ACCUMULATION TANKS with DHW stainless-steel heat exchanger HSK 500, HSK 800, HSK 1000, HSK 1500, HSK 2000

Similar documents
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Solar Hot Water Heaters

Operators manual Basic water heater

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

ECOplus Solar Cylinder

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Description of functions

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

Isotemp Basic, Slim/B & Slim Square

SF15K SF05KSS, SF10KSS

ECOCIAT. Domestic hot water heat recovery unit

Laddomat Charging unit

SERVICE MANUAL Order No.WH0911S001V0

Select Radiators Installation Guide

SunMor SM-V30 Solar Water Heater Installation Manual

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

FLASH TANK ECONOMIZER PRODUCT GUIDE

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Installation and maintenance instructions

1 DESCRIPTION OF THE APPLIANCE

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Link-Up. Solid Fuel Association Guide to Central Heating.

Please keep these operating instructions in a safe place.

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

SunMaxx Solar Filling Station Operating Instructions

building engineering services association specification for: Domestic Heating

Cooling system components, removing and installing

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Cooling system components, removing and installing

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

STATIONARY WATER HEATERS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Getting the best from your urn

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Overheating limit control

SOLAR HEATING SYSTEMS.


Portable Air Conditioner

Session 2: Hot Water Supply

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

UNDERSTANDING CENTRAL HEATING SYSTEMS

Meaco 30L and Meaco 40L dehumidifier instruction manual

Operating instructions

How To Use An Akua Magnetic Lime Scale Preventing Device

INFRARED QUARTZ WALL HEATER

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Munchkin Heat Exchanger Maintenance

Draining and filling cooling system

ELECTRIC INSTANTANEOUS WATER HEATER

Air Conditioner Water Heater Model ACWH18

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

SWIMMING POOL HEAT PUMP

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Natural geothermal energy.

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

Zenith Solar thermal 4.5m pump station Installation manual

Light Duty Commercial Electric Water Heater

ASME Packaged Indirect Fired Water Heater

ELECTRIC CENTRAL HEATING FLOW BOILER

Hydrocollator. Operation Manual SS E-2 E and 220/240 Volt Units.

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating!

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Screw Plug Immersion Heaters

Coolflo Safe Touch Shower Mixing Valve ST20015CP

2-SLICE COOL TOUCH TOASTER

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

CHEMICAL CLEANING UNIT Product number:

Commercial Electric Water Heater

Technical data. Danfoss DHP-A

Electric Flow Boiler

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Power consumption (kw)

ENGINE COOLING SYSTEM

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Technical Data Manual Model Nos. and pricing: see Price List

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

OPERATION AND INSTALLATION MANUAL

Please also see 10 golden rules for correct Saniflo installation on

USER MANUAL INSTALLATION INSTRUCTION WARRANTY REGISTER. Free Hot Water Solar Storage Tank (SST) with Single/Double coil heat exchanger

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

SOLAR WATER HEATER USER AND INSTALLATION MANUAL

the Soft Top Breville Customer Service Center Instruction Book - Livret d instructions

Electric Water Heater

Thermo Siphon Solar Systems

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.7

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Transcription:

Owners Manual ACCUMULATION TANKS with DHW stainless-steel heat exchanger HSK 500, HSK 800, HSK 1000, HSK 1500, HSK 2000 EN v. 1.1

CONTENTS 1. Description... 3 1.1 Models... 3 1.2 Tank protection... 3 1.3 Thermal insulation... 3 1.4 Connection points on the tank... 3 1.5 Packing... 3 2. General Information... 3 3. Technical Data and Dimensions of HSK Models... 4 4. Operation... 5 5. Examples of Assigning Connection Points... 5-6 6. Installation and Commissioning... 7 7. Installing Insulation on the Tank... 8-9 8. Maintenance... 10 9. Disposal... 10 10. Recommended Accessories... 10 10.1 Electric heating rods... 10 10.2 Heat exchanger for DHW recirculation... 11 10.3 Watersoft N electromagnetic water treatment device... 12 10.4 Additives for heating systems... 12 2

