Electronic Circuit Breaker with reset input ESS20-1..

Similar documents
Safety technique. Emergency stop module BO 5988 safemaster

Thermal-Magnetic Circuit Breaker M1-..

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Product and functional description

48 SERIES Relay interface modules 10 A

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

E-STOP relays, safety gate monitors

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Electronic overload relay EF19 and EF45

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

49 Series - Relay interface modules A. Features

38 Series - Relay interface modules A

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

MasterINTERFACE 39 Series - Relay interface modules

PNOZsigma - Base units

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Three-phase monitoring relay CM-PFE

Electronic overload relay EF65, EF96 and EF146

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

38 Series - Relay interface modules A

MasterINTERFACE 39 Series - Relay interface modules

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Quick Connect. quick - simple - efficient.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Cable Plug acc. to DIN EN , Form A

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Solid State Remote Power Controllers (SSRPCs)

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Circuit Breakers. NRC Series. NRC Series

E-STOP relays, safety gate monitors

R.C.C.B. s two-pole LEXIC

E-STOP relays, safety gate monitors

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Redundancy Module QUINT-DIODE/40

Type: DILM50(230V50HZ,240V60HZ) Article No.:

40 Series - Miniature PCB/Plug-in relays A. Features

Pluggable interface relays CR-P Pcb relays

DMX2PWM 9 Channel Dimmer Setup Manual

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

80 Series - Modular timers 16 A. Features

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

MINI MCR-SL-R-UI(-SP)

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

HERZ-Thermal Actuators

is then retained absolutely without interruption.

SYSTEM DESCRIPTION Termination Boards

Type: DILM32 10(24V50HZ) Article No.:

Contact expansion modules

Contact expander modules

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

RM4TG20 three-phase network control relay RM4-T - range V

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Safety automation solutions

PHOENIX CONTACT Features

Modular I/O System Analog and Digital Interface Modules

Power Supplies 3. SDN-P DIN Rail Series

Digital input modules

Bimetallic Overload Relay Specifications

CQM1-SF200/CS1W-SF200

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Thermistor motor protection

Digital Pressure Measuring Instrument MDR480

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

ACS-30-EU-EMDR-10-MOD

60 Series - General purpose relays 6-10 A. Features

Type: DILM9 10(24VDC) Article No.:

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Safety Relays ESM/ESM-F

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

E-STOP relays, safety gate monitors

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

13 SERIES. Electronic step relays A

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

Control Devices Catalogue. Control Devices. Preferred and Standard Products

5SV Residual Current Protective Devices

Transcription:

Electronic Circuit Breaker with reset input ESS20-1.. Description The special device ESS20-1.. is a further extension of the product line electronic circuit breakers. Type ESS20-1.. has a width of only 12.5 mm and selectively protects all DC 24 V loads through a combination of active electronic current limitation and well-proven circuit breaker technology including physical isolation and manual actuation. The ESS20-1.. can be plugged into the E-T-A power distribution socket Module 17plus, ensuring ease of installation and a significant reduction of wiring time. DC 24 V switch-mode power supplies, which are widely used in automation industry today, will shut down the output in the event of an overload with the result that one faulty load in the system can lead to complete disconnection of all loads. The ESS20-1.. helps to overcome this problem as it responds to the overload condition faster than the switch-mode power supply. The highest possible overcurrent is limited to 1.8 times rated current. Thus it is still possible to switch on capacitive loads and they are disconnected only in the event of an overload or short circuit. For optimal adjustment to the application conditions the current rating of the ESS20-1.. can be selected by means of a switch (3 A or A). Failure and status indication are provided by a bicolour LED and an integral short-circuit proof signal output. Upon detection of overload or short circuit in the load circuit the MOET of the load output will be blocked and current flow in the load circuit will be interrupted. MOET and load circuit may be reset by means of the electronic reset input or manually by actuating the push-button (PUSH-PUSH operation). The load circuit may also be physically isolated during start-up of the equipment, e.g. for measuring purposes. Features Selective load protection Electronic disconnection in the event of an overload of 1.1 times rated current plus (without physical isolation) Active current limitation (typically 1.8 times rated current) during switch-on of capacitive loads and in the event of overload or short circuit One unit for two current ratings: 3 A and A (selectable) Manual ON/OFF button (push-push actuation) with physical isolation Clear status and failure indication through LED and signal output Electronic reset input Integral fail-safe element Width per unit only 12.5 mm Plug-in mounting utilising power distribution system Module 17 plus Approvals UL 1077 NEW ESS20-1.. Technical Data (T U = 25 C, U B = DC 24 V) (T U = ambient temperature at U N ) Operating data Operating voltage U B DC 24 V (18... 32 V) Current rating I N 3 A or A (selected by means of a switch) Closed circuit current I 0 typically 22 ma Status indication bicolour LED: by means of GEN: unit is ON, load circuit/power- MOET is switched on, signal output on, supplying +DC 24 V ORANGE: in the event of overload or short circuit until electronic disconnection D: unit switched off electronically, load circuit/power MOET off, status output blocked, undervoltage (U B <8 V), after switch-on until end of switch-on delay. OFF: switched off manually with pushbutton, unit off load signal output : - 1 signalisation per channel - load ON = +DC 24 V - load OFF = 0 V ON/OFF position of push button Load circuit Load output power MOET switching output (plus switching) Current rating range I N 3 A or A (selectable by means of a switch) Max. data of load DC 24 V / A for resistive, inductive, (cont. duty) capacitive load, lamp load with side-by-side mounting A at T U = 40 C and 100 % ON duty 5 A at T U = 50 C and 100 % ON duty Voltage drop at I N typically 0 mv / 3 A typically 280 mv / A Disconnection at overload typically 1.1 x I N Short circuit current I K typically 1.8 x I N / active current limitation Trip time see time/current characteristics for physical isolation typically 3 s at I load > 1.1 x I N for electronic disconnection typically 3 s...100 ms at I load > 1.8 x I N Temperature disconnection internal temperature monitoring with electronic disconnection Low voltage monitoring Load output Starting delay t start Physical isolation ON at U B > 1V OFF at U B < 8V typically 0.5 sec after every switch-on and after applying U B single pole (switch contact) of load circuit - by push-push actuation of the blue push button 04/05 Phone: Germany (0 91 87) 10-0 - USA (847) 827-700 - UK (0129) 42033 - www.e-t-a.com 21

Electronic Circuit Breaker with reset input ESS20-1.. Technical Data (T U = 25 C, U B = DC 24 V) (T U = ambient temperature at U N ) Free-wheeling circuit Signal output Signal output Signal output ON Signal output OFF Reset input Reset input (terminal 13 or of module 17plus) Reset input level: voltage high low current consumption min. pulse length General data Ambient temperature external free-wheeling diode recommended with inductive load plus-switching signal output per unit, applies U B to terminal 12 of module 17plus Ratings: DC 24 V / max. 0.5 A (shortcircuit proof) signal output has +24 V level if - the load output has continuity (ON condition of load) signal output has 0 V level if - the load output is electronically blocked (fault condition or switch-on delay) - the blue push button is in OFF position - no operating voltage U B is connected. The signal output is connected to ground via a pull-down resistor (10 kohm). The electronically blocked ESS20-1.. may e.g. be reset via an external momentary switch due to the falling edge of a short +DC 24 V impulse. The reset signal will be fed in terminal 13 or of the module 17plus and is internally pre-wired. The reset simultaneously affects all blocked ESS20-1.. channels of the power distribution system, all switched on ESS20-1.. channels remain unaffected. max. +DC 32 V > DC 8 V... DC 32 V < DC 3 V... 0 V at +DC 24 V typ. 2. ma 10 ms 0...+50 C (without moisture condensation, cf. EN 0204-1) Storage temperature -20...+70 C Fail-safe element back-up fuse for ESS21 not required as it has an integral redundant fail-safe element (thermal E-T-A circuit breaker); push button in OFF position with tripped fail-safe element Blade terminals.3 mm to DIN 4244-A, 3-0.8 Housing material plastics Mounting plug-in type for E-T-A power distribution socket Module 17plus Vibration 3 g, test to IEC 8-2- test Fc Protection class housing IP30 DIN 40050, terminals IP00 DIN 40050 EMC requirements emitted interference: EN 50081-1 (EMC directive, CE logo) immunity: EN 1000--2 Insulation co-ordination 0.5 kv/2 (IEC 0934) re-inforced insulation in operating area Dielectric strength (see dimensions) operating area test voltage AC 1000 V installation area test voltage AC 500 V Insulation resistance >100 MΩ (DC 500 V) between (OFF condition of push button) [LINE ] Approvals Dimensions (B x H x T) Mass UL 1077 under preparation 12.5 x 105 x 0 mm 5 g Ordering information Type ESS20 Basic circuit diagram ESS20-124- LINE DC 24 V ON / OFF Electronic Circuit Breaker with current limitation (e.g. typically 1.8 times rated current) Version 1 without physical isolation in the event of a failure Control input 2 with reset input Signal output 0 without signal contact 4 status output (single signalisation, plus switching) Operating voltage DC 24 V rated voltage DC 24 V Current rating 3 A/ A selectable (switch) 1 A/2 A upon request ESS20-1 2 4 - DC 24 V -3 A/ A ordering example (recommended type) status green / orange / red rated current I N 3 A A reset inputs R sense signal output load output activation short circuit / overload current measurement electronic control unit 22 Phone: Germany (0 91 87) 10-0 - USA (847) 827-700 - UK (0129) 42033 - www.e-t-a.com 04/05

