Zero Waste Retrofit Kit Instruction

Similar documents
INSTANT HOT WATER RECIRCULATING SYSTEM

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

INSTALLATION INSTRUCTIONS. SharkBite. Connection System. The SharkBite System

Watts Pure Water Systems

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

SAVARD PLUMBING COMPANY

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Installation, Maintenance, & Repair Series 4000B/LF4000B

How To Replace A Reverse Osmosis Water Tank

Installation and Maintenance Instructions

VOYAGER 570G. 744A Sprayer Control

Installation Instructions

RPlus. Installation & Service Manual. 5-Stage Reverse Osmosis Drinking Water System. Plus

*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide

PURE WATER. Installation, Operation and Maintenance Manual. Kwik-Change Reverse Osmosis System Model PWROKC4. Important.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Installation and Operation Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Ice Maker. User Manual HI6LMK. Haier America New York, NY Haier America Trading, LLC.

Simply complete the enclosed Warranty Form with contact details, or us with your details and date of purchase.

What you can expect from your Solar Hot Water System

Line to Refrigerator Ice/Water Dispenser

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Electric Water Heater

INSTALLATION GUIDE. APPLICATION LENGTH MODEL YR PART # Bestop PART #

cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.

MODEL G300 BRAKE BLEEDER

PAINT SPRAY GUN WASHER

Installation Instructions

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Universal Wireless Effects Controller USER S GUIDE SA115

MAC FAUCETS. Owner s Manual. Models: FA444

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

Geyser-R Heat pump water heater Installation manual

4 in 1 Air Compressor

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Installation Instructions S

Bottom Loading Water Dispenser

Model 5600SE Downflow

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Installation Instructions / Warranty

hello. welcome to smart watering.

Your safety and the safety of others are very important.

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

MP-4V Heavy Duty Riveter / 39048

MODEL # Introduction

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation and Maintenance Instructions

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

55-Gallon Dispenser Package

INSTALLATION & SERVICE MANUAL

Southwest Florida Water Management District. Fix It for Less

ECM-D70T / ECM-D70T1.5

Customer Support

4 Stage Barracuda RO/DI Instruction & Owner s Manual

Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

2470 RO120 QUICK CONNECT

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

Installation Instructions

Installation and Maintenance Instructions

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Installation Instructions

Miami Heat Pump HP Series Installation Guide

Thank you... Welcome to your new world of better living with water2buy s Aquasmart Reverse Osmosis water. How your Reverse Osmosis unit works

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

Utility Distribution Systems

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

Retractable Screen. Replacement Screen Instructions

A High Bill Usually Means a Leak

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

tire inflator with pressure gauge

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

INSTALLATION & SERVICE MANUAL

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

Installation Instructions

O W N E R S M A N U A L SERIAL NUMBER

Hydraulic Punch Driver Kit

8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P B E B B B-24267

Part Name/Description Part Number Quantity. Power Cable

Wanda Technology Inc. Side Post Aluminum Umbrella OWNER S MANUAL

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER DS BMW 335i 3.0L

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Transcription:

Zero Waste Retrofit Kit Instruction B CHECK C FLOW RESTRICR FOR 25-35 GPD (500ML - GREEN INSERT) O WIRE HARNESS A BLACK TUBE D FLOW RESTRICR FOR 50 GPD (700ML- PURPLE INSERT) P GREEN TUBE F F J I J E SELENOID PRESSURE SWITCH L DRAIN SADDLE PLUG H TRANSFORMER G BOOSTER PUMP M ELBOW N NUT K ADAPT-A- NOTE: UNIT IS NOT INTENDED FOR USE WITH TANKLESS WATER HEATERS Introduction Thank you for buying the Zero Waste Retrofit Kit. This kit is designed to retrofit existing reverse osmosis systems and save water from being wasted. How it works: This conversion kit works by using the booster pump to increase the pressure throughout the system so that the brine water (which is usually wasted) can be recycled back into the hot water line. Here is what each component does: Booster Pump: Boosts the pressure throughout the system. Solenoid: Shuts off the water to the unit when the tank is full. Pressure Switch: Turns off the pump and closes the solenoid when the tank is full. Check Valve: A one-way valve that allows the brine (waste) water to get pushed into the hot water, but not let any hot water back in. Flow Restrictor: Controls how much water is returned into the hot water line. See instructions for sizing. Transformer: Provides power to the electrical components. Package Contents: LABEL PART# DESCRIPTION QTY A 610117 BLACK TUBE 1 B 610019 DOUBLE-CHECK 1 C 622055 500 ml FLOW RESTRICR (GREEN INSERT) 1 D 622054 700 ml FLOW RESTRICR (PURPLE INSERT) 1 E 152035 SOLENOID 1 F 125088 1/4" QC x 1/8" MPT ELBOW FITTING 2 G 152008 BOOSTER PUMP 1 H 252004 TRANSFORMER 1 I 152030 PRESSURE SWITCH 1 J 228048 1/4" QC x 3/8" STEM FITTING 2 K 560080 ADAPT-A- w/ BRASS ADAPTERS & WASHER 1 L 228073 DRAIN SADDLE PLUG 1 M 125089 1/4" STEM x 1/4" QC ELBOW 1 N 125002 COMPRESSION NUT FOR 1/4" FITTING 3 O 152044 WIRE HARNESS 1 P 610109 GREEN TUBE 1

How To Use the Quick Connect Fittings To make a connection, the tube is simply pushed in by hand; the unique patented John Guest collet locking system then holds the tube firmly in place without deforming it or restricting flow. Cut the Tube Square Push Up to the Tube Stop Cut the tube square and remove burrs and sharp edges. Ensure that the outside diameter is free from score marks. Push the tube into the fitting and up to the tube stop Instructions: PLEASE NOTE installation may vary depending on your system, please review the attached diagrams for your unit. If your unit is not shown, please contact customer service at 800-752-5582. Preparation Step 1 - Turn off the hot and cold water angle stops Step 2 - Lift the handle on the reverse osmosis faucet to drain the water from the system and storage tank. Note: If the tank is equipped with a ball valve, close the valve to preserve tank water Adapt-a-valve Installation at Hot-Water Angle Stop Connect the adapt-a-valve as shown below Pull to Check Secure Pull on the tube to check that it is secure. Test the system before use EXISTING LINE FAUCET To Disconnect Push in collet and remove tube BRASS ADAPTER To disconnect, ensure that the system is depressurized, push the collet square against the fitting. With the collet held in this position the tube can be removed. PLASTIC ADAPT-A- & COLLET Tools Needed 5/8" Open-ended wrench or adjustable wrench Knife or Scissors Phillips screwdriver / screw gun Channel Lock Checklist Reverse osmosis system must be at least 25 feet (piping distance) from the hot water heater For proper performance and pump life, make sure you are up to date with your filters and please verify the pressure of the storage tank (as recommended by your operating manual) Reverse osmosis system must use a single 25-50 GPD membrane A non-switched outlet BRASS ADAPTER WHITE WASHER EXISTING HOT-WATER ANGLE SP DO NOT USE ANY TEFLON TAPE AT CONNECTIONS