1. Description HSK Accumulation Tanks are intended for accumulation and subsequent distribution of thermal energy of heating water. They are equipped with an immersed DHW stainless-steel heat exchanger (further DHW only), a stratification cylinder for the heating circuit return line, two steel heating coils (e.g. for connecting solar collectors), with the possibility to insert an el. heating rod, and enabling to connect further heat sources. The accumulation tank shall be always connected to a closed heating circuit. The tanks are further fitted with two G 6/4 sleeves for connection to heat sources, four G 1/2 sleeves to accommodate probe sheaths and 6 sleeves for other heat sources. The G 6/4 sleeves can be used for direct installation of el. heating rods. The tanks have one sleeve on the top for an air vent valve, five G 6/4 side sleeves for connection to a heating system, one G 6/4 side sleeve for installation of an el. heating rod, six side sleeves with 1/2 thread for placing sensors and four threaded G 1 side sleeves for connecting two heating coils. For proper operation of a tank, it is necessary to have a hydraulic design of the entire heating system, i.e. position of circulation pumps for both heat sources and heating circuits, valves, clack valves etc. When more heat sources shall be combined, it is recommended to use an intelligent controller, e.g. Regulus IR09 KTP, for both the source and consumer sides of a heating circuit, i.e. also for charging and discharging an accumulation tank. 1.1 Models Five models of 500, 800, 1000, 1500 and 2000 l capacity with a stainless steel DHW heat exchanger. 1.2 Tank protection The accumulation tank has no inner surface finish, the outer surface is painted in gray. The DHW heat exchanger is made of stainless steel. 1.3 Thermal insulation For easy handling, tanks are supplied with a detachable soft insulation 120 mm thick, with a zippered leatherette mantle. 1.4 Connection points on the tank 1x upper sleeve with G 1 inner thread 6x side sleeve with inner thread 6x (7x) side sleeve with G 1/2 thread 4x G 1 side sleeve 2x G 5/4 side sleeve 1.5 Packing Tanks are delivered standing, each screwed to its pallet, packed in bubble wrap. 2. General Information This Owners Manual is an integral and important part of the product and must be handed over to the User. Read carefully the instructions in this Manual as they contain important information concerning safety, installation, operation and maintenance. Keep this Manual for later reference. The appliance shall be installed by a qualified person according to valid rules and Manufacturer s Instructions. This appliance is designed to accumulate heating water and distribute it subsequently. It must be connected to a heating system and heat sources. This appliance is suitable for continuous heating of domestic hot water. Using the accumulation tank for other purposes than above described is forbidden and the manufacturer accepts no responsibility for damage caused by improper or wrong use or filling procedure. The appliance shall be installed by a qualified person according to valid rules, otherwise the warranty becomes null and void. 3

3. Technical Data and Dimensions of HSK Models G 1 20 1 A B C D E F G 5/4 G 1/2 G 1/2 el. top. těleso G 1/2 2 3 4 5 6 21 20 19 18 17 15 16 14 13 12 11 G 1 G 1/2 G 1/2 G 1 G 1/2 G 1 G 1/2 Q R S T V U G H I ø W ø X G 5/4 G 5/4 7 8 ø V 10 9 Insulation G 1 16 J K L 30 M N O P Tank code... a Insulation code... b Total volume - tank + DHW heat exch.... c Tank volume... d Volume - DHW heat exch.... e Volume - upper coil... f Volume - lower coil... g Surface - upper coil... h Surface - lower coil... i Surface - DHW heat exch.... j Max. working temperature - tank+h.exch.... 95 C Max. working pressure - DHW h.exch.... 6 bar Max. working pressure - tank... 6 bar Empty weight... k Model HSK 500 HSK 800 HSK 1000 HSK 1500 HSK 2000 Tank code a 7662 7663 7506 7686 7687 Insulation code b 7664 7665 7507 7688 7689 Total volume - tank + DHW heat exch. [l] c 488 805 897 1478 1915 Tank volume [l] d 443 750 842 1408 1825 Volume - DHW heat exch. [l] e 45 55 55 70 90 Volume - upper coil [l] f - 7,8 12,1 12,3 18,1 Volume - lower coil [l] g 10 12,1 12,3 12,3 23,7 Surface - upper coil [m 2 ] h - 2 3 3,5 4,2 Surface - lower coil [m 2 ] i 2,3 3 3,5 3,5 5,5 Surface - DHW heat exch. [m 2 ] j 5,7 7,2 7,2 8,5 11,5 Empty weight [kg] k 130 200 250 285 325 Dimensions [mm] A 1720 1930 2110 2240 2380 B 1640 1830 2010 2120 2260 C 1420 1580 1760 1825 1950 D 1150 1290 1500 1500 1730 E - - - - 1470 F 820 920 1130 1130 1210 G 440 570 580 600 750 H 240 270 270 335 350 I 190 220 220 285 300 J 150 170 170 235 250 K 280 310 310 375 390 L 490 465 495 520 630 M 700 670 730 765 870 N 800 770 840 875 970 O 910 870 950 975 1080 P 1020 980 1060 1085 1190 Q 1150 1090 1210 1195 1300 R - - - 1305 1410 S - 1190 1350 1415 1520 T - 1290 1450 1525 1640 U 1400 1390 1520 1635 1760 V - 1500 1680 1745 1870 ø W 850 1030 1030 1240 1340 ø X 650 790 790 1000 1100 4

