HEAT TRANSFER BY NATURAL CONVECTION THROUGH V-CORRUGATED PLATES

Similar documents
Experimental Study of Free Convection Heat Transfer From Array Of Vertical Tubes At Different Inclinations

AN EXPERIMENTAL STUDY OF EXERGY IN A CORRUGATED PLATE HEAT EXCHANGER

HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

FREE CONVECTION FROM OPTIMUM SINUSOIDAL SURFACE EXPOSED TO VERTICAL VIBRATIONS

Effect of Aspect Ratio on Laminar Natural Convection in Partially Heated Enclosure

Natural Convection. Buoyancy force

Enhancement of heat transfer of solar air heater roughened with circular transverse RIB

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS

Ravi Kumar Singh*, K. B. Sahu**, Thakur Debasis Mishra***

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Basic Equations, Boundary Conditions and Dimensionless Parameters

FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES

Numerical Investigation of Heat Transfer Characteristics in A Square Duct with Internal RIBS

Theoretical and Experimental Investigation of Heat Transfer Characteristics through a Rectangular Microchannel Heat Sink

Natural convection in a room with two opposite heated vertical walls

EXPERIMENTAL STUDIES ON PRESSURE DROP IN A SINUSOIDAL PLATE HEAT EXCHANGER: EFFECT OF CORRUGATION ANGLE

PRESSURE DROP STUDIES IN WAVY CORRUGATED PLATE HEAT EXCHANGERS

Abaqus/CFD Sample Problems. Abaqus 6.10

EXPERIMENTAL ANALYSIS OF PARTIAL AND FULLY CHARGED THERMAL STRATIFIED HOT WATER STORAGE TANKS

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

An experimental investigation of heat transfer of free convection on triangular fins in order to optimize the arrangement of fins

EXPERIMENTAL ANALYSIS OF HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE WITH DIFFERENT TWIST RATIO OF TWISTED TAPE INSERTS

Experimental Study On Heat Transfer Enhancement In A Circular Tube Fitted With U -Cut And V -Cut Twisted Tape Insert

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

Effect of design parameters on temperature rise of windings of dry type electrical transformer

Natural Convective Heat Transfer from Inclined Narrow Plates

Department of Chemical Engineering, National Institute of Technology, Tiruchirappalli , Tamil Nadu, India

HEAT TRANSFER ENHANCEMENT AND FRICTION FACTOR ANALYSIS IN TUBE USING CONICAL SPRING INSERT

Experimental Investigation on Turbulent Flow Heat Transfer Enhancement in a Horizontal Circular Pipe using internal threads of varying depth

Heat Transfer Enhancement in a Heat Exchanger using Punched and V-cut Twisted Tape Inserts

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.6, pp ,

RESPONSE TIME INDEX OF SPRINKLERS

Adaptation of General Purpose CFD Code for Fusion MHD Applications*

Understanding Mantle Heat Exchangers Used in Solar Water Heaters

Integration of a fin experiment into the undergraduate heat transfer laboratory

Experiment (13): Flow channel

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

Iterative calculation of the heat transfer coefficient

Comparing naturally cooled horizontal baseplate heat sinks with vertical baseplate heat sinks

Thermocline Management of Stratified Tanks for Heat Storage

Keywords: Heat transfer enhancement; staggered arrangement; Triangular Prism, Reynolds Number. 1. Introduction

TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF FORCED CONVECTION FLOW AND HEAT TRANSFER IN A LAMINAR CHANNEL FLOW

Heat Transfer From A Heated Vertical Plate

NUMERICAL INVESTIGATIONS ON HEAT TRANSFER IN FALLING FILMS AROUND TURBULENCE WIRES

Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment

THERMAL STRATIFICATION IN A HOT WATER TANK ESTABLISHED BY HEAT LOSS FROM THE TANK

EFFECT OF USE OF SWIRL FLOW DEVICES TO IMPROVE HEAT TRANSFER RATE IN HEAT EXCHANGERS

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

Heat Transfer Analysis of Cylindrical Perforated Fins in Staggered Arrangement

HEAT TRANSFER IM LECTURE HOURS PER WEEK THERMODYNAMICS - IM _1

Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22

Correlations for Convective Heat Transfer

The Three Heat Transfer Modes in Reflow Soldering

Testing and Performance of the Convex Lens Concentrating Solar Power Panel Prototype

International Journal of Research in Science and Technology

Battery Thermal Management System Design Modeling

Internal cooling augmentation in rectangular channel using two inclined baffles

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Steady Heat Conduction

STUDY OF HEAT TRANSFER ON BROKEN ARC ROUGHNESS ELEMENTS ON THE ABSORBER PLATE FOR SOLAR ENERGY BASED HEATER: A REVIEW

Experimental Evaluation Of The Frost Formation

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

XI / PHYSICS FLUIDS IN MOTION 11/PA

INTEGRATED ROCK BED HEAT EXCHANGER-CUM-STORAGE UNIT FOR RESIDENTIAL-CUM-WATER HEATING. C. CHOUDHURY and H. P. GARGt

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

THE PSEUDO SINGLE ROW RADIATOR DESIGN

Free piston Stirling engine for rural development

The Effect of Mass Flow Rate on the Enhanced Heat Transfer Charactristics in A Corrugated Plate Type Heat Exchanger

Natural Convection in Stratified Hot Water Storage Tanks

ENHANCEMENT OF HEAT TRANSFER USING WIRE COIL INSERTS WITH CHORD RIBS

Understanding Boiling Water Heat Transfer in Metallurgical Operations

Everline Module Application Note: Round LED Module Thermal Management

EXPERMENTATIONAL DATA ANALYSIS OF CHIMNEY OPERATED SOLAR POWER PLANT

Experiment 3 Pipe Friction

What is the most obvious difference between pipe flow and open channel flow????????????? (in terms of flow conditions and energy situation)

NUCLEAR ENERGY RESEARCH INITIATIVE

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

Laminar Flow and Heat Transfer of Herschel-Bulkley Fluids in a Rectangular Duct; Finite-Element Analysis

Effect of Pressure Ratio on Film Cooling of Turbine Aerofoil Using CFD

Exergy Analysis of a Water Heat Storage Tank

A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS

Optimization of electronic devices placement on printed circuit board

1150 hp motor design, electromagnetic and thermal analysis

DSRQ - DSRSQ - DSRSQ-THERM

A Demonstration Plant of a Liquid Desiccant Air Conditioning Unit for Drying Applications

EXPERIMENTAL AND CFD ANALYSIS OF A SOLAR BASED COOKING UNIT

2. CHRONOLOGICAL REVIEW ABOUT THE CONVECTIVE HEAT TRANSFER COEFFICIENT

Review of Heat Transfer Parameters of Serrated Plate Fin Heat Exchanger for Different Materials

An Experimenatl Study on Heat Transfer Behaviors of A Welded - Aluminum Minichannel Heat Exchanger

Differential Relations for Fluid Flow. Acceleration field of a fluid. The differential equation of mass conservation

A COMPUTATIONAL FLUID DYNAMICS STUDY ON THE ACCURACY OF HEAT TRANSFER FROM A HORIZONTAL CYLINDER INTO QUIESCENT WATER

AS COMPETITION PAPER 2008

Fluids and Solids: Fundamentals

Jet Impingement Cooling

Experimental investigation of heat transfer and flow friction in a circular tube fitted with regularly spaced twisted tape elements

du u U 0 U dy y b 0 b

FEDSM Flow Boiling Heat Transfer Enhancement in Subcooled and Saturated Refrigerants in Minichannel Heat Sinks

Transcription:

Heat Transfer by Natural Convection 1 HEAT TRANSFER BY NATURAL CONVECTION THROUGH V-CORRUGATED PLATES Mohammad Ali and M. Hasanuzzaman Department of Mechanical Engineering Bangladesh University of Engineering and Technology Dhaka-00, Bangladesh Abstract: An experimental investigation is performed on natural convection heat transfer through a square enclosure of V- corrugated vertical plates. The objective of this investigation is to study the variation of heat transfer rate through the square enclosure with the variation of both hot and cold plate temperatures. Hot plate temperature is varied by heat input. To vary cold plate temperature two parameters are considered: one is mass flow rate of water used to remove heat from cold plate and the other is the inlet temperature of water. Air is the media to transfer heat from the hot V-corrugated plate to cold V-corrugated plate. The result shows that the increase of mass flow rate increases the heat transfer rate and the decrease of water inlet temperature increases the heat transfer rate. INTRODUCTION Natural convection is an important mode of heat transfer. The existence of natural convection heat transfer between horizontal plates heated from below was first referred by Thomson 1 in 1882 noting the presence of cellular patterns in soapy water whose mean temperature was greater than the ambient. In 1900, Benard 2 published photographs taken with a beam of parallel light that has passed through a layer of paraffin oil whose thickness was small compared with its diameter and which was heated from below. Those photographs clearly indicated the presence of a hexagonal cellular convection pattern. Natural convection is observed because of the motion of the fluid due to density change arising from heating process. The movement of the fluid in natural convection results from the buoyancy forces imposed on the fluid when its density in the proximity of the heat transfer surface is decreased because of thermal expansion of the fluid in a non-uniform temperature distribution. Convection heat transfer is dependent on the movement of the fluid and the shape of the heat transfer surfaces influences the development of the flow of fluid. A significant number of investigations have been carried out on heat transfer across V-corrugated and other configured surfaces. Chinnappa 3 carried out an experimental investigation on natural convection heat transfer from a horizontal lower hot V-corrugated plate to an upper cold flat plate. The author took data for a range of Grashof number from 4 to 6. The author noticed a change in the flow pattern at Grashaf number, Gr=8x 4, which he concluded as a transition point from laminar to turbulent flow. Randall et al. 4 studied local and average heat transfer coefficients for natural convection between a V-corrugated plate (º V-angle) and a parallel flat plate to find the temperature distribution in the enclosed air space. The author recommended a correlation in which the heat flux is % higher than that for parallel flat plate. Elsherbiny et al. 5 investigated free convection heat transfer for air layers bounded by a lower hot V-corrugated plate and upper cold flat plate. A single correlation equation in terms of Nusselt number, Rayleigh number, tilt angle and aspect ratio was developed for the aspect ratio ranging from 1 to 4 and angle of inclination ranging from 0 to degrees. They claimed that the convective heat transfer across air layer bounded by V-corrugated and flat plate was greater than those for parallel flat plates by a maximum of 40%. Beitelmal et al. 6 performed an experimental investigation on the effect of surface roughness of a uniform heated plate on the average heat transfer characteristics of an impinging air jet. Temperature and heat transfer were measured for variation of both Reynolds number and jet exit-to-plate spacing. The average Nusselt number for both cases was plotted versus the Reynolds number and their functional correlation was determined. The results indicated an increase of up to 6.0% of the average Nusselt number due to surface roughness. Zhong et al. 7 carried out a finite difference study to determine the effects of variable properties on the temperature and velocity field and the heat transfer in a differentially heated two-dimensional square enclosure. Nayak et al. 8 considered the problem of free and forced convection in a full-developed laminar steady flow through vertical ducts under the conditions of constant heat flux and uniform peripheral wall temperature. Ozoe et al. 9 performed a set of experiments for laminar convection in silicone oil and in air along a rectangular channel. The aspect ratios (width/height) of the cross-section of the channel were 1, 2, 3, 4.2, 8.4 and 15.5 and the Rayleigh number was varied from 3x 3 to 5. Sofir Uddin et al. investigated the natural convection heat transfer and fluid behavior for vertical sinusoidal walls. The result showed that for corrugation frequency=3 with different Grashof numbers, the heat flux became lower than that of straight wall and with corresponding Grashof number for corrugation frequency=1, the total heat flux became higher than that for the straight one. Dropkin et al. 11 performed an experimental investigation on natural convection heat transfer in liquid confined by two parallel plates and inclined at various angle with respect to horizontal direction. The range of Rayleigh number covered in the experiment was 5x 4 to 7x 8 and Prandtl number was varied from 0.02 to 115. Experiments were carried in rectangular and circular containers having copper plates and insulating walls. The liquid used was water, silicon oil and mercury. De Graaf et al. 12 studied the heat transfer rate for air layers of inclination angle ranging from 0 to 90 degree. The range of Rayleigh number covered was approximately 3 to 5. However, from the review of published results it can be pointed out that there is no useful data on natural convection heat transfer with V- corrugated vertical walls, which forms the basis for the motivation of present study.

