, 400, 500 Operating manual Käyttöohje Bruksanvisning Bruksanvisning Brugsanvisning Gebrauchsanweisung Gebruiksaanwijzing Manuel d utilisation Manual de instrucciones Instrukcja obsługi Инструкции
Wise and Match software
Wise and Match software Operating manual English Käyttöohje Suomi Bruksanvisning Svenska Bruksanvisning Norsk Brugsanvisning Dansk Gebrauchsanweisung Deutsch Gebruiksaanwijzing Nederlands Manuel d utilisation
Kempoweld WIRE 400, 550
Kempoweld WIRE 400, 550 Operating manual English Käyttöohje Suomi Bruksanvisning Svenska Bruksanvisning Norsk Brugsanvisning Dansk Gebrauchsanweisung Deutsch Gebruiksaanwijzing Nederlands Manuel d utilisation
MinarcMig Adaptive 180
MinarcMig Adaptive 180 Operating manual English Käyttöohje Suomi Bruksanvisning Svenska Bruksanvisning Norsk Brugsanvisning Dansk Gebrauchsanweisung Deutsch Gebruiksaanwijzing Nederlands Manuel d utilisation
KEMPOMAT 1701, 2100. Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation français
Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation français 1921440E 0531 KEMPOMAT 1701, 2100 CONTENTS 1. PREFACE... 3 1.1. Introduction... 3 1.2.
Operation instructions
Käyttöohje Suomi Bruksanvisning Svenska Bruksanvisning Norsk Bruksanvisning Dansk Operation instructions English Gebrauchsanweisung Deutsch Gebruiksaanwijzing Nederlands Manuel d utilisation Français Manual
Kemppi Mastertig MLS 2500 and 3500. Welding Versatility for Professionals
Kemppi Mastertig MLS 2500 and 3500 Welding Versatility for Professionals Kemppi Mastertig MLS 2500 and 3500 Welding Versatility for Professionals The Mastertig MLS 2500 and 3500 offer outstanding TIG performance
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
UNI FLAME AUTOLIFT MIG/MMA/TIG. 165/190/220/250 Inverter Manual. 240 Volt. Standard MIG / MAG
UNI FLAME AUTOLIFT MIG/MMA/TIG 165/190/220/250 Inverter Manual 240 Volt Standard MIG / MAG UNI FLAME AUTOLIFT 2YEARS Warranty * Machine Model Description Part Number MIG/MM/TIG Inverter KUMJR165 / 190
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
Bubble King. User Manual
Bubble King User Manual TABLE OF CONTENTS 1. Before You Begin... 3 What Is Included... 3 Unpacking Instructions... 3 Claims... 3 Text Conventions... 3 Icons... 3 Document Information... 3 Product at a
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
V94 BULK TAPE DEGAUSSER
TECHNICAL MANUAL Operating and Maintenance Instructions for V94 BULK TAPE DEGAUSSER V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Document No. M000208 Production Standard ZZ 009 415 WARNING To help minimise
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
RE-3 : SOLID TOP RANGE RANGE TOP ONLY
VULCAN ELECTRIC SOlid top oven range MODEL: RE-3 - SOLID TOP oven Range RE-3T - SOLID range top only ON CABINET BASE RE-3 : SOLID TOP RANGE Model Re-3T : Solid TOP RANGE TOP ONLY Index: General Data 2
2XWSXWFKDQQHOV 3KDVH &+ CH 2 &+ CH 4 &+ CH 6 L1 X X L2 X X L3 X X
INSTALLATION INSTRUCTIONS ENGLISH Version 1 1 January 2004 EUROLIGHT LD6230 IMPORTANT SAFETY INSTRUCTIONS DETAILED SAFETY INSTRUCTIONS: 1) Read these instructions 2) Keep these instructions 3) Heed all
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
6x 54w SuperZoo T5 HIGH FREQUENCY ELECTRONIC CONTROLLER LUMINAIRE
1 SAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR: ASZ01, ASZ02, ASZ03, ASZ04 6x 54w SuperZoo T5 HIGH FREQUENCY ELECTRONIC CONTROLLER LUMINAIRE Unit Weight: 8.5 Kg Dimensions: L1440*W400*H80mm Power
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
VLT Series 300 Watt True Sine Wave Inverter
VLT Series 300 Watt True Sine Wave Inverter PURE SINE WAVE INVERTER I ON 0 OFF REMOTE CONTROL AC OUTPUT POWER STATUS Vout Vin Models VLT12-300 VLT24-300 300 Watt VLT Series Inverter - 1 - TABLE OF CONTENTS
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
ORLAND FOLLOW PR-1211
ORLAND FOLLOW PR-1211 This product manual contains important information about the safe installation and use of this projector. Please read and follow these instructions carefully and keep this manual
Contact Details. Please note that some of the contact details on this PDF document may not be current.
Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: [email protected]
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 4000 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
Plug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
BeoLab 7-1 BeoLab 7-2. Guide
BeoLab 7-1 BeoLab 7-2 Guide CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified service personnel. WARNING: To prevent
1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
OPERATING INSTRUCTIONS
GB OPERATING INSTRUCTIONS Automatic Wedge Welding Machine Please read operating instructions carefully before use and keep for further reference. APPLICATION The is an automatic wedge welding machine for
3000W Power Inverter
3000W Power Inverter OWNER S MANUAL Model number-4573000 TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. White series
C88-VW-B UG [Update 10.05.12]_User guide 10/05/2012 09:40 Page 1 User Guide Vax Careline: (UK) 0844 412 8455 Bagless Cylinder White Get Cleaning... What s your Vax model number? (Located on the top flap
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
SPOT WELDER OPERATING & MAINTENANCE INSTRUCTIONS. Models CSW6T & CSW13T. Part Nos. 6030005 & 60300010 0204
SPOT WELDER Models CSW6T & CSW13T Part Nos. 6030005 & 60300010 0204 OPERATING & MAINTENANCE INSTRUCTIONS Copyright Clarke International. All rights reserved. October, 2001 2 Thank you for purchasing this
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415
Operation Instructions KleeBlower Compressor/Vacuum pumps Models: KB129 KB8415 Brd. Klee A/S All rights reserved Edition 01/2012 Head office: Branch office: Brd. Klee A/S Klee Engineering Ltd Gadagervej
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these
instabus KNX / EIB System System E F G H
Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
COOL Shelf Quick Connect
Refrigeration equipment Shelf lighting High efficiency COOL QCS Quick-Connection-System Dimmable Various lengths Neutral White Warm White Pasta & Cheese Fresh Meat Packed Meat 1 A COOL Shelf Quick Connect
Heading for the future
Heading for the future Satellite Multiswitch Instructions for Use MS 9/4 PIU-5 MS 9/6 PIU-5 MS 9/8 PIU-5 MS 9/10 PIU-5 MS 9/12 PIU-6 MS 9/16 PIU-6 MS 9/20 PIU-6 MS 9/26 PIU-6 EMP-Centauri is a registered
FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat
FREEZE Freezer equipment Canopy lighting High efficiency QCS Quick-Connection-System Dimmable Various lengths Daylight Neutral White Fresh Meat Packed Meat 1 A FREEZE Canopy PRODUCT DESCRIPTION 19.8 mm
Light Source User Guide
Light Source User Guide Compact DMX Light Source Models covered by this manual: UFO 150 CDMXG Glass, DMX - 240V UFO 150 CDMXP Plastic, DMX - 240V Universal Fibre Optics Issue 2 Revised: 23092013 Universal
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
BeoLab 1. User s guide
BeoLab 1 User s guide Legal notice: CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing
Electrical Resistance Resistance (R)
Electrical Resistance Resistance (R) Any device in a circuit which converts electrical energy into some other form impedes the current. The device which converts electrical energy to heat energy is termed
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.
BeoLab 11 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
How To Make A Fronius Cl Power Inverter
Fronius CL PV central inverter with Fronius MIX concept Modular system. Maximum yield. The Fronius CL combines high-yield power electronics with the unique, modular system design of up to 15 identical
SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9
CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY
Installation Guide. DEVIreg 530. Electronic Thermostat. www.devi.com
Installation Guide DEVIreg 530 Electronic Thermostat www.devi.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive
victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850
victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850 SECTIONS ENGLISH 1 NEDERLANDS 27 DEUTSCH 55 This page intentionally left blank. ENGLISH USER MANUAL Victron Atlas
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
FLEXIT S4 R S6 R S7 R
94111E-05 2005-10 FLEXIT S4 R S6 R S7 R User Manual Air Handling Unit Cabinet Models with Heat Recovery - Rotor Contents 1 Important Safety Instructions... 3 2 Method of Operation - System... 3 2.1 Heating
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
SVENSKA.......................................................3 DANSK.........................................................10 NORSK................
Caddy 150 & Caddy Tig 150 LHQ 150, LTV 150 SVENSKA.......................................................3 DANSK.........................................................10 NORSK.........................................................17
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI Page 2 / 16 CONTENTS 1 GENERAL... 3 2 SAFETY... 3 2.1 Safety instructions... 3 2.2 Correct use... 3 3 DESCRIPTION
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 8-0 Fax +49 (0) 7938 8-0 [email protected] www.ebmpapst.com CONTENTS. SAFETY REGULATIONS AND NOTES. Levels of hazard
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the
Operations Manual Blast Chiller
Operations Manual Blast Chiller ADE- 2039-A Page 1 of 14 Contents Page 1 What is the Adande System 3 2 Adande Technology Explained 3 3 EC Declaration of Conformity 4 4 Storage of Product 5 5 Operating
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS 98-5013
Sid/Page 1 SESOBS THE SMOKE DENSITY MONITOR - Easy and safe to operate and install - Complete with sealing air fans. - Remote smoke density indication possible. - Designed to meet with the environmental
Power transformers. Special transformers Railway
Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together
MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel
MANUAL CONGRATULATIONS on the purchase of your new CTEK professional battery management unit. This unit is part of a range of professional battery chargers from CTEK SWEDEN AB. It represents the latest
User manual. Videomatic VERDE MF
User manual Videomatic VERDE MF EN Contents Product information.......................................... 6 I. General information....................................... 6 Notes on the electromagnetic
1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.
MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
M Zero. Owner's Information. Music's Finest Conductor. Level 0 line pre-amplifier
M Zero Level 0 line pre-amplifier Owner's Information Music's Finest Conductor Introduction to the M Zero pre-amplifier Congratulations on your purchase of the Audio Note M Zero level 0 pre-amplifier.
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