4. Operation This tank is designed for heating and accumulation of heating water in household or industrial applications, however always in closed pressure circuits with forced circulation. Hot water is heated inside the accumulation tank from several possible heat sources like various kinds of heating boilers, renewable energy sources (heat pumps, solar collectors), or also electric heating elements. The immersed stainless-steel DHW heat exchanger is heated by heating water inside the accumulation tank. The immersed DHW heat exchanger shall be connected to cold water inlet with one 5/4 threaded fittings, and to hot water with the other one. When hot water is drawn from the outlet point, cold water flows into the immersed heat exchanger and heats up from the heating water in the accumulation tank. The accumulation tank shall be connected to heat sources through G 6/4 threaded fittings. A solar system connects to the connection points of the heating coils through G 1 threaded fittings. Individual connection points are assigned according to the circuits to be connected. There is a wide choice of combinations, the following chapter describes just some examples. 5. Examples of Assigning Connection Points Connection point Example I. Solar collector + combination gas boiler + fireplace Example II. Solar collector + heat pump + el. heating rod. Example III. Solar collector + gas boiler + solid fuel boiler. 1 1 plug / recirculation heat exchanger 1 plug / recirculation heat exchanger 1 plug / recirculation heat exchanger 2 outlet to a gas boiler s DHW tank outlet ot a DHW storage tank outlet ot a DHW storage tank 5 plug el. heating rod plug 7 cold water inlet cold water inlet cold water inlet 8 inlet from a manifold, expansion tank, safety valve inlet from a manifold, expansion tank, safety valve inlet from a manifold, expansion tank, safety valve 9 outlet to a fireplace plug outlet to a solid-fuel boiler 10 outlet to solar panels outlet to solar panels outlet from solar panels 12 inlet from solar panels inlet from solar panels inlet from solar panels 14 plug plug plug 15 outlet to a combination gas boiler outlet to a heat pump outlet to a heat pump 16 outlet to solar panels outlet to solar panels outlet to solar panels 17 plug plug plug 20 inlet from a comb. gas boiler, to manifold inlet from a heat pump, to manifold inlet from a gas boiler,solid-fuel boiler 21 inlet from solar panels inlet from solar panels inlet from solar panels 3, 4,6, 11, 13, 18, 19 thermometers, sensors, plugs thermometers, sensors, plugs thermometers, sensors, plugs Connections depend on the circuits to be connected, the a.m. examples are informative only. Example I. Solar collector + combination gas boiler + fireplace. cold water hot water gas boiler with DHW tank T B E A B E 5

Example II. Solar collector + heat pump + el. heating rod. hot water cold water T T B E E Example III. Solar collector + gas boiler + solid fuel boiler. hot water cold water T T B gas boiler E E 6

