Installation- and maintenance instruction CTC 950

Similar documents
Electric Flow Boiler

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Overheating limit control

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

ELECTRIC CENTRAL HEATING FLOW BOILER

Laddomat Charging unit

Description of functions

1 DESCRIPTION OF THE APPLIANCE

ECOCIAT. Domestic hot water heat recovery unit

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

AMBASSADOR (KITCHEN), COUNTRYMAN (OUTDOOR) & CONSUL (BOILERHOUSE) CONSENSING BOILERS SENATOR (KITCHEN) & COUNTRYMAN (OUTDOOR) COMBI CONSENSING BOILERS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

LK Electric Boiler - 4,5

Installation and maintenance instructions. Danfoss Vent

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED)

ELECTRIC INSTANTANEOUS WATER HEATER

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Operators manual Basic water heater

Operating instructions

Mikrofill Ethos Condensing combination boiler

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

HEAVY DUTY STORAGE GAS

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

Response: The combi boiler. Response: The fit anywhere combi

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

Operating instructions

Baxi Combi 80e & 105e

SOLAR HEATING SYSTEMS.

Condensing Boiler Efficiency

For installation guide see reverse of book

High Efficiency Boiler Range Technical Guide

LG Electronics AE Company, Commercial Air Conditioning

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

SF15K SF05KSS, SF10KSS

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

HEAT INTERFACE UNITS (Modular)

Technical data. Danfoss DHP-A

OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS.

Laddomat 21 Charging Unit

Spare Parts List M96A.24SM/B M96A.28SM/B

Luna 3 Comfort Troubleshooting Guide June 2008

Oil - kerosene burners

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Power consumption (kw)

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

After Sales Service Guide

TMS TANK MANAGEMENT SYSTEM

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

CALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Zenith Solar thermal 4.5m pump station Installation manual


FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES


TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

Operating instructions

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Commercial Semi-Instantaneous Water Heaters

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

stainless steel pre-assembled manifolds

Daikin Altherma hybrid heat pump. The natural combination

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Air Source Heat Pump Installation and Maintenance Manual

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

2.0 Technical Details 2.1 Combi Sequence of Operation Flow Chart Dimensions Flue Options & Dimensions Technical Data...

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

INSTALLATION & TECHNICAL MANUAL

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Stove-boiler for solid fuels KW Directions for use and assembling

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

BoilerMate SP. benchmark. user instructions A - C L A S S

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

HALSTEAD. Best db 30/40/50/60 HALSTEAD INSTALLATION & SERVICING INSTRUCTIONS FOR THE

VIBIEMME DOMOBAR JUNIOR 2B SPLIT-VIEW DIAGRAM AND SPARE-PARTS LIST

User's Instructions. Alpha HE CB25/33 and HE SY25

Oil and Coolant Circulating Heating System. Model - OCSM

ECOplus Solar Cylinder

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

GRANT. Vortex Condensing Oil Boilers. USER, INSTALLATION and SERVICING INSTRUCTIONS

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Transcription:

161 505 10-1 Art.no 580090002/3 Eng. Feb -03 Providing sustainable energy solutions worldwide Installation- and maintenance instruction CTC 950 Wall mounted oil-/gas-fired unit

Art.no 580090002/3 Eng. Feb -03 Installation and maintenance CTC 950 Wall mounted oil-/gas-fired unit 161 105 07 05-10/From Serialno:7115-0202-41 1

161 505 10 03-01

TABLE OF CONTENTS 01. Technical data 1.1 General description... 4 1.2 Technical data...4 1.3 Construction...5 02. Installation CTC 950 2.1 With one heating circuit without hot water...6,7 2.2 With hot water tank and one heating circuit...8,9 2.3 With hot water tank and two heating circuits...10,11 2.4 With heat exchanger...12,13 03. Electrical installation 3.1 General information...14 3.2 Electrical diagram D-580070...15 3.3 Electrical diagram D-580097...16 3.4 Electrical diagram D-580098...17 04. Operation 4.1 Control panel...18 4.2 Start-up... 19 05. Assembly instruction boiler...20,21 06. Assembly instruction pipe kit 6.1 Pipe kit (579990301)... 22 6.2 Pipe kit (580035301)...23 07. Assembly instruction heat exchanger (579970301)...24,25 08. Assembly instruction hot water priority relay (580166402)...26 09. Service oil burner... 27 10. Service boiler... 28 11. Service check and electrical installation... 29 12. Chimney solutions 12.1 Balanced flue system 80/125...30 12.2 Separate flue outlet (80 mm) and air inlet (80 mm)... 31 3 161 115 06 02-01

