Technical documentation. Conventional gas fired boilers open vented / sealed unvented CGU-2 / CGU-2K CGG-2 / CGG-2K

Similar documents
NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

Operating instructions

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

ELECTRIC CENTRAL HEATING FLOW BOILER

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

High Efficiency Boiler Range Technical Guide

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

For installation guide see reverse of book

Operating instructions

User's Instructions. Alpha HE CB25/33 and HE SY25

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Baxi Combi 80e & 105e

HEAVY DUTY STORAGE GAS

UDSA - UDSBD unit heater

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

High-efficient gas boiler CompactGas

Aludesign K A T A L O G

ECOplus Solar Cylinder

Electric Flow Boiler

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Vitocaldens 222-F Compact Gas-Hybrid appliance

ECOCIAT. Domestic hot water heat recovery unit

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Smile. The All-In-One Heating Controller

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

A BIG STEP IN REDUCING YOUR CARBON FOOTPRINT.

Gas Instantaneous Water Heater

INSTANTANEOUS GAS FIRED

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

Vacuum drying oven for non-flammable solvents

Operating instructions

Installation and Servicing Instructions

Description of functions

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

HERZ-Thermal Actuators

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Drayton Digistat +2RF/+3RF

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Laddomat Charging unit

Installation and maintenance instructions. Danfoss Vent


Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Gas water heaters. Why Vaillant? Because warm water is our business for more than 135 years.

Worcester GB162 wall mounted gas-fired condensing boiler series

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Zenith Solar thermal 4.5m pump station Installation manual

Daikin Altherma Hybrid Heat Pump

1 DESCRIPTION OF THE APPLIANCE

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Daikin Altherma Hybrid Heat Pump

Commercial Gas Furnace Upflow

Response: The combi boiler. Response: The fit anywhere combi

VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy

Stove-boiler for solid fuels KW Directions for use and assembling

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Apartment and Communal Heating Solutions

VIESMANN. VITODENS Gas condensing boiler 3.8 to 35.0 kw. Technical guide. VITODENS 200-W Type WB2C. VITODENS 222-W Type WS2B. VITODENS 300-W Type WB3D

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

User manual and Installation instructions

Spare Parts List M96A.24SM/B M96A.28SM/B

The Concept of Condensing Boilers

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

NAVIEN AMERICA INC FITCH AVENUE

maximise the sun s energy with warmflow solar Warmflow Solar

ROTEX gas hybrid heat pump. A strong team.

Transformer oil cooler ALFA A02

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Ecoskid. Working towards a cleaner future. Prefabricated Heating System 56kW 230kW. heating specialists

Commercial Gas Water Heater

RPV - RP - RA air handling units

Technical Data Manual Model Nos. and pricing: see Price List

VIESMANN. Installation and service instructions VITOPEND 100-W. for contractors

Oil - kerosene burners

Luna 3 Comfort Troubleshooting Guide June 2008

Installation & User Instructions

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Combi switchbox with integrated 3/2 way pilot valve

VIESMANN. VITODENS Gas condensing boiler 1.9 to 35.0 kw. Technical guide. VITODENS 200-W Type B2HA, B2KA. VITODENS 222-W Type B2LA

WHOLESALE DIRECT INC WEST 65TH STREET

ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating!

Refrigeration Compressed Air Dryer Buran Ultrapulse

INSTALLATION & TECHNICAL MANUAL


Alpha CD13R,18R and 24R

Transcription:

Technical documentation Conventional gas fired boilers open vented / sealed unvented CGU-2 / CGU-2K CGG-2 / CGG-2K

Conventional gas fired boilers - open vented and sealed unvented The advantages of the WOLF conventional gas fired boilers * BM as accessory Tested according to the applicable EC directives Electronic ignition and monitoring Water-cooled, atmospheric premix burner for natural gas E, LL and LPG Energy efficiency in accordance with Efficiency Directive (3 stars according to 92/42/EEC for CGG-2(K)) Wolf low NOx unit with Hydro Tec System designed for lowest emissions Control unit with ebus capability for connection to Wolf digital control accessories Modulating controlled output in heating and DHW mode Equipped as standard with three-stage heating circuit pump, three-way diverter valve and 10 l expansion vessel. Easy installation and operation Electronic output matching; no adjustment necessary at the gas combination valve High standard utilisation rate up to >94% (Hi) / 85% (Hs) for the best possible energy utilisation Emissions according to NOx class 5 Powder-coated white RAL 9016 casing High energy efficiency and compact design Two-year warranty CGU-2-18, -24 conventional gas fired boiler for central heating Conventional, open flue gas fired boiler for low temperature heating with DHW cylinder connection facility, e.g. CSW-120; electronic flue gas monitoring; tested in accordance with EC directives for connection to a chimney CSW-120 2

Conventional gas fired boilers - open vented and sealed unvented CGU-2K-18, -24 conventional gas fired combi boiler for central heating and DHW Conventional, open flue, gas fired combi boiler for low temperature heating and DHW preparation with integral DHW heat exchanger and electronic flue gas monitoring; tested in accordance with EC directives for connection to a chimney. CGG-2-18, -24 conventional gas fired boiler for central heating Conventional, balanced flue, gas fired boiler for low temperature heating with option to connect a DHW cylinder, e.g. CSW-120; "ERA" electronic pipe length adjustment; variable fan speed; tested in accordance with EC directives for connection to a balanced flue chimney or balanced flue routing to the outside. CSW-120 CGG-2K-18, -24 conventional gas fired combi boiler for central heating and DHW Conventional, balanced flue, gas fired combi boiler for low temperature heating and DHW preparation with integral DHW heat exchanger; "ERA" electronic pipe length adjustment; fan with variable speed control; tested in accordance with EC directives for connection to a balanced flue chimney or balanced flue routing to the outside. 3

Dimensions 258 CGG-2(K) 18/24 366 CGU-2(K) 18 366 CGU-2(K) 24 344 (CGG-2) (CGU-2) 190 226 393 58 636 14 1 2 5 3 70 120 200 440 4 30 70 855 1 2 4 3 5 50 73 180 Conventional gas fired combi boiler Conventional gas fired combi boiler for central heating 1 Heating flow Heating flow 2 DHW Cylinder flow 3 Cold water Cylinder return 4 Heating return Heating return 5 Gas connection Gas connection With the new accessories acc. to the price list for installation on finished and unfinished walls, you are equally well equipped for new build or renovation. DHW cylinder CSW-120 made from steel with enamel coating Connections R ¾" for flow, return, cold water, hot water and DHW circulation above the cylinder as well as the cleaning aperture at the top of the cylinder for easy connection and cleaning Powder-coated white RAL 9016 casing Thermal insulation, all around the cylinder, applied directly to the cylinder surface, highly effective and low heat losses 810 Corrosion protection through enamelled cylinder interior and indirect internal coil to DIN 4753 part 3. Additional corrosion protection through protective magnesium anode integrated into the inspection and cleaning aperture 542 Indirect internal coil with large heat exchanger surface area for short heat-up times 542 High constant DHW output Drain R ½" at the front, incl. drain valve and hose connection Adjustable feet Five-year warranty 4 DHW cylinder Type CSW-120 Cylinder capacity l 115 Constant cylinder output (80/60-10/45 C) kw - l/h 29-710 Standby heat loss kwh/24 h 1.5 Output factor N L 1.0 Max. operating pressure DHW bar 10 Max. operating pressure heating water bar 12 Max. permissible DHW cylinder temperature C 95 Max. permissible heating water temperature C 110 Weight (dry) kg 65

Specification Type CGU-2-18 CGU-2-24 CGU-2 K-18 CGU-2K-24 CGG-2-18 CGG-2-24 CGG-2 K-18 CGG-2K-24 Output range kw 8-18 10.9-24 8-18 10.9-24 8-18 10.9-24 8-18 10.9-24 Load range kw 8.8-20.2 12.0-26.5 8.8-20.2 12.0-26.5 8.5-19.7 11.7-26.5 8.5-19.7 11.7-26.5 Standard utilisation rate at 75/60 C (Hi/Hs) % 94/85 92/83 94/85 92/83 94/85 92/83 94/85 92/83 Width mm 440 440 Height mm 855 855 Depth mm 393 393 Flue/wall clearance mm 226 190 Flue connection Ø mm 110 130 110 130 - - - - Balanced flue connection Ø mm - - - - 60/100 60/100 60/100 60/100 Type of connection for balanced flue type B 11BS B32, C12x, C32x, C42x, C52, C82 Gas category II 2ELL3P (Germany) / II 2H3P (Austria) II 2ELL3P bzw. II 2ELL3B/P (DE) / II 2H3P bzw. II 2H3B/P (AT) Gas connection, outside Ø G ¾ ¾ Heating flow, outside Ø G ¾ ¾ Heating return, outside Ø G ¾ ¾ Cold water connection G - - ¾ ¾ - - ¾ ¾ DHW connection G - - ¾ ¾ - - ¾ ¾ Cylinder flow G ¾ ¾ - - ¾ ¾ - - Cylinder return G ¾ ¾ - - ¾ ¾ - - Residual pump head: Stage 1/2/3 430 l/h pump rate (10kW at t = 20K) mbar 250/250/250 250/250/250 250/250/250 250/250/250 250/250/250 250/250/250 250/250/250 250/250/250 770 l/h pump rate (18kW at t = 20K) mbar 180/250/250 160/250/250 180/250/250 160/250/250 180/250/250 160/250/250 180/250/250 160/250/250 1030 l/h pump rate (24kW at t = 20K) mbar -/-/- - / 210/250 -/-/- - / 210/250 -/-/- - / 210/250 -/-/- - / 210/250 Expansion vessel nominal capacity l 10 10 Expansion vessel inlet pressure bar 0.75 0.75 Maximum draw-off temperature 2) C - - 55 55 - - 55 55 At a drawing rate of l/min - - 2.7-5.8 2.7-7.7 - - 2.7-5.8 2.7-7.7 Gas supply details: Natural gas E/H (H i = 9.5 kwh/m 3 = 34.0 MJ/ m 3 ) m 3 /h 2.1 2.8 2.1 2.8 2.1 2.8 2.1 2.8 Natural gas LL (H i = 8.1 kwh/m 3 = 29.2 MJ/ m 3 ) m 3 /h 2.3 3.1 2.3 3.1 2.3 3.1 2.3 3.1 LPG P (H i = 12.9 kwh/kg = 46.3 MJ/kg) kg/h 1.5 2.1 1.5 2.1 1.5 2.1 1.5 2.1 Gas supply pressure: Natural gas mbar 20 20 LPG P mbar 50 50 Max. overall pressure, heating bar 3 3 Required draught for the heat source Pa 1.5 - Flue gas temperature 1) C 80/123 80/125 80/123 80/125 100/160 100/165 100/160 100/165 Flue gas flow rate g/s 12.8/13.9 15.0/19.0 12.8/13.9 15.0/19.0 6.8/8.5 10.0/13.2 6.8/8.5 10.0/13.2 Flue gas category g/s - - - - G01 (previously II 1 ) Total weight kg 39 41 39 41 42 43.5 42 43.5 Fitted fuse (medium slow) A 3.15 3.15 Protection IPX4D Power supply 230V/50 Hz Power consumption / standby W 83/6 120/6 CE ID CE-0085BS0516 CE-0085BT0420 1) Observe when connecting to a balanced flue chimney. 2) Relative to a cold water temperature of 10 C. 5

Standard control unit ON/OFF Reset button Heating water temperature selector Thermometer Illuminated signal ring as status display Illuminated signal ring Display Flashing green Constant green light Flashing yellow Constant yellow light Flashing red Explanation DHW temperature selector Pressure gauge Standby (power supply ON; no heat demand) Heat demand: Pump running; burner OFF Emissions test mode Burner ON; flame steady Fault 3 7 2 8 1 4 5 6 DHW temperature selector Settings 1-9 correspond to a DHW temperature of 40-65 C for gas combi boilers, or 15-65 C for gas boilers with a cylinder. Combined with a temperature controller for wall mounted gas fired boilers, the adjustment at the DHW 9 temperature selector is disabled; instead the temperature is selected at the boiler temperature controller. 4 5 6 Heating water temperature selector Settings 2-8 correspond to a heating water temperature of 20-75 C. Combined with a temperature controller for wall mounted gas fired boilers, the adjustment at the heating water thermostat is disabled; instead the temperature is selected at the boiler temperature controller. 3 7 2 8 Setting Winter mode (settings 2 to 8) The circulation pump operates in heating mode. Summer mode Switch set to circulation pump OFF (heating OFF); only DHW heating, frost protection, pump anti-seizing protection enabled, i.e. the circulation pump runs for approx. 30 s every 24 hours. Emissions test mode Turning the switch to position lets the boiler operate at maximum output. The illuminated signal ring flashes yellow for 15 minutes or until the maximum flow temperature has been exceeded. C 0 120 4 0 Thermometer/pressure gauge The heating water temperature and the system water pressure are displayed. 3 bar 2 1 6

Control accessories Standard control unit part of the standard delivery of the conventional gas fired boiler BM programming module (incl. outside temperature sensor) as weather-compensated temperature controller BM programming module with wall mounting base (accessory) as remote control Two-wire ebus connection Room temperature-dependent/weather-compensated temperature control Time programs for central and DHW heating LCD with background illumination Easy plain text guide through the menus Control by rotary selector with key function Four function keys for frequently used functions (heating, DHW, setback, help) Installation either inside the boiler control unit, or as a remote control in a wall mounting base Option for MM mixer module Only one programming unit required for multi-boiler systems Can be extended with MM mixer module (up to 7 mixer circuits) Fault diagnosis MM mixer module Extension module for regulating one mixer circuit Weather-compensated flow temperature control Easy controller configuration by selecting one of the preset system versions 1... 7 BM programming module can be clipped into the boiler or extended as a remote control with wall mounting base Rast-5 connection technology Incl. flow temperature sensor SM1 solar module Extension module for regulating one solar circuit In conjunction with Wolf boilers, greater energy savings through intelligent cylinder reheating, i.e. blocking cylinder reheating when there is sufficient solar yield Temperature differential control for one heat consumer Maximum cylinder temperature limit Display of the set and actual values on the BM programming module Integral hours run meter Optional connection of heat meters Rast-5 connection technology Incl. collector sensor and cylinder sensor, each with sensor well 7

Control accessories SM2 solar module Extension module to control a solar thermal system with up to 2 cylinders and 2 collector arrays, incl. 1 collector sensor and 1 cylinder sensor, each with sensor well Easy controller configuration by selecting one of the preset system versions In conjunction with Wolf boilers, greater energy savings through intelligent cylinder reheating, i.e. blocking cylinder reheating when there is sufficient solar yield Capturing the heat volume Display of the set and actual values on the BM programming module ebus interface with automatic energy management Rast-5 connection technology Two-wire ebus connection KM cascade module Extension module for regulating systems with a low loss header or cascade control Can be used for conventional gas fired boiler control units (4 appliances) Easy controller configuration by selecting one of the preset system versions Control of one mixer circuit BM programming module can be clipped into the boiler or extended as a remote control with wall mounting base 0-10 V input for GLT systems; fault message output 230 V ebus interface with automatic energy management Rast-5 connection technology ART Analogue room temperature controller with day program for central and DHW heating Room temperature-dependent flow temperature Display for showing the room temperature, time and fault messages Room temperature-dependent frost protection AWT Analogue weather-compensated temperature controller with day program for central and DHW heating Weather-compensated flow temperature Display for showing the room temperature, outside temperature, time and fault messages Room temperature hook-up Frost protection Automatic energy-saving appliance 8

Control accessories Radio clock (DCF77 signal) with outside temperature sensor for automatic time adjustment. Radio clock (DCF77 signal) for automatic time adjustment. Two-wire ebus connection Wireless outside temperature sensor (only in conjunction with a receiver for wireless outside temperature sensor and remote control, part no. 27 44 209) Wireless receiver for wireless outside temperature sensor and wireless remote control incl. radio clock (DCF77 signal) Wireless remote control (only in conjunction with a receiver for wireless outside temperature sensor and remote control) Max. one wireless remote control per mixer circuit. ISM1 - RS232 interface module (Remote service system) for direct or remote access to the control system via PC and for transferring fault text messages, consisting of: Interface module ISM1 and software WRS-Soft. ISM2 - USB/eBUS interface module for direct access via PC to the control unit and for transferring fault messages as SMS, comprising: Interface module ISM2 and software WRS-Soft. 9

Balanced flue routing Versions CGG-2/CGG-2 K Versions B32 Connection to a moisture-resistant balanced flue chimney, maximum pipe length from centre of boiler bend to connection 2 m (open flue) Maximum length 1) [m] System Ø 60/100 Calculation according to EN 13384 (duct manufacturer) C12x Outside wall connection (balanced flue) 4 C32x Vertical roof outlet through a pitched or flat roof, and 4 horizontal roof outlet through a pitched roof (balanced flue) C42x Connection to a balanced flue chimney (LAS), maximum pipe length from centre of boiler bend to connection 2 m (balanced flue) Calculation according to EN 13384 (balanced flue manufacturer) C52 Connection to a flue pipe and supply air from external wall or roof ( balanced flue) 25 C82 Connection to a flue pipe in aduct and supply air from an external wall ( balanced 25 flue) system Note: Systems C12x, C32x and C42x are also suitable for installation in garages. 1) If necessary, adapt the installation examples to the building regulations and requirements of your country/region. Discuss any questions relating to installation, particularly as regards fitting inspection covers and ventilation apertures, with your local heating engineer/flue gas inspector. Balanced flue routing The calculated length of the balanced flue must not exceed 4 m when installing the boiler on an external wall or when the balanced flue is routed through the roof. The calculated length of the balanced flue routing comprises the straight pipe length and the length of the pipe bends. In this calculation, a 90 bend is calculated as being 1 m and a 45 bend as being 0.5 m. Example: ^ length of straight ^ balanced flue 1.5 m 1 x 90 bend = 1 m 2 x 45 bends = 2 x 0.5 m L = straight length + bend length L = 1.5 m + 1 x 1 m + 2 x 0.5 m L = 3.5 m Connection to a balanced flue chimney or flue gas chimney The straight balanced flue routing must not be more than 2 m long when installing in a balanced flue chimney (LAS) or a flue chimney. In addition to the boiler connection bend, a maximum of two 90 diverters may be installed. 10

