Redundancy unit CP-A RU Accessory for CP range power supplies

Similar documents
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Analog signal converters CC-E I/I Current / current isolators

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Redundancy Module QUINT-DIODE/40

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Thermistor motor protection

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Type: DILM32 10(24V50HZ) Article No.:

Power Supplies 3. SDN-P DIN Rail Series

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

PHOENIX CONTACT - 01/2007

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Type: DILM50(230V50HZ,240V60HZ) Article No.:

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

MCR1900 Media Converter 19-Slot Chassis

DLP-PU/E Instruction Manual

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Type: DILM9 10(24VDC) Article No.:

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Manual motor starter MS116

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Catalog. Modular DIN rail components Installation contactors

Safety technique. Emergency stop module BO 5988 safemaster

APD / Outputs 19" DC/DC Converter, 50 Watt

38 Series - Relay interface modules A

38 Series - Relay interface modules A

R.C.C.B. s two-pole LEXIC

Waveguide Access Point WGA631. Product Guide

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

RM4TG20 three-phase network control relay RM4-T - range V

STRATO LED Drivers 70W, Single output

49 Series - Relay interface modules A. Features

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Pluggable interface relays CR-P Pcb relays

Relés e Contatores de Estado Sólido SIRIUS

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

48 SERIES Relay interface modules 10 A

TEP 200WIR Series, Watt

Technicaldata General

PHOENIX CONTACT Features

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

TX OPEN RS232/485 module

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

80 Series - Modular timers 16 A. Features

MasterINTERFACE 39 Series - Relay interface modules

5SV Residual Current Protective Devices

MasterINTERFACE 39 Series - Relay interface modules

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

SHORT-FORM DATA MARKINGS. IECEx

Digital input modules

15 Series - Electronic step relay and dimmer. Features SERIE

PSR The compact range Description

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

7 - Phaseo power supplies and transformers

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

ST Series POWER SUPPLIES USER INSTRUCTIONS

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Product and functional description

System pro M compact Miniature Circuit Breaker S 200/S 200 M

ZS25 Screw Clamp Terminal Blocks Feed-through

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Manual Motor Starter MS 116 up to 16 A Technical Data

80 Series - Modular timers 16 A. Features

DC DC CONVERTER 1000W VDC Input / 12VDC Output

Three-phase monitoring relays Product group picture

EMR measuring and monitoring relays

Transcription:

Data sheet Redundancy unit Accessory for CP range power supplies ABB s redundancy units are used to establish true redundant redundancy which increases the availability of electrical systems significantly. 2CDC 271 010 F0006 Characteristics Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power supplies 2 integrated diodes for the decoupling of 2 switch mode power supplies up to 20 A Control module CP A CM (accessory) is used to monitor both inputs for undervoltage. One of two relay outputs de energizes when undervoltage is sensed at an input. The threshold value is adjustable from 14 to 28 V. The CP A CM plugs onto the front of the CP A RU unit. Approvals H UL 60950, CAN/CSA C22.2 No.60950 1) R EAC 1) 1) Approval refers to rated input voltage U in Order data Type Description Order code Redundancy unit: The CP A RU provides decoupling of two CP power supply units m 40 V and M 5 A. 1SVR427071R0000 Order data - Accessories Type Description Order code CP A CM Control module: The CP A CM provides monitoring of the input signals of the redundancy unit CP A RU. 1SVR427075R0000

Functions 1 1 INPUT L, N: Terminals input 2 Circuit diagram 2CDC 271 010 F0006 2 3 OUTPUT +/-, +/ : Terminals output 3 Application The redundancy unit CP A RU provides decoupling of two CP power supply units. It provides automatic redundant power supply operation for critical applications. It has 2 inputs, each up to 20 A, and 1 output up to 40 A. Operating mode Parallel operation, true redundancy with decoupling provided by the CP A RU Redundant circuits are used to increase the operational reliability and eliminate power supply outages. Events that can cause a power supply failure include: incorrect wiring, blown fuses, or failure of a single power supply. If a fault event occurs (called initial fault) in the first power supply circuit, power to all loads is then supplied by the second (redundant) power supply. For this reason, both power supplies must be sized to handle the total current requirement of all loads. The primary and the redundant power supplies are decoupled from one another by the CP A RU unit. It automatically switches from the primary to the redundant supply after a fault. It decouples the output of the failed power supply from the redundant supply preventing the initial fault from shorting or compromising the redundant supplies output. In this way, uninterrupted supply of power to all loads is guaranteed. When available, the two power supplies should be connected to different input voltage phases, to avoid loss of power caused by a blown fuse on the primary side of the power supplies. L1 L2 L3 N PE + - + - INPUT 1 INPUT 2 CP-... < 20 A L N PE OUTPUT Load CP-... < 20 A L N PE 2CDC 272 023 F0208 2CDC 272 023 F0208 Decoupling of power supply units with output currents > 20 A L+ L- + - + - INPUT 1 INPUT 2 + - + - INPUT 1 INPUT 2 L+ L- > 20 A > 20 A OUTPUT Load OUTPUT 2CDC 272 027 F0205 2CDC 272 027 F0205 2 - Redundancy unit Data sheet