6. Installation and Commissioning Installation must meet valid rules and may be done only by qualified staff. Defects caused by improper installation, use or handling are not covered by warranty. After the tank is installed and connected to an existing heating system, it is recommended to clean the entire heating system using a suitable cleaning agent, e.g. MR-501/R. Anti-corrosion protective liquid should be also used, e.g. MR-501/F. Connection to heat sources Place the tank on the floor, as close to your heat source as possible. Mount the insulation, cf. Installing Insulation on the Tank. Connect the heating circuit to inlets and outlets respecting the thermal stratification in the tank. Install a drain valve at the lowest point of the tank. Install an air vent valve at the highest point of the system. Insulate all the connecting piping. The tank may be fitted with electric heating rods up to 12kW output. They can be power-supplied either directly (elements with built-in thermostat) or via a controller for the entire heating system. All electric heating elements shall be protected by a safety thermostat. Connection to a solar system The tank can be used with a solar system. In such a case, the inlet for hot heat-carrying liquid coming from the solar system shall be connected to the upper sleeve of the heating coil G 1 and the lower outlet to the return piping to the solar system. Insulate all the piping between the tank and the solar system. Connection to a water pipeline Connect the tank to a water main according to valid rules. Installation of a pressure reducing valve on the tank inlet is recommended. For a water main with pressure above 6 bar a pressure reducing valve is necessary. Should the water be too hard, install a water softener before the tank. In case the water contains mechanical impurities, install a strainer. Commissioning The tank shall be filled up respecting valid standards and rules. In order to minimize corrosion, special additives for heating systems should be used. The quality of heating water depends on the quality of filling water at commissioning, on the topup water and on the frequency of topping up. This has a strong influence on the lifetime of heating systems. Poor quality of heating water may cause problems like corrosion or incrustation, esp. on heat transfer surfaces. The quality of top-up and heating water is set by ČSN 07 7401/1992Sb. Fill the heating circuits with the appropriate fluids and air-bleed the entire system. Check all connections for leaks and verify the system pressure. Set the heating controller in compliance with the documentation and manufacturer s recommendations. Check regularly proper function of all control and adjusting elements. 7

7. Installing Insulation on the Tank Description Thermal insulation is a component of accumulation tanks that prevents heat losses. For these types of accumulation tanks, insulation is supposed to be installed on the spot for easier handling. Insulation made of soft polyurethane foam with a zippered PVC layer is used. Warning Insulation installation shall be done in two or three persons, depending on its size. The zippered soft-foam insulation must not be installed at temperatures below 20 C. If this cannot be avoided, the insulation shall be pre-warmed in another room to at least 20 C. It is impossible to install insulation of lower temperature, there is a risk of damage, esp. to the zipper. Do not use any tools for installation. Keep away from open fire. How to install soft foam insulation with a PVC layer 1. Fix the tank following installation instructions. 2. Wrap the insulation around the tank carefully. Check that the insulation adheres to its body perfectly. This can be reached by rubbing and patting the insulation by hand from its center evenly in both directions until the insulation adheres to the tank s surface completely and no bubbles are left. 3. Use the holes for sleeves as a rest during the insulation installation. 4. At least one person presses the insulation to the tank, pulling both ends together. The other person closes the zipper, see pics. 5. Put on the upper insulation and cover. 6. Push on the covering plastic rosettes depending on the size of sleeves, or put on the flange plug(s) with insulation. 7. Finish the tank installation in compliance with the respective instructions and valid standards and rules. Warranty on insulation Warranty shall become null and void if: the procedure described in the Installation Manual was not respected, the product was used for other purposes than intended. Warranty does not cover: usual wear and tear, damage caused by fire, water, electricity or a natural disaster, defects caused by failure to use the product in compliance with its intended purpose, by improper use and insufficient maintenance, defects caused by mechanical damage to the product, defects caused by tampering or incompetent repair. 8

1 2 3 4 5 6 7 8 Pictures showing how to mount soft-foam insulation with a PVC sheet on a storage water heater. 9

8. Maintenance If the tank is fitted with a heating element, disconnect it from the mains first. Clean the exterior of the tank with a soft cloth and a mild detergent. Never use abrasive cleaners or solvents. Check all connections for leaks. 9. Disposal Packing shall be disposed of in compliance with the valid rules. When the product reaches the end of its life, it shall not be disposed of as household waste. It shall be dropped off at a Local Waste Recycling Center. Insulation shall be recycled as plastic and the steel vessel as scrap iron. 10. Recommended Accessories 10.1 Electric heating rods Electric heating rods can be used in domestic storage water heaters and accumulation tanks. They can be powersupplied either by 230V or 3x230V/400V. Heating rods of output 2-12 kw can be installed into accumulation tanks, into the sleeves with G 6/4 inner thread (the right type should be selected with respect to its length and the tank diameter). Electric heating rods are currently made of nickel-plated copper. They can be also supplied in a copper or stainless-steel version. Heating rods with an integrated electronic thermostat and a safety thermostat are also available. G 6/4 thread, nickel-plated copper power output (kw) voltage (V) length l (mm) code 2 230 270 6146 3 230 240 6063 4.5 3 x 230 333 6064 6 3 x 230 428 6065 L 75 7.5 3 x 400 520 6066 9 3 x 400 615 6067 12 3 x 400 750 7032 G 6/4 thread, stainless steel, thermostatic head, adjustable by a knob (K) or screwdriver (S) adjustment power output (kw) voltage (V) length l (mm) code K 2 230 405 8248 K 3 230 408 8249 S 2 230 405 8250 L 108 S 3 230 408 8252 G 6/4 thread, nickel-plated copper, thermostatic head power output (kw) voltage (V) length l (mm) code 4.5 3 x 230 333 7034 L 135 Ø 110 6 3 x 230 428 7035 7.5 3 x 400 520 7036 9 3 x 400 615 7037 12 3 x 400 725 7038 10

