Room Temperature Sensors

Similar documents
Room Temperature Sensors

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Flush-mount room temperature sensor AQR2531ANW.

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Digital input modules

Air damper actuators

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Flush-mounted room thermostats

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RRV934. Multi-controller. Synco living

Heating Controller. Building Technologies HVAC Products

TX OPEN RS232/485 module

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Duct Humidity Transmitter

Drayton Digistat +2RF/+3RF

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

OZS Web server. For LPB/BSB plants

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

OZW30. Central Unit SYNERGYR

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ACS-30-EU-EMDR-10-MOD

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

PCS0100en Persy Control Services B.V. Netherlands

Electronic Control Devices The European Product Catalogue 2007

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

T0118 T2118 T3118. Instruction Manual

Input module, input/output module

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Product and Application Description

J TB/TW Temperature limiter, temperature monitor

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

HMI display Installation Guide

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Electronic Control Devices The European Product Catalogue 2007

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Adjustable room thermostat for heating only or cooling only systems

How To Read A Pipe From A Sensor

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

OZW V2.0. Web server. Synco TM, Synco TM living

Three-phase monitoring relay CM-PFE

Product and functional description

Material test chamber with mechanical convection

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

DS 600. A contact free flux gate based current measurement sensor 600A rms

Actuator-Sensor-Interface

Safety technique. Emergency stop module BO 5988 safemaster

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

aseries A13B Mini Bullet Camera User Manual

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

AXIS T81B22 DC 30W Midspan

Incubator with mechanical convection

OZW672...V5.2. Web-Server. For LPB/BSB plants

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Technical Data. Dimensions

HERZ-Thermal Actuators

Installation, operation and maintenance manual TX 35A

Radiant Temperature Sensor TY7321

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Digital inductive conductivity transmitter

Mureva Assembly surface mounted wiring devices

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

MOUNTING AND OPERATING INSTRUCTIONS

Infrarot-Bewegungsmelder IP44

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Rousseau 10. User Guide

Electronic overload relay EF19 and EF45

Preset Counter signo 721

Redundancy Module QUINT-DIODE/40

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Electronic overload relay EF65, EF96 and EF146

SINEAX U553 Transducer for AC Voltage

=============================== WARNING

is then retained absolutely without interruption.

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltech DC1000. Precision DC Bias Current Source

5SV Residual Current Protective Devices

GREISINGER electronic GmbH

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

EBS852 (Contrac) Power Electronic Unit

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Floodlight Range Installation Guide

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

RM4TG20 three-phase network control relay RM4-T - range V

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Transcription:

1 749 1749P01 QAA20..1 Symaro Room Temperature Sensors QAA20..1.. Active sensors for acquiring the room temperature Operating voltage AC 24 V or DC 13.5 35 V Signal output DC 0...10 V or 4...20 ma Use In heating, ventilation and air conditioning plants for acquiring the room temperature. Type summary Type reference QAA2061 Measuring range Operating voltage Output signal 0...50 C AC 24 V ±20 % / DC 13.5...35 V SELV or class 2 (US) QAA2071 0...50 C DC 13.5 35 V SELV or class 2 (US) DC 0 10 V 4...20 ma Ordering and delivery When ordering, please give name and type reference, e.g.: Room temperature sensor QAA2061. Equipment combinations All systems or devices capable of acquiring and handling the sensor s DC 0 10 V or 4 20 ma output signal. CE1N1749en 2014-07-30 Building Technologies

Function The sensor acquires the room temperature via its sensing element whose resistance value changes as a function of the temperature. This change is converted to a DC 0...10 V or 4...20 ma output signal, depending on the type of sensor. The output signal corresponds to the selected temperature range. Burden diagram Output signal, terminal I1 Burden [Ohm] 900 800 700 600 500 400 300 Inadmissible range! Admissible range 1749D02en 200 100 0 0 10 20 30 40 Operating voltage [DC V] Mechanical design QAA20..1 The units have been designed for wall mounting. They are suitable for use with most commercially available recessed conduit boxes. The cables can be introduced from the rear (concealed wiring) or from below or above (surface-run wires) through knock-out openings. The units consist of two major sections: Casing and baseplate. Both snap together but can be detached again. The measuring circuit, the sensing element and the setting element are located on the printed circuit board inside the casing. The baseplate carries the connecting terminals. Mechanical design is similar to QAA20.1.. with additional LC-Display. Display of room temperature in C or F Setting element Test function active U1 I1 F C Measuring range R1 R2 R3 5 V 0 V 12 ma 4 ma R1 R2 R3 Display of room temperature F 5 V 12 ma 1 3 C 2 4 10 V 20 ma 1749Z01en The setting element is accessible after removing the baseplate. It consists of 6 pins and a shorting plug. It is used to select the required measuring range and to activate the test function. The different plug positions have the following meaning For the active temperature measuring range: Shorting plug in the upper position (R1) = 35...+35 C, 2/6

