THERMAL EFFICIENCY OF THE WINDOW SHADE. University of Pennsylvania, Philadelphia, PA, USA

Similar documents
ResearcH JournaL 2009 / VOL

Adaptive strategies for office spaces in the UK climate

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

3-D Modeller Rendered Visualisations

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

Selecting Energy Efficient Replacement Windows in Nevada

Selecting Energy Efficient New Windows in Georgia

Selecting Energy Efficient New Windows in Arizona

The Influence Of Window Type And Orientation On Energy-Saving In Buildings Application To A Single Family Dwelling

Tech Bulletin. Understanding Solar Performance

Selecting Energy Efficient New Windows in Texas

Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance

Energy Efficient Hospital Patient Room Design: Effect of Room Shape on Windowto-Wall Ratio in a Desert Climate

SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION.

Unbeatable energy efficient glass curtain wall system

What is Solar Control?

Selecting Energy Efficient New Windows in Florida

Design Guidance for Schools in Washington, DC

Thermal Breakage Prediction

SELECTIVE GLAZING FOR SUN CONTROL

SKY-TILE SKY-TILE. Daylight Consultants web: blog: espaciosolar.blogspot.com. Bioclimatic Modular Skylights

Elegance SC. Solar Control

Design Guidance for Schools in Phoenix, Arizona

ENERGY AUDIT. Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM):

LOW-E PHOTOVOLTAIC GLASS TECHNICAL GUIDE

Selecting Energy Efficient New Windows in California

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Residential Windows, 3 rd edition Corrected index 1

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

AN APPLICATION MANUAL FOR BUILDING ENERGY AND ENVIRONMENTAL MODELLING

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING

Application of advanced glazing to mid-rise office buildings in Malaysia

Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

CHAPTER 3. The sun and the seasons. Locating the position of the sun

Full credit for this chapter to Prof. Leonard Bachman of the University of Houston

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

THERMAL DESIGN AND TEST REQUIREMENTS FOR OUTSIDE PLANT CABLE TELECOMMUNICATIONS EQUIPMENT Al Marshall, P.E. Philips Broadband Networks

The Three Heat Transfer Modes in Reflow Soldering

Software Development for Cooling Load Estimation by CLTD Method

Solar Energy Utilisation in Buildings

Decision-making Methodology & Selection Tools for High-performance Window Systems in U.S. Climates Kerry L. Haglund 1

Energy Efficient HVAC-system and Building Design

薄 膜 對 提 高 樓 宇 窗 戶 性 能 的 研 究 分 析

Chapter 2: Solar Radiation and Seasons

Assessing the Effects of Glazing Type on Optimum Dimension of Windows in Office Buildings

The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows

BER Assessors Dwellings Technical Bulletin

Efficient use of energy simulation in the early design phase

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

User operations and preferences in a test room equipped with advanced natural and artificial light sources

Design Optimization of Glazing Façade by Using the GPSPSOCCHJ Algorithm

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

RESNET National Rater Test Study Guide Outline

Parametric Analysis of School Classroom Typologies' Energy Performance

Daylight Adaptive Shading Using Parametric Camshaft Mechanism for SOHO in Jakarta

The importance of Software to calculate the ability of Architecture to reduce energy demand in buildings

SOLAR ENERGY How much strikes the earth? How much can my building get? When is it too much?

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

Sabine Hoffmann, Eleanor S. Lee. Environmental Technologies Area

Application Note - How to Design a SolarEdge System Using PVsyst

Influence of Solar Radiation Models in the Calibration of Building Simulation Models

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy. For Tech Traders Inc. By H. F. Poppendiek

Linear thermal transmittance of the assembly of the glazing and the frame in windows

Passive Solar Design and Concepts

Marko G. IGNJATOVIĆ *, Bratislav D. BLAGOJEVIĆ, Branislav V. STOJANOVIĆ, and Mladen M. STOJILJKOVIĆ

Optimum Solar Orientation: Miami, Florida

Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products

Effect of design parameters on temperature rise of windings of dry type electrical transformer

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

PROTOCOL FOR BUILDING ENERGY ANALYSIS SOFTWARE For Class 3, 5, 6, 7, 8 and 9 buildings

Using Computational Fluid Dynamics (CFD) for improving cooling system efficiency for Data centers

Energy and Buildings

OPTIMIZATION OF VENTILATION SYSTEMS IN OFFICE ENVIRONMENT, PART II: RESULTS AND DISCUSSIONS

Greenhouse Glazing Effects on Heat Transfer for Winter Heating and Summer Cooling

Building Information Modelling (BIM); How it Improves Building Performance. R.P. Kumanayake Lecturer, Department of Civil Engineering

Paul Linden & Guilherme Carrilho da Graça. NaturalWorks Inc

AIRCONDITIONING Cooling Loads Calculations

NEW CEILING MODULE DS-W1 WAVE : SUBSTANTIALLY HIGHER CAPACITY AND ENERGY EFFICIENCY

ENERGY AUDITS IN DWELLING BUILDINGS IN LATVIA. DATA ANALYSIS

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Thermal comfort and Energy Efficiency in

Systems Selection Enclosure Systems Material Selection Assessment and Mitigation

Case Study 13 Schools of Architecture and Design, Wellington tertiary education institute, New Zealand

EXPERIMENTAL ANALYSIS OF PARTIAL AND FULLY CHARGED THERMAL STRATIFIED HOT WATER STORAGE TANKS

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Natural Convection. Buoyancy force

CHAPTER 6: WINDOWS AND DOORS

Application of Neural Network in User Authentication for Smart Home System

CIBSE Weather Files 2016 release: Technical Briefing and Testing

Thermal Simulation of a Power Electronics Cold Plate with a Parametric Design Study

Transcription:

Eleventh International IPS Conference Glasgow, Scotland July 27-30, 2009 THERML EFFICIENCY OF THE WINDOW SHDE Yun Kyu Yi, 1 and li M. Malkawi 1 1 T.C. Chan Center for uilding Simulation and Energy Studies, University of Pennsylvania, Philadelphia, P, US STRCT The purpose of this paper is to find the efficiency of window shades regarding building energy performance and explore the possibility of developing a model that enables users to find proper shades for their specific conditions. The paper investigates different options of shades and their related variables and finds the efficiency of the shades regarding energy load. Each variable was investigated for its effect on the heat loads. Results were used as input variables for neural network prediction model. prediction model was developed and trained based on the previous simulation results. Ten different shade cases were used to test the accuracy of the prediction model, and the outcomes of the prediction model were compared with energy simulation results to find its robustness. KEYWORDS Shade, Energy, Performance, Neural Network, Sensitivity INTRODUCTION Window shades are commonly used in buildings for blocking the direct sun to reduce glare indoors. Their function can be extended as a thermal buffer too. Shades can reduce direct solar radiation, which reduces the heat gain and heat loss as well. Research concerning window shades were focused on the efficiency of light levels to reduce direct solar radiation and increase indoor light levels to reduce artificial lighting (Cheung and Chung, 2007; Ihm et al., 2009); other studies addressed automatic controllability of the shades as an operative management problem (Laha, et al., 2005). The thermal performance aspect of shades was investigated at a basic level several decades ago (Olgyay, 1957); however, recently shades have been investigated relation to their specific project use. (Lee and Tavil, 2007; Tanaka, H. Et al., 2008; Ochoa and Capeluto, 2009; aldinelli, 2009). comprehensive study for their effect on glass has not been fully investigated. This paper provides the being of such an investigation and sets frame work for further investigations. Shades need a low initial investment to install. If their thermal effectiveness is greater than the investment, shades can be the optimum solution for improving an existing poor performance of windows in the building. This study investigated roller shades using transit energy simulation analysis to predict their impact on the energy performance of a building and investigate their efficiency and their sensitivity depending on variances between different materials. The thermal behaviour of window shades is influenced by several variables including their geometry, the properties of the materials used, their orientation and location. Due to those influences, the study investigated different scenarios to capture all the variances of the shades. The resulting data was used to develop a prediction model that suggests different shades thermal performance without generating complicated energy simulation models for different scenarios (Figure 1). This study utilizes the Neural Network as the prediction model. Different scenarios of the shades variation were predicted by the network model, and results were compared with the energy simulation. This verifies the accuracy of the prediction model and its limitation. Figure 1. Overall process - 1693 -

WINDOW SHDE INVESTIGTION Different geometric and physical properties of the elements of the window shade will affect its performance. To predict these effects, sixty-six tests were performed, with three locations, two glass types, with or without shades, two different shade distances from the window, and five different shade types. Each test was simulated for a year with hourly time steps (Figure 2). Figure 2. Various conditions for simulation : ack Side IR Transmittance at Normal 0 IR Hemispherical Emissivity: Front 0.84 Side IR Hemispherical Emissivity: ack Side 0.87 Conductivity {W/m-K} 0.9 ir Thickness {m} 0.0127 Inside Thickness {m} 0.0063 Solar Transmittance at Normal 0.6 0.1 : : ack Side 0.85 0.102 : : ack Side IR Transmittance at Normal 0 IR Hemispherical Emissivity: Front 0.84 Side IR Hemispherical Emissivity: ack Side 0.87 Conductivity {W/m-K} 0.9 model with typical room dimensions was constructed (Depth 7790mm x Width 6700mm x Height 2850mm). It has one window (Width 6000mm x Height 2050mm) facing the south. Internal shading was constructed to perform a transit thermal simulation. The simulations were conducted for different conditions regarding location, glass, and shade types. Three locations were selected to represent different climate conditions that represent hot, temperate and cold climates. Table 1 and 2 shows the material properties of the two types of glass used for simulation. Five different types of shades were selected for the simulation (Table 3). Table 1. Glass type material properties Layers Properties Values Outside Thickness {m} 0.0063 Solar Transmittance at Normal 0.6 0.1 : : ack Side 0.85 : 0.102 Table 2. Glass type material properties Layers Properties Values Outside Thickness {m} 0.0095 Solar Transmittance at Normal 0.381 : 0.338 : 0.468 ack Side 0.662 : 0.255 : 0.211 ack Side IR Transmittance at Normal 0 IR Hemispherical Emissivity: 0.84 IR Hemispherical Emissivity: ack Side 0.051 Conductivity {W/m-K} 1 ir Thickness {m} 0.0127 Inside Thickness {m} 0.0063 Solar Transmittance at Normal 0.381 : 0.338 : 0.468 ack Side 0.662 : 0.255 : 0.211 ack Side IR Transmittance at Normal 0 IR Hemispherical Emissivity: 0.84 IR Hemispherical Emissivity: ack Side 0.051 Conductivity {W/m-K} 1-1694 -

Table 3. Different shade fabric material properties Type Properties Values 1 Solar Transmittance (T-sol) 0.12 Solar Reflectance (R-sol) 0.42 Visible Transmittance (T-vis) 0.1 Visible Reflectance (R-vis) 0.4 Openness (%) 22 Thickness (mm) 1.8 2 Solar Transmittance (T-sol) 0.11 Solar Reflectance (R-sol) 0.38 Visible Transmittance (T-vis) 0.09 Visible Reflectance (R-vis) 0.36 Openness (%) 17 Thickness (mm) 1.7 3 Solar Transmittance (T-sol) 0.11 Solar Reflectance (R-sol) 0.56 Visible Transmittance (T-vis) 0.09 Visible Reflectance (R-vis) 0.54 Openness (%) 11.5 Thickness (mm) 2.3 4 Solar Transmittance (T-sol) 0.11 Solar Reflectance (R-sol) 0.41 Visible Transmittance (T-vis) 0.1 Visible Reflectance (R-vis) 0.4 Openness (%) 11.3 Thickness (mm) 3.6 5 Solar Transmittance (T-sol) 0 Solar Reflectance (R-sol) 0.65 Visible Transmittance (T-vis) 0 Visible Reflectance (R-vis) 0.65 Openness (%) 8.9 Thickness (mm) 1.8 PRMETRIC STUDY ll simulations were based on a non-steady state thermal model conducted for the entire year on an hourly basis. The study utilized EnergyPlus (United States Department of Energy, 2007,1) as a thermal simulation engine. Heat transfer equations of conduction, radiation and convection (between glass and shades) were used, which allow robust thermal performance predictions. The study took into consideration the impact of the outdoor conditions. Indoor heat loads such as lighting, equipment, and occupants were assumed to be constant in order to focus the work on the relative impact of the shades on heat flow. Weather data were based on the Typical Meteorological Year 2 (TMY) weather format. TMY2s are data sets of hourly values of solar radiation and meteorological elements for a 1-year period. n important feature of the shading device thermal model in EnergyPlus is calculating the natural convection airflow between the shading device and the glass. This flow affects the temperature of the shading device and glazing and, for interior shading, is a determinant of the convective heat gain from the shading layer and glazing to the zone air. The airflow model is based on the ISO Standard 15099, Thermal Performance of Windows, Doors and Shading Devices Detailed Calculations (ISO15099, 2001). DISCUSSION These simulations were compared to a reference study simulation (windows with no shades) and expressed as a percentage relative to the reference points. The results are compared based on the average hourly heat surface heat exchange for the entire year. Overall simulation results show that installing shades reduced the heat gain. Covering the window with shades also reduced the heat loss during the night time. The reduction rate of the energy is significant when glass performance is poor (Table 4 and 5). Table 4. Heat Gain [W] (Hourly) Location Glass Shade Heat gain without 765.18 with 605.47 Hot without 405.48 with 356.59 without 756.38 with 596.30 Temperate without 398.31 with 357.27 without 737.72 with 581.48 Cold without 398.31 with 351.49 Table 5. Heat loss [W] (Hourly) Location Glass Shade Heat loss without 82.08 with 67.70 Hot without 18.85 with 18.02 without 114.88 with 99.28 Temperate without 33.13 with 32.12 without 123.53 with 108.95 Cold without 39.29 with 37.97 Reduction 20.87% 12.06% 21.16% 10.30% 21.18% 11.75% Reduction 17.52% 4.39% 13.58% 3.03% 11.80% 3.36% The study shows that, as shades are closer to the glass, heat reduction was increased. maximum 2% reduction can be achieved if a shade is closer to the glass (Table 6). - 1695 -

Table 6. Heat reduction and shade distance Climate Hot Temperate Cold Glass type a b a b a b Shade Reduction distance multiplier Heat Gain Heat loss 0 21% 18% 1 20% 16% 0 12% 4% 1 11% 3% 0 21% 14% 1 20% 13% 0 12% 3% 1 11% 2% 0 21% 12% 1 20% 11% 0 12% 3% 1 10% 3% Shade distance multiplier : Effective area for air flow at the top and bottom of the shade divided by the horizontal area between glass and shade (United States Department of Energy, 2007, 2) SENSITIVITY NLYSIS ased on the previous parametric study, the paper investigated the effect of the glass and shade variables on the energy load. The different properties of both glass and shades were investigated with three different locations. ll the property values were modified one at a time and the ratios of changes from a baseline configuration were analyzed. Table 7 and 8 show the amount of thermal load changes from the baseline configuration in different locations. Table 7. Properties sensitivity (Heat gain) Heat Gain Hot Temperate Cold Glass Solar transmittance and 29.82% 32.98% 34.89% Visible transmittance and 0.00% 0.00% 0.00% IR Hemispherical emissivity -3.18% -3.42% -3.44% Conductivity {W/m-K} 0.02% -0.02% -0.04% Thickness -0.04% 0.03% 0.06% Shade Solar transmittance and 7.00% 7.35% 7.51% Visible transmittance and 0.00% 0.00% 0.00% Thermal hemispherical 1.04% 0.94% 0.85% emissivity and transmittance Thickness {m} -0.05% -0.04% -0.04% Conductivity {W/m-K} 0.03% 0.03% 0.03% ir flow permeability -0.02% -0.02% -0.02% Top opening multiplier -0.42% -0.41% -0.42% Table 8. Properties sensitivity (Heat loss) Heat Loss Hot Temperate Cold Glass Solar transmittance and 28.66% 21.63% 18.20% Visible transmittance and 0.00% 0.00% 0.00% IR Hemispherical emissivity 14.10% 13.02% 12.71% Conductivity {W/m-K} 0.79% 0.74% 0.72% Thickness -1.15% -1.08% -1.06% Shade Solar transmittance and Visible transmittance and Thermal hemispherical emissivity and transmittance 4.94% 3.18% 2.80% 0.00% 0.00% 0.00% 0.53% 0.39% 0.40% Thickness {m} -% -0.05% -0.04% Conductivity {W/m-K} 0.06% 0.04% 0.03% ir flow permeability -0.01% -0.01% -0.01% Top opening multiplier -0.34% -0.24% -0.22% In all location, for the glass properties, the result shows that solar transmittance, solar reflectivity, and infrared (IR) hemispherical emissivity were major variables that affect the heat loads. For the shade properties, solar transmittance, solar, thermal hemispherical emissivity, and thermal hemispherical transmittance were major variables. The conductivity of both the glass and the shade did not show significant change in the different locations. These results made it possible to decide which variables were major contributors to the thermal performance of the shade. Results of the sensitivity analysis gave an in-depth view of which variables were needed more study than other variables, and later it allowed reduction of the input parameters for the neural network. NEURL NETWORK The challenge of utilizing energy simulation to find optimum shades is that manipulating different variables and simulating energy load is time consuming. Therefore, it is necessary to reduce the computer power and simulation time by utilizing prediction algorithms. For that reason, this paper investigates the possibility of utilizing the neural network as a prediction model. The neural networks are non-linear statistical data modelling or decision-making tools. They can be used to model complex relationships between inputs and outputs or to find patterns in data. So once the relationship is established between initial data and - 1696 -

conditions, it is easy to predict any shade s efficiency on the energy load. The neural network model Matlab (MathWorks, 2001) was used for the test. The neural network was coded in a m-file. The training set of inputs and targets are shown in Table 9. There are 160 neurons in the first layer and two neurons in the second (output) layer. The transfer function in the first layer is logsig, and the output layer transfer function is purelin. The log sigmoid transfer function (logsig) takes the input, which may have any value between plus and minus infinity, and squashes the output into the range 0 to 1. The linear transfer function (purelin) is used as an approximation. For the training function, gradient descent with momentum was used. The parameters for training were also customized for the research. Table 9. Neural network training input and output variables. Input Output Location Glass Solar transmittance Solar IR hemispherical emissivity Shade Solar transmittance Solar Thermal hemispherical emissivity Thermal hemispherical transmittance Heat gain[w](hourly) Heat loss[w](hourly) Figure 3. Comparison between energy simulation (EP) and neural network(nnw) prediction (Heat gain) 40 30 20 10 Figure 4. Comparison between energy simulation (EP) and neural network(nnw) prediction (Heat loss) 8 6 4 2 0 0 P-w-1-b-1 P-w-1-b-2 P-w-1-b-3 P-w-1-b-4 P-w-1-b-5 EP NNW P-w-1-a-1 P-w-1-a-2 P-w-1-a-3 P-w-1-a-4 P-w-1-a-5 EP NNW Once the network was trained, ten cases were simulated with neural network. The range of cases is shown in Table 10. Table 10. Neural network test case input variables range # Glass Shade C D E F G H I 1 0.4 0.60 0.09 0.86 0.12 0.42 0.7 0.22 1 2 0.4 0.60 0.09 0.86 0.11 0.38 0.7 0.17 1 3 0.4 0.60 0.09 0.86 0.11 0.56 0.7 0.12 1 4 0.4 0.60 0.09 0.86 0.11 0.41 0.7 0.11 1 5 0.4 0.60 0.09 0.86 0 0.65 0.7 0.09 1 6 0.4 0.38 0.40 0.45 0.12 0.42 0.7 0.22 1 7 0.4 0.38 0.40 0.45 0.11 0.38 0.7 0.17 1 8 0.4 0.38 0.40 0.45 0.11 0.56 0.7 0.12 1 9 0.4 0.38 0.40 0.45 0.11 0.41 0.7 0.11 1 10 0.4 0.38 0.40 0.45 0 0.65 0.7 0.09 1 : Location, : Solar transmittance, C: Solar, D: IR hemispherical emissivity, E: Solar transmittance, F: Solar, G: Thermal hemispherical emissivity H: Thermal hemispherical transmittance, I: Distance multiplier DISCUSSION Comparison between the result of the prediction model and the energy simulation shows the difference within reasonable range of average 9% except the case number 5and 10(Figure 3 and 4). The result shows that in cases when the shades solar transmittance is zero, the difference between the prediction model and the energy simulation result increased compared to other cases. The relation between and transmittance was assumed to be the factor of difference. In the test case even when the transmittance value was zero the value was also low that creates a conflict relationship between the transmittance and the value. CONCLUSION The paper investigated the importance of shades regarding energy saving. The result shows that shades can reduce the energy load, and especially shows that the reduction of the energy load increases when the glass type is poor. This suggested that having shades in low energy performance buildings could benefit energy saving with comparatively low initial investment. The sensitivity analysis result shows that solar and thermal transmittance,, and hemispherical emissivity were major variables that affect the heat loads compared to other variables. The result of the neural network model was within reasonable range. The neural network model gives a - 1697 -

possibility to extend the research to implement the optimization model to find the best shade option for different conditions. The paper illustrated the initial development and further research is needed which include: The different orientation of the windows and its effects on the shades should be included. Even though the energy simulation is able to simulate the air convection between the glass and shades, its algorithm needs further study, which suggests integration with Computational Fluid Dynamics (CFD) to find better Convectional Heat Transfer Coefficient value. The neural network model needs to include relationships not only between transmittance and but also involving absorption of both glass and shades. CKNOWLEDGEMENT This research was partially funded by Lutron Electronics, Inc. REFERENCES aldinelli, G. 2009, Double skin façades for warm climate regions: nalysis of a solution with an integrated movable shading system, uilding and Environment 44 pp1107 1118 The board of trustees of the University of Illinois and The regents of the University of California through the Ernest Orlando Lawrence erkeley National Laboratory. Engineering Reference: The Reference to EnergyPlus Calculations. 2007. (United States Department of Energy, 2007, 1) The board of trustees of the University of Illinois and The regents of the University of California through the Ernest Orlando Lawrence erkeley National Laboratory. Input output reference: The Encyclopaedic Reference to EnergyPlus input and output. 2007. (United States Department of Energy, 2007, 2) Cheung,H.D., and Chung, T.M. 2007, nalyzing sunlight duration and optimum shading using a sky map, uilding and Environment 42 pp3138 3148 Ihm,Pyonchan, Nemri, bderrezek, and Krarti, Moncef. 2009. Estimation of lighting energy savings from daylighting, uilding and Environment 44 pp509 514 Kabre, Chitrarekha. 1999. WINSHDE: computer design tool for solar control, uilding and Environment 34 pp263-274 Laha, M.T. Zupancic,. and Krainer,. 2005. Fuzzy control for the illumination and temperature comfort in a test chamber, uilding and Environment 40 pp1626 1637 Lee, E.S. and Tavil,. 2007, Energy and visual comfort performance of electrochromic windows with overhangs, uilding and Environment 42 pp2439 2449 The MathWorks, Inc. Neural network toolbox for use with Matlab. Massachusetts: The MathWorks, Inc., 2001. Ochoa, Carlos Ernesto and Capeluto, Isaac Guedi. 2009, dvice tool for early design stages of intelligent facades based on energy and visual comfort approach,energy and uildings, rticle in Press. Olgyay, Olgyay V. Solar Control and Shading Devices. Princeton University Press, New Jersey. 1957 Tanaka, H. and et.el. 2008. Thermal characteristics of a double-glazed external wall system with roll screen in cooling season, uilding and Environment, rticle in Press. - 1698 -