Autoclaved aerated concrete for construction in hot regions

Similar documents
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Green Architecture and Construction

Studies energy efficiency of the renewable sources use considering climate in Latvia

How To Improve Energy Efficiency In Brazilian Buildings

HEAT TRANSFER ANALYSIS OF COLD STORAGE

Xella. Masonry innovations seminar. 16 February 2016

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Dubai Municipality Standard DMS 1: Part 5: 2004

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving

YTONG Product list.

HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT

PRODUCT GUIDE lower tolerances high quality

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

Technical Manual - Section 1 Introduction to Lytag lightweight aggregate

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

PRODUCT GUIDE. Building the future with Ytong autoclaved aerated concrete. low tolerances high quality

Energy Efficient Building Design College of Architecture Illinois Institute of Technology, Chicago. Ceiling/Airspace

STRENGTH OF CONCRETE INCORPORATING AGGREGATES RECYCLED FROM DEMOLITION WASTE

New Thermal Architecture For Future Green Data Centres

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Determination of Thermal Conductivity of Coarse and Fine Sand Soils

Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls

Solar Aquaponics Designing a 100% Solar Aquaponics Greenhouse

The Influence Of Window Type And Orientation On Energy-Saving In Buildings Application To A Single Family Dwelling

Energy efficiency building standards in Japan

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

Unbeatable energy efficient glass curtain wall system

FIXIT.CH. Aerogel Insulating Plaster System. Handling Guidelines. Easy to use. Mineral based W/mK BAUSTOFFE MIT SYSTEM

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

Market Potential Study for Water Heater Demand Management

The interested agency/ Institution may apply with the following details;

Example Specification for Concrete using Current Building Code Requirements

Adaptive strategies for office spaces in the UK climate

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

PRO. English COMPLETE PRECAST PLANT

Residential HVAC System Sizing

ANALYSIS OF INDOOR PERFORMANCE OF HOUSES USING RAMMED EARTH WALLS. Veronica Soebarto The University of Adelaide, Adelaide, Australia

) and air spaces (R a

Heating Load Calculation

Software Development for Cooling Load Estimation by CLTD Method

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION

Module 3.7. Thermal bridging

Energy Efficiency in Buildings

Commercial Building Valuation Report

MCQ - ENERGY and CLIMATE

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Net Zero Station Design for The Cooper Centre for the Environmental Learning in Tucson, Arizona: Improving the performance of existing buildings

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

Scenario analysis of Carbon Trade for Energy Efficient Renovations of. Operation Manual (take Beijing as an example)

EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS

LAYING BLOCK AND BRICK

Life Cycle Assessment of zero- emission façade construction

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

PV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY

Compliance Software COMcheck 2 and ENVSTD 3

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION.

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

19 Examples of Wall Insulation

Long-Term Hygrothermal Performance of Green Roofs

Crawl space heat and moisture behaviour

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Windows are one of the most important components of a

Chapter Two Types of Cement The properties of cement during hydration vary according to:

PROPERTIES AND MIX DESIGNATIONS

EVALUATION OF GEOTHERMAL ENERGY AS HEAT SOURCE OF DISTRICT HEATING SYSTEMS IN TIANJIN, CHINA

Aquifer Thermal Energy Storage Application in Greenhouse Climatization

The calculus and simulation of underfloor heating systems

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Recycled Concrete Pavement and Other Recycled Materials in Concrete Pavements

School in Schwanenstadt, Austria

OLD BUILDINGS RESTORATION TECHNIQUE. Dr-Ing JK Makunza University of Dar es Salaam 18 th May 2011

Dharam V. Punwani President, Avalon Consulting, Inc. Presented at Turbine Inlet Cooling Association Webinar April 9, 2014

Stone crusher dust as a fine aggregate in Concrete for paving blocks

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E

Fire and Concrete Structures

Development of conservation compatible new materials for envelope retrofitting of historic buildings

HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS

Rockwool Flexi Insulation Application Guide

2016 ERCOT System Planning Long-Term Hourly Peak Demand and Energy Forecast December 31, 2015

1..GENERAL DATA 2. CLIMATIC DATA. Location

Integrated Solar Radiant Systems

Introduction to Energy Performance of Brick Masonry

Mold Preventing I nterior System

Understanding Heat Transfer

Mass Concrete. Robert Moser CEE8813A Material Science of Concrete. Definitions & Standards, Thermal Cracking, and Temperature Rise

CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS

Guidelines for Durable Driveways, Carports Patios, Walks, Garage Floors

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products

KUHMO: the perfect example of local bioenergy production

Improving thermal insulation of concrete sandwich panel buildings

Condensing Boiler Efficiency

Transcription:

Autoclaved aerated concrete for construction in hot regions H. Almudhaf and F. Al-Ragom, Kuwait Institute for Scientific Research, Kuwait Abstract The common construction system used in Kuwait is a frame structure consisting of reinforced heavy concrete beams and columns with reinforced floors and roof slabs. Walls are constructed by filling the skeleton with masonry blocks. This type of construction is the dominating system used in the Arabian Gulf Countries and is even used in one and two story residential buildings. Autoclaved aerated concrete (AAC) was introduced in the mid 1980 s as an alternative material that can provide both the structural and heat resistance characteristics required. AAC is produced as masonry units to be constructed in RC skeleton construction, in addition to reinforced AAC panels which are constructed as a homogeneous AAC precast system. This paper reviews the performance of buildings constructed using AAC. The structural and thermophysical properties are presented. Patterns of energy consumption of a typical building were developed using a computer building simulation program and energy savings calculated. Finally the findings are reflected on the national scale as environmental aspects of the production process, building performance and power supply requirements. Keywords: Autoclaved aerated concrete, building performance, energy consumption, hot regions.

1 Introduction Concrete frame structure is the common construction system in Kuwait. Such a system consists of a skeleton of reinforced concrete beams and columns with reinforced concrete floor and roof slabs. Walls are constructed by filling the skeleton with masonry blocks. This type of construction is even used in one and two story residential buildings. Load bearing wall construction is rarely used. The most commonly used masonry blocks are made of solid heavy concrete with a low compressive strength. With such practices, the unit weight of wall construction could reach 380 kg/m2 while the unit weight of roofs reaches up to 440 kg/m2. Kuwait s summer lasts from April to October; it is hot, with maximum temperature reaching 50 OC or more in shade; and it is dry, although relative humidity can reach 60% in late summer and 90% in autumn and winter. Solar radiation is high; in late summer it may reach 1,100 W/m2, and there are more than 230 days of clear sky in a year. Winter temperatures are in the range of lo-20 OC. Rainfall, which occurs between October and May, is sparse; it may range from as little as 50 mm to more than 300 mm. Average wind speed is 3 m/s. The prevailing wind is northwesterly and is dry, since it passes over a large region of desert; the secondary wind is southeasterly and moist, since it comes in from the Arabian Gulf. Electrical energy consumption is governed by the need for space cooling, to the extent that air-conditioning peak power consumption in Kuwait during the summer reaches 70% of the total generated. The excessive demand for air-conditioning is attributed to the extreme ambient air temperature during the summer. Though a large proportion of the increase in demand has been caused by the steady increase in per capita consumption, an important factor contributing to the increasing consumption rate is the government s subsidy to consumers, reflected by the low price of the electric unit. This is as low as 2 fils/kwh, representing 5% of the actual present cost. Another factor is the erroneous assumption that, due to the wide availability of low-cost fuel in oil-rich countries, like Kuwait, power generating costs are trivial. In fact, the production, transmission and distribution costs of electric power place a heavy burden on the state budget, in light of the world energy crisis and such factors as the import of equipment and technical skills. 2 Energy conservation measures In response to the rapid increase in electricity demand, conservation measures had to be introduced and enforced to curtail the energy requirements in buildings. The Kuwaiti Ministry of Electricity and Water (MEW) code of practice for energy conservation in buildings [l] sets several requirements to limit the peak loads for space cooling. The peak electrical load for residential buildings is set at a maximum of 65 W/m2. To meet such requirements, the code presents target minimum standard for energy conservation - measures. Table 1 specifies maximum thermal transmission allowed for walls and roofs of heavy construction. To comply with the Kuwaiti energy code, exterior heavy walls should include a layer of 5 cm thermal insulation material while a 7 cm thermal insulation material should be embedded within heavy roof sections. Table 1. Maximum Thermal Transmission (U-Value) Allowed for Walls and Roofs of Heavv Construction. Maximum Overall U-Value BTU/h ft2 OF W/m2K Wall 0.10 0.57 Roof 0.07 0.40

3 Autoclaved aerated concrete The enforcement of strict limits on the thermal resistance for exterior walls gave way to the introduction of autoclaved aerated concrete blocks as an efficient material that can provide the necessary thermal insulation properties without the use of specific thermal materials. Autoclaved aerated concrete was developed at the end of the 1920 s in Sweden [2]. Cement and lime, together with siliceous fine materials such as sand, slag or fly-ash and water, are used as raw materials. A small amount of aluminum powder is added. A chemical reaction between the aluminum powder and the lime increases the volume by forming air-filled cells. The product is autoclaved for 10 hours at 10 atm at 180 OC. The autoclaving initiates a reaction between the calcium and silica to form calcium hydrosilicates. Autoclaved aerated concrete has a low bulk density and a particularly favorable ratio between material strength and bulk density. The lower bulk density consequently causes a lower consumption of raw materials which is shown by the way of comparison to other building materials in figure 1 [3]. Furthermore, autoclaved aerated concrete posses remarkable possibilities for waste processing and recycling. Since the material can be easily cut and sawed with simple tools making it possible to reduce the waste in the site to a minimum. A main feature in that is the recycling processes used in typical AAC plants. Density kg/m3 concrete bricks porous bricks sandlime bricks AK Fig. 1 Consumption of raw materials in the production of building materials [3]. Autoclaved aerated concrete, being a light weight material, provides a useful thermal inertia because it possesses an advantageous combination of mass, thermal conductivity and specific heat properties. This means that autoclaved aerated concrete can reduce the extremes of internal temperature compared with buildings made of lighter structures

(which have minimal thermal capacity) or heavier structures (providing less thermal insulation). During the warm season, the thermal inertia of an autoclaved aerated concrete roof of normal thickness works in such a way that inside the building the rise of temperature due to solar radiation is delayed by as much as 6-12 hr, countedfrom the time of the day when the solar radiation is at its maximum. After this time the effect of radiation decreases considerably. The roof then emits its accumulated heat during the conditioning [4]. T Exterior sol-air Heat gain/loss L-- Time Lag -b Fig. 2 Dynamic heat flow [4]. 4 Use of autoclaved aerated concrete in Kuwait Autoclaved aerated concrete blocks are produced in Kuwait in densities ranging from 450 to 600 kg/m3. The most common size is 60 x 20 x 20 cm. A special 2-mm thick epoxy glue mortar is used to bond the blocks. With its superior thermal insulation properties, a 20 cm thick autoclaved aerated concrete block wall finished with sand cement rendering and sand lime brick can satisfy the Kuwaiti energy code without the addition of a thermal insulation material. Precast autoclaved aerated concrete panels are also produced for use in roof wall construction. Typical panel size is 25 x*60 x 200 cm with densities reaching up to 900 kg/m3. A building constructed using autoclaved aerated concrete panels precast system in the building envelope (roof and walls construction) will maintain the advantages of this type of construction to its full extent when compared with the mixed system currently used in Kuwait where autoclaved aerated concrete blockwork is integrated with a heavy reinforced concrete frame structure.