Shorting plug in the mid position (R2) = 0...50 C (factory setting) Shorting plug in the lower position (R3) = 50...+50 C For activating the test function: Shorting plug in the vertical position: The values according to the table "Test function active" will be made available at the signal output. Fault In the event of fault, the output signal will reach 0 V (4 ma) after 60 seconds. Engineering notes Room sensors with active outputs have a high power loss, which ultimately influences temperature measurement. The degree of influence depends on the operating voltage and is compensated in the Symaro TM room sensors for an operating voltage of AC 24 V or DC 24 V. Over- or undercompensation may occur for other operating voltages. Furthermore, the measuring accuracy is impacted by the following factors: - Prevailing air flow - Wall surface (rough, smooth) - Wall texture (wood, plaster, concrete, brick) - Wall type (interior, exterior). This application-specific measuring inaccuracy is constant for an installed sensor after approx. 1 operating hour, and it can be adjusted as needed in a higher system (e.g. controller). No correction on the local LCD. To power the sensor, a transformer for safety extra low-voltage (SELV) with separate windings for 100 % duty is required. When sizing and electrically protecting the transformer, local safety regulations must be observed. When sizing the transformer, the power consumption of the room temperature sensor must be taken into consideration. For correct wiring, refer to the Data Sheets of the devices with which the sensor is used. The permissible cable lengths must be observed. Cable routing and cable selection When laying the cables, it must be observed that the longer the cables run side by side and the smaller the distance between them, the greater the electrical interference. Twisted pair cables are required for the secondary supply lines and the signal lines. Mounting notes Location Installation instructions On an inner wall of the space to be heated or air conditioned. Not in recesses, shelves, not behind curtains, not above or near heat sources. The unit must not be exposed to direct solar radiation. The end of the conduit at the sensor must be sealed to prevent false measurements due to draughts through the conduit. The permissible ambient conditions should be observed. Installation instructions are printed inside of the packing. Commissioning notes Check wiring before switching on power. The temperature measuring range must be selected on the sensor, if required. 3/6

Disposal The devices are considered electronics devices for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic waste. Dispose of the device via the channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Technical data Power supply Line lengths for measuring signal Functional data Degree of protection Electrical connections Environmental conditions Operating voltage Frequency Power consumption QAA2061, QAA2071 External supply line protection (EU) Perm. cable lengths Copper cable 0.6 mm dia. Copper cable 1 mm 2 Copper cable 1.5 mm 2 Measuring range refer to "Type summary" 50/60 Hz at AC 24 V 0.3VA 0.7W Fuse slow max. 10 A or Circuit breaker max. 13 A Characteristic B, C, D according to EN 60898 or Power source with current limitation of max. 10 A 50 m 150 m 300 m Sensing element Pt 1000 Time constant Measuring accuracy at AC 24 V / DC 24V in the range of: 23 C 25...+25 C 50...+50 C 0...50 C (R2 = factory setting), 35...+35 C (R1), 50...+50 C (R3) approx. 7 min ±0.50 K ±0.75 K ±0.9 K Output signal, linear (terminal U1) DC 0 10 V 0 50 C or 35...+35 C or 50...+50 C max. ±1 ma Output signal, linear (terminal I1) Burden 4 20 ma 0 50 C or 35...+35 C or 50...+50 C refer to Function Protection class III according to EN 60730-1 Protection degree of housing IP30 according to EN 60529 Connection terminals for 1 2.5 mm 2 or 2 1.5 mm 2 Operation Climatic conditions Temperature (housing with electronics) Humidity Mechanical conditions Transport Climatic conditions Temperature Humidity Mechanical conditions IEC 60721-3-3 class 3K5 15...+50 C 0 95 % r. h. (non-condensing) class 3M2 IEC 60721-3-2 class 2K3 25...+70 C <95 % r. h. class 2M2 4/6

Materials and colors Directives and Standards Environmental compatibility Weight Housing front Bottom Base Packaging Sensor (complete assembly) ASA+PC, NCS S 0502-G (white) equates to RAL9010 ASA+PC, NCS 2801-Y43R (grey) equates to RAL 7035 PC, NCS 2801-Y43R (grey) equates to RAL 7035 corrugated cardboard silicone-free Product standard EN 60730-1 Electromagnetic compatibility (Applications) EU Conformity (CE) CE1T1749xx *) Automatic electrical controls for household and similar use RCM Conformity 8000078879_en *) For use in residential, commerce, light-industrial and industrial environments UL UL 873, http://ul.com/database The product environmental declaration CE1E1961 *) contains data on environmentally compatible product design and assessment (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Incl. packaging Without LCD display With LCD display 0.13 kg Approx. 0.130 kg Approx. 0,150 kg *) The documents can be downloaded from http://siemens.com/bt/download. 5/6

Connection terminals QAA2061 G G0 U1 1749G01... QAA2071 G1 I1 1749G02 G, G0 Operating voltage AC 24 V (SELV) or DC 13.5...35 V G1 Operating voltage DC 13.5...35 V I1 Signal output 4...20 ma for temperature range (R2 = 0...50 C, factory setting) U1 Signal output DC 0...10 V for temperature range (R2 = 0...50 C, factory setting) Dimensions 4,2 9,5 100 56 60 90 36 56 60 1749M01 Drilling plan Dimensions in mm 6/6 2006-2014 Siemens Switzerland Ltd. Subject to change