UPS + AVR Uninterruptible Power System. User s Manual. PowerStar Series (1200/1700/2200) 100% 80% 60% 40% 20% NORMAL BACK UP LOW BATT.

Similar documents
User s Manual AURORA 1.2K/2.2K

How To Use A Power Supply Unit (Upu)

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Powerware 5110 UPS User s manual

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

Line Interactive UPS

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

350, 500, 650 and 1000 MODELS

10000HXL31/15000HXL31/20000HXL31

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

How To Use A Power Supply Unit (Upland)

Online UPS. PowerWalker VFI 1000R/1U

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

HP UPS R1500 Generation 3

User s Manual Before using the inverter, you need to read and save the safety instructions.

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

UPS VA User s Manual

Back-UPS Pro 1300/1500 Installation and Operation

User Manual 1K/2K/3K Online UPS

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

EKOS Cart. Instructions for Use

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

User Manual for CH-PFC76810

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

USER MANUAL Online UPS 1K/2K/3K Rack

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

Installation and Operation Back-UPS 1250, 1300, 1500

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

BroadBand PowerShield. User Manual

USER MANUAL Online UPS 1K/2K/3K

USER MANUAL Online UPS 6K/10K RACK

UPS-2200R-HH/UPS-2200R-HHIP

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

750VA/1000VA/1500VA 100/120/230VAC 2U

Uninterruptible Power Supply

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

2013 VTech Printed in China US

=============================== WARNING

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

AC-115 Compact Networked Single Door Controller. Installation and User Manual

3000W Power Inverter

HM-W536 Install Guide

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

Delta UPS - Amplon Family. User Manual. E Series, Single Phase 1/2/3 kva. The power behind competitiveness ON OFF ON LINE

Home Solar Kit Owner s Manual. Model: HS

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

Instruction manual for Firstline FCS12000CH

Single Day Alarm Clock with. Bluetooth and USB Play-through

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

NeTYS PR VA

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

400 Amp Rechargeable Jump Start System RAC-HP082

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

TMS TANK MANAGEMENT SYSTEM

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Digital Keypad Use s Manual

Power your CPAP machine no matter where your world takes you!

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

PowerGem Pro Uninterruptible Power Supply

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000/1500 VA. 100/120/230 Vac. Rack Mount 2U

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

700 VA VA UPS. User s and Installation Manual. EMC Statements. FCC Part 15 ICES-003

Model #: SMART2200CRMXL

FlexFlash Instruction Manual Models SB FLXFLSH400W, SB FLXFLSH200W, SB FLXFLSHE400W, SB FLXFLSHE200W

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

AC Power For Business-Critical Continuity. Liebert PSI. User Manual 750/1000/1500/2200/3000, 230VAC

Important Safety Instructions

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

FIREDEX Conventional Fire Panels

PSC-A5 Solar Charge Controller Manual

VA

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

3.5 Dual Bay USB 3.0 RAID HDD Enclosure

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)

Manual for Fire Suppression & Methane Detection System

SPL 2-00/-01 OPERATION INSTRUCTIONS

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Internet Office UPS System Standby UPS for PCs, workstations and more

Battery Power Inverters

3 WATT LED SPOTLIGHT Model No. SLM

Transcription:

UPS + AVR Uninterruptible Power System THE BRITISH POWER CONVERSION COMPANY User s Manual PowerStar Series (200/700/2200) Replace Battery Alarm Off Charging Buck? Boost? SPECIAL STATUS 00% 80% 60% 0% 20% BATTERY LEVEL NORMAL BACK UP LOW BATT. OVER LOAD

TABLE OF CONTENTS FRONT PANEL ----------------------------------------- Page 2 REAR PANEL ------------------------------------------- Page 3. INTRODUCTION -------------------------------- Page. Overview.2 Battery replacement warning.3 Smart AVR MEMO 2. MAIN FEATURES ------------------------------- Page 3. CAUTION ------------------------------------------ Page 5. INSTALLATION AND OPERATION --------- Page 5-6. Installation.2 Operation.3 Audible alarm 5. INDICATION AND CONTROL ------------- Page 7-8 5. Battery level LEDs 5.2 Special status LEDs 5.3 Auto self-test function 5. Status LED and Alarm indication 5.5 Reset the UPS 6. COMMUNICATION INTERFACE ----------- Page 9 7. TROUBLE SHOOTING ------------------------ Page 0 8. SPECIFICATIONS ------------------------------ Page 9. IMPORTANT SAFETY INSTRUCTIONS -- Page 2

MEMO Front Panel Replace Battery Alarm Off Charging Buck? Boost? SPECIAL STATUS 00% 80% 60% 0% 20% BATTERY LEVEL 3 2 NORMAL BACK UP LOW BATT. OVER LOAD 2 3 LEDs of battery voltage level. LEDs of UPS special status. LED of operation status. Control button. 3 2

Rear Panel 9. IMPORTANT SAFETY INSTRUCTIONS 3? When replacing the batteries, use the same number and the same type of batteries.? Do not dispose of batteries in a fire; the battery may explode. 2 NEMA Type? Do not open or mutilate the battery or batteries, released electrolyte is harmful to the skin and eyes.? A battery can present a risk of electric shock and high short circuit current. The following precaution should be observed when working on batteries. IEC Type * Remove watches, rings or other metal objects. * Use tools with insulated handles.? To prevent an overbalance of this unit, with the installation the additional stabilizer are to mount at the bottom side. 2 3 Fuse. Inlet of city power. RS-232 port (DB-9). Outlet(s) (NEMA/IEC).? This unit should be installed from service personnel.? The equipment can be operated by any individuals without any previous experience.? The socket-outlet shall be installed near the equipment and easily accessible.? With the installation of this equipment it should be prevented, that the sum of the leakage current of the UPS an the connected consumer does not exceed 3.5mA.? Attention, hazardous through electric shock. Also with disconnection of this unit from the main, hazardous voltage still may be accessible through supply from battery.? The battery supply should be therefore disconnected in the plus and minus pole through the from the outer enclosure accessible battery fuses when maintenance or service work inside the UPS is considered.? The lead acid battery may cause chemical hazard.? The battery presents a risk of electric shock and energy hazard.? Batteries will be disposed by the manufacturer or importer. Customers need to send them back with no charge for disposal.? Electrical hazard, the discharge time is about 5 min. 3 2

8. SPECIFICATIONS: CAPACITY INPUT OUTPUT Voltage Frequency 200VA 700VA 2200VA 700W 050W 00W Selectable 00/0/5/20V ø or 200/220/230/20V ø 50Hz/60Hz Auto detect Current (0V/220V) 2A / 6A 6A / 8A 2A / 0A Voltage 00/0/5/20V ø or 200/220/230/20V ø ±6% for Back-up Mode Frequency Wave Form < ±0% for AVR 50Hz or 60Hz ± 0.Hz (Selectable under DC start) Simulated Pseudo Sine Wave Current (0V/220V) A / 5.5A 5.5A / 7.8A 20A / 9.8A TRANSFER TIME BATTERY ms typical. Lead-Acid, maintenance free Voltage/Capacity 2V 7Ah X 2pcs 2V 7Ah X 3pcs 2V 7Ah X pcs Level Ind. YES YES YES Recharge Time 90% within hrs LED/ALARM INDICATION Normal/In charge GRN LED, No Beep. Back up / Abnormal Input Voltage ORG LED Flashing, 2 Beeps / 8 sec. Abnormal Input Frequency (Back up) ORG LED Rapid Flashing, 2 Beeps / 8 sec. Green mode auto off ORG LED flashing, Beep / sec. (Auto off after 2 sec.) Low Battery ORG LED Flashing, Beeps / sec. Battery Replacement RED LED Flashing, 8 Beeps/ sec. Over Load/Fault RED LED Flashing, Continuous Beep. INDICATION OF SPECIAL STATUS Replace Battery / Alarm Off / Charging / Buck / Boost DC START / ALARM RESET YES YES YES BATTERY LOAD INDICATION YES YES YES ENVIRONMENT TEMP. 0-37? ENVIRONMENT HUMIDITY DIMENSIONS (L x H x W) (cm) 30-95% Non-Condensing 38 x 20 x 8 x 20 x 8 5 x 20 x 8 SHIPPING DIM. (L x H x W) (cm) WEIGHT (N.W. / G.W.) (kgs). INTRODUCTION 8 x 33 x 30 5 x 33 x 30 6 x 33 x 30 5/6 2.50/22.50 25/26. Overview: The PowerStar series UPS is an advanced high performance stand by Uninterruptible Power System (UPS) designed to protect your computer from utility line failure. In the event of utility failure (blackout), the UPS will rapidly transfer loads to an alternative power source, which derives power from battery set inside the UPS. The UPS provides two charging mode, quick charging and trickle charging, to maintain the batteries in the best condition. Battery status indication, including capacity, low battery condition, charging condition, and replace battery condition, are shown on the front panel..2 Battery Replacement warning The self-test function (real-time detection) will inform you with an alarm when the batteries are weak and require replacement..3 Smart-AVR The UPS automatically corrects output voltage within the normal range, both in low utility voltage ( Boost LED lights up) and high utility voltage ( Buck LED lights up) conditions. 2. MAIN FEATURES:? Microprocessor based design.? Advanced indication for special operation status.? Green mode function.? Auto select input frequency 50Hz/60Hz.? Self test function.? Battery replacement indication.? Extra wide-range AVR function.? Standard RS-232 port for monitoring function.? Double protections for over load & short circuit.

