Diesel Generator Sales, Installation, Hire, Spares, Service & Refurbishment

Similar documents
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Diesel Engine Driven Generators Page 1 of 6

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Annex-A TECHNICAL SPECIFICATION

Power Generation. Power Control PCL System Generator Set Control

Magnum Mobile Generator MMG55 Specifications

Atlas Copco Generators

Marine Generating Sets 3.7 to 50 kva

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

The kva RAnge

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

Spark-ignited generator set

Drayton Digistat +2RF/+3RF

SELECTION, APPLICATION AND MAINTENANCE

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENERATOR SETS

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Horizontal Split Case Fire Pumpset Diesel Engine Driven

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

ECOCIAT. Domestic hot water heat recovery unit

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Generators TEM. for small hydroelectric power stations. Electric Machines

Fire Pump Plan Review March 2010

Conventional Fire Detection and Extinguishant Control System Specification

COMMISSIONING OF HVAC SYSTEMS

Diesel Generating Set

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Photovoltaic Solar Energy Unit EESFB

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

WHOLESALE DIRECT INC WEST 65TH STREET

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

DSEULTRA DSE6000 Series Control Module Document Number

STERILIZERS, LABORATORY DRYING OVENS

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

APS100 Rental Generator Set Specification

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

USER S MANUAL HSC-24A

FOXAIR 60/50 ALL MODELS

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

QCS Section 23 Part 2 Fire Alarm and Detection Systems Page 1 2. FIRE ALARM DETECTION SYSTEMS...2

CB200W Water Leak Detection Panel Application Guide

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Emergency voice communications Product Name

Installation and maintenance instructions. Danfoss Vent

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

FIREDEX Conventional Fire Panels

MODEL 2202IQ (1991-MSRP $549.00)

Air Vantage 500 Kubota

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Thyristor-controlled power supplies and battery chargers

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Industrial Generator Set Accessories

7 Lighting Technology

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

ATS - Automatic Changeover

Data Centres A complete solution to noise control and acoustic packages

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Medical Air Systems: Scroll

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz

Mureva Assembly surface mounted wiring devices

EKOS Cart. Instructions for Use

How To Use A Cat Diesel Engine

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice

TIG INVERTER INSTRUCTION MANUAL

Bulk System Gallery. Bulk Storage Systems. OIL SAFE Bulk Storage Systems can be configured or customized to suit your application and budget.

CADB and CADT-D / DI / DC Series

Rotary screw compressors kw 5,5 7, , bar MODULO

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Operational Overview and Controls Guide

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Specification Requirements DBL 700MX and 1000MX Series UPS

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Stove Guard Kit User Manual

Transcription:

Standard Specification Engine ENGINE GOERNOR ELECTRICAL SYSTEM ENGINE PROTECTION FILTERS ANTIFREEZE COOLING SYSTEM EXHAUST STARTING BATTERIES CHARGING Heavy duty industrial diesel engine Manufactured in accordance with B.S.S. 5514 and generally to such International standards as D.I.N. E.I.C., N.E.M.A. In addition the engine is normally capable of providing a 10% overload for a maximum of ONE hour in any TWELE hour period. The engine arrangement is detailed on the attached data sheet. Mechanical compliant with BS5514, class A1 OR Electronic compliant with BS5514, class A1 12/24 D.C electrical system complete with energise to run shutdown solenoid. Oil pressure and water temperature shut down switches and gauge senders. Low oil pressure and High water temperature protections. Filters are provided for: Fuel oil Lubricating oil Air intake The radiator is filled with the correct mix of water and Glycol Antifreeze giving protection to -20 c. This also acts as engine inhibitor to avoid internal corrosion. Radiator and cooling fan complete with protection guards, designed to cool engine at specified output in air-on temperature up to 52 C (125 F). Canopied sets: Residential silencer is supplied mounted within the canopy. Open sets: Industrial type silencer is supplied loose. The engine is arranged for starting by means of an axial starter motor engaging on a toothed ring on the flywheel. The battery is of the high capacity, maintenance free lead acid type and come complete with leads. The battery rack is mounted on the generator base frame. Dual Charging of these batteries is provided by means of an engine driven charge alternator and a constant potential battery charger mounted within the control panel.

Alternator ALTERNATOR REGULATION INSULATION SUPRESSION Brushless design screen protected, fan ventilated, drip-proof, self exciting in accordance with IP22. Fitted with heavy duty long life bearings, lubricant packed for 4000 hours operation. Constructed in accordance with B.S.S.5000 part 99. oltage regulation is maintained within the limits of +/- 1 to 2 % from no load to full load including cold to hot variations at any power factor between 0.8 lagging and unity and inclusive of a speed variation of 4.5%.nominal voltage is set by means of a trimmer mounted within the terminal box before despatch. Stator and rotor insulation is Class "H" standard. Radio and television suppression is provided to comply with B.S.S. 800/1983.