Electronic Circuit Breaker with reset input ESS20-1.. Time/Current characteristic curve 10000 disconnection typ. 1.1 x I N 1.8 x I N 1000 trip time in seconds 100 10 3 1 0.1 current limitation typ. 1.8 x I N short circuit disconnection typ. 100 ms 0.01 0 1 2 3 4 5 IK times rated current The trip time is typically 3 s in the range between 3 s. Electronic current limitation starts at 1.8 x I N which means that under all overload conditions (independent of the power supply and the resistance of the load circuit) the max. overload until disconnection will not exceed 1.8 times the current rating. Trip time depends on extent of overcurrent. In the event of an overload of 1.8 x I N plus the trip time will be up to 3 s, in the event of a short circuit it will be 100 ms. Without current limitation to typ. 1.8 x I N a much higher overcurrent would occur in the event of overload or short circuit. Terminal wiring diagram ESS20-124 Dimensions ESS20-124- 0 2.3 20.8.819 8.5.335 operating area Elektronischer Schutzschalter Electronic Supplementary Protector ESS20 124-DC 24 V-3 A/ A GERMANY 102 ON 4.02 105 OFF 4.13 mounting area LINE 17 10.3.40.9.8.583.8.28 x.8 = 40.8 x.28 = 1.1 50 1.97 29.2 1.15 A reverse plug-in protection blade terminals DIN 4244-.3-0.8 12.2.480 A A A 12.5 12.5.492.492 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. This is a metric design and millimeter dimensions take precedence ( mm ) inch 04/05 Phone: Germany (0 91 87) 10-0 - USA (847) 827-700 - UK (0129) 42033 - www.e-t-a.com 23

