J. Automation & Systems Engineering 9-3 (2015): K.P. Satheyamoorthy. University of M. G. R. Educational and Research Institute, India

Similar documents
New Supervisory Control and Data Acquisition (SCADA) Based Fault Isolation System for Low Voltage Distribution Systems

Permissible ambient temperature Operation Storage, transport

Gsm Based Controlled Switching Circuit Between Supply Mains and Captive Power Plant

Design and Development of SMS Based Wireless Home Appliance Control and Security System

Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)

PLC Based Liquid Filling and Mixing

An overview of Computerised Numeric Control (C.N.C.) and Programmable Logic Control (P.L.C.) in machine automation

Programming Logic controllers

Intelligent Home Automation and Security System

Semaphore T BOX Applications in Data Center Facilities

International Journal of Advancements in Research & Technology, Volume 3, Issue 5, May ISSN THROUGH MOBILE

ANYTIME ANYPLACE-REMOTE MONITORING OF STUDENTS ATTENDANCE BASED ON RFID AND GSM NETWORK

SMS GSM Alarm Messenger

ARCHITECTURE OF INDUSTRIAL AUTOMATION SYSTEMS

Programmable Logic Controllers

REAL-TIME MONITORING AND ASSESSMENT OF CIRCUIT BREAKER OPERATIONS FOR DIAGNOSTICS AND CONTROL APPLICATIONS

GSM ATT Modules Simply effective remote control

German Cathodic Protection REMOTE MONITORING AND CONTROL

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

Industrial IT for Substation Automation & Protection

Design of Strong-motion Monitoring System for Dam-reservoir D s e i s gn of Stro r ng-mo m tion Monito t ri r ng Syst s em

A Proposed Integration of Hierarchical Mobile IP based Networks in SCADA Systems

Process Control and Automation using Modbus Protocol

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Distribution System Automation

Design of Wireless Home automation and security system using PIC Microcontroller

THE INPUT/OUTPUT SYSTEM. Key Points

Study on Differential Protection of Transmission Line Using Wireless Communication

Autonomous Advertising Mobile Robot for Exhibitions, Developed at BMF

Real-time Video Monitoring Increases the Efficiency of SCADA Process Management

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Section TELEPHONE AUTOMATIC DIALER SYSTEM

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Substation Automation Systems. Nicholas Honeth

GPS & GSM BASED REAL-TIME VEHICLE TRACKING SYSTEM.

Smart Thermostat page 1

Natural Gas Well Automation using Kingfisher RTU Products

Substation Automation and Smart Grid

IEEE Projects in Embedded Sys VLSI DSP DIP Inst MATLAB Electrical Android

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

EMBEDDED GSM MONITOR AND CONTROL USING ANDROID APPLICATION

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Implementation of a New Substation Restoration System Using Protective Relays and a Logic Processor

REQUIREMENTS FOR AUTOMATED FAULT AND DISTURBANCE DATA ANALYSIS

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

Design and Development of SMS Based Wireless Home Appliance Control and Security System

Introduction To SCADA and Telemetry

Room Temperature based Fan Speed Control System using Pulse Width Modulation Technique

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Monitoring & Control of Small-scale Renewable Energy Sources

Implementation of Knock Based Security System

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

AutoLog ControlMan. Remote Monitoring & Controlling Service

Automated Profile Vehicle Using GSM Modem, GPS and Media Processor DM642

ABB PSPS Erich Steinmann; Generator control-2013

Telemetry system for cathodic protection equipment of underground metal pipelines

Control of Boiler Operation using PLC SCADA

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Remote Operations of SCADA Systems using InduSoft

Sensor network infrastructure for intelligent building monitoring and management system

Reduce the cost of communication with ComAp. Telecom tower solutions

Disturbance Recoder SPCR 8C27. Product Guide

Voltage Regulator SPAU 341 C. Product Guide

Considerations When Specifying a DC Power Supply

Web SCADA Employing Application Program Interface as Data Source

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

White Paper. Technical Capabilities of the DF1 Half-Duplex Protocol

Protection and Substation Automation. Training Programmes

Substation Automation based on IEC 61850

Delta Transportation Automation Solution.