Control of input voltages of CP A RU with CP A CM The control module CP A CM indicates the presence of both input voltages of the CP A RU via LEDs and energized output relays. The threshold values for the output relays are adjustable separately per channel from 14 to 28 V. If, by a fault (e.g. failure of a power supply, blown fuse), the voltage in a channel drops below the adjusted threshold value, the corresponding output relay de energizes. The green LEDs IN 1, IN 2 glow, if the corresponding voltage exceeds the adjusted threshold value. The green LED OUT glows, if the output voltage is higher than 3 V. Examples of application with accessories CP A RU with CP A CM for monitoring of two power supplies In case of fault: Fault signal If both relays are de energized, the voltages of both channels are below the adjusted threshold value (e.g. 20 V). This could mean, that both power supply units failed or are switched off, or that there is an overload on the secondary side. Momentary de energization of the relays may be caused by inrush current of a connected load, during starting. If one of the two relays de energizes, this can indicate that the primary power supply unit failed or is switched off, and the redundant power supply is now supplying power to the load. + - + - CP-S / CP-C Relay message channel 1 < 20 V CP-A CM Load Relay message channel 2 < 20 V CP-S / CP-C 2CDC 272 028 F0205 CP A RU with CP A CM for monitoring of one power supply In case of fault: Transfer to an alternative power supply The following example of application shows transferring to an alternative power supply (in this example a battery) after a failure in the primary power supply unit. + - + - CP-A CM CP-S / CP-C Battery L1 N PE L N PE Load 2CDC 272 029 F0205 2CDC 272 029 F0205 Data sheet Redundancy unit - 3

Installation Mounting The redundancy unit can be snapped on a DIN rail (TH 35-15 or TH 35-7.5 according to IEC/EN 60715) as shown in the accompanying picture. The device is set with its mounting rail slide on the upper edge of the mounting rail and locked by lifting it downwards. 2CDC 272 012 F0004 Demounting Remove the redundancy unit as shown in the accompanying picture. The latching lever is pulled downwards by means of the screwdriver. Then the device can be unhinged from the mounting rail edge and removed. 2CDC272013F0b04 Mounting position The devices have to be mounted horizontally with the input terminals on the top. In order to ensure a sufficient convection, the minimum distance to other modules must not be less than (A) 10 mm in horizontal direction and (B) 50 mm in vertical direction. 56,5 2.22 (B) (A) (A) 130 5.12 2CDC 272 013 F0009 (B) 135.5 5.35 2CDC 272 013 F0b09 4 - Redundancy unit Data sheet

Electrical connection Input side [INPUT 1 + / INPUT 2 + ] Connect the input terminals, stripping length of the cable see technical data. For channel 1 left hand input terminals +, for channel 2 right hand input terminals +. Electrical connection Output side [OUTPUT + + ] Rate the lines for the maximum output current or provide a separate fuse protection. We recommend to choose the cable cross section as large as possible in order to minimize voltage drops. Observe the polarity. Connection diagram INPUT 1 +, Connection of the output of power supply unit 1 2CDC 272 019 F0b05 2CDC 272 019 F005 INPUT 2 +, Connection of the output of power supply unit 2 OUTPUT ++, Output for load Data sheet Redundancy unit - 5