ESS20-1 - Accessories: Module 17plus Accessories for ESS20-1.. Description Technical data Module 17plus is a power distribution system for use with electronic circuit breaker ESS20-1.. Each module accommodates two breakers with an individual housing width of only 12.5 mm and fits onto all industry standard mounting rails. The two-way modules can be interconnected to provide as many ways as required with a terminal block fitted at each end for connection of signalling circuits. A distribution busbar can be fitted on the supply side of the modules (positive pole) though each pole of multipole circuit breakers must be individually connected. Electrical connections are by means of spring-loaded terminals. The reference potential for the ESS20-1.. (GND pin ) is also looped through and connected to the terminals at the sides. The integral signal output of the ESS20-124 may be picked off at terminal 12 of the corresponding channel (single signalisation). The reset input may be connected via terminal 13 or. Connection LINE feed (1) output (2) Reference potential GND/ group signal terminals ( or 13, ): individual signal terminal (12) Spring-loaded terminals for solid conductors and stranded cables with and without wire end ferrules. Please use appropriate screw driver size (SD) for removing the spring loaded terminals. spring-loaded terminals for 0.5- mm 2 (AWG 10), SD 2 (0.8x4.0) spring-loaded terminals for 0.25-4 mm 2 (AWG 12), SD 1 (0.x3.5) spring-loaded terminals for 0.25-2.5 mm 2 (AWG ), SD 1 (0.x3.5) spring-loaded terminal for 0.25-1.5 mm 2 (AWG 1), SD 0 (0.4x2.5) Test probe for testing the group signal for line interruption: 2 mm ø Voltage rating (without ESS20-1..): AC 433 V; DC 5 V Current rating (without ESS20-1..) LINE feed (1) 50 A output (2) 25 A Reference potential GND () 10 A Individual signal (12) 1 A (with ESS20-1..: 0.5 A) Group signal /(13-) 1 A (with ESS20-1..: 0.5 A) Internal resistance values (without ESS20-1..) LINE- (1-2) 5 mω Group signal (13-) per module 8 mω per pole +5 mω for each additional module Busbar for power distribution insulated busbar (blue or red): I max 32 A non-insulated busbar: I max 50 A (The non-insulated busbar, too, meets brush contact safety standards when fitted.) Dielectric strength of Module 17plus (without ESS20-1..) between main circuits (without busbar): 1,500 V main circuit to auxiliary circuit: 1,500 V between auxiliary circuits: 1,500 V Mass: Module 17plus (centre piece) approx. 85 g terminal blocks (pair) approx. 30 g Ordering information 17PLUS-Q02-00 17PLUS-QA0-LR Module 17plus, centre piece, two-way one each left- and right-side terminal block for supply feed from the side by means of screw terminal Pin configuration, fitted with ESS20-1.. ESS20-124 Module 17 plus LINE (1) Gnd () (13) () (12) (2) operating voltage PLUS, DC 24 V operating voltage MINUS reset input reset input signal output protected load output 24 Phone: Germany (0 91 87) 10-0 - USA (847) 827-700 - UK (0129) 42033 - www.e-t-a.com 04/05

ESS20-1 - Accessories: Module 17plus Dimensions Installation example slot for fitting labels from Phoenix ZB, RBS, DST Weidmüller dekafix, BS, PES Wieland Type 9003 Elektronischer Schutzschalter Electronic Supplementary Protector ESS20 124-DC 24 V-3 A/ A LINE 102 (105) 4.01 (4.13) LINE Elektronischer Schutzschalter Electronic Supplementary Protector ESS20 124-DC 24 V-3 A/ A 2 2 4 47 1.85 42.5 1.7 17 plus 57 2.24 5 12 2 12 2 3 2.48 slot for busbar 1 Line 1 Line module 5 4.53 G-profile EN 50035-G32 symmetrical rail EN 50022-35x7.5 12 12 25 25.23.984.984 37 1.4 right-side terminal block left-side terminal block This is a metric design and millimeter dimensions take precedence ( mm ) inch 3 Modul 17 plus GERMANY 13 1 12 2 12 2 Installation: 1 Clip modules onto DIN rails. 2 Push modules together (side-by-side). 3 Snap on right-side and left-side terminal blocks. 4 Cut busbar to required length and fit on supply side of the modules. 5 Connect line feed with spring-loaded terminals. Plug in ESS20-1... 2 3 Connection diagram pour ESS20-124 module 1 module 2 side busbar busbar Gnd Gnd >i >i >i 13 2 12 2 12 2 12 2 12 ESS20-124 jumper left-side terminal block right-side terminal block Gnd 12 terminal for signalisation (+DC 24 V) 13, reset input 04/05 Phone: Germany (0 91 87) 10-0 - USA (847) 827-700 - UK (0129) 42033 - www.e-t-a.com 25

ESS20-1.. - Accessories: Module 17plus Accessories Busbar 32 A X 222 005 01 blue insulation, 500 mm/19.8 in. X 222 005 02 red insulation, 500 mm/19.8 in. X 222 005 03 grey insulation, 500 mm/19.8 in. Busbar 50 A Y 307 01 01 non-insulated, 500 mm/19.8 in. Busbar 50 A for busbar connection by means of terminal 17plus-QA0-LR Y 307 01 non-insulated, 500 mm/19.8 in. End bracket X 222 004 01 Screw terminal for busbar X 2 15 01 non insulated Jumper X 222 0 01 10 51.394 2.01 40.8 1.1 blade terminals DIN 4244-A.3-0.8 (QC.250) SIGNALBRÜCKE X 222 0 01.5.453 50 1.97 This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 2 Phone: Germany (0 91 87) 10-0 - USA (847) 827-700 - UK (0129) 42033 - www.e-t-a.com 04/05