USER INSTRUCTIONS. Worcester Series 75 Actuator Potentiometer Kit. Installation Operation Maintenance. Experience In Motion.

Similar documents
Electri-SAFE DataFlo Digital Electronic Positioner Installation, Operation and Maintenance Instructions

Worcester DS/DM Series UltraSwitch Switch box

12-Volt Negative Ground Installation Instructions

TECHNICAL BULLETIN. Kämmer LinedFlow Corrosive Application Valves. Experience In Motion FCD KMENTB /12

USER INSTRUCTIONS. Limitorque L Actuator. Installation Operation Maintenance. Experience In Motion FCD LMENIM AQ 06/15

Servo Info and Centering

Experience In Motion. Valtek Spring Cylinder Linear Actuators

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

INSTALLATION INSTