RLD-H10G Refrigerant Leak Detectors

Similar documents
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Recharge Procedure for Telemark TVP-2000 and TVP-3500

el-720 Carbon Dioxide Gas Leak Detector User s Guide

EzFlex Combustible Gas Leak Detector Model EZ40

WSD130 SOLDERING STATION

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Ozone Generator Manual

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Meaco 30L and Meaco 40L dehumidifier instruction manual

Combustible Gas Leak Detector 720b

G670 Intermittent Pilot Ignition Controls

12-Volt 10-Amp Regulated Power Supply

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

MCR1900 Media Converter 19-Slot Chassis

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

A99B Series Temperature Sensors

Dehumidifier Users manual. For Models: DH45S DH65S

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

AutoRanging Digital MultiMeter

Manual Ranging MultiMeter

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

National- Spencer Inc.

How To Use A Cdm250 Digital Multimeter

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Powers Controls TH 192 S Single Temperature Room Thermostat

Global Water Instrumentation, Inc.

Bottom Loading Water Dispenser

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

T-4000 Series Room Thermostat Adjusting Instructions*

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

CARING FOR YOUR WATER HEATER

PORTABLE AIR CONDITIONER

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Safety, Operation and Maintenance Manual with Parts List

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

OPERATING INSTRUCTIONS

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

DiscovR R134a Refrigerant Identifier

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Mini-led spotlight with magnetic base

7 FUNCTION DIGITAL MULTIMETER

COMPANION 20 MULTIMEDIA SPEAKER SYSTEM. Owner s Guide Guía de usuario Notice d utilisation

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Nokia Bluetooth Headset BH-104

Cable Tester Pro ORDERCODE D1909

Operations and Maintenance Manual

Tablet Management Rack 16

Troubleshooting Guide for Dispenser Model #900172

Measurement Solutions for Refrigeration Technology.

Nokia Bluetooth Headset BH /1

FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL

COMPRESSED AIR DRYER

Nokia Bluetooth Headset BH-607. Issue 2. 1

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

The Storm 20-Gallon Wet/Dry Vac

Digital Photo Picture Frame. Operation Manual

Instructions For SF 6 Refill Kit

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

User Manual for CH-PFC76810

UV100A Ultraviolet Air Treatment System

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

GENANO 4500 MEDICAL AIR PURIFICATION DEVICE

Operating Instructions Split System Air Conditioner

GenStore Archive Cabinet

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Replacing the vacuum tube

DISSOLVED OXYGEN PROBE

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

CG PTFE Diaphragm Liquid Transfer Pump

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

, User s Manual

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Nokia Bluetooth Headset BH-102. Issue 1

HYLA NST Cleaning System

American DJ. Roto-Balls VS MKII. User Instructions. American DJ

User and Installation Guide

Transcription:

Product/Technical Bulletin RLD-H10G Issue Date September 8, 2008 RLD-H10G Refrigerant Leak Detectors The RLD-H10G is a professional grade leak detector for use by refrigeration and air conditioning technicians. This detector senses all CFC, HCFC, and HFC refrigerants and blends, such as R12, R502, R22, R404a, R507, and R134a, among others. The RLD-H10G plugs into a 120 VAC outlet. A full line of accessories and maintenance kits is also available, including replacement sensors, tune-up kits, probe extensions, and leak vials. Figure 1: RLD-H10G Leak Detector Features and Benefits Positive Ion Emission Heated Diode Sensor Halogen Selective Sensing High Quality Air Pump Visual and Audible Signal Exceeds SAE J1627 Moving Probe Specification External Calibration Source Provides the most sensitivity available today, while still detecting all halogenated refrigerant gases Eliminates many sources of possible false alarms due to background contamination Supplies constant air flow to sensor so it responds quickly to leaks; also helps sensor recover quickly after exposure to refrigerant so leak can be verified Facilitates sensing in noisy equipment rooms with 360 visibility and piercing tone; Frequency of noise/light indicates magnitude of leak Minimizes service time because the leak is found the first time, is verifiable, and the fix can be confirmed Indicates when the sensor is working properly and serves as a reference point to judge leak size 2008 Johnson Controls, Inc. 1 Part No. 24-7929-39, Rev. B Code No. LIT-125602

Application Overview Growing concern over the effects of certain refrigerants on the atmosphere has generated a strong motive to eliminate system leaks and to develop safer refrigerants. With the RLD-H10G, you can be confident that your instrument will provide the sensitivity and capabilities to meet your service needs today and for the years to come. The RLD-H10G is intended principally as a service technician s tool. This detector has the capability to detect small amounts of halogenated gases, including chlorine and fluorine based refrigerants and blends. Theory of Operation The leak detector consists of a control unit with a manual balancing circuit, a probe with a 4.5 ft cable, and a 6 ft power cord. The sensor uses positive ion emission technology, which is based on the ionization characteristics of alkali metals. The alkali metals act as the cathode of a diode, and the anode is heated by a DC voltage. Air from the area being leak checked is pumped from the probe and into the space between the cathode and anode. If halogen gas is present, it creates an ionized current between the cathode and the anode, which is amplified to sound a speaker and light a neon lamp in the probe. Sensitivity can be controlled by adjusting the current (temperature) through the sensor. Dimensions Accessories Figure 3: RLD-H10-100--14 in. Flexible Probe Extension Figure 4: RLD-H10-600R--Tune-up Kit; includes sensor, 100 filters, 4 airflow indicator balls, 3 rubber probe tips, and leak vial Figure 5: RLD-H10-601R--Replacement Sensor 5.0 127 2.8 71 8.8 224 Figure 2: RLD-H10G Dimensions (in/mm) rldh10g Figure 6: RLD-H10-602R--Maintenance Kit; includes 100 filters, 4 airflow indicator balls, 3 rubber probe tips Figure 7: RLD-H10-603R--Replacement Leak Vial 2 RLD-H10G Product/Technical Bulletin

Operation! WARNING: Personal Injury Hazard. Do not use the RLD-H10G in an explosive or combustive atmosphere. The ambient atmosphere is drawn through the probe and over the sensor, which operates at approximately 1000 F (540 C). The resulting hot mixture of air and combustible gas could explode.! CAUTION: Equipment Damage Hazard. To avoid equipment damage, operate the RLD-H10G on the proper supply voltage, as given on the rating plate. 1. Plug the cord into a 120 VAC, 60 Hz outlet. 2. Flip power switch to On position. (See Figure 8.) 3. Slide range switch to small (SM) leak position. (See Figure 8.) 4. Check for sufficient airflow by pointing the probe tip toward the floor and observing the airflow ball in the probe. (See Figure 9.) If the airflow is sufficient, the ball will rise and float a small distance above the tip of the probe. If the ball does not rise, tap the probe lightly to make sure it is not sticking. If the ball still does not rise, check the filter in the probe tip as described in the Maintenance section. Figure 8: RLD-H10G Faceplate (Sensor heat control adjustment is on the bottom of the unit.) Figure 9: Verifying Airflow 5. Allow two minutes for the sensor to warm up. When the sensor is warm, the light and sound indication should idle at around three or four beats per second. The balance control (see Figure 8) may be used to adjust the idle rate. 6. Proceed to the Calibration and Verification section. RLD-H10G Product/Technical Bulletin 3