10.2 Heat exchanger for DHW recirculation It is designed to preheat the circuit of DHW recirculation, enabling to cover the heat loss of the recirculation circuit from the solar system directly. This heat exchanger can be installed in place of the top plug of the accumulation tank. It has a G 1 connection thread and is 710 mm long. Inlet to and outlet from the heat exchanger are done through threaded fittings with G 1/2 outer thread. Its plug incorporates a manual air discharge valve for the accumulation tank. hot water cold water recirculation 3c.KK An example how to connect DHW recirculation via a special heat exchanger installed into a HSK. Before installing recirculation, it is advisable to consider if it pays off. There are two aspects, mutually contradicting. Faster supply of hot water to an outlet point and always hot water of a comfortable temperature, for the price of increased energy consumption (power for a recirculation pump and heat losses in piping). On the other hand, thanks to a faster supply of hot water, losses caused by drawing cold water from the hot-water tap are eliminated and water savings are reached. The connecting pipes of the recirculation heat exchanger and recirculation circuit inside a building shall be well insulated to prevent heat loss. In case of a poor insulation or a more distant outlet point, the output of the heat exchanger might be insufficient due to its limited size. 11

10.3 Watersoft N electromagnetic water treatment device The device for electromagnetic water treatment, Watersoft N, uses no chemicals. It softens water, prevents scale formation and dissolves existing sediments. It is particularly suitable for use with devices with thermally stresses spots like heat exchangers and storage water heaters. Among its advantages is a quick and easy installation, no need for plumber s intervention and min. operation costs (consumption of el. energy 2W). Model WATERSOFT N Operation indication green LED Version wall mount Power supply 230V / 50Hz Power input max. 2W El. protection IP 65 Dimensions 70 x 50 x 34 (mm) Max. pipe diam. 1 ½ Max. water flow 4m 3 /h 10.4 Additives for heating systems MR-501/F Protective liquid made of organic compounds, intended for use in heating and cooling systems, solar collectors and heat pumps. It prevents corrosion of metals (iron, copper, aluminum etc.) and their alloys by creating a film on the surface that is in touch with the heating liquid. It can be mixed with antifreeze fluids. Recommended use: after cleaning the system with M 501. MR-501/96P Liquid agent of balanced efficiency for underfloor heating, solar panels and plastic piping. It creates a protective film and prevents growth of algae and gas formation. The system is also protected against calcareous sediments. This wellbalanced mixture of corrosion inhibitors and protective film creating compounds ensures a max. protection of underfloor heating and solar panel circuits. MR-501/R (1kg) Concentrated alkaline anti-corrosion liquid removing scale and calcareous sediments from heating systems. It dissolves scale and rust and makes it possible to remove them by flushing the system. 2 liters of MR-501/R shall be added to every 80-100 l of heating water and let to act for 2-3 weeks depending on the degree of sedimentation. Then the heating system shall be drained and flushed. When filling new water, it should be treated by adding the protective liquid MR 501/F. 12

13

WARRANTY CERTIFICATE for HSK Accumulation Tank Model:... Serial number:... WARRANTY CONDITIONS 1. The warranty period is 60 months from the date of purchase. 2. When claiming warranty, this Warranty Certificate must be submitted together with the purchase receipt. 3. The warranty is valid only when the technical conditions set by this Manual are maintained and installation is done by an authorized person (confirmed in the Warranty Certificate). 4. The claimed defect must not be caused by tampering, improper installation and operation, using the product for other purposes than intended, placing the product in improper environment, or by a natural disaster. 5. Claims shall be settled by your dealer at the address shown below. Date of purchase:... Stamp print, signature of the salesman and address of the shop: Date of a professional installation by plumber:... Stamp print, signature and address of the authorized person: 08/200 8 REGULUS spol. s r.o. Do Koutů 1897/3 CZ-143 00 Praha 4 http://www.regulus.eu E-mail: sales@regulus.cz