5 Energy consumption patterns To analyze the effect of energy consumption, a typical Kuwaiti house was considered. The technique employed to predict the thermal performance of the building used computer based building simulation. Figure 3 shows a typical hourly power consumption for the building constructed using conventional heavy weight wall and roof systems for both insulated and uninsulated cases. On the national scale, power consumption have been increasing steadily as shown in figure 4. It should be noted that the drop in 1991 was due to the interruptions induced by the Iraqi invasion during 1990/91. A 200 180 2 160 I 2 140 g 120 0 i -4 -a \ No Insulation g 100 2 80 c!l -f 6o 8 40 o 20 0 I I I I I I I I I I I I I 1 1 1 1 1 1 1 i I I I I 1 1 I I I I I I I I I I I I I I I ;-: z 8 8 ti 8 r;: 8 ti 09 0 I? 8 z 09 8 s.. 46 \ c9 ti r;: 6) \ \ \ \ - ;J 2 TIME. F%. 3 Typical hourly power consumption for a Kuwaiti house. 8000 7000 0 Fig. 4 Peak power consumption compared to installed capacity in Kuwait [4].

As discussed earlier, buildings constructed using autoclaved aerated concrete are expected to posses different hourly power consumption pattern in which the peak load is expected to shift compared to the traditional heavy weight structures. As autoclaved aerated concrete is considered lighter in mass, it is predicted that the peak load will occur with a less time lag compared to heavy structures. Hence if the overall peak load for the residential sector, which represents 85% of the total number of power consumers in Kuwait [5], occurs on 4:00 pm, the amplitude of such peak load can be reduced by shifting to other construction systems that can maintain a different peak time, in this case autoclaved aerated concrete. Assuming a target of 30% of residential buildings constructed using autoclaved aerated concrete, expected to maintain a time lag that is 2 hours shifted from the 4:00 pm current peak time, will reflect on a peak load shaving of around 260 MW on the national scale. Further demonstration analysis and studies are required to determine the exact reduction in the national peak load as conservatively expressed earlier. It should be noted that achieving such percentage of residential buildings that utilize autoclaved aerated concrete construction is not a difficult goal. A direct sector that can be targeted is the governmental housing program that is expected to deliver around 1000 housing unit annually. 6 Discussion and recommendations Autoclaved aerated concrete is a building material which can be produced with low consumption of raw materials some of which are recycled waste. It offers remarkable heat insulation characteristics while maintaining strength requirements. The light weight and thermal inertia properties of the material provides a useful energy consumption pattern that, when integrated with other buildings of different mass, can contribute effectively in peak load reduction on power plants. A national plan need to be developed for the optimum distribution of buildings as heavy, medium and light weight construction. The optimization will contribute further into reducing the electric peak load consumption. To encourage such shift in the construction industry, incentives need to be developed. Such incentive may be lower prices of the electric unit or defining a lower thermal resistance requirements for light weight walls and roofs. Some authorities have recognized the thermal inertia contribution, such as the California Energy Commission which defines lower R-values PI. References 1. 2. 3. 4. 5. Ministry of Electricity and Water (1983) Code of Practice for Energy Conservation in Kuwaiti Buildings, Report R-6, Kuwait. Dubral, W. (1992) On production and application of AAC worldwide. Autoclaved Aerated Concrete: Properties, Testing and Design, edited by F. W. Wittman, E&FN Spon, London. Hums, D. (1992) Ecological aspects for the production and use of autoclaved aerated concrete. Autoclaved Aerated Concrete: Properties, Testing and Design, edited by F. W. Wittman, E&FN Spon, London. RILEM Recommended Practice ( 1993) Autoclaved Aerated Concrete: Properties, Testing and Design, E&FN Spon, London. Ministry of Electricity and Water (1996) Statistical Year Book, Kuwait.