ATS01N212QN soft starter for asynchronous motor - ATS01-12 A V KW

Similar documents
RM4TG20 three-phase network control relay RM4-T - range V

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Three-phase monitoring relay CM-PFE

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Electronic overload relay EF65, EF96 and EF146

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Electronic overload relay EF19 and EF45

Relés e Contatores de Estado Sólido SIRIUS

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Analog signal converters CC-E I/I Current / current isolators

CQM1-SF200/CS1W-SF200

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Power Supplies 3. SDN-P DIN Rail Series

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

38 Series - Relay interface modules A

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Type: DILM32 10(24V50HZ) Article No.:

80 Series - Modular timers 16 A. Features

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Redundancy Module QUINT-DIODE/40

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

48 SERIES Relay interface modules 10 A

Safety technique. Emergency stop module BO 5988 safemaster

MasterINTERFACE 39 Series - Relay interface modules

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

PHOENIX CONTACT Features

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Type: DILM9 10(24VDC) Article No.:

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

38 Series - Relay interface modules A

MasterINTERFACE 39 Series - Relay interface modules

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

R.C.C.B. s two-pole LEXIC

PSR The compact range Description

Cross-beam scanning system to detect slim objects. 100 mm in

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Bimetallic Overload Relay Specifications

CompactLogix Power Supplies Specifications

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Digital input modules

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

STRATO LED Drivers 70W, Single output

80 Series - Modular timers 16 A. Features

Power Thyristor TS3 (SP) 3ph. Installation Guide

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Softstarters Type PSR

Manual motor starter MS116

49 Series - Relay interface modules A. Features

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Thermistor motor protection

E-STOP relays, safety gate monitors

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Waveguide Access Point WGA631. Product Guide

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

DS 600. A contact free flux gate based current measurement sensor 600A rms

PNOZsigma - Base units

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

Operating Manual UWAPS-TINY Series

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Transcription:

Characteristics soft starter for asynchronous motor - ATS01-12 A - 380..415V - 5.5 KW Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 01 Product or component type Product destination Product specific application Component name Network number of phases Soft starter Asynchronous motors Simple machine ATS01 3 phases Power supply voltage 380...415 V (- 10...10 %) Motor power kw Icl nominal current 5.5 kw at 380...415 V 3 phases 12 A Utilisation category AC-53B conforming to EN/IEC 60947-4-2 Current at nominal load Type of start Power dissipation in W With heat sink Integrated bypass 342...456 V Power supply frequency 50...60 Hz (- 5...5 %) Power supply frequency limits Output voltage Control circuit voltage Starting time Deceleration time symb Starting torque 47.5...63 Hz <= power supply voltage Built into the starter Adjustable from 1 to 10 s Adjustable from 1 to 10 s 60 A at nominal load Start with voltage ramp 4 W at full load and at end of starting 124 W in transient state 30...80 % of starting torque of motor connected directly on the line supply Discrete input type (LI1, LI2, BOOST) stop, run and boost on start-up functions logic <= 8 ma 27 kohm Discrete input voltage 24...40 V Discrete input logic (LI1, LI2, BOOST) positive state 0 < 5 V and < 0.2 ma, state 1 > 13 V and > 0.5 ma Discrete output current Discrete output type Discrete output voltage Minimum switching current Maximum switching current Display type Tightening torque 3 A AC-15 2 A DC-13 (R1A, R1C) relay outputs NO (LO1) open collector logic end of starting signal 24 V (6...30 V) open collector logic Relay outputs 10 ma 6 V DC Relay outputs 2 A 30 V DC inductive load, cos phi = 0.5 L/R = 20 ms Relay outputs 2 A 250 V AC inductive load, cos phi = 0.5 L/R = 20 ms 1 LED (yellow) for nominal voltage reached 1 LED (green) for starter powered up 0.5 N.m 1.9...2.5 N.m The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Aug 7, 2016 1

Electrical connection Marking Operating position Height Width Depth Product weight 2 conductor(s) flexible cable without cable end, connection via screw connector 0.5...1.5 mm² / AWG 16 for control circuit 2 conductor(s) flexible cable without cable end, connection via 4 mm screw clamp terminal 1.5...6 mm² / AWG 10 for power circuit 2 conductor(s) flexible cable with cable end, connection via 4 mm screw clamp terminal 1...6 mm² / AWG 10 for power circuit 1 conductor(s) flexible cable without cable end, connection via screw connector 0.5...2.5 mm² / AWG 14 for control circuit 1 conductor(s) flexible cable without cable end, connection via 4 mm screw clamp terminal 1.5...10 mm² / AWG 8 for power circuit 1 conductor(s) flexible cable with cable end, connection via screw connector 0.5...1.5 mm² / AWG 16 for control circuit 2 conductor(s) rigid cable, connection via screw connector 0.5...1 mm² / AWG 17 for control circuit 2 conductor(s) rigid cable, connection via 4 mm screw clamp terminal 1...6 mm² / AWG 10 for power circuit 1 conductor(s) rigid cable, connection via screw connector 0.5...2.5 mm² / AWG 14 for control circuit 1 conductor(s) rigid cable, connection via 4 mm screw clamp terminal 1...10 mm² / AWG 8 for power circuit CE Vertical +/- 10 degree 124 mm 45 mm 131 mm 0.42 kg Environment Electromagnetic compatibility Voltage/Current impulse conforming to IEC 61000-4-5 level 3 Micro-cuts and voltage fluctuation conforming to IEC 61000-4-11 Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3 level 3 Immunity to electrical transients conforming to IEC 61000-4-4 level 4 Immunity to conducted interference caused by radio-electrical fields conforming to IEC 61000-4-6 level 3 Harmonics conforming to IEC 1000-3-4 Harmonics conforming to IEC 1000-3-2 EMC immunity conforming to EN 50082-2 EMC immunity conforming to EN 50082-1 Electrostatic discharge conforming to IEC 61000-4-2 level 3 Damped oscillating waves conforming to IEC 61000-4-12 level 3 Conducted and radiated emissions conforming to IEC 60947-4-2 level B Conducted and radiated emissions conforming to CISPR 11 level B Standards EN/IEC 60947-4-2 Product certifications IP degree of protection B44.1-96/ASME A17.5 for starter wired to the motor delta terminal CCC CSA C-Tick GOST UL IP20 Pollution degree 2 conforming to EN/IEC 60947-4-2 Vibration resistance 1.5 mm peak to peak (f = 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f = 13...150 Hz) conforming to EN/IEC 60068-2-6 Shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27 Relative humidity 5...95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 Ambient air temperature for operation 40...50 C with current derating of 2 % per C -10...40 C without derating Ambient air temperature for storage -25...70 C conforming to EN/IEC 60947-4-2 Operating altitude > 1000 m with current derating of 2.2 % per additional 100 m <= 1000 m without derating 2

Dimensions Drawings Dimensions Mounting on Symetrical (35 mm) Rail Screw Fixing (1) Retractable fixings 3

Connections and Schema Example of Manual Control A1 : Soft start/soft stop unit (1) For type 2 coordination Q1 : Motor circuit-breaker F3 : 3 fast-acting fuses 4

Technical Description Function Diagram 2-wire Control with Deceleration Us : Power supply voltage LED Green LED 1 : LI2 : Logic input R1 : Relay output LO1 :Logic output LED Yellow LED 2 : 3-wire Control with Deceleration Us : Power supply voltage LED Green LED 1 : LI2, Logic inputs LI1 : R1 : Relay output LO1 :Logic output Um : Motor voltage LED Yellow LED 2 : 5

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Schneider Electric: