Automation. Safety of machinery. Notes on the application of standards EN and EN ISO

Similar documents
PABIAC Safety-related Control Systems Workshop


Machineontwerp volgens IEC 62061

Safety and functional safety A general guide

Hardware safety integrity Guideline

How to design safe machine control systems a guideline to EN ISO

Guidelines. Safety Integrity Level - SIL - Valves and valve actuators. March Valves

Version: 1.0 Latest Edition: Guideline

SAFETY MANUAL SIL Switch Amplifier

SAFETY MANUAL SIL SMART Transmitter Power Supply

SAFETY MANUAL SIL RELAY MODULE

Presentation Safety Legislation and Standards

Safe Machinery Handbook

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Safe Machinery Handbook

Introduction to Safety

Understanding Safety Integrity Levels (SIL) and its Effects for Field Instruments

Final Element Architecture Comparison

Failure Modes, Effects and Diagnostic Analysis

Overview of IEC Design of electrical / electronic / programmable electronic safety-related systems

IEC Overview Report

SAFETY MANUAL SIL SWITCH AMPLIFIER

You Must Know About the New RIA Automation Standard

Value Paper Author: Edgar C. Ramirez. Diverse redundancy used in SIS technology to achieve higher safety integrity

FUNCTIONAL SAFETY CERTIFICATE

A methodology For the achievement of Target SIL

Safety Requirements Specification Guideline

SISTEMA - Sicherheit von Steuerungen an Maschinen

IEC Functional Safety Assessment. ASCO Numatics Scherpenzeel, The Netherlands

SIL manual. Structure. Structure

Funktionale Sicherheit IEC & IEC 62443

Is your current safety system compliant to today's safety standard?

General. Industry. Siemens AG, I IA CD, P.O. box 48 48, D Nuremberg. Postal address: Siemens AG I IA CD P.O. box D Nuremberg

Safety Function: Door Monitoring

ELECTROTECHNIQUE IEC INTERNATIONALE INTERNATIONAL ELECTROTECHNICAL

ABB industrial drives. Application guide ACS800-01/U1/04/04LC/04M/U4/11/U11/14/31/U31/104/104LC Safe torque off function (+Q967)

Selecting Sensors for Safety Instrumented Systems per IEC (ISA )

Safety Manual BT50(T) Safety relay / Expansion relay

FMEDA and Proven-in-use Assessment. Pepperl+Fuchs GmbH Mannheim Germany

SIL in de praktijk (Functional Safety) Antwerpen Compliance of Actuators and Life Cycle Considerations. SAMSON AG Dr.

Effective Compliance. Selecting Solenoid Valves for Safety Systems. A White Paper From ASCO Valve, Inc. by David Park and George Wahlers

Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives

The SISTEMA Cookbook 4

SF06. Machine Safety Solutions Overview

Functional safety Standardization activities

Controlling Risks Safety Lifecycle

IEC Functional Safety Assessment. Project: K-TEK Corporation AT100, AT100S, AT200 Magnetostrictive Level Transmitter.

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS

Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines

Automation, Software and Information Technology. Test report of the type approval safety-related automation devices

Application Technique. Safety Function: Door Monitoring

SAFETY LIFE-CYCLE HOW TO IMPLEMENT A

Risk Assessment as the principal element of the CE Conformity Assessment of Wind Turbines

MXa SIL Guidance and Certification

Frequently Asked Questions

Basic Fundamentals Of Safety Instrumented Systems

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

Safety manual for Fisherr ED,ES,ET,EZ, HP, or HPA Valves with 657 / 667 Actuator

I requisiti delle Norme IEC EN Ed 2: 2010 e IEC EN Ed. 2: 2016

ida.com excellence in dependable automation

Functional safety. Essential to overall safety

Frequently Asked Questions

Machinery Safety. Presented by Paul Laidler. TÜV SÜD Product Service

T146 Electro Mechanical Engineering Technician MTCU Code Program Learning Outcomes

University of Paderborn Software Engineering Group II-25. Dr. Holger Giese. University of Paderborn Software Engineering Group. External facilities

