The premium intraoral X-ray unit

Similar documents
Digital Dental X-ray. Midmark Animal Health Products

ENGLISH. Planmeca ProMax 3D Mid

ENGLISH. Planmeca ProMax 3D concept

X-Mind. Instinct for perfection

ProOne Digital X-ray Imaging Hardware Diagrams and System Requirements

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

RVG Full range imaging for diagnostic confidence ROBUST DESIGN SUPERIOR ERGONOMICS NEW IMAGE PROCESSING TOOLS ENHANCED WORKFLOW

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

3D Viewer. user's manual _2

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

DENTAL Cone beam 3D X-RAY SYSTEM with

user's manual _19

RVG Innovation set free.

Systematic X-ray diagnostics as flexible and individual as your dental practice.

Systematic X-ray diagnostics as flexible and individual as your dental practice. XIOS PLUS the intraoral sensor system

Imaging made easy. Digital intraoral. Imaging Plate System SMALL SMART FAST

DBSWIN the digital image centre for the surgery

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

OP300 Pre- Installation Document

Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral

The professional for your diagnostics.

1. Customer Contact Information. Scanora 3Dx Site Survey and Pre-Installation Guide

The wait is over CS D. 3D imaging is now available for everyone

VistaScan Perio Plus Image plate scanner more time for patient care

Digital panoramic X-ray for practical diagnostics

The Convenient and Compact CR System for Veterinary Practices

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

EVA. Digital X-Ray System. Exceptional Image Quality Ideal For Any Practice Full Integration Best Supported Sensor Great Value

microscope OP-Dent-5

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

The convenient and compact CR system for veterinary practices

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

icr3600 icr3600m VertX idr Film Digitizers Clarity PACS Innovative Medical Imaging

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Rugged and open to your applications

C4 + Compact design newly defined.

WARNING: We recommend that you consult the Safety, Regulatory and Technical Specification User Guide before using the CS 2200.

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

Cutting Edge Digital Radiography Technology in Daily NDT Use

reflecta Super 8 Scanner

Bitewing Radiography B.E. DIXON. B.D.S., M.Sc., D.P.D.S.

SUMMARY OF CURRENT UK LEGISLATION AND GUIDELINES

TrueAlarm Fire Alarm Systems

VISION DX 600 Series

Installation Guide v1.11 and Higher

MEDICAL IMAGING. 90/30 Remote Controlled RF System

DryView CHROMA Imaging System

VERSATILE AND EASY-TO-USE 3D LASER SCANNERS > >

Be sure to connect the USB cable from TonePort into your computer s USB port, and then proceed with the following steps

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Planmeca Romexis. installation manual EN _20

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Sage Grant Management System Requirements

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

Radiation safety in dental radiography

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

GE Inspection Technologies. Rhythm Total X-ray Inspection Software

Radiation safety in dental radiography

Waveguide Access Point WGA631. Product Guide

Autodesk Inventor on the Macintosh

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

MediaMed Software User Guide

AXIS 262+ Network Video Recorder

TABKAM X1 Tablet camera system evolution of video microscope systems

Item Minimum Required Recommended Notes

Dear Ms. Lucas: This letter corrects our substantially equivalent letter of February 18, 2016.

AN INNOVATIVE & CUTTING-EDGE DIGITAL RADIOGRAPHY SYSTEM

Put Your Panoramic Imaging on Steroids While Reducing the Patient s Dose!

500/600/1000. User Manual June 2011 Rev v061311

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

VERSATILE AND EASY-TO-USE 3D LASER SCANNERS > >

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

Award Winning Digital X-Ray Sensors & Practice Management Software

FOTOSTATION. The best media file organizer. It s organized

Artikel-Detailinformationen

Recording. Smart recording (depending on the camera models)

Dental Radiography Core Subject. Digital Radiography

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

Network device management solution.