Calibration and Verification The leak vial may be used as often as necessary to assure proper operation of the RLD-H10G, and to assist in determining the size of the leak. When using the small leak range position, a leak of HFC causing an audible signal equal to that produced by the leak vial has a leak rate of approximately one-half ounce/year. When using the medium leak range position on a CFC or HCFC system, this leak rate would also be approximately one-half ounce/year. Proper unit response during the calibration test verifies sensitivity and operation for all three test positions. 1. Ensure that the range switch is in the small (SM) position and idling at three or four beats per second. (See Figure 8.) 2. Remove the black, sticky-label disc from the cap of the leak vial and discard. Allow a few minutes for the leak rate to stabilize. Do not attempt to unscrew the cap, as you may damage the bottle. The vial contains enough refrigerant to last for approximately six months. 3. Test operation by briefly moving the probe tip over the opening of the leak vial as if you are trying to locate this leak. It is not necessary to hold the probe over the leak, as this does not simulate field conditions. 4. The RLD-H10G should respond with an increase in flash rate and sound, verifying operation and indicating the location of the leak. 5. If the RLD-H10G does not respond to the leak vial, make sure there is liquid in the bottle. If the unit still does not respond to the leak, increase the sensor heat slightly by turning the sensor heat control knob (on the bottom of the unit) 1/16th of a turn clockwise. 6. Allow a minute for the sensor to heat, then repeat the calibration procedure. Tips for Finding Leaks Use the black rubber probe tip whenever possible and hold the probe approximately 1/4 in. above the area being tested. Move the probe tip at about two inches per second along seams or joints suspected of leaking. Start leak checking anywhere, and continue in a logical progression through the entire system to locate all leaks. Set the range switch to the appropriate range to ensure maximum sensor life. If the leak size is unknown, start at the large (LG) leak setting. Adjust the balance control to maintain slow ticking (three or four ticks per second) in the idle state. (See Figure 8.) IMPORTANT: Exposing the sensor to large amounts of refrigerant or holding the probe over a leak for a long period of time will significantly shorten sensor life. On CFC and HCFC systems, the medium (MED) range is sufficient to verify that the system is free of leaks that require fixing. On HFC systems, use the small (SM) range to verify that the system is free of leaks that require fixing. Replace the filter often (as described in the Maintenance section) to retain airflow and sensitivity. Wipe all surfaces to be tested with a clean, dry cloth. Check ports for moisture before inserting the probe.! CAUTION: Equipment Damage Hazard. Submerging the probe in liquid will damage the vacuum pump. 4 RLD-H10G Product/Technical Bulletin

Maintenance Replacing the Filter and Airflow Indicator To protect the air pump from damage due to foreign particles and moisture, replace the filter as it becomes dirty. With moderate use (15-30 minutes per day), replacing the filter once a month is recommended. In dirty environments or with heavy use, replace the filter more frequently. Replace the filter whenever it is visibly dirty or wet. Replacing the Filter 1. Remove the black rubber probe tip. 2. Pick out the filter with a pin or tweezers. A fine screen will remain in the tip of the probe. 3. Insert the new filter in the probe end. (See Figure 10.) Make sure that the filter is firmly seated against the fine screen. 4. Replace the rubber probe tip. Replacing Airflow Indicator 1. Remove the clear plastic section of the probe by gently pulling on the white rubber grip. (See Figure 10.) 2. Turn the probe upside-down and tap on it to remove the old airflow indicator ball. 3. Insert the new airflow indicator ball into the probe. 4. Reattach the probe end to the hose. Replacing the Sensor The sensor is a plug-in unit that is thrown away when expended. It needs replacement when the RLD-H10G no longer responds to the leak vial, even with the sensor heat control turned fully clockwise. (Make sure the leak vial contains some refrigerant.)! CAUTION: Personal Injury Hazard. Sensor surface temperature may reach 200 C (390 F) during operation, and may cause a burn if not allowed to cool. 1. Turn the leak detector off. 2. Unplug the power cord and open the sensor cover. The sensor is now visible. (See Figure 8 and Figure 11.) 3. Allow the sensor to cool before handling it (approximately 15 minutes). 4. Unplug and discard the sensor. 5. Insert a new sensor and close the sensor cover. 6. Turn the sensor heat control knob (on the bottom of the unit) to its full counterclockwise position. 7. Turn the unit on, and calibrate the new sensor. (See instructions in the Calibration and Verification section.) Figure 10: Replacing the Filter and Airflow Indicator Figure 11: Replacing the Sensor RLD-H10G Product/Technical Bulletin 5