Safe and Efficient Hydraulic Systems Review of ISO 4413 Hydraulic Fluid Power General Rules and Safety Requirements for Systems and Their Components

Standards which are relevant to the selection and use of electrical switches for safety related controls in mine shaft and winding systems HSL/2007/58

Viewpoint on ISA TR Simplified Methods and Fault Tree Analysis Angela E. Summers, Ph.D., P.E., President

Reducing Steps to Achieve Safety Certification

CE Marking and Technical Standardisation

SAFETY ENGINEERING SOFTWARE

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Valves and Solenoid Valves testet and certified byrheinhold & Mahla according to IEC 61508/61511

FUNCTIONAL SAFETY INDUSTRIAL


How to Upgrade SPICE-Compliant Processes for Functional Safety

ASSESSMENT OF THE ISO STANDARD, ROAD VEHICLES FUNCTIONAL SAFETY

The Safety Compendium

GuardLogix Controller Systems

An introduction to Functional Safety and IEC 61508

Fisher FIELDVUE Instrumentation Improving Safety Instrumented System Reliability

TÜV Rheinland Functional Safety Program Functional Safety Engineer Certification

TÜV FS Engineer Certification Course Being able to demonstrate competency is now an IEC requirement:

Logic solver application software and operator interface

Bosch Packaging Academy Essential Training

Safety automation solutions

RECOMMENDED GUIDELINES FOR THE APPLICATION OF IEC AND IEC IN THE PETROLEUM ACTIVITIES ON THE NORWEGIAN CONTINENTAL SHELF

What is CFSE? What is a CFSE Endorsement?

The Interaction of Contactors with PLCs

Mary Ann Lundteigen. Doctoral theses at NTNU, 2009:9 Mary Ann Lundteigen. Doctoral theses at NTNU, 2009:9

Software in safety critical systems

Systems Assurance Management in Railway through the Project Life Cycle

DeltaV SIS for Burner Management Systems

SILs and Software. Introduction. The SIL concept. Problems with SIL. Unpicking the SIL concept

Safety Integrated. SIMATIC Safety Matrix. The Management Tool for all Phases of the Safety Lifecycle. Brochure September Answers for industry.

A Methodology for Safety Case Development. Foreword

ISO 26262:2011 Functional Safety Assessment Report. Texas Instruments Richardson, TX USA. Project: TDA2X ADAS SoC. Customer:

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

Transcription:

Automation Safety of machinery Notes on the application of standards EN 62061 and EN ISO 13849-1

IMPRINT Safety of machinery Notes on the application of standards EN 62061 and EN ISO 13849-1 German Electrical and Electronic Manufacturer s Association Stresemannallee 19 60596 Frankfurt am Main Germany Professional Association Automation Specialist Area of Switchgears, Switchgears, Industrial Controls Technical Committee Safety System in Automation Autor: Gunther Bernd Phone: +49 69 6302-323 Fax: +49 69 6302-386 Mail: bernd@zvei.org www.zvei.org/automaton Despite utmost care no liability for contents June 2007

Safety of machinery Notes on the application of standards EN 62061 and EN ISO 13849-1 Are you a machine manufacturer or system integrator? Do you upgrade machinery? 1. Basic procedure for complying with the requirements of the Machinery Directive This is what you need to consider in future in terms of functional safety! Grundsätzliche Vorgehensweise um die Anforderungen der Maschinenrichtlinie zu erfüllen What do I need to do to place a machine on the market in compliance with the directives? The EU Machinery Directive stipulates that machinery should not present a risk (risk assessment in accordance with EN 1050 or EN ISO 14121-1). Given that there is no such thing as zero risk in technology, the aim is to achieve an acceptable residual risk. If safety is dependent on control systems, these must be designed so that the probability of functional errors is sufficiently low. If this isn t possible, any errors that occur shall not lead to the loss of the safety function. To meet this requirement it makes sense to use harmonised standards that have been created in accordance with a mandate from the European Commission and are published in the Official Journal of the European Communities (presumption of conformity). This is the only way to avoid spending extra time and effort demonstrating conformity in the event of a claim. The two standards EN 62061 and EN ISO 13849-1 are compared below. 2. Why is today s EN 954-1 not sufficient for the future? 2. Warum reicht die heutige EN 954-1 zukünftig nicht mehr aus? In the past, the safety-related parts of a machine s control system were designed in accordance with EN 954-1. This was based on the calculated risk (formed into categories). The aim was to set an appropriate system behaviour ( control class ) against a category (deterministic approach). Once electronics, and programmable electronics in particular, had made their mark on safety technology, safety could no longer be measured purely in terms of the simple category system found in EN 954-1. Furthermore, it was unable to provide information on probability of failure (probabilistic approach). Help is now available from EN 62061 and EN ISO 13849-1, the successor standard to EN 954-1. 3

3. Scopes of the two standards EN ISO 13849-1: Safety-related parts of control systems, Part 1: General principles for design This standard may be applied to SRP/CS (safety-related parts of control systems) and all types of machinery, regardless of the type of technology and energy used (electrical, hydraulic, pneumatic, mechanical, etc.). EN ISO 13849-1 also lists special requirements for SRP/CS with programmable electronic systems. EN 62061: Functional safety of safety-related electrical, electronic and programmable electronic control systems This standard defines requirements and gives recommendations for the design, integration and validation of safety-related electrical, electronic and programmable electronic control systems (SRECS) for machinery. It does not define requirements for the performance of non-electrical (e.g. hydraulic, pneumatic, electromechanical) safety-related control elements for machinery. 4. Brief overview of EN ISO 13849-1: 2. Warum reicht die heutige EN 954-1 zukünftig nicht mehr aus? EN ISO 13849-1 is based on the familiar categories from EN 954-1:1996. It examines complete safety functions, including all the components involved in their design. EN ISO 13849-1 goes beyond the qualitative approach of EN 954-1 to include a quantitative assessment of the safety functions. A performance level (PL) is used for this, building upon the categories. Components/devices require the following safety parameters: Category (structural requirement) PL: Performance level MTTFd: Mean time to dangerous failure B10d: Number of cycles by which 10% of a random sample of wearing components have failed dangerously 4

DC: CCF: TM: Diagnostic coverage Common cause failure Mission time The standard describes how to calculate the performance level (PL) for safety-related parts of control systems, based on designated architectures, for the designated mission time TM. EN ISO 13849-1 refers any deviations to IEC 61508. Where several safety-related parts are combined into one overall system, the standard describes how to calculate the PL that can be achieved. For additional guidelines on validation EN ISO 13849-1 refers to Part 2, which was published at the end of 2003. This part provides information on fault considerations, maintenance, technical documentation and usage guidelines. The transition period from EN 954-1 to EN ISO 13849-1 is likely to end in October 2009. Until then, either standard may be applied. 5. Brief overview of EN 62061 2. Warum reicht die heutige EN 954-1 zukünftig nicht mehr aus? EN 62061 represents a sector-specific standard under IEC 61508. It describes the implementation of safety-related electrical and electronic control systems on machinery and examines the overall lifecycle from the concept phase through to decommissioning. Quantitative and qualitative examinations of the safety-related control functions form the basis. The performance level is described through the safety integrity level (SIL). The safety functions identified from the risk analysis are divided into safety subfunctions; these safety subfunctions are then assigned to actual devices, called subsystems and subsystem elements. Both hardware and software are handled this way. A safety-related control system is made up of several subsystems. The safety-related characteristics of these subsystems are described through parameters (SIL claim limit and PFHD). 5

