VLV49A Series Universal Replacement Gas Valve

Similar documents
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

G670 Intermittent Pilot Ignition Controls

Your safety and the safety of others are very important.

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Operator: Save these instructions for future use!

Your safety and the safety of others are very important.

LPM-06 CONVERSION KIT

OBSOLETE. VS8420 Millivolt Gas Valve

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

S8610U Universal Intermittent Pilot Gas Ignition Control

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

MODEL G300 BRAKE BLEEDER

San josé OWNER S MANUAL

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

PREPIPED LIQUID FUEL MANIFOLDS PLPM

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

Series Hose Reels

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Universal Adjustable Fuel Pressure Regulator

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

orlando OWNER S MANUAL

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

MODEL J SERIES CONVERTER

INSTALLATION INSTRUCTIONS

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

SERVICE MANUAL. Flammable Vapor Ignition Resistant Water Heaters. Gas Water Heaters. Troubleshooting Guide and Instructions for Service

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

DC400 Dispensing Cutoff System

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

CARING FOR YOUR WATER HEATER

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

IOM SERIES 820-E/P Electro-Pneumatic Positioner

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

SV9501/SV9502/SV9601/SV9602 SmartValve TM System Control

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

A99B Series Temperature Sensors

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

STC 3S A Series Solenoid Valves

Time Propane Pressure Drop Test Sign-Off Sheet

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

! WARNING. Before using product, read and understand instructions.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL MODEL RP-150

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

37E73A-903 & 906 INTELLI-VENT

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

AMX300 DirectConnect Mixing Valve Kits

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

TYPE E Main Valve Sizes 3 /8 through 12

Easy Tool Retracting System CMC-SR2159ER36

PARTS NEEDED FOR CONVERTING FROM LP TO NG


VR46../VR86.. series COMPACT AUTOMATIC COMBINATION GAS CONTROLS APPLICATION. Contents PRODUCT HANDBOOK

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

INSTALLATION MANUAL MODEL RP-100

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Electric Water Heater

Installation and Operating Instruction Manual

DBF 4XL Dryer Booster Fans

Watts Pure Water Systems

QT Residential Blower Metal Residential Blower

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.

SunMaxx Solar Filling Station Operating Instructions

12-Volt Negative Ground Installation Instructions

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

INSTALLATION MANUAL GAS COOKTOP. Please read this guide thoroughly before installation. P/No.: MFL

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Float and Thermostatic Traps Series H, C and X

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Model 43AP Pneumatic Controller, Style B

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

SELECTION, APPLICATION AND MAINTENANCE

COMMERCIAL GAS DRYER

Instantaneous gas water heater

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

PRESSURE REDUCING CONTROL VALVE

How To Fix A Car With A Carbide Engine

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

Transcription:

Technical Bulletin VLV Issue Date 0100 VLV49A Series Universal Replacement Gas Valve To Terminal 1 To Terminal 3 To Terminal 5 or Ground Blue Red Black Grommet Screw B Screw A Valve Inlet Pilot Tap Connection Figure 1: Universal Replacement Gas Valve Application The VLV49A Series Universal Replacement Gas Valve is for the replacement of the valve assembly of an electronic proven pilot spark ignition control with a valve (i.e., G60 and Q15). They are combination redundant valves, available with or without a pressure regulator. These valves can be used on appliances burning natural gas, Liquefied Petroleum (LP) gas, manufactured gas, mixed gas or LP gas-air mixtures, including sulfur bearing gases (depending on the regulator selection) at pressures up to 35 mbar (0.5 psi). 2004 BASO Gas Products 1 Part No. 24-8711-455, Rev. www.baso.com