Complete SCADA solution for Remote Monitoring and Control

Temperature & Humidity SMS Alert Controller

MICROCONTROLLER BASED SMART HOME WITH SECURITY USING GSM TECHNOLOGY

Design of UPS Battery Remote Monitoring System

Programming A PLC. Standard Instructions

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Understanding Mechatronics Engineering Using a School Project

Design and Implementation of SCADA System Based Power Distribution for Primary Substation (Control System)

Remote PLC system using GSM network with application to home security system

AUTOMATIC FIREFIGHTING SYSTEM USING PLC

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

The Shift to Wireless Data Communication

Power Feeding Equipment for Optical Submarine Cable Systems

Automatic Ration Material Distributions and Payment System Based on GSM and RFID Technology

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Configuring PROFINET

Power over Ethernet technology for industrial Ethernet networks

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

NC-12 Modbus Application

GSM Based Electrical Control System for Smart Home Application

Development of an Internet based Embedded System for Smart House Controlling and Monitoring

Square D Model 6 Motor Control Centers

Transcription:

Regular paper Role of Controlling of Substation Using PLC And SCADA K.P. Satheyamoorthy University of M. G. R. Educational and Research Institute, India Abstract- An electrical substation is a subsidiary station of an electricity generation, transmission and distribution system. In electrical network there are always possibilities of faults. Hence the current and voltage to a substation require regular monitoring and control. This project proposes a novel solution to both the above requirements. In this project a SCADA systems will be designed using RS VIEW 32, using which all the parameters of a substation like current, voltage, temperature and flow of coolants in transformers etc can be monitored and automatically controlled from a distant location. These are connected to a PLC at the substation. Keywords: SCADA, PLC, substation. 1. INTRODUCTION This paper presents a sub-station automation system as an integrated system for the digital and analog automation of distribution sub-station, customers and user functions (engineers & technicians). Faults caused by over-current, earth leakage current and other disturbances create interruptions of electricity supply to the customers. The engineers and technicians have to manually locate the fault point and spend plenty of time and this tedious work may last for extend periods of time. After the introduction of fault management, the fault is detected by energizing section by section of distribution line until the protective relay trips the feeding circuit breaker of the fault zone. These operations are mostly based on manual and automatic operations. The advent of PLC and the introduction of numerical relays have improved the function of fault management system. Now it is possible to record the fault currents at the feeding distribution substations and the restoration process is also done automatically and is accelerated faster. 1.1 Programmable logic controller (PLC) PLC or Programmable Logic Controller is a user friendly, microprocessor specialized computer that carries out control functions of many types and levels of complexity. Its purpose is to monitor crucial process parameters and adjust process operations accordingly. It can be programmed, controlled and operated by a person unskilled in operating computers. Essentially, a PLC's operator draws the lines and devices of ladder diagrams with a keyboard onto a display screen. The resulting drawing is converted into computer machine language and run as a user began in the 1970s, and has become the most common choice for manufacturing controls. Programmable Logic program.plc will operate any system that has output devices that go on and off (Discrete, or Digital, outputs). It can also operate any system with variable (analog) outputs. The Control engineering has evolved over time. In the past humans A was the main method for controlling a system. More recently electricity has been used for control and early electrical control was based on Copyright JASE 2015 on-line: jase.esrgroups.org

relays. These relays allow power to be switched on and off without a mechanical switch. It is common to use relays to make simple logical control decisions. The development of low cost computer has brought the most recent revolution, the Programmable Logic Controller (PLC). The advent of the PLC Control can be operated on the input side by ON/OFF devices or by variable (analog) input devices. The ubiquitous Programmable Logic Controllers (PLC) is now finding several applications in the management of assets in a substation. As most electrical equipment lend themselves to embedded devices acting as intelligent interfaces, PLCs are used in the substation to manage transformers, voltage regulation, automatic transfer schemes, custom/automatic reclosing schemes, automatic service restoration, remote control, system diagnostics maintenance ` Field input Field output Push button Power supply sensors switch Push button I N P U T User memory CPU Data memory O U T P U T Serial port Programming device Fig. 1: Internal Block Diagram of PLC 1.2 Supervisory control and data acquisition (SCADA) In recent years, the supervisory control and data acquisition (SCADA) system has been widely used in power system for power parameters recording, monitoring and switches control. The function of SCADA in power system application composes the recording and analysing of power measurements, operating status monitoring, and the execution of control action of switched equipment and load. In general, SCADA system consists of host in control station, communication network, and remote terminal unit in hardware as well as data base, control software, and application programs for software. With the advancement of programmable logic controller in communication and analog data treatment technology, more PLC based control systems are applied to power system to fulfil major functions of load control, on load transformer tab setting, data collection etc. in SCADA system. Supervisory Control and Data Acquisition systems are computers, controllers, instruments; actuators, networks and interfaces that manage the control of automated industrial processes and allow analysis of those systems through data collection. They are used in all types of industries, from electrical distribution systems, to food processing, to facility 195

K.P. Satheyamoorthy : Role of Controlling of Substation Using PLC And SCADA security alarms. Supervisory control and data acquisition is used to describe a system where both data acquisition and supervisory control are performed. Mobile Supervisory Control and Data Acquisition (referred to as Mobil SCADA) is the use of SCADA with the mobile phone network being used as the underlying communication medium. GSM is a wireless communication technology; most popular today for transmitting data anywhere in the world through SMS with the help of mobile phones. General Packet Radio Service (GPRS) is chosen as the specific mobile communication protocol to use as it provides an always online Inter connection without any time based charges. SMS is a globally accepted wireless service that enables the transmission of alphanumeric messages between mobile subscribers and external systems such as electronic mail, paging, and voice-mail systems. It is a store and forward way of transmitting messages to and from mobiles. SMS benefits includes the delivery of notifications and alerts, guaranteed message delivery, reliable and low cost communication mechanism for concise information, ability to screen messages and return calls in a selective way and increased subscriber productivity. 1.3 Basic Structure of PLC and SCADA 2. Methodology and Implementation 2.1. Block Diagram Explanation Fig. 2: Basic Structure of SCADA System Voltage from potential transformer and current from current transformer are given to the signal conditioning circuit where voltage and current signals are rectified and converted into required signal input for PLC Pressure and temperature signal from pressure sensor and temp sensor respectively are directly given to the PLC. The signals are compared in the PLC. & a connection from the PLC is given to the Relay which switches the circuit as per requirement.plc is interfaced with a computer where the real time and history data is observed and stored. 3.1. Circuit Diagram In the circuit diagram the two instrumentation transformer are used in which one is potential transformer (above) and another one is current transformer (below) on the left side of the programmable logic controller (PLC).which are used to step down voltage(230/9)v and current(3-4)a magnitude values of the single phase 50HZ alternating current supply. 196

Followed by the stepped down output of the instrumentation transformer are fed into the bridge rectifier, where an alternating voltage and current are converting into the pulsating unidirectional direct current. And then the pulsating D.C is filtered using capacitor (63V, 1000µF for voltage & 25V, 1000µF for current) filter which are connected across the bridge rectifier. Here the ripple of the pulsating D.C is 80-90% is removed. Followed by the potentiometer are connected across the filter which can be used to vary or adjust the filtered one quantity. And then the small value capacitors (104µF) are used across the potentiometer to get smooth and noise free output. And then a zener diode are connected in reverse biased mode across the PLC input terminal, which protect the signal conditioning circuit from the reverse current. One another rectifier and signal conditioning circuit is used with the same function and circuit element, as explained above, to provide the working or biasing voltage (power) to temperature sensor (LM35) & relay circuit. The 9V batteries are used to provide biasing voltage to the pressure sensor (MP3V5050). The all four inputs such as current, voltage, pressure and temperature are fed into the PLC, where PLC compares the real time data of all the inputs with the predefined values, which are set in the ladder diagram program. And depending upon the programmed conditions the PLC generates the control output which is fed into the relay and relay trips it s coil(either closing or opening it s contact) in order to protect the devices(load, appliances) etc. which has to protect. Fig.3: Block Diagram of Automation of the Sub-Station 197

K.P. Satheyamoorthy : Role of Controlling of Substation Using PLC And SCADA 3. Implementation 4. PLC HARDWARE Fig.4: Circuit diagram of Automation of the Sub-Station Fig.5: PLC Hardware Block Diagram 198