Heat Transfer by Natural Convection 2 EXPERIMENTAL SETUP The experimental setup of the investigation is a square enclosure with two V-corrugated vertical plates. One is a hot plate heated by electric heater and the other is a cold plate cooled by water reserved in a tank. The experimental setup consists of the following assembly: (a) The hot and cold plates assembly (b) The heater assembly (c) The thermocouple assembly (d) The insulator assembly The hot and cold plate assembly Hot plate as shown in Fig.1 is made of corrugated mild steel sheet of height 42 cm, width 42 cm and thickness 2 mm. The corrugation amplitude is fixed at 5 percent of the enclosure height, where the amplitude is defined as a half of the horizontal distance, measured from the left extremity of the left wall to its right extremity and therefore, the amplitude is 2.1 cm. Folding of a plain sheet with angle makes this corrugation. The cold plate is similar to the hot plate and is used to gain heat from hot plate. The assembled configuration formed by hot and cold plates are shown in Fig. 2. The thermocouple assembly There are 18 thermocouple points to measure the temperature of the surfaces of two V-corrugated parallel vertical plates. Nine thermocouple points at different places are used in hot plate as shown in Fig. 3 and the other nine thermocouple points are used in cold plate as shown in Fig. 4. The thermocouples are located at different points so that it can cover the critical positions and can conform uniform heating of plates. The insulation assembly The insulation assembly consists of asbestos cloth, asbestos tape, glass wool and white tape. The whole body of the setup is covered with asbestos cloth. The heater assembly There are two layers of asbestos on the plate to be heated. Nicrome wire of specification 26 is used for the heater. The wire is placed in between the layers of asbestos. The wire makes a loop on the plate in a rectangular manner as shown in Fig. 5 and tape is used to hold the wire on the asbestos. Asbestos cloth can sustain 120º C. So, the temperature of heater is kept within this range. Mathematical Modeling In this experiment, the V-corrugated plate is heated by electric heater as stated earlier. The equation of the input power can be written as P = V I cosθ where, P is input power in watt, V is input voltage in volt and I is input current in ampere. The heat transfer from hot V-Corrugated plate to cold V-Corrugated plate by natural convection can be written as Q = A h ( T T ) hotplate hotplate coldplate where, A is area of hot plate, m 2 and h is convection heat transfer coefficient, W/ m 2.K. The equation of heat gained by water can be written as Q water = m Cp dt Where, Cp is specific heat at constant pressure, T is temperature in ºC, dt is outlet water temp inlet water temp in ºC and m is mass flow rate of water in gm/s. RESULTS AND DISCUSSION In this experiment natural convection heat transfer through V-corrugated vertical plates has been investigated. In this investigation, water is used as coolant and air is present in the rectangular box between the two V- corrugated vertical plates. The rectangular enclosure has adiabatic surroundings. Therefore, it is expected that the heat transfer will occur only through air confined by enclosure. Trough Hot plate Cold plate Peak Fig. 1: Hot and cold plate Assembly Fig.2: Assembled configuration of V-corrugated plates Thermocouple points Fig.3 in hot plate. Fig.4 in cold plate.