Table 1: Specifications Product Maximum Operating Pressure Ambient Temperature Electrical Rating Regulator Adjustment Range Inlet Pipe Size Outlet Pipe Size Pilot Outlet Wiring Connections Types of Gas Accessories Agency Listings VLV49A Series Universal Replacement Gas Valves 35 mbar (0.5 psi) -40 to 80 C (-40 to 175 F) 24 VAC, 60 Hz, 0.3 ampere draw 7.5 to 15 mbar (3 to 6 in. W.C.) 1/2 in. NPT 3/4 in. NPT 1/8 in.-27 NPT left and right 216 mm (8.5 in.) lead wires Natural, Liquefied Petroleum (LP), manufactured, mixed, and LP gas-air mixtures Conversion Kits Natural gas to LP gas: lever-acting regulator Y71GF-4 direct-acting regulator Y71GF-3 None The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult BASO Gas Products. BASO Gas Products shall not be liable for damages resulting from misapplication or misuse of its products. Table 2: Universal Replacement Gas Valve Chart Valve Part Number Regulator Type Direct-acting regulator Lever-acting regulator No regulator 2 VLV49A Series Universal Replacement Gas Valve Technical Bulletin

Table 3: Replacement Valve Selection Chart Original Valve/Ignition Part Number Replacement Valve Part Number G60CAA-1, 3 G60CAG-1, 2, 3, 4, 6, 7, 8 G60CAG-9 G60CBA-1, 3 G60CBG-1, 3, 4, 9, 10, 11, 14, 16, 17 G60CCA-1 G60CCG-1 G60CPG-1 G60DBG-1 G60DCG-1, 2, 4 G60QAG-1, 2, 3 G60QAG-1 G60QAK-1 G60QBG-1, 2, 3, 4, 5, 6, 7, 8, 9 G60QBH-1 G60QBK-1 G60QBK-3 G60QBL-1 G60QCG-1 G60QCL-1 G60QCJ-1 G60QDG-1 G60QFL-1 G60QHL-1, 2 G60QJL-1 G60QLG-1 G60QPL-1 G60QRH-1 G60QRL-1, 2, 3 G60QSL-1 G60QTH-1 G60QTL-1 G60QUL-1 G60RAG-1 G60RBG-1, 2 G60RBG-3 G60RBK-1, 2 G60RCG-2 G60RCJ-1 G60RDG-1 G60RDK-1 G60RGL-1 G60RHL-1 Continued on next page... * * * * plus Y71GF-4 plus Y71GF-4 plus Y71GF-4 plus Y71GF-4 plus Y71GF-3 VLV34A-648R VLV49A Series Universal Replacement Gas Valve Technical Bulletin 3

Original Valve/Ignition Part Number (Cont.) G60RHP-1 G60RPL-1 G60RSL-1 VLV34A-605 VLV34A-608 VLV34A-609 VLV34A-610 VLV34A-613 VLV34A-614 VLV34A-617 VLV34A-621 VLV34A-623 VLV34A-624 VLV34A-625 VLV34A-626 VLV34A-628 VLV34A-633 VLV34A-636 VLV34A-637 VLV34A-638 VLV34A-639 VLV34A-640 VLV34A-641 VLV34A-642 VLV34A-643 VLV34A-644 VLV34A-645 VLV34A-648 VLV37A-602 VLV37A-603 VLV41A-600 VLV41A-601 VLV41A-602 VLV41A-605 VLV43A-600 VLV43A-601 VLV43A-602 VLV43A-603 VLV43A-604 VLV43A-605 VLV43A-606 VLV43A-607 VLV43A-608 VLV43A-612 Continued on next page... Replacement Valve Part Number plus Y71GF-4 plus Y71GF-3 VLV34A-648R 4 VLV49A Series Universal Replacement Gas Valve Technical Bulletin

Original Valve/Ignition Part Number (Cont.) VLV43A-609 VLV43A-610 VLV43A-615 VLV43A-616 VLV44A-600 VLV44A-601 VLV49A-604R VLV49A-605R VLV49A-606R G96JGA-3 (Q15HAA-1) Replacement Valve Part Number plus Y71GF-3 plus Y71GF-4 * 24 VAC replacement gas valve for original 120 VAC valve. A 24 VAC transformer is required. Note: All replacement valves come set up for use with natural gas. If used on an LP system, the appropriate Y71 conversion kit must be installed. Y71GF-3 Natural to LP for direct-acting regulators Y71GF-4 Natural to LP for lever-acting regulators VLV49A Series Universal Replacement Gas Valve Technical Bulletin 5