01. TECHNICAL DATA 1.1 General description The CTC 950 is a wall mounted oil fired unit. CTC 950 is delivered with expansion vessel, circulation pump, oil burner, instrument panel and safety valve. CTC 950 combines small dimensions, easy maintenance, extremely low noise level and high efficiency. CTC Quality : Made in Sweden:The main task of the CTC engineers has always been and will be to combine Swedish steel quality and innovative techniques of thermic exchange in order to ensure highest efficiency and long life and at the same time respecting nature and environment Modern design: The new compact design of the oil wall-mounted unit - CTC 950 -is a new innovative development which satisfies the needs of present and future markets in every aspect. The simple and attractive casing conceals a complete central heating system. Compact air/flue-gas system : The new CTC 950 wall-mounted boiler unit can be used as preferred for operation that is dependent on or independent of the room air. The CTC LAS system is made of high-grade INOX stainless steel and can be used with advantage for the concentric connection of the air supply and flue gas duct in houses without a conventional chimney. The supply air connection can also be made using a separate connecting piece. If the house already has a chimney, this can continue to be used with the CTC LAS system. The CTC 950 wall-mounted boiler unit is available in several models. It can be equipped at the factory with the preferred burners. 1.2 Technical data CTC 950 Output kw 23,3 Input kw 25,5 Weight kg 112 Boiler efficiency % 91,5 Water content l 23 Flue gas outlet ø 82 mm int. Air inlet ø 80 mm Heating flow G 3/4 Heating return G 3/4 Expansion vessel l 10 Max working pressure bar 3 Test pressure (in production) bar 4,3 Safety valve bar 2,5 Boiler water resistance T 20 20 mbar < Option: Heat exchanger Hot water capacity 10-45 C l/min 9,3 Option: Hot water tank Hot water capacity 10-45 C l/h 620 l /10 min 250 4 1(10) 161 145 07 02-01

01. TECHNICAL DATA 1.3 Construction Air inlet Flue outlet with sealing Automatic air bleeder Manometer Safety valve 2,5 bar Insulation Expension vessel Cleaning door Baffle plate 4 pcs Burner Baffle plate stainless steel1 pcs Filling valve only when at exchanger version Combustion chamber Pump Heat exchanger complete for domestic hot water (option) Filling / draining valve 5 2(10) 161 145 07 02-01

02. INSTALLATION 2.1. CTC 950 with one heating circuit without hot water. Electrical diagram D-580070 Dimensions 1. Flue outlet diam 82 mm internal with high temp sealing diam 80 mm 2. Air inlet hose diam 80 mm internal 3. Flow G 3/4 internal/external 4. Return G 3/4 external 6 3(10) 161 145 07 02-01

02. INSTALLATION 2.1. CTC 950 with one heating circuit without hot water 7 4(10) 161 145 07 02-01

02. INSTALLATION 2.2 CTC 950 with hot water tank and one heating circuit Pipe kit (P/N 579990301) 1-circuit, assembly instr. see chapter 06. Mixing valve (P/N 912912401) Electrical diagram D-580097. Dimensions 1. Flue outlet diam 82 mm internal with high temp sealing diam 80 mm 2. Air inlet hose diam 80 mm internal 3. Flow G 1 ½ (nut), alt G 1 internal 4. Return G 1 ½ (nut), alt G 1 internal 5. Flow to hot water tank G 3/4 internal 6. Return from hot water tank G 3/4 external 7. Mixing valve 8 5(10) 161 145 07 02-01

02. INSTALLATION Examples CTC 950 with hot water tank and one heating circuit 9 6(10) 161 145 07 02-01

02. INSTALLATION 2.3 CTC 950 with hot water tank and two heating circuits 2-circuit pipe kit (P/N 580035301), assembly instr. see chapter 06 Mixing valve (P/N 912912401) Electrical diagram D-580097 Dimensions 1. Flue outlet diam 82 mm internal with high temp sealing diam 80 mm 2. Air inlet hose diam 80 mm internal 3. Flow G 1 ½ (nut), alt G 1 internal 4. Return G 1 ½ (nut), alt G 1 internal 5. Flow to hot water tank G 3/4 internal 6. Return from hot water tank G 3/4 external 7. Mixing valve 10 7(10) 161 145 07 02-01