Alternate Adapt-a-valve installation at Hot Water Connection to Faucet If you are connecting the adapt-a-valve at the faucet connection, install as shown below: EXISTING FAUCET CONNECTION Step 11 - All electrical connections are color coded for your convenience. Plug the wire harness into the pump and solenoid. Step 12 - Connect the pressure switch to the wire harness Step 13 - Connect the transformer to the pressure switch Startup Step 14 - Turn on the hot and cold water supply valves and check for leaks Step 15 - Plug the transformer into the electrical outlet and let the unit run for two minutes and check for leaks. Step 16 - Open the RO faucet and make sure water begins to trickle out within 10 minutes. If it does not, check your connections and the direction of flow through the pump Step 17 - Periodically check the unit for leaks during the first fivedays of operation. PLASTIC ADAPT-A- & COLLET EXISTING LINE HOT-WATER ANGLE SP DO NOT USE ANY TEFLON TAPE AT CONNECTIONS Brine Connection Step 3 - Disconnect the existing brine tube from the membrane. Make sure to also remove the existing flow restrictor from the unit. The existing brine tube will no longer be used. NOTE: Part of this upgrade will include switching your existing flow restrictor with one provided with this kit. Please see sizing chart below: MEMBRANE FLOW RESTRICR 25 GPD MEMBRANE 500 ML FLOW RESTRICR (RED TUBE WITH GREEN INSERT) 35 GPD MEMBRANE 500 ML FLOW RESTRICR (RED TUBE WITH GREEN INSERT) 50 GPD MEMBRANE 700 ML FLOW RESTRICR (RED TUBE WITH PURPLE INSERT) Step 4 - Determine which flow restrictor to use based on the table above Step 5 - Connect the open end of the red flow restrictor tube to the check valve - make sure the tube is inserted 0.75 inches into the check valve Step 6 - Connect the red tube with the flow restrictor insert into the brine port of the unit Step 7 - Connect the black tube from the new check valve/flow restrictor assembly to the hot water adapt-a-valve Step 8 - Disconnect the tube to the drain saddle. This drain tube will no longer be used Step 9 - Insert the plug into the drain saddle. Connection to Unit Step 10 - Choose the correct configuration on the following pages for your specific unit

POST- FILTER PLUG DRAIN SADDLE 5 TANK TANK (BLUE) PRESSURE SWITCH RO MEMBRANE 1 3 BRINE (RED) CHECK TRANSFORMER SRAGE TANK WIRE HARNESS SELENOID 2 SEDIMENT PRE-FILTER PRE-FILTER THIRD FILTER BOWL ON FIVE-STAGE ONLY PRE-FILTER PUMP ADAPT-A- HOT-WATER 4 COLD-WATER ADAPT-A- BRINE (BLACK) Five-Stage Standard Unit Connection Steps Step 1 - Remove the existing Automatic Shut-off Valve Step 2 - Install the Booster Pump and Solenoid between the third stage filter canister and the cap of the reverse osmosis membrane (if needed, use provided green tube) Step 3 - Connect the red flow restrictor tube into the brine elbow Step 4 - Connect the open end of the black hose into the adapt-a-valve connected to the hot water shut-off Step 5 - Splice the pressure switch on the line leading to the tank

FAUCET (BLUE) 3 BLUE TUBE - FAUCET 4 TANK (BLUE) BRINE (RED) BRINE (WASTE) PORT POST RO PRE- SEDIMENT FAUCET REAR VIEW OF FILTER MODULE TRANSFORMER TANK TANK (BLUE) PRESSURE SWITCH 6 CHECK BRINE (RED) TANK (BLUE) 1 FILTER MODULE FAUCET (BLUE) WIRE HARNESS SRAGE TANK BRINE (BLACK) SELENOID 2 PUMP 5 ADAPT-A- DRAIN SADDLE PLUG HOT-WATER COLD-WATER RO Pure/Plus Connection Steps Step 1 - Remove the existing Automatic Shut off Valve Step 2 - Install the Booster Pump and Solenoid between the cold water adapt-a-valve and the connection behind the red filter (if needed, use provided green tube) Step 3 - Install the provided elbow to the brine port on the filter module (please remove any existing elbows and/or flow restrictors) Step 4 - Connect the red flow restrictor tube into the brine elbow Step 5 - Connect the black tube into the hot water adapt-a-valve Step 6 - Splice the pressure switch on the line leading to the tank

Warranty LIMITED WARRANTY: Watts Premier warrants each product to be free from defects in material and workmanship for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge. This shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special or consequential damages, including, without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemicals, or any other circumstances over which the Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Any implied warranties that are imposed by law are limited in duration to one year. Some States do not allow limitations on how long an implied warranty lasts, and some States do not allowthe exclusion or limitation of incidental or consequential damages. Therefore, the above limitations may not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult applicable State laws to determine your rights. California Proposition 65 Warning WARNING: this product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. (Installer: California law requires that this warning be givento the consumer). For more information: www.wattsind.com/prop65.