Safety instructions and warnings The device must be installed by qualified persons only and in accordance with the specific national regulations (e.g., VDE, etc.). These devices are maintenance-free chassis-mounted units. Disconnect system from supply network! Before any installation, maintenance or modification work: Disconnect the system from the supply network and protect against switching on. Before start of operation: Attention! Improper installation/operation may impair safety and cause operational difficulties or destruction of the unit. Before operation the following must be ensured: Connect to main according to the specific national regulations for class of protection I. Power supply cables and unit must be sufficiently fused and rated. Rate the output lines sufficiently for the output current and connect them with the correct polarity. In order to ensure sufficient air-cooling the distance to other devices has to be considered Screws at the enclosure are for internal grounding. Do not remove them! Do not connect cables! In operation: Do not modify the installation (primary and secondary side)! High current! Risk of electric arcs and electric shock (danger to life)! Risk of burns: Depending on the operation conditions the enclosure can become very hot If the internal fuse blows, most probably the device is defective. In this case, an examination of the switch mode power supply by the manufacturer is necessary. Attention! High voltage! Danger to life! The power supplies contain components with high stored energy and circuits with high voltage! Do not introduce any objects into the unit, and do not open the unit. With some units of this range the output is capable of providing hazardous energy. Ensure that the service personnel is protected against inadvertent contact with parts carrying energy. 6 - Redundancy unit Data sheet

Technical data Data at T a = 25 C, U in = 230 V AC and rated values, unless otherwise indicated Input circuits Supply circuits (+/ -, +/ -) in combination with CP-A CM Rated input voltage U in 24 V DC Input voltage range per channel 10-28 V DC 13-28 V DC Rated input current I in per channel Maximum input current per channel Transient overvoltage protection Output circuit Rated output voltage Uout Voltage drop Rated output current Iout 1-20 A 30 A for 300 s yes 24 V DC typ. 0.6 V, max. 0.9 V Output ratings per channel T a = 60 C 10-28 V DC / 40 A 13-28 V DC / 40 A 1-40 A (++/--) T a = 70 C 10-28 V DC / 30 A 13-28 V DC / 30 A Derating 60 C < T a m 70 C 2.5 % per Kelvin temperature increase Peak output current Resistance to reverse feed 60 A for 300 s < 40 V General data Dimensions (W x H x D) 56.5 (60 1) ) x 130 x 137 mm (2.22 (2.36 1) ) x 5.12 x 5.39 in) Weight 0.89 kg (1.96 lb) Minimum distance to other units horizontal / vertical 10 mm / 50 mm (0.39 in / 1.97 in) Degree of protection housing / terminals IP20 / IP20 Material of housing housing shell / cover aluminium / zinc-coated sheet steel Protection class III 2) Mounting DIN rail (IEC/EN 60715) Mounting position horizontal 1) incl. lateral screw 2) This device is designed for connection to a safety extra-low voltage source. If no safety extra-low voltage is used at the input side, the lateral screw can be used for grounding of the housing (protection class I). Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule 2.5-10 mm 2 (14-8 AWG) Stripping length Tightening torque fine-strand without wire end ferrule rigid 0.5-10 mm 2 (20-8 AWG) 0.5-16 mm 2 (20-6 AWG) 12 mm (0.47 in) 1.2-1.5 Nm Environmental data Ambient temperature range operation -25...+70 C full load -25...+60 C (without derating) storage -40...+85 C Damp heat (IEC/EN 60068-2-3) 93 % at 40 C, no condensation Climatic class (IEC/EN 60721) 3K3 Isolation data Insulation voltage between input / output / housing 500 V AC (routine test) Pollution degree (EN 50178) 2 Standards / Directives Standards IEC/EN 60950-1, IEC/EN 61204 EMV Directive 2014/30/EU RoHS Directive 2011/65/EU Data sheet Redundancy unit - 7

Electromagnetic compatibility Interference immunity to IEC/EN 61000 6 2 electrostatic discharge IEC/EN 61000 4 2 Level 3 (air discharge w8 kv, contact discharge w6 kv) radiated, radio-frequency, IEC/EN 61000 4 3 Level 3 (10 V/m) electromagnetic field electrical fast transient / burst IEC/EN 61000 4 4 Level 3 (w2 kv) surge IEC/EN 61000 4 5 Level 1 (w0.5 kv) conducted disturbances, induced by IEC/EN 61000 4 6 Level 3 (10 V) radio-frequency fields Interference emission IEC/EN 61000 6 3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B Dimensions in mm [inches] 2CDC 272 001 F0007 54 [2.13 ] 56,5 [2.22 ] 24 [0.94 ] 2CDC 272 016 F0007 CP-A CM Further Documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C02xx Power Supply Units Application manual 2CDC 114 048 M020x You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, control and protection -> Power supplies. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> Low Voltage Products & Systems -> Control Products -> Power Supplies. 8 - Redundancy unit Data sheet

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 114 036 D0202 (09/2016) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2016 ABB All rights reserved