02. INSTALLATION Examples CTC 950 with hot water tank and two heating circuits 11 8(10) 161 145 07 02-01

02. INSTALLATION 2.4 CTC 950 with heat exhanger and one heating circuit Heat exhanger cpl (579970301) Mixing valve (912912401) Hot water priority relay (580166402) Electrical connection acc. to: - with mixing valve and DHW priority relay: electrical diagram (D-580098) - without mixing valve and DHW priority relay: electrical diagram (D- 580070) Assembly instruction heat exchanger cpl, see chapter 07. Dimensions 1. Flue outlet diam 82 mm internal with high temp sealing diam 80 mm 2. Air inlet hose diam 80 mm internal 3. Flow G 1 ½ (nut), alt G 1 internal 4. Return G 1 ½ (nut), alt G 1 internal 5. Hot water G 1/2 internal 6. Cold water G 1/2 internal 7. Mixing valve 12 9(10) 161 145 07 02-01

02. INSTALLATION 2.4 Examples CTC 950 with heat exhanger and one heating circuit With mixing valve. Note: DHW priority relay (580166402) must be installed Without mixing valve. 13 10(10) 161 145 07 02-01

03. ELECTRICAL INSTALLATION 3.1 General information The electrical installation must be made according to current regulations. In particular, there must be a proper connection to an efficient ground system Check Two pole switch Power supply cable Fuse Circulation pump Burner Have the electrical installation and system checked by professionnally qualified electricians, who certify that the electrical installations correspond to current regulations. A two-pole switch with a gap between contacts of at leat 3mm must be installed upstream from the boiler. When connecting the power supply cable to the connection terminal board, make sure that the ground cable is longer than the line and the neutral cable, so that if the cable is jerked off, the ground cable will be the last one to disconnect. A fuse (6,3A) is placed on the control panel. If the white connection cable is placed on terminal number 7, then the built-in pump 2 works as a radiator pump. That is the situation as delivered from the factory. If the white connection cable is placed on terminal 8, the built-in pump 2 works for the supply of the hot water tank. Then the radiator pump shall be connected to terminal number 4,5,6. Please see pictures 4 and 5 in chapter 11. The burner is electrically connected to the terminal board from the factory. White connection cable 1. Power supply 230 V 2. Pump (built-in) 3. Remote control of the pump (room thermostat) 4. Radiator pump 5. Heat exchanger for domestic hot water (optional) 6. Signal on terminal number 9 will engage pump for the hot water tank 7. Hot water priority relay (use it only when you have heat exchanger and mixing valve installed) 8. Place for terminal block optional heating control system 14 1(4) 161 215 06 02-01

03 ELECTRICAL INSTALLATION 3.2 Electrical diagram D-580070: CTC 950 S1 Main switch for boiler S2 TÜV switch H3 Lamp safety thermostat H4 Lamp burner fault S5 Switch for burner S6 Switch for circulation pump STB Safety thermostat TR Control thermostat Si Fuse BR Eurostecker for burner REG Terminal block (regulation) VVX Micro switch heat exchangr (option) PUMP Pump for radiator system, if cable is on no 7. PUMP Pump for hot water tank, if cable is on no 8. 15 2(4) 161 215 06 02-02

03 ELECTRICAL INSTALLATION 3.3 Electrical diagram D-580097: CTC 950 with hot water tank and mixing valve S1 Main switch for boiler S2 TÜV switch H3 Lamp safety thermostat H4 Lamp burner fault S5 Switch for burner S6 Switch for circulation pump STB Safety thermostat TR Control thermostat S1 Fuse8 BR Eurostecker for burner REG Terminal block (regulation) VVX Micro switch heat exchangr (option) PUMP Pump forhot water tank Signal on terminal No 9 will start the pump for hot water tank 16 3(4) 161 215 06 02-02

03 ELECTRICAL INSTALLATION 3.4 Electrical diagram D-580098: CTC 950 with heat exchanger, DHW priority relay and mixing valve S1 Main switch for boiler S2 TÜV switch H3 Lamp safety thermostat H4 Lamp burner fault S5 Switch for burner S6 Switch for circulation pump STB Safety thermostat TR Control thermostat S1 Fuse BR Eurostecker for burner REG Terminal block (regulation) VVX Micro switch heat exchanger PUMP Pump for heat exchanger 17 4(4) 161 215 06 02-02