Subsystem 1 Subsystemelement 1.1,T1 Subsystemelement 1.2,T1 DC, T2, Subsystem 1 (Sensor A) SIL CL, PFH D,T1 Subsystem 2 (Sensor B) SIL CL, PFH D,T1 Subsystem 3 (PLC to IEC 61508) SIL CL, PFH D,T1 Subsystem 4 (Actuator) SIL CL, PFH D,T1 SIL Safety-related parameters for subsystems: SILCL: SIL claim limit PFHD: Probability of dangerous failure per hour T1: Lifetime These subsystems may in turn be made up of various interconnected subsystem elements (devices) with parameters to calculate the subsystem s corresponding PFHD value. Safety-related parameters for subsystem elements (devices): : Failure rate; for wearing elements: describe via the B10 value SFF: Safe failure fraction On electromechanical devices the failure rate is indicated by the manufacturer as a B10 value, based on the number of cycles. The time-based failure rate and lifetime must be determined through the switching frequency for the respective application. 6

Internal parameters to be established during design / construction for a subsystem comprised of subsystem elements: T2: Diagnostic test interval : Susceptibility to common cause failure DC: Diagnostic coverage PFHD: The PFHD value of the safety-related control system is calculated by adding the subsystems individual PFHD values. Users have the following options when designing a safety-related control system: Use devices and subsystems that already comply with EN 954-1 and IEC 61508 or EN 62061. The standard specifies how to incorporate qualified devices when implementing safety functions. Develop their own subsystems. Programmable, electronic subsystems or complex subsystems: Apply IEC 61508. Simple devices and subsystems: Apply EN 62061. The standard represents a comprehensive system for the implementation of safety-related electrical, electronic and programmable electronic control systems. EN 62061 has been a harmonised standard since December 2005. EN 954-1, or alternatively EN ISO 13849-1, should be applied for nonelectrical systems. 6. Achieving safety, step-by-step Basic procedure 2. Warum reicht die heutige EN 954-1 zukünftig nicht mehr aus? Step 1 Risk assessment in accordance with EN 1050 / EN ISO 14121 It can be assumed that a hazard on a machine will result in harm sooner or later if safety measures are not put in place. Safety measures are a combination of these measures taken by the designer and those implemented by the user. Measures taken at the design 7

Risk assessment Risk analysis phase are preferable to those implemented by the user, and generally they are also more effective. The designer must follow the sequence described below, bearing in mind the experience gained by users of similar machinery and information gained from discussions with potential users (if this is possible): Establish the limits and the intended use of the machinery; Start Identify the hazards and any associated hazardous situations; Limits of the machinery Estimate the risk for each Hazard identification identified hazard and Risk estimation hazardous situation; Risk evaluation Evaluate the risk and decide on No the need for risk reduction. Approach during the machine design Machinery safe? Risk reduction Yes EN 1050 and EN ISO 14121 END Step 2 Define the measures required to reduce the calculated risks The objective is to reduce risk as much as possible, taking various factors into account. The process is iterative; making the best possible use of the available technologies it may be necessary to repeat the process several times in order to reduce the risk. When carrying out the process, the following priority ranking shall apply: 1. Safety of the machine in all phases of its lifetime; 2. The ability of the machine to perform its function; 3. User friendliness of the machine. Only then shall the machine s manufacturing, operating and disassembly costs be taken into consideration. 8

The hazard analysis and risk reduction process requires hazards to be eliminated or reduced through a hierarchy of measures: Hazard elimination or risk reduction through design Risk reduction through technical protection devices and potential additional protective measures Risk reduction through the availability of user information about residual risk Design and risk evaluation of the machine EN ISO 12100 Functional and safety requirements for safety related control systems Design and realisation of safety related electrical control systems EN ISO 13849 EN 62061 Step 3 Risk reduction through control measures If safety-related control parts are used to control a protective measure in order to achieve the necessary risk reduction, the design of these control parts shall be an integral part of the whole design procedure for the machine. The safetyrelated control system provides the safety function(s) with a SIL or PL that achieves the necessary risk reduction. Electrical safety aspects EN IEC 60204 9

Step 4 Implementation of control measures using EN ISO 13849-1 or EN 62061 1) Determination of the required performance level EN ISO 13849-1 EN ISO 13849-1 EN 62061 EN 62061 2) Specification The specification of the functional requirements shall describe each safety function that is to be performed. Any interfaces with other control functions shall be defined and any necessary error reactions established. The required SIL or PL must be defined. 3) Design of the control architecture Part of the risk reduction process involves the definition of the machine s safety functions. This includes the safety functions on the control system, e.g. to prevent unexpected start-up. When defining the safety functions it is always important to consider that a machine has different operating modes (e.g. automatic & setup mode) and that the safety measures in these different modes may be totally different (e.g. safely limited speed in setup mode <-> two-hand in automatic mode). A safety function may be implemented via one or more safety-related control parts and several safety functions may be divided over one or more safety-related control parts (e.g. logic module, energy transmission element(s)). 10

4) Determination of the achieved performance level EN ISO 13849-1 EN 62061 The PL shall be estimated for each selected SRP/CS and/or combination of SRP/CS that performs a safety function. The PL of the SRP/CS shall be determined by the estimation of the following parameters: The MTTFd value for single components The DC The CCF The structure (category) The behaviour of the safety function under fault condition(s) Safety-related software Systematic failures The ability to perform a safety function under expected environmental conditions The selection or design of the SRECS shall always meet the following minimum requirements: Requirements for hardware safety integrity, comprising Architectural constraints for hardware safety integrity Requirements for the probability of dangerous random hardware failures plus requirements for systematic safety integrity, comprising Requirements for avoidance of failures and Requirements for the control of systematic failures. EN 62061 also describes requirements for implementing application programs. Safety-related parameters for subsystems: SILCL: PFHD: T1: SIL claim limit Probability of dangerous failure per hour Lifetime 11

EN ISO 13849-1 EN IEC 62061 Probability (average) of a Performance failure to danger level [1/h] a 10-5 < PFH < 10-4 b 3 10-6 < PFH < 10-5 c 10-6 < PFH < 3 10-6 d 10-7 < PFH < 10-6 e 10-8 < PFH < 10-7 Probability (average) of a failure to danger [1/h] SIL Level 10-6 < PFH < 10-5 SIL 1 10-7 < PFH < 10-6 SIL 2 10-8 < PFH < 10-7 SIL 3 Safety-related parameters for subsystem elements (devices): : Failure rate B10 value: For wearing elements T1: T2: : DC: SFF: HTF: Lifetime Diagnostic test interval Susceptibility to common cause failure Diagnostic coverage Safe failure fraction Hardware fault tolerance SFF HFT 0 HFT 1 HFT 2 < 60% Not allowed SIL 1 SIL 2 60% to < 90% SIL 1 SIL 2 SIL 3 90% to < 99% SIL 2 SIL 3 SIL 3 >=99% SIL 3 SIL 3 SIL 3 Note: The PFHD comparisons are an essential requirement for determining the performance level. To complete the determination of the PL, CCF, category and DC shall also be considered. 12

EN ISO 13849-1 EN IEC 62061 Performance level SIL Level a -- b SIL 1 c SIL 1 d SIL 2 e SIL 3 Note: The illustration describes the relationship between the standards two concepts (PL and SIL), based on probability of failure. 5) Verification For each individual safety function, the PL of the corresponding SRP/CS must match the Required Performance Level. Where various SRP/CS from part of a safety function, their PLs shall be equal to or greater than the performance level required for this function. Where several SRP/CS are connected in series, the final PL can be determined using Table 11 from the standard. The probability of dangerous failure of each safety-related control function (SRCF) as a result of dangerous random hardware failures shall be equal to or less than the failure threshold value defined in the specification of the safety requirements. The SIL that is achieved by the SRECS on the basis of architectural constraints shall be less than or equal to the lowest SILCL of any subsystem involved in performing the safety function. 6) Validation The design of a safety-related control function shall be validated. The validation must show that the combination for each safety function of the safety-related parts meets the relevant requirements. 13