Heat Transfer by Natural Convection 3 Water is flowed over the cold plate. During water flow, the trough of the corrugation produces low velocity of flowing water, whereas the peak of the corrugation produces high velocity of flowing water. Consequently thick boundary layer forms at the trough of corrugation. Therefore, temperature at the trough of the plate is higher than that at the peak of the corrugation. For this reason, little variation of temperature is found among different thermocouple points. Fig. 5 Nicrome wire loop of heater Temperature distribution on hot plate In this investigation, Figs. 6 and 7 show the temperature distribution on the hot plate for different heat inputs to the hot side plate. From these figures, we see that temperature of the plate is almost same at all thermocouple points. Small variation of temperature in several thermocouple points can be observed. Between the plate and heater, asbestos is used. As the plate is corrugated, contact between asbestos and plate surface might be loose or tight. Intimate contact of the peak of the corrugated plate with asbestos can be obtained but the fitting of the trough of the corrugated plate with asbestos might loose. Along the trough there is a possibility to stay an air gap between the surface of the plate and asbestos. Therefore, the temperature of the peak of the corrugated plate is greater than that of the trough of the plate. However, due to wave of V-corrugation, small variation of temperature in a few points is observed. Temperature distribution on cold plate Figures 8 and 9 show the temperature distribution in the cold plate for different input power. Though the temperature at all points of the plate should be same, small variation can be observed at different thermocouple points. Effect of different variables In this study the heat transfer through V-corrugated vertical walls is investigated for the variation of (i) Mass flow rate of cooling water (ii) Input heat energy, and (iii) Inlet water temperature (i) Effect of mass flow rate of cooling water Figure (input power watt) and Fig. 11 (input power 1 watt) show the change of heat transfer rate with respect to mass flow rate of cooling water. Both of the figures show that if mass flow rate of water increases, heat transfer rate increases. This is quite natural because for increasing flow rate, the temperature difference between water and confined wall is higher and eventually heat transfer increases. However for low input power as shown in Fig. the slope of the curve is higher for low mass flow rate of water and for high mass flow rate of water the slope of the curve is lower. On the other hand, for high input power as shown in Fig. 11 the slope of the curve is constant which means that the increment of heat transfer is same for different mass flow rates of cooling water used in this investigation. It can be predicted that if mass flow rate of water is further increased for high input power (1 watt), the trend of heat transfer increment might change as can be seen in Fig.. At 80 minutes At 0 minutes At 120 minutes At 140 minutes Temperature (º 75 65 Fig. 6 Temperature distribution in hot V-corrugated plate (Input power watt) At 80 minutes At 0 minutes At 120 minutes At 140 minutes Temperature (º C) 0 95 90 85 Fig. 7 Temperature distribution in hot V-corrugated plate (Input power 1 watt)

Heat Transfer by Natural Convection 4 At 80 minutes At 0 minutes At 120 minutes At 140 minutes Temperature 55 0 2 4 6 8 Fig. 8 Temperature distribution in cold V-corrugated plate (Input power watt) At 80 minutes At 0 minutes At 120 minutes At 140 minutes 75 Temperature (º C) 65 Fig. 9 Temperature distribution in cold V-corrugated plate (Input power 1 watt) (ii) Effect of input energy Figures and 11 show the change of heat transfer rate with respect to input power. If input power increases, heat transfer rate also increases caused by the higher temperature difference. By the slope of the curve it can be understood that for low mass flow rate of cooling water, the increment of heat transfer is higher for low input power but for high mass flow rate of water the increment of heat transfer decreases which is caused by the short residence time of water in the chamber. By comparing the slopes of the curves in Figs. and 11, it can be observed that for higher input energy the slope of curve is low for low flow rate of cooling water and vice-versa. This trend is caused by insufficient mass flow rate of cooling water for high input power. (iii) Effect of inlet water temperature Heat transfer rate depends on the inlet water temperature. Figure shows that for input power of watt, heat transfer rate increases with decreasing of water inlet temperature. For a constant mass flow rate of water, heat transfer rate is greater at inlet water temperature 17.3 C than that at inlet water temperature 27.2 C which is caused by higher temperature difference of cooling water and cold wall. The curve in Fig. 11 also shows same trend on heat transfer. From the above information, we can see that the increasing of both input power and mass flow rate of cooling water increases heat transfer rate. Heat transfer rate increases with decreasing of inlet cooling water temperature. Inlet w ater temp 27.2 C Inlet w ater temp 17.3 C Heat transfer rate (watt) 40 30 20 1.05 1.1 1.15 1.2 1.25 Mass flow rate of cooling w ater ( gm/s ) Fig. Variation of heat transfer rate with mass flow rate of water (Input power watt)