Troubleshooting Table 1: Troubleshooting Problem Cause Solution Responds to leak vial on large (LG) leak setting Heat control set too high Decrease the sensor heat slightly by turning the sensor heat knob (on the bottom of the unit) 1/16th of a turn counterclockwise. Allow a minute for the sensor to cool, then repeat calibration. No response to leak vial Leak vial empty Reorder leak vial (RLD-H10-603R). Audio normal; probe lamp does not flash Responds continuously in all leak positions Responds continuously on small leak position Balance control will not stop response away from leak No air flow (Airflow indicator ball in probe does not float.) Sensor exposed to excessive amounts of halogen gas Water in probe Heat control set too low Burned-out or damaged probe lamp Dirt in sensor Short circuit in sensor Excessive sensitivity Atmosphere contaminated with excessive halogen gas Replace filter in probe tip (RLD-H10-602R). Check pump operation. Move probe to clean atmosphere for several minutes while sensor purges itself. Recalibrate in clean area. While unit is operating, blow clean air (5 psig) into the probe tip for approximately one minute or blow (by mouth) as hard as possible into probe tip for one or two minutes. Replace the filter (RLD-H10-602R). Increase the sensor heat slightly by turning the sensor heat knob (on the bottom of the unit) 1/16th of a turn clockwise. Allow a minute for the sensor to heat, then repeat calibration. Return unit to your Johnson Controls representative. Remove sensor (see Figure 11) and blow it out with clean air (not over 10 psig). If unsuccessful, replace sensor (RLD-H10-601R). Replace the filter (RLD-H10-602R). Replace sensor (RLD-H10-601R). Decrease the sensor heat slightly by turning the sensor heat knob (on the bottom of the unit) 1/16th of a turn counterclockwise. Allow a minute for the sensor to cool, then repeat calibration. Ventilate area. Switch to large (LG) leak setting. (See Figure 8.) Reduce sensor heat if unit still responds excessively at large leak rate setting. 6 RLD-H10G Product/Technical Bulletin

Ordering Information Table 2: Ordering Information Item Description RLD-H10G-1 RLD-H10-100 RLD-H10-600R RLD-H10-601R RLD-H10-602R RLD-H10-603R Refrigerant leak detector with 120 VAC power cord 14 in. flexible probe extension Tune-up kit; includes sensor, 100 filters, 4 airflow indicator balls, 3 probe tips, and leak vial Replacement sensor Maintenance kit; includes 100 replacement filters, 4 airflow indicator balls, and 3 probe tips Replacement leak vial (contains enough refrigerant to last approximately six months) Repair Should it become necessary to repair your RLD-H10G, please contact your Johnson Controls representative. Warranty Repairs Units under warranty will be shipped to Johnson Controls for repairs. The repairs will be completed within 24 hours after receipt by the repair center, and the unit will be returned to your Johnson Controls representative at the same priority of shipment with which it was received. Non-Warranty Repairs Units that are no longer under warranty will be repaired to factory specifications for a nominal fee. The repairs will be completed within seven days after receipt by the repair center, and the unit will be returned to your Johnson Controls representative at the same priority of shipment with which it was received. RLD-H10G Product/Technical Bulletin 7

Technical Specifications Product Power Requirements Sensing Element Type RLD-H10G Refrigerant Leak Detector 120 VAC at 60 Hz Positive Ion Emission Heated Diode Approximate Sensitivity Switch Position Alarm Sensitivity (moving probe) Leak Alarm Response Time Warmup Time Accuracy Small >0.05 oz per year CFC or HCFC >0.5 oz per year HFC Medium >0.5 oz per year CFC or HCFC >1.0 oz per year HFC Large >3.0 oz per year CFC or HCFC >5.0 oz per year HFC Audible alarm, visible neon lamp Approximately 1 second Approximately 2 minutes Meets SAE J1627 test requirements Probe Length Approximately 4.5 ft (1.4 m) Ambient Operating Conditions Ambient Storage Conditions Case Dimensions (H x W x D) Shipping Weight 32 to 113 F (0 to 45 C); 5-90% RH, non-condensing 14 to 140 F (-10 to 60 C); 5-90% RH, non-condensing Vinyl 2.8 x 8.8 x 5.0 in. (71 x 224 x 127 mm) 3.2 lb (1.4 kg) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. 8 RLD-H10G Product/Technical Bulletin Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Johnson Controls is a registered trademark of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2008 Johnson Controls, Inc.