Installation IMPORTANT: This technical bulletin is intended as a guide for authorized service personnel installing or servicing BASO Gas products. Carefully follow all instructions in this bulletin and all instructions on the appliance. Limit repairs, adjustments, and servicing to the operations listed in this bulletin or on the appliance.! WARNING: Fire or Explosion Hazard. The system must meet all applicable codes. Improper installation may cause gas leaks, explosions, property damage, and injuries.! WARNING: Fire or Explosion Hazard. To prevent leakage of upstream gas, shut off the gas supply at the main manual shutoff valve before installing or servicing the VLV valve.! CAUTION: Equipment Damage Hazard. To prevent damage to the valve when mounting to the manifold, do not use a wrench on any surface other than the casting flats provided at the inlet and outlet ends of the valve body.! CAUTION: Equipment Damage Hazard. Label all wires prior to disconnection when replacing the valve. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Perform the following procedure to install the replacement VLV49A valve. 1. Turn off power to the appliance. 2. Turn off the gas at the manual shutoff valve adjacent to the appliance. (If the manual shutoff valve services more than one appliance, be sure to light the other pilots before leaving.) 3. With the gas and power to the appliance turned off, disconnect the power supply (transformer) and the thermostat lead wire at the ignition control. 6 VLV49A Series Universal Replacement Gas Valve Technical Bulletin

4. Disconnect the sensing probe lead from Terminal 4 on the ignition control. 5. Disconnect the high voltage cable from the spark transformer. 6. Disconnect the Pilot Valve 1 and Main Valve 3 leads from the terminal board or end plug-in Heyco terminals (see Figures 2 and 3). Terminal Board Connections Ground Terminals Figure 2: Terminal Board Ignition Control with Mounting Plate Ground Terminals Heyco Terminal Connections Figure 3: Plug-in Heyco Ignition Control VLV49A Series Universal Replacement Gas Valve Technical Bulletin 7

7. Remove Screws A and B holding the ignition control assembly to the valve and plate assembly (see Figure 1). These two screws are located on the bottom surface of the ignition control assembly. 8. Remove the ignition control. 9. Disconnect the pilot burner tubing from the pilot tap connection on the gas valve (see Figure 1). 10. Verify (when looking on the inlet of the valve) that the location of the grommet and wire leads on the old valve and new replacement valve are on the same side. If they are not on the same side, remove the grommet of the new replacement valve and insert it into the other side of the mounting plate (see Figure 4). This allows the placement of the ignition control spark transformer over the outlet of the valve instead of the inlet. Remove grommet and wires from here. Removable Portion of Mounting Plate Removable Portion of Mounting Plate Replace grommet and wires here. Figure 4: Grommet Locations 11. Remove the old valve from the manifold and install the new replacement valve. Ensure the gas flows through the valve body in the direction indicated by the arrow on the valve body. If the valve is installed with the gas flow opposite the arrow, leakage can occur. A thread lubricant has been factory applied to the first two or three threads of the valve inlet and outlet to avoid galling. Use an approved pipe-joint sealing compound on male threads before assembling. Take care that excess compound does not work into the valve and get onto the valve seats. Threads of pipe and nipples must be smooth and free of tears and burrs. 12. Reconnect the pilot burner tubing at the pilot tap connection. 13. Fasten the ignition control assembly to the valve and plate assembly with the screws provided with the replacement valve. 14. Break off the portion of the plate that protrudes if it interferes with surrounding surfaces (see Figure 4). 8 VLV49A Series Universal Replacement Gas Valve Technical Bulletin

15. Reconnect the thermostat leads, the sensing probe lead, and the high voltage cable according to the labels on the wires. Do not connect the electrical supply at this time. a. On grounded versions (part numbers ending with the letters H, L, G, or J [e.g., G60QBG or G60QBJ]), connect the black lead wire to one of the ground terminals on the ignition control. Four ground spade terminals are located just below the terminal board on terminal board models (see Figure 2) or in a square arrangement on the end of the plug-in Heyco models (see Figure 3). On ungrounded versions (part numbers ending with a K [e.g., G60QBK]), connect the black lead wire to Terminal 5 on the ignition control. On systems using G600 ignition controls, connect the black lead wire to a ground terminal on the ignition control. b. Connect the blue lead wire to Terminal 1 on the ignition control. IMPORTANT: To permit verification of pilot operation, do not connect the red lead wire to any terminal at this time. 16. Check for leakage. a. Open the pressure connection between the manual shutoff valve and the VLV valve. b. Connect air tubing with a maximum pressure of 1-1/2 times the valve s maximum operating pressure (as indicated on the valve) to the opened pressure connection. c. Paint all valve body connections with a rich soap and water solution. If bubbles occur, this is an indication of a leak. To stop a leak, tighten joints and connections. Replace the part if the leak cannot be stopped. If bubbles do not occur, remove the air tubing and close the pressure connection. VLV49A Series Universal Replacement Gas Valve Technical Bulletin 9

17. After installation of the replacement valve is complete, except for the attachment of the red lead wire, turn on the gas at the manual shutoff valve. a. Reconnect the power supply lead wire to the ignition control and turn the power On. b. Set the thermostat to the highest setting. The pilot valve will open, spark will be energized, and the pilot will light. c. Test for gas leaks in the pilot line with a soap solution. d. After the check is complete, turn off the power and connect the red lead wire to Terminal 3 on the ignition control. 18. Turn on the power and set the thermostat to the desired setting. 10 VLV49A Series Universal Replacement Gas Valve Technical Bulletin

Regulator Adjustment IMPORTANT: All adjustments must be made in conjunction with the gas appliance and in accordance with the appliance manufacturer s instruction. Only authorized personnel should make adjustments.! WARNING: Explosion Hazard. The minimum flow rate of the valve must not be adjusted below the minimum safe working rate of the appliance. The pressure regulator is adjustable and has been factory set. If a different setting is desired, follow these instructions. 1. Shut off all gas to the appliance. 2. Turn the thermostat to the lowest setting or Off position. 3. Remove the pressure tap plug at the valve outlet or in the manifold pipe downstream of the valve. 4. Install a manometer or pressure gauge suitable for measuring the desired orifice pressure. 5. Remove the seal screw at the end of the regulator stack. 6. Turn the gas on and place the thermostat at the highest setting to cycle the ignition system. 7. Allow the system to stabilize. Adjust the screw in the regulator stack to the desired reading on the manometer. (Turn clockwise to increase the outlet pressure and counterclockwise to reduce the outlet pressure.) 8. Reinstall the seal screw, which incorporates the proper size hole for venting to the atmosphere. (It may be necessary to cycle the valve several times to verify the desired outlet pressure.) 9. Turn off the gas supply and place the thermostat at the lowest setting. 10. Remove the pressure manometer and reinstall the pressure tap plug. 11. Turn the gas on and set the thermostat to the desired setting. 12. Check for leaks at the pressure tap plug with a soap solution before leaving the site. VLV49A Series Universal Replacement Gas Valve Technical Bulletin 11

Checkout Procedure! WARNING: Fire or Explosion Hazard. Avoid personal injury or property damage by making sure the valve functions properly and there are no gas leaks. Follow this checkout procedure before leaving the installation. Make sure all components are functioning properly by performing the following test: 1. Test for leaks on all pipe joints and connections upstream of the gas valve with a soap solution. 2. Turn the thermostat to a low setting. 3. Turn on the gas and purge the gas lines of all air. 4. Turn the thermostat to a high setting. The appliance should operate in accordance with the manufacturer s specified sequence of operation. 5. Test for leaks on all pipe joints and connections downstream of the gas valve with a soap solution. 6. Turn the thermostat down for at least 30 seconds and then back up again. Verify successful ignition at least three times before leaving the installation. Repairs and Replacement The VLV49A replacement valves are not field repairable. Do not attempt field repairs. For a replacement valve, contact the nearest BASO Gas Products distributor. 1007 South 12th Street PO Box 170 Watertown, WI 53094 www.baso.com 1-877-227-6427 (1-877-BASOGAS) Printed in U.S.A. 12 VLV49A Series Universal Replacement Gas Valve Technical Bulletin