4.1. WORKING OF PLC: Bringing input signal status to the internal memory of CPU The field signals are connected to the I/P module. At the output of I/P module the field status converted into the voltage level required by the CPU is always available. At the beginning of each cycle the CPU brings in all the field I/P signals from I/P module & stores into its internal memory called as PII, meaning process image input. The programmable controller operates cyclically meaning when complete program has been scanned; it starts again at the beginning of the program. FIELD SIGNALS INPUT MODULE Fig.6: Working of PLC I/O BUS CPU : PII: PIQ : : : A PLC works by continually scanning a program. We can think of this scan cycle as consisting of 3 important steps. There are typically more than 3 but we can focus on the important parts and not worry about the others. Step 1-Check Input Status-First the PLC takes a look at each input to determine if it is on or off. In other words, is the sensor connected to the first input on? How about the second input? How about the third... It records this data into its memory to be used during the next step. Step 2-Execute Program- Next the PLC executes your program one instruction at a time. Maybe your program said that if the first input was on then it should turn on the first output. Since it already knows which inputs are on/off from the previous step it will be able to decide whether the first output should be turned on based on the state of the first input. It will store the execution results for use later during the next step. Step 3-Update Output Status-Finally the PLC updates the status of the outputs. It updates the outputs based on which inputs were on during the first step and the results of executing your program during the second step. 5. SUMMARY OF THE PAPER The following tables give summary of the paper as: Reliability, a large installed base, extensive support resources and low costs are some of the benefits of using PLCs as a basis for substation automation and SCADA systems. Therefore, controlling and monitoring of parameters like current, voltage, temperature, pressure etc could be done effectively. The process could be carried out with low voltage (upto 24v) with several system benefits, such as uninterrupted power supply, reduced man power, data storing & accuracy, and even more. Though the PLCs are developed to work out frequently in even harsh environments. They are designed to operate correctly over wide temperature ranges and in very high electromagnetic noise and high vibration condition. They can operate in dusty or humid environments as well. The number of PLCs which have been applied in various functional 199

K.P. Satheyamoorthy : Role of Controlling of Substation Using PLC And SCADA areas has allowed the designers of PLCs to create the resistance to the negative effects of harsh environments and workout it s function accurately. 5.1 By Placement and Coordination of FACTS controllers in multi-machine power systems Figure 1 By placement and coordination of FACTS controllers in multi-machine power systems 6. CONCLUSIONS The use of PLCs (Programmable Logic Controllers) in substation and distribution automation applications has grown in recent years. The economics of PLC based solutions mean that substation automation and SCADA solutions can be applied even more widely. This will help the utilities respond to the challenges presented by deregulation. As the use of PLCs in substations increases, the criteria for selection of control system integrators, engineering firms and consultants will become an extremely important factor in the success of PLC substation automation and SCADA projects. One of the most important criteria is that the control system integrator, the engineering firm or the consultant has sound business practices in place. They should also have a project management methodology in place to assure the success of these projects. REFERENCES [1] Musse Mohamud Ahmed, ECE, Kulliyyah of Engineering IIUM, Gombak, Kuala Lumpur, Malaysia, [2] M. M. Ahmed, W.L.Soo, Supervisory Control and Data Acquisition System (SCADA) Based Customized Remote Terminal Unit (RTU) for Distribution Automation System, 2nd IEEE International Conference on Power and Energy (PECon 08), December 1-3, 2008, Johor Baharu, Malaysia [3] Musse Mohamud Ahmed, New Supervisory Control and Data Acquisition (SCADA) Based Fault Isolation System for Low Voltage Distribution Systems, ECE, Kulliyyah of Engineering IIUM, Gombak, Kuala Lumpur, Malaysia. [4] J. G. GiIberl, PE G. R. Delhi, APPLICATION OF PROGRAMMABLE LOGIC CONTROLLERS TO SUBSTATION CONTROL AND PROTECTION, Pennsylvania Power & Light Company, Ahntown, PA 200

[5] M. Y. Cho, member IEEE, Development of Data Acquisition and Load Control System By Programmable Logic Controller for High Voltage Load consumer, Department of Electrical Engineering National Kaohsiung Institute of Technology Kaohsiung, Taiwan, China. [6] Jouni K. Pylvänäinent, Kirsi Nousiainen, Studies to Utilize Loading Guides and ANN for Oil- Immersed Distribution Transformer Condition Monitoring, IEEE Trans. Power Delivery, vol.22, no.1,jan 2007. [7] Leibfried, T, Online monitors keep transformers in service, Computer Applications in Power, IEEE, Volume: 11 Issue: 3, July 1998. [8] B.Berry, A Fast Introduction to SCADA Fundamentals and implementation, DSP Telecom, retrieved on July 28,2009,from http://www.dpstelecom.com/wp [9] Electricity Company of Ghana(ECG), Automation of ECG s Power Delivery Process (SCADA), retrieved on July 28,2009, http://www.ecgonline.info/projects/current Projects/Engineering/Projects/SCADA, 2008. [10] Lee, H.J. & Park, Y.M. (1996). A Restoration Aid Expert System for Distribution Substations; IEEE Transactions on Power Delivery, Vol. 11, pp.1765-1769 201