3. CAUTION : * The UPS is designed to power computer loads and the associated peripheral devices, such as monitors, modems, external H-Disk drivers, etc. To ensure the performance of the UPS, Do Not load the UPS with laser printer, motor, or any type of inductive load. * Connecting the UPS to a two-pole, three-wire grounding mains receptacle. Connection with any other type of receptacle may result in a shock hazard and may violate local electrical codes. * Do not allow water or any foreign object to get inside the UPS. And do not put objects containing liquid on or near the unit. * Keep UPS away from fire or heating sources. * The UPS is shipped from the factory with fully charged internal batteries; however, the batteries may lose some energy during delivery and storage. To ensure that the UPS will provide the expected run-time during a blackout, the UPS must be left in charging for at least 5 hours before your first use. The batteries would be recharged automatically by the UPS when the UPS is connected with city power.. INSTALLATION, OPERAT ION & AUDIBLE ALARM : 7. TROUBLE SHOOTING Problem Possible Cause Action to Take UPS no reaction while AC is connected Power output is normal, UPS emits continuous beep, and status LED shows RED. UPS does not provide expected run time Button on front panel doesn t work. Line cord plug is loose 2. Fuse on rear panel blown (Inside the drawer of inlet) 3. Dead wall socket UPS is over loaded. Excessive loads connected at UPS s outlets. 2. Battery is weak and cannot provide enough capacity.. The CPU inside UPS is not running correctly. 2. Button damaged.. Check the line cord plug 2. Replace fuse 3. Check wall socket with a table lamp. Turn off UPS and unplug excessive loads from UPS. Do not operate the UPS, and leave the UPS plugged in for 0 hours. Then, test it again, if UPS still cannot provide expected run time, battery should be replaced.. Push the button for 6 seconds to reset the UPS. 2.Unplug line cord and all loads from the UPS, and call for service.. Installation * Inspecting the packing carton for damage that may have occurred while in transit. Immediately notify the carrier and place of purchase if any damage is found. Retain the package for future use. * Plugging the power cord to a 3-wire grounding receptacle. If an extension cord must be used between the UPS and the nearest wall outlet, use a 3-wire grounding type rated for at least 20 Amps. Under AC mode, UPS emits urgent beep (8 beeps per sec.) and replaces battery LED comes on. No output when blackout happen. Battery is weak and should be replaced. Dead battery. 2. UPS NG. Replace batteries.. Replace battery. 2. Call for service. * Connecting your equipment to the UPS. To ensure that your computer equipment will be protected during a utility failure, it is important to make sure that the maximum power need of the equipment is not over the rated capacity of the UPS. When blackout happens, LED of operation status will become red and alarm will beep if the load is over the rated value. Meantime, if the overload is severe, the UPS will shut down immediately for protecting UPS itself. 5 0

6. COMMUNICATION INTERFACE: Pin2 Pin Pin5 Pin6 Pin7 Computer RS232 : AC Power Failure : Common GND of Pin2 & Pin5 : UPS Battery Low : Turn off UPS : GND of Pin6 5 3 2 9 8 7 6 The interface with computer is diagramed as above for your reference. Use Pin as the common of Pin2 and Pin5, Pin2 and Pin will become close loop from open when the utility fails, Pin5 and Pin will become close loop from open when the battery level is low. The UPS will shut down itself when the high level from RS-232, sustained for 3 seconds, is applied between Pin6 and Pin7..2 Operation.2. When the power cord is connected with normal city power, UPS will turn on automatically and go through the procedure of self-test (about 3- sec.). If test results are O.K., the green LED will be on..2.2 Pushing the button for 3 seconds, the UPS will turn off the power. But, the red LED will remain blinking when the AC power cord is connected. To turn off the power completely, please pull out the power cord. For turning on the UPS again, please connect back power cord and push the button..2.3 During blackout, push the button for 3 seconds until the buzzer emit beeping, the UPS will turn on and enter into back up mode. To turn off the UPS, please push the button for 3 seconds..3 Audible alarm During a utility failure or fault operation, the UPS emits beep for warning. In back-up mode, the beeping can be silenced by pushing the button. However, the warning of low battery will still sound for urging user to leave computer without any data loss. 9 6

5. INDICATION AND CONTROL 5. Battery level LEDs The battery level LEDs show the voltage level both in back-up mode and in normal mode. When the LED indicates 20% of the capacity in back-up mode, it means that the UPS is going to shut down; for the length of backup time left, it will depend on the load. While when all five LEDs light in normal mode, it means that the battery is fully charged. 5.2 Special status LEDs The Replace Battery LED would be on when the UPS s battery is no longer useful and must be replaced. When the Alarm Off LEDs comes on, the UPS will not emit beep during back-up mode or when battery needs to be replaced. However, the low battery alarm and over load alarm will still sound for urging user to leave computer without any data loss. The Charging LED would be on when the charger is charging the battery. While the battery voltage is low in normal mode, the charger will keep on quick charging, when the battery voltage is high, the charger is keeping on for seconds by every 2 seconds for trickle charging. The Boost LED would be on when the UPS is connecting a low utility voltage. The loads receive normal power. The Buck LED would be on when the UPS is connecting a high utility voltage. The loads receive normal power. 5. Status LED and Alarm Indication:? GRN LED, no alarm ------------------------------------------------ City power normal.? ORG LED flashing, two beeps / 8 sec. ----------------------- Backup mode.? ORG LED flashing, one beep / sec. ----------------------------- No load. (Auto shut down after 2 sec.)? ORG LED flashing, quick beeping, beeps / sec --------- Low battery.? Red LED flashing, continuous beeping ------------------ Over load.? Replace battery LED, urgent beeping, 8 beeps / sec -----Battery Replacement. 5.5 Reset the UPS If any abnormal condition occurs, and the item.2. ~.2.3 can not be executed, please push the button for at least 6 sec. until the buzzer emit continues beeping, then the UPS is reset. Under back-up mode, the UPS will be turned off by reset. While under AC mode, the UPS will go through the procedure of self-test by reset. 5.3 Auto self-test function: In normal mode of UPS, turn on your computer and push the button on the front panel for self-test. The UPS will simulate a power outage and transfer your load to the UPS s battery. If low battery warning sounds during the test, it means that the battery set is weak and requires extended recharge. If replace battery warning sound, it means that the battery set is damaged and requires replacement. 7 8