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

22 (21.5 viewable) Smart Display, Full HD, Rockchip Quad-Core, Optical touch, Android KitKat. VSD224

DR Retrofit Kit 1417 WL Configuration Integrated PACS

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

CS Solutions. Introducing the CS Solutions portfolio for streamlined CAD/CAM restorations

Network device management solution

Hardware and Software Requirements for Installing California.pro

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

MS6000 Microform Scanner

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

JB-70 Dental X-Ray System

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the

Veraviewepocs 3D R100 & F40

Minimum Hardware Specifications Upgrades

Merge CADstream. For IT Professionals. Merge CADstream,

DIGICLIENT 8.0 Remote Agent Software

Software Installation and Creating a New Company

Continuous Workflow. Business Document Scanning. Engineered for. Fast, accurate and reliable digital conversion for batch scanning and archiving

Transcription:

ENGLISH

The premium intraoral X-ray unit The recognised Planmeca Intra X-ray unit design concept makes intraoral imaging easier and more trustworthy than ever before. Incorporating innovative and open-minded technical solutions, Planmeca Intra is not only easy to use, but it also delivers radiographs with outstanding clinical utility. The sophisticated concept, functional design, and superior image quality have convinced dental professionals all over the world. 2 3

50 kv 60 kv 70 kv Variable kv assures the best image contrast The high-quality construction and the advanced technological solutions make the Planmeca Intra X-ray unit the premium choice for intraoral radiography. The freely selectable exposure parameters (kv, ma, and exposure time) maximise the diagnostic value of intraoral radiography, and the pre-programmed quick settings make the operation fast and easy. The acknowledged Planmeca design features rounded corners and smooth lines, ensuring longevity, stability, and good hygiene. Planmeca Intra has a very high-frequency operated constant potential X-ray generator, which provides significant advantages such as: reduced radiation dose by up to 25% when compared to conventional AC generators extremely good and uniform image contrast absolute reproducibility of images improved reliability and prolonged life span of the X-ray tube the X-ray unit output is not affected by line voltage fluctuations. With eight user selectable kv settings 50, 52, 55, 57, 60, 63, 66, and 70 kv Planmeca Intra provides tremendous freedom of choice that assures the best image contrast for any diagnostic need or anatomical condition. 50 kv: Low kv settings result in high-contrast images that are extremely useful for endodontics, apex, and bone structure diagnostics. 60 kv: Medium kv settings provide a wide greyscale for general diagnostics where a wide range of clinical information is required. 70 kv: High kv settings produce images with a long greyscale spectrum, which is useful in caries detection and periodontal diagnostics. 4 5

Ergonomic design for easy imaging The unique non-symmetric design of the X-ray tube head makes aiming exceptionally easy and precise. The smooth top cover of the tube head extends seamlessly to the cone, a clever design making X-ray beam alignment faster and more accurate. The intelligent tube head and X-ray arm design facilitates positioning for an occlusal plane image. The Planmeca Intra X-ray unit adapts to short cone (20 cm SSD) as well as to long cone (30 cm SSD) imaging techniques. Furthermore, an additional rectangular collimator can be adapted to the long cone for maximal radiation hygiene. The extremely steady X-ray unit arm provides smooth and precise movement, providing accurate and drift-free positioning of the lightweight tube head. With the unit s versatile installation options, the reach is well sufficient for different practice designs. Planmeca's innovative engineering ensures that the X-ray unit meets any demand within digital intraoral radiography. A simple selection of the image receptor automatically adapts the pre-programmed settings to film, imaging plate, or digital sensors. Ultimate user-friendliness is achieved when the unit is used together with the Planmeca ProSensor digital sensor system: The user can easily position the sensor into patient s mouth with the TrollByte Plus sensor holder. The Planmeca ProSensor interconnection cable is routed inside the X-ray unit arm, which results in a clear and clean working area with no interfering cables. The imaging parameters (kv, ma, exposure time) are transferred to the imaging software to be recorded with the patient's images. 6 7

Automatic image settings and controls The imaging parameters are selected from the intuitive control panel. The unit is pre-programmed with 66 quick settings for different exposure value combinations. Imaging parameters are automatically retrieved according to the selected exposure region and the diagnostic need: periapical imaging of the incisors, premolars/canines, and molars, separately for upper and lower jaw upper and lower occlusal plane imaging bitewing imaging endodontic imaging. The control panel displays the selected values. They can be manually adjusted, if needed. The operator can also store the altered setting in the quick setting memory. There are distinct, optimally adjusted settings for adults and children. The selection of the imaging mode allows a rapid transformation of all pre-programmed settings when changing to a new image receptor type. There are predefined imaging modes for film, imaging plate, and digital sensor. This allows very fast and trouble-free transition to new imaging technologies without any reprogramming of the quick settings. Planmeca Intra features a smart control for maintaining the constant darkness of the radiograph whenever imaging conditions change. The unit has eleven density steps that adjust all quick settings if, for example, the user decides to change the film type or wants to use the short cone technique instead of the long cone technique. The self-diagnostic control system monitors all unit functions and displays error messages in case of abnormal operation. The control system assists in the correct use of the unit and speeds up technical service. After each exposure, the automatic duty cycle control displays an overheat countdown ensuring reliable long-term operation of the X-ray tube. The unit is delivered with a hand held control panel or optionally a wall-mounted remote exposure station. 8 9

Integrated digital sensor The Planmeca ProSensor digital radiography system is a major contribution to increased workflow. The dental team can focus on the patient, since the imaging procedure includes a minimum amount of steps. Planmeca ProSensor is designed, first and foremost, with durability in mind. The sensor cable is a result of careful design, technology and testing. Hermetically sealed, the sensor can be fully immersed in disinfectant for effective infection control and prevention. The intelligent housing design with rounded edges and extensive active imaging area maximises both patient comfort and imaging performance. Placing the sensor and the control box conveniently at the Planmeca Intra X-ray unit allows a clear and well-organised working environment without interfering cables. After the exposure, the image is displayed on the screen within seconds. Instantaneous viewing dramatically shortens the time needed for an intraoral X-ray examination, when compared to imaging plates or conventional film. 10 11

kv MODE BW READY PRET ma SELECT s 236 (9 ) Installation options 1063 (42 ) 745 (29 ) Dimensions 460 (18 ) 575 (23 ) 1120 (44 ) 1150 (46 ) 575 (23 ) Standard wall mount Remote control panel Fixed control panel with double exposure button Planmeca dental unit mount control panel generator box telephone cable telephone cable extension cable 320 Single stud mount Ceiling mounting (with Planmeca Delight operating light) Floor mounting column Mobile stand 450 75.5 (3 ) 385 (opt) (15.2 ) 535 (std) (21.1 ) 770 (opt) (29.9 ) 835 (opt) (32.9 ) 1230.8 (48.8 ) extension cable extension cable 123.8 (4.9 ) 1525 (opt) (60 ) 1675 (std) (66 ) 1900 (opt) (74.8 ) 1975 (opt) (77.8 ) 165.9 (6.5 ) 305 12 13

Planmeca Romexis software Planmeca Romexis is a complete dental imaging software, including all dental imaging modalities: intraoral, panoramic, cephalometric, 3D imaging, dental tomography as well as intraoral video and still camera imaging. With a complete set of tools for image viewing, enhancement, measurements, and annotations, Planmeca Romexis also improves the diagnostic value of radiographs. Printing, image import and export, and DICOM functionalities are also included. Planmeca Romexis platform fully integrates digital imaging with the patient s other clinical data. The system provides direct image capture from Planmeca s X-ray equipment, and interfaces with 3 rd party devices via TWAIN. Together with Planmeca s X-ray equipment, Planmeca Romexis provides a unique safety feature especially useful for teaching environment: the X-ray image capture is inhibited until the supervisor has approved the student s image capture request. Planmeca Romexis computer recommendations Planmeca Romexis client work station Planmeca Romexis server Processor 1 GHz 2 GHz RAM 1 GB 2 GB Hard disk space 40 GB 160 GB Monitor 1280 x 1024 1024 x 768 Peripherals CD R/W or DVD R/W drive CD R/W or DVD R/W drive Backup medium None necessary DAT or equivalent Operating system Windows XP, Windows 2003 Server, Windows Vista, Mac OS X Windows XP Pro, Windows 2003 Server, Windows Vista Other Mac OS X support subject to contract Java platform (Java Virtual Machine 1.6 or later) Java platform (Java Virtual Machine 1.6 or later) The disk space requirements are determined by digital images. Thus the space requirements vary, but a rough estimate is in the order of 1 MB per 2D X-ray image, 7 9 MB per extraoral image, depending on a variety of image specific factors, and 250 MB per 3D image. It is recommended to use the same computer as an application server and as a database server. If Planmeca Romexis server computer is also used for client activities, the hardware should meet both client and server specifications. These specifications are recommended minimum requirements. Not meeting them may lead to degraded performance. DICOM compatibility Media Storage saving images into removable DICOM media Print printing images on film or paper with a DICOM medical printer Storage saving images into DICOM image archive Query/ Retrieve importing digital images from DICOM image archive Worklist importing a patient list from DICOM patient management Storage Commitment confirmation of a successful image storage Planmeca Intra Generator X-ray tube Focal spot Cone diameter Filtration Anode voltage kv rise time Anode current Exposure times SSD (Standard/Long) Constant potential, microprocessor controlled, high frequency 66 khz Toshiba D-0711 SB 0.7 mm x 0.7 mm 60 mm (2.36 in.), rectangular 36 x 45 mm (1.38 x 1.77 in.) min. 2 mm Al 50, 52, 55, 57, 60, 63, 66, 70 kv 8 ms 2, 3, 4, 5, 6, 7, 8 ma DC 0.01 3.2 s, 26 steps 200 mm (8 in.) / 300 mm (12 in.) Line Voltage 100 / 110 115 / 220 240 V ±10% Fusing 15 AT / 8 AT Duty cycle 1:15, automatic control Weight Total 23 kg (51 lbs) Tube head 4.5 kg (10 lbs) Colour White (RAL 9016) Planmeca ProSensor Sensor size Active area Size 0 Size 1 Size 2 33.6 x 23.4 mm (1.33 x 0.92 in.) 25.5 x 18.9 mm (1.0 x 0.74 in.) 39.7 x 25.05 mm (1.56 x 0.99 in.) 31.5 x 20.7 mm (1.24 x 0.81 in.) 44.1 x 30.4 mm (1.76 x 1.2 in.) 36 x 26.1 mm (1.42 x 1.03 in.) Number of pixels 850 x 629 1050 x 690 1200 x 870 Physical pixel size 15 μm x 15 μm 15 μm x 15 μm 15 μm x 15 μm Pixel size 30 μm x 30 μm 30 μm x 30 μm 30 μm x 30 μm Theoretical resolution 33 lp/mm 33 lp/mm 33 lp/mm Resolution 17 lp/mm 17 lp/mm 17 lp/mm Interface USB or Ethernet View delay <5 sec. <5 sec. <5 sec. Technical specifications 14 15

Planmeca Oy designs and manufactures a full line of high technology dental equipment, including dental care units, panoramic and intraoral X-ray units, and digital imaging products. Planmeca Oy, the parent company of the Finnish Planmeca Group, is strongly committed to R&D, and is the largest privately held company in the field. Planmeca Oy Asentajankatu 6 00880 Helsinki Finland tel. +358 20 7795 500 fax +358 20 7795 555 sales@planmeca.com www.planmeca.com Images may contain optional items not included in standard delivery. Available configurations and features may have country or area specific variations. Some products displayed above may not be available in all countries or areas. Rights for changes reserved. 10016321/1209/en