Baseframe, Canopy and Accessories BASEFRAME ANTIIBRATION MOUNTS FUEL TANK COUPLING GUARDS CE CERTIFICATION CANOPY PAINT FINISH MANUALS DRAWINGS FACTORY ACCEPTANCE TESTS & The complete generating set is mounted as a whole on a heavy duty steel base frame. The engine and alternator assembly is isolated from the base frame using anti-vibration mounts. This will reduce the level of vibration transmitted to the base and the surrounding area. The fuel tank forms an integral part of the base plate and has a normal capacity of at least 8 hours operation at full load. The tank is complete with contents indicator, fuel fill cap with breather, fuel feed/return lines to engine and drain plug. NB for sets over 700kA fuel tank is an optional item. The engine is directly coupled to the alternator by means of an SAE flange so there is no possibility of misalignment after prolonged use. The fan, fan drive and battery charging alternator drive are fully guarded for personnel protection. A stone guard protects the radiator core from accidental damage. All machinery placed into operation in the European Union or the European Economic Area must be "CE" certified and marked with the "CE" mark. This mark and the accompanying "Certificate of Conformance" is your assurance that the generating set meets EC legislation. Canopied sets are mounted within a close fitting sound attenuated, weatherproof enclosure designed to reduce the overall noise level to not more than 85DBA at one metre in accordance with E.U. regulations. The canopy is manufactured from mild steel with full length doors on either side for ease of maintenance. All components used are pre treated against corrosion and finished in polyester coating. Canopies are sprayed with two undercoats and finished with two coats of oil proof enamel. One set of operation and engine manuals on CD ROM One set of engine and alternator maintenance books One electrical schematic Standard tests to verify generator operation at 25, 50, 75, 100, 110% Load

TYPICAL CONTROL SYSTEM SHUTDOWN & WARNING INDICATIONS Shutdowns are latching and stop the Generator. The alarm must be accepted and cleared, and the fault removed to reset the module. DISPLA Y NAME COMMON ALARM LED FAIL TO START EMERGENCY STOP LOW OIL PRESSURE HIGH ENGINE TEMPERATURE OERSPEED UNDERSPEED GENERATOR HIGH OLTAGE GENERATOR LOW OLTAGE UNDER FREQUENCY OER FREQUENCY ELECTRICAL TRIPS DESCRIPTION The will also illuminate (Red Flashing). The appropriate LCD icon will also be displayed flashing Enables if the engine does not fire after the pre-set number of attempts has been made a shutdown will be initiated. The LCD will indicate Indicates the Emergency Stop pushbutton has been pressed. Indicates the low oil pressure alarm has triggered. Indicated the high engine temperature alarm has triggered. If the engine speed exceeds the pre-set trip a shutdown is initiated If the engine speed falls below the pre-set trip after the Safety On timer has expired, a shutdown is initiated. If the module detects a generator output voltage in excess of the pre-set trip a shutdown is initiated If the module detects a generator output voltage below the below the pre-set trip after the Safety On timer has expired, a shutdown is initiated If the module detects a generator output frequency in excess of the pre-set pre-alarm, a warning is initiated. If the module detects a generator output frequency below the preset pre-alarm after the Safety On timer has expired, a warning is initiated. Dependant on configuration this will cause a shutdown of the unit NOTE:- The alarm condition must be rectified before a reset will take place. If the alarm condition remains it will not be possible to reset the unit (The exception to this is the Low Oil Pressure alarm and the like, as the oil pressure will be low with the engine at rest). Any subsequent warnings or shutdowns which occur will be displayed steady, therefore only the first-up shutdown will appear flashing.

WARNINGS Warnings are none latching and will self clear if the fault is rectified. BATTERY OLTAGE LOW BATTERY OLTAGE HIGH LOW FUEL (IF FITTED) BATTERY CHARGER FAILURE FAIL TO STOP If the module detects that the plant DC supply has fallen below the low volts setting level. If the module detects that the plant DC supply has risen above the high volts setting level. If the fuel level detected by the fuel level sender falls below the low fuel level setting, a warning will occur. If the module does not detect a voltage from the warning light terminal on the auxiliary charge alternator. If the module detects the engine is still running when the Fail to stop timer expires.

Changeover Switch CHANGEOER SWITCH (ATS 63-1600A) Wall/ Floor mounting intelligent automatic change over switch consisting of a Socomec 4 pole changeover device for mains/alternator load transfer. LCD Display giving Mains Ph-N and Ph-Ph oltage Generator Ph-Ph oltage Mains / Generator Hz Programming facility of controller and timers. Mode selector pushbuttons giving Test with load / Test without load Retransfer Commence (If Programmed) Lamp Test LED Indicator Lamps for Panel Healthy Heartbeat Mains available Mains on Load Generator available Generator on Load Changeover In Manual Handle Mode Changeover In Auto Mode Changeover In Test Off Load Mode Changeover In Test On Load Mode Changeover Awaiting Retransfer Commence (If Programmed) Timers For Delay on Start Delay on Transfer Delay on Re transfer Cool down timer (1 to 25 secs) (1 to 70 secs) (2 min-48secs to 28 mins) (3 secs to 5 mins) Mains Detection For Under & Over Frequency Under & Over oltage

Container CONTAINER When generators are supplied in containers, they are a close walk in type sound attenuated, weatherproof enclosure designed to reduce the overall noise level to not more than 85dBA at one metre in accordance with E.U. regulations. The container is of ISO Container construction and base design and is complete with:- Designed and constructed in accordance with ISO668 series 1 freight containers classifications, dimensions and ratings, Corner fittings to ISO1161, providing four point lifting capability for full wet weight. Personnel Access Doors Min 1 Per Side With Stainless Catches And Hinges Panic Release Door Latches Exterior Emergency Stop Internal lighting One emergency DC bulkhead light complete with push type timer switch located at personnel door. Power cable exit via a non ferrous gland plate in the container wall. Finished In 2 Pack Epoxy Paint Fuel lines and Fluid drains connected to wall sockets for ease of connection Full Acoustic Splitter Ducts Complete With Weather Louvres Cooling Fan And Charging Alternator Fully Guarded Inside Enclosure Typical arrangement