04. OPERATION 4.1 Control panel 1. Main switch for boiler Connects / Disconnects the electrical power to the boiler. Indicates with green color when power is on. 2. TüV Switch Used by serviceman for checking the safety thermostat. 3. Indicating lamp safety thermostat 4. Indicating lamp burner fault This lamp lights up when the burner locks out. Push the reset button on the control box at the burner, then the burner should start and the lamp goes out. If the problem still remains, contact a service man. 5. Switch burner 7. Boiler thermometer Shows the boiler water temperature 8. Fuse 6,3 A Open the fuse holder by using a screwdriver to dismantle the top 9. Safety thermostat The safety thermostat disconnects the electrical power if the boiler is overheated. Reset by pushing the button, which is located under the cover, when the temperature is below 65 C. 10.Control thermostat For adjusting the boiler water temperature. The recommended temperature is marked on the scale. 11. Space for regulation (optional) 6. Switch circulation pump The circulation pump for the radiator system connects and disconnects with this switch 18 1(2) 161 305 03 02-01

04. OPERATION 4.2 Start-up - Check that the boiler and radiator system are filled with water. - Vent the boiler by opening by hand the safety valve on the top of the boiler. Make a subsequent filling of the system when needed. - Check that all tube connections are tight and that the connections for chimney and combustion are correctly performed. - Check that the oil pipes of the oil burner are correctly performed and that there is oil in the tank. - Adjust the thermostat within the recommended range - Put the main switch of the switch panel to position 1. - Put the burner switch to position 1. - Check that the burner starts immediately. The burner is factory set. - Put the switch for the circulation pump into position1. - When the boiler and the radiator system have reached the working temperature, make a new venting through the safety valve. 19 2(2) 161 305 03 02-01

05. ASSEMBLY INSTRUCTION BOILER 1 2 3 4 5 6 20 1(7) 161 345 03 02-01

05. ASSEMBLY INSTRUCTION BOILER 7 8 9 10 11 12 21 2(7) 161 345 03 02-01

06. ASSEMBLY INSTRUCTION PIPE KIT 6.1 Assembly instruction pipe kit (579990301) 1 2 3 4 5 22 3(7) 161 345 03 02-01

06. ASSEMBLY INSTRUCTION PIPE KIT 6.2 Assembly instruction pipe kit (580035301) 1 2 3 4 5 6 23 4(7) 161 345 03 02-01

07. ASSEMBLY INSTRUCTION HEAT EXCHANGER (579970301) 1 2 3 4 5 24 5(7) 161 345 03 02-01

07. ASSEMBLY INSTRUCTION HEAT EXCHANGER (579970301) 6 7 8 9 10 25 6(7) 161 345 03 02-01

08. ASSEMBLY INSTRUCTION HOT WATER PRIORITY RELAY (580166402) Must be used when using heat exchanger and mixing valve. 1 2 3 4 5 Connect acc to Electrical diagram D-580098 26 7(7) 161 345 03 02-01

09. SERVICE OIL BURNER 1 2 3 4 5 6 27 1(3) 161 425 04 02-01

10. SERVICE BOILER 1 2 3 4 5 6 28 2(3) 161 425 04 02-01

11. SERVICE CHECK AND ELECTRICAL INSTALLATION 1. Turn the safety valve a few times a year to check the operation of the safety valve. 2. A space in the front part of the boiler is provided in the cleaning door to proceed to measurements. 3. Open cover to proceed to electrical installation. 4. White connection cable. 5. White connection cable. 29 3(3) 161 425 04 02-01

12. CHIMNEY SOLUTIONS 12.1 Balanced flue system 80/125 The installation must be performed according to the local regulations. We reccomend to use the chimney solution according to figure A if possible. A B Max 3 meter Max 7 meter (including horisontal length) 30 1(2) 161 365 05 02-01

12. CHIMNEY SOLUTIONS 12.2 Separate flue outlet (80 mm) and air inlet (80 mm) The installation must be performed accordingly to local regulations. Max 12 meter (including horisontal length) Max 3 meter 31 2(2) 161 365 05 02-01

161 421 50 10-01 Enertech AB. P.O Box 309 SE-341 26 Ljungby Sweden. www.ctc.se, www.ctc-heating.com