Heat Transfer by Natural Convection 5 Heat transfer rate (watt) 40 30 Inlet water temp 26.3 C Inlet water temp 16.8 C 1.05 1.1 1.15 1.2 1.25 Mass flow rate of cooling w ater (gm/s) Fig. 11 Variation of heat transfer rate with mass flow rate of water (Input power 1 watt) CONCLUSION Natural convection heat transfer through an enclosure with V-corrugated vertical walls has been analyzed and discussed. Heat is transferred from hot plate to cold plate through air by natural convection and from cold plate heat is removed by cooling water. Though the temperature should be uniform at all points of hot and cold plates, slightly higher temperature can be observed at the peaks. It is found that heat transfer rate increases with the decrease of inlet water temperature. Heat transfer rate increases with the increase of input power and mass flow rate of water. For low input power, the increment of heat transfer is high for low mass flow rate of water but high mass flow rate of cooling water causes low increment of heat flux. On the other hand, for high input power constant increment of heat transfer can be observed with the increase of mass flow rate of cooling water. REFERENCES 1. Thomson, J.J., Proc. Glasgow Phil. Soc., Vol.,13,1882, pp. 464. 2. Benard, H., Rev. Gen. Sci. Pures Appl., Vol.11, 1900, pp.1261-1271. 3. Chinnappa, J.C.V., Free Convection in Air between a V-Corrugated Plate and Flat Plate, Int. J. Heat and Mass Transfer, Vol.13, 19, pp.117-123. 4. Randall, R.K., Interferometer Investigation of Convection in Salt-Flat Plate and V- Corrugated Solar Collectors, J. Heat Transfer, Trans ASME, Vol. 1, 1979, pp.120-125. 5. Elsherbiny, S.M., Holland, K.G.T., and Daithby, G.D., Free Convection across Inclined Air Layers with One Surface V-Corrugated, in Heat Transfer Solar Energy Systems, Howell, J.R. and Min, T., (Eds) ASME, New York, 1977. 6. Beitelmal, A. H., Saad, M. A. and Patel, C. D., Effects of Surface Roughness on the Average Heat Transfer of an Impinging Air Jet, Int. Communications in Heat and Mass Transfer, Vol. 27, No. 1, January 2000, pp. 1-12. 7. Zhong, Z.Y., Young, K.T., and Lioyad, J.R., Variable Property Effects in Laminar Natural Convection in A Square Enclosure, J. Heat Transfer, Vol.7, 1985, pp.133-146. 8. Nayak, A.L., and Cheny, P., Finite Elements Analysis of Laminar Convection Heat Transfer in Vertical Ducts with Arbitrary Cross Section, Int. J. Heat and Mass Transfer Vol. 18, 1975, pp.67-71. 9. Ozoe, H., Sayma, H. and Churchill, S.W., Natural Convection in an Inclined Rectangular Channel at Various Aspect Ratios and Angles: Experimental Measurements. Int. J. Heat and Mass Transfer, Vol. 18, 1975, pp. 1425-1431.. Sofir Uddin, M., Al-Azad, S. and Roy, B. D., Natural Convection Heat Transfer and Fluid Flow in A Square Enclosure with Corrugated Vertical Walls, B. Sc., Engg, Thesis, 1988, BUET. 11. Dropkin, D., and Somercales, E., Heat Transfer by Natural Convection in Liquids Confined by Two Parallel Plates Which Are Inclined at Various Angles with Respect to Horizontal, J. Heat Transfer Series C, Vol. 87, 1965, pp-84 12. De Graaf, J. G. A., and Vender Held, F. E. M., The Relation between the Heat Transfer and Convection Phenomena in Enclosed Plain Air Layers. Appl. Sci. Res. A. Vol. 3, 1953, pp 393-409.