7. Glossary Abbreviation Explanation B10d s d CCF DC DCavg Number of cycles until 10% of components fail causing danger Failure Rate Failure Rate (failure to safe side) Failure Rate (failure to danger) Common cause failure Diagnostic coverage Average diagnostic coverage Designated Architecture Designated architecture of an SRP/CS HFT Hardware fault tolerance MTBF Mean time between failures (during normal operation) MTTF Mean time to failure MTTFd Mean time to dangerous failure MTTR Mean time to repair (always significantly less than the MTTF) PFH Probability of failure per hour PFHD Probability of dangerous failure per hour PL Performance Level, Ability of safetyrelated parts to perform a safety function under foreseeable conditions, to achieve the expected risk reduction PLr Required performance level SIL Safety integrity level 14

Abbreviation Explanation SILCL SRP/CS SRECS T1 T2 TM C SFF Security Safety Machinery safety Functional safety SIL claim limit (suitability) Safety-related parts of a control system Safety-related electrical control systems Lifetime or proof test interval, assumed lifetime of safety system Diagnostic test interval Mission time Susceptibility to common cause failure Duty cycle (per hour) of an electromechanical component Safe failure fraction Common term for protective guarding. A person or item is safeguarded through monitoring. Collective term for functional safety and machinery safety, among others State achieved when measures have been taken to reduce the risk to an accepted residual risk after the hazard analysis has been carried out. Part of the safety of the machine and the machine control system which depends on the correct functioning of the SRECS, other technology safetyrelated systems and external risk reduction facilities 15

8. FAQ list Do solenoid valves / contactors have a SIL or PL rating? No. Single components cannot have a SIL or PL rating. What is the difference between SIL and SILCL? The SIL rating always refers to a complete safety function while the SILCL refers to the subsystem. Is there an analogy between PL and SIL? A relationship between PL and SIL can be established through the PFH value. (See step 4: Determination of the achieved performance level ). Performance level (EN13849-1) Probability of a dangerous failure per hour [1/h] SIL Level after EN IEC 62061 b 3 10-6 < PFH < 10-5 SIL 1 c 10-6 < PFH < 3 10-6 SIL 1 d 10-7 < PFH < 10-6 SIL 2 e 10-8 < PFH < 10-7 SIL 3 What diagnostic coverage can I claim for relays and contactors with positive-guided contacts? In accordance with both standards, a DC of 99% can be assumed due to the positive-guided contacts on contactors and relays. A diagnostic function with an appropriate error reaction is a prerequisite. 16

Can I achieve a hardware fault tolerance of 1 with a single door monitoring (safety gate) switch? No, just one error would cause the circuit to fail. Is there a probability of failure or PFHD value for wearing components? No. Users can calculate a PFH value for wearing components on the specific application using the B10 value in relation to the number of duty cycles. What is the difference between MTBF and MTTF? The MTBF describes the time between two failures, whereas MTTF describes the time to the first failure. What does the letter d mean on MTTFd? d stands for dangerous > the MTTFd describes the mean time to the first dangerous failure. May I apply EN ISO 13849-1 when integrating complex programmable electronics? Yes. However, for operating system software and safety functions in accordance with PL e, the requirements of IEC 61508-3 will need to be considered. What can I do if I do not receive any characteristic data from my component manufacturer? The annexes of both EN ISO 13849-1 and EN 62061 contain substitute reference values for frequently used components. Where available, however, manufacturer s values should always be used. 17

Can I apply EN ISO 13849-1 to calculate the MTTF on process valves/armatures that are only switched once or twice a year (low demand)? No, EN ISO 13849-1 only describes high demand mode, so an MTTF assessment can only be made using additional measures such as forced dynamisation. Can I apply EN 62061 to calculate the failure rate on process valves/armatures that are only switched once or twice a year (low demand)? See question above. Does application software have to be certified? If Yes, to which standard? No. There is no mandatory certification for either standard. However, there may be mandatory certification for Annex IV machines under the Machinery Directive (e.g. presses). Requirements for software production can be found in both EN 62061 and EN ISO 13849-1. 18

German Electrical and Electronic Manufacturers Association Stresemannallee 19 60596 Frankfurt am Main Germany Professional Association Automation Specialist Area of Switchgears, Switchgears, Industrial Controls Technical Committee Safety System in Automation