Conventional gas fired boilers CGU-2 Conventional gas fired boiler for central heating with option to connect a DHW cylinder. CGU-2K Conventional gas fired boiler for central and DHW heating. CGG-2 Conventional gas fired boiler for central heating with option to connect a DHW cylinder. CGG-2K Conventional gas fired boiler for central and DHW heating. Tested in accordance with EC directives and DIN EN 297, 483 and 625, and for heating systems according to DIN EN 1282 with flow temperatures up to 95 C and 3 bar permissible operating pressure. Suitable for modulating operation down to room temperature; modulating output control; automatic matching of the air factor to the balanced flue system with CGG-2. Flue gas monitoring with CGU-2. Premix burner equipped and adjusted at the factory for natural gas E and LL. When ordering for LPG a conversion set is enclosed loose. CGU-2... for chimney connection, CGG-2... with closed combustion chamber for open flue and balanced flue operation. Control with gas burner control unit, electronic ignition and ionisation flame monitor; variable speed fan. Powder-coated white RAL 9016 casing. Control accessories CGU-2 CGU-2K CGG-2 CGG-2K BM programming module Wall mounting base MM mixer module SM1 solar module SM2 solar module KM cascade module Analogue room temperature-dependent controller with day program ART Analogue weather-compensated controller AWT Radio clock with outside temperature sensor Radio clock for automatic time adjustment Wireless receiver - required for wireless outside temperature sensor and wireless remote control WRS - remote service system Hydraulic accessories and gas supply accessories Gas ball valve (angle or straight-through version), chrome plated, with or without thermally activated shut-off valve Safety valve Rp ½" up to 3 bar, chrome plated Drain set, safety valve with hose, hose retainer, siphon and rosette, transparent plastic Plug set for DHW and cold water connection Accessories for installation on unfinished walls Panel for installation on unfinished walls Connection set for installation on unfinished walls Angle maintenance valve G ¾", chrome plated Angle maintenance valve G ¾" with connection R ½" for safety valve, chrome plated DHW connector G ½", chrome plated Cold water connector G ½", chrome plated Accessories for installation on finished walls Connection set for installation on finished walls Straight-through maintenance valve Rp ¾", chrome plated Straight-through maintenance valve Rp ¾" with connection R ½" for safety valve, chrome plated DHW connector R ½", chrome plated Cold water connector R ½" with shut-off valve, chrome plated Connection panel for installation on finished walls DHW cylinder CSW-120 Connection set CSW for installation on unfinished walls Connection set CSW for installation on finished walls Connection set for third party installation Balanced flue accessories Concentric balanced flue routing Ø 60/100 mm Aluminium balanced flue gas pipe Ø 110 mm Aluminium balanced flue gas pipe Ø 130 mm Adaptor Ø 60/100 mm to Ø 63/96 mm 11

The comprehensive equipment range from system supplier Wolf offers the ideal solution for commercial and industrial buildings, for new build and for modernisation projects alike. The range of Wolf control units fulfils every need where heating convenience is concerned. The products are easy to operate, energy-efficient and reliable. Photovoltaic and solar heating systems can be quickly integrated into existing systems. All Wolf products can be easily and rapidly commissioned and maintained. Wolf GmbH, PO Box 1380, D-84048 Mainburg, Tel.: +49 87 51 / 74-0, Fax: +49 87 51 / 74-1600, Internet: www.wolf-heiztechnik.de 12 Part no. 4800589 The competent brand for energy saving systems 2014/02 GB Subject to technical modifications