Humidity and Temperature Wall Mount Transducers. SCT Series. Datasheet

Similar documents
HIH-4000 Series Humidity Sensors

humidity sensors Line Guide FEATURES Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH7000 Series, HIH8000 Series

Industrial VRS Magnetic Speed Sensors

FEATURES Temperature-compensated magnetics Miniature plastic package Low voltage: 3.8 V operation

Honeywell Pressure Switches Line Guide

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH8000 Series ±2.0 %RH Accuracy. Datasheet

CQM1-SF200/CS1W-SF200

Advantium 2 Plus Alarm

MICRO SWITCH Compact Precision Limit Switches. 14CE Series. Datasheet

MICRO SWITCH Compact Precision Limit Switches. 914CE Series. Datasheet

Fiber Optics and Liquid Level Sensors Line Guide

Model SRMD Setra Remote Monitoring Display

Capteur température et humidité pour HVAC

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

Temperature Humidity Meter

STRATO LED Drivers 70W, Single output

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Airflow Sensors Line Guide

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Model 43. Precision Low Profile Load Cell DESCRIPTION FEATURES

Contents. Document information

Speed Sensors Line Guide

T0118 T2118 T3118. Instruction Manual

Duct Humidity Transmitter

Heavy Duty Pressure Sensors/ Transducers Line Guide

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Electronic Control Devices The European Product Catalogue 2007

GREISINGER electronic GmbH

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

T5000 T000 LCD Digital Fan Coil Thermostat

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

How To Use A Cdm250 Digital Multimeter

Manual Ranging MultiMeter

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Temp. & humidity Transmitter Instructions

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Rosemount 333 HART Tri-Loop

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Operating Manual UWAPS-TINY Series

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

MICRO SWITCH Compact Precision Limit Switches. 914CE Series. Datasheet

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

Telephone- and leased line modem for industrial applications TD-36

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES

Electronic Control Devices The European Product Catalogue 2007

HMI display Installation Guide

Manual. Solar Fountain Mobile Phone Charger

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

700/732 SERIES. 5mm HOUR METERS & COUNTERS. CURTIS INSTRUMENTS, INC. 200 Kisco Avenue, Mt. Kisco, NY Tel. (914) FAX (914)

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Instruction Manual. T3111 T3111L T3111P T3111Ex

Original instructions Tina 3A/Aps Adaptor unit

Part I - Installation

Leak Detection System

ADM1TE 5/30A DIN rail single phase two wire energy meter

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

CompactLogix Power Supplies Specifications

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

, User s Manual

Tina 2A/B Adaptor unit

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Rosemount 333 HART Tri-Loop

IntesisBox KNX LG Air Conditioning

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

IntesisBox KNX - LON

TX OPEN RS232/485 module

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Duct Temperature Sensors

HTM2500LF Temperature and Relative Humidity Module

Humidity Sensor. Model HU-224/225

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

1 POLE - 8A Medium Load Control

Data Sheet PS1B Pressure Switch

Ultrasonic Distance Meter. Operation Manual

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications


Safety Manual BT50(T) Safety relay / Expansion relay

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Transcription:

Humidity and Temperature Wall Mount Transducers SCT Series Datasheet

Humidity and Temperature Wall Mount Transducers, SCT Series Honeywell Humidity and Temperature Wall Mount Transducers, SCT Series, are an ideal environmental solution for indoor applications such as building automation and HVC systems in residential and office buildings. The SCT Series utilizes Honeywell HumidIcon humidity/temperature sensors to accurately and reliably sense humidity and temperature in the area to enhance user comfort. The SCT Series offers a variety of options and features. The transducers can be equipped with or without a legible LCD display that shows the ambient temperature along with the relative humidity or dew point. The stylish cover trim is available in either silver or gold. Standard output of humidity and temperature is either 4 m to 20 m or 0 V to 0 V. The temperature output signal may also be configured with an NTC 0 kohm, 20 kohm or PT000 sensor. Features Enhanced accuracy: - ±4 %RH (0 %RH to 90 %RH at 25 C), ±5 %RH (0 %RH to 90 %RH at 5 C to 50 C) - Enables the customer to potentially reduce/eliminate transmitter recalibration cost and supports and optimizes system accuracy and uptime Long-term stability: - Humidity: ±0.05 %RH typ. and ±.2 %RH max. drift over five years - True temperature-compensated humidity element enables customers to potentially reduce/eliminate the transmitter recalibration cost with enhanced stability over next best alternatives Enhanced reliability: The humidity sensor element s multilayer construction provides resistance to most application hazards such as dust, dirt, condensation, oils and common environmental chemicals, enhancing reliability Standard humidity output: 4 m to 20 m or 0 V to 0 V Cost-effective Choice of cover trim color (silver or gold) Full 0 %RH to 00 %RH measurement range vailable with or without LCD display Potential pplications INDUSTRIL Climate monitoring and control for: Residential and office buildings Production and manufacturing plants Storerooms Equipment cabinets Testing environments 2 sensing.honeywell.com INDUSTRY-STNDRD CCURCY STBILITY RELIBILITY

SCT Series Table. Humidity and Temperature Performance Characteristic Condition Parameter Humidity measurement range - 0 % RH to 00 %RH non-condensation Humidity accuracy 25 C [77 F], 0 %RH to 90 %RH 5 C to 50 C [4 F to 22 F], 0 %RH to 90 %RH Temperature measurement range - Long term drift - Temperature accuracy: units with transducer units with NTC 0 kohm sensor units with NTC 20 kohm sensor units with Pt 000 Class sensor Refer to Figure 3 to set temperature measurement range. 25 C [77 F] 0 C to C [50 F to 86 F] -25 C to 0 C [-3 F to 50 F]; C to 70 C [86 F to 58 F] 25 C 25 C 25 C ±4 %RH ±5 %RH -5 C to 55 C [3 F to 3 F] or 0 C to 70 C [32 F to 58 F] or -25 C to 60 C [-3 F to 40 F] ±0.05 %RH typ. and ±.2 %RH max. at 50 %RH for 5 years stability ±0.3 C ±0.5 C ± C ±0.2 C, Beta 3892 ±0.2 C, Beta 3892 ±0.3 C, DIN IEC75 Class, 385 lpha Table 2. Electrical Specifications Characteristic : units with 4 m to 20 m output units with 0 V to 0 V output nalog output signal load resistance: units with 4 m to m output units with 0 V to 0 V output NS Table 3. Environmental Specifications N Characteristic Operating temperature range: units with LCD display units without LCD display Storage temperature range: units with LCD display units without LCD display Electromagnetic compliance: immunity emission Table 4. Mechanical Specifications Parameter 24 Vdc ±0%, 50 m max. 8 Vdc to 40 Vdc, 5 m max. or 24 Vac ±5%, 50/60 Hz, 50 m max. 500 Ohm max. 0 kohm min. Parameter -20 C to 70 C [-4 F to 58 F] -25 C to 85 C [-3 F to 85 F] - C to 80 C [-22 F to 76 F] -40 C to 85 C [-40 F to 85 F] EN6326- and EN6326-2-3 Industrial Electromagnetic Environment Class B equipment Characteristic Sealing Housing material Terminal block NS Parameter IP plastic (PC+BS) UL 94 V-0 (Standard for Tests for Flammability of Plastic Materials for Parts in Devices and ppliances) screw terminals, max. wire size is,5 mm 2 or WG6 sensing.honeywell.com 3

Humidity and Temperature Wall Mount Transducers Figure. Nomenclature Tree For example, SCTHW43SDS defines an SCT Series humidity and temperature transducer, wall mount, 4 m to 20 m output, 4 %RH humidity accuracy, 0.3 C temperature accuracy/output type, -5 C to 55 C temperature range, LCD display, silver cover trim. SCT H W 4 3 S D S Series Model Installation Output Humidity ccuracy Temperature ccuracy/output Temperature Range LCD Display Cover Trim Color SCT Series Humidity and Temperature Wall Mount Transducers H Humidity and temp. T Temperature W Wall mount B C D Humidity: 4 m to 20 m Temperature: 4 m to 20 m Humidity: 4 m to 20 m 4 4 %RH 3 0.3 C None, temperature NTC 0 kohm N E only F NTC 20 kohm Pt000 Class G S N -5 C to 55 C [23 F to 3 F] None, temperature passive D LCD display N No LCD display S Silver G Gold Not all catalog listing combinations are available. Custom products are available. Please contact Honeywell. E F Temperature: 4 m to 20 m Table 5. Order Guide for 4% Humidity ccuracy Catalog Listing Description SCTHW43SDS Humidity and temperature, wall mount, 4 m to 20 m, 4 %RH, 0.3 C, -5 C to 55 C, LCD display, silver SCTHW43SNS Humidity and temperature, wall mount, 4 m to 20 m, 4 %RH, 0.3 C, -5 C to 55 C, no LCD display, silver SCTHWB43SDS Humidity and temperature, wall mount, 0 V to 0 V, 4 %RH, 0.3 C, -5 C to 55 C, LCD display, silver SCTHWB43SNS Humidity and temperature, wall mount, 0 V to 0 V, 4 %RH, 0.3 C, -5 C to 55 C, no LCD display, silver SCTHWC4GNDS Humidity and temperature, wall mount, 4 m to 20 m, 4 %RH, Pt000 Class, LCD display, silver SCTHWC4GNNS Humidity and temperature, wall mount, 4 m to 20 m, 4 %RH, Pt000 Class, no LCD display, silver SCTHWC4FNNS Humidity and temperature, wall mount, 4 m to 20 m, 4 %RH, NTC 20 kohm, no LCD display, silver SCTHWC4FNDS Humidity and temperature, wall mount, 4 m to 20 m, 4 %RH, NTC 20 kohm, LCD display, silver SCTHWC4ENDS Humidity and temperature, wall mount, 4 m to 20 m, 4 %RH, NTC 0 kohm, LCD display, silver SCTHWC4ENNS Humidity and temperature, wall mount, 4 m to 20 m, 4 %RH, NTC 0 kohm, no LCD display, silver SCTHWD4GNDS Humidity and temperature, wall mount, 0 V to 0 V, 4 %RH, Pt000 Class, LCD display, silver SCTHWD4GNNS Humidity and temperature, wall mount, 0 V to 0 V, 4 %RH, Pt000 Class, no LCD display, silver SCTHWD4FNDS Humidity and temperature, wall mount, 0 V to 0 V, 4 %RH, NTC 20 kohm, LCD display, silver SCTHWD4FNNS Humidity and temperature, wall mount, 0 V to 0 V, 4 %RH, NTC 20 kohm, no LCD display, silver SCTHWD4ENDS Humidity and temperature, wall mount, 0 V to 0 V, 4 %RH, NTC 0 kohm, LCD display, silver SCTHWD4ENNS Humidity and temperature, wall mount, 0 V to 0 V, 4 %RH, NTC 0 kohm, no LCD display, silver Table 6. Order Guide for No Humidity (Temperature Only) ccuracy Catalog Listing Description SCTTWEN3SDS Temperature, 4 m to 20 m, 0.3 C, -5 C to 55 C, LCD display, silver SCTTWEN3SNS Temperature, 4 m to 20 m, 0.3 C, -5 C to 55 C, no LCD display, silver SCTTWFN3SDS Temperature, 0 V to 0 V, 0.3 C, -5 C to 55 C, LCD display, silver SCTTWFN3SNS Temperature, 0 V to 0 V, 0.3 C, -5 C to 55 C, no LCD display, silver 4 sensing.honeywell.com

SCT Series Figure 2. Mounting Dimensions (For reference only: mm/in]) With LCD Display 26,5 [.04] 25,5 [.00] 90 [3.54] 4 [0.6] 96 [3.78] Without LCD Display 26,5 [.04] 25,5 [.00] 90 [3.54] 4 [0.6] 96 [3.78] sensing.honeywell.com 5

Humidity and Temperature Wall Mount Transducers Figure 3. DIP Switch Settings, 2 NS C F %RH Dew point DIP Switch State SW-: On Off SW-2: On Off SW-3 SW-4: SW-5: SW-6: on off off off on off off off on There is no SW- switch assembled if both LCD display and temperature transducer are not configured. 2 New setting with SW switch will be active once the unit is powered up.. Display temperature unit: F C (initial setting) humidity setting: dew point ( F or C depending on SW- setiing) %RH (initial setting) reserved temperature measuring range: -5 C to 55 C (initial setting) 0 C to 70 C -25 C to 60 C Figure 4. Wiring Output Humidity: 4 m to 20 m Temperature: 4 m to 20 m Output B Output C Humidity: 4 m to 20 m SCTHWCX T COM RH VS- VS+ T COM RH VS- VS+ RH VS- VS+ RT RT R = 500 Ohm max. 24 Vdc ±0% V V R = 0 kohm min. 8 Vdc to 40 Vdc or 24 Vac ±5% R = 500 Ohm max. 24 Vdc ±0% Output D Output E Temperature: 4 m to 20 m Output F RH VS- VS+ RT RT T COM VS- VS+ T COM VS- VS+ V R = 0 kohm min. 8 Vdc to 40 Vdc or 24 Vac ±5% R = 500 Ohm max. 24 Vdc ±0% V R = 0 kohm min. 8 Vdc to 40 Vdc or 24 Vac ±5% 6 sensing.honeywell.com

DDITIONL INFORMTION The following associated literature is available at sensing.honeywell.com: pplication Note Installation Instructions WRNING PERSONL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WRNING MISUSE OF DOCUMENTTION The information presented in this datasheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WRRNTY/REMEDY Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest uthorized Distributor, contact your local sales office. To learn more about Honeywell s sensing and control products, call +-85-235- 6847 or -800-537-6945, visit sensing. honeywell.com, or e-mail inquiries to info.sc@honeywell.com Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Productivity Solutions Honeywell 985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 322444--EN IL50 September 205 205 Honeywell International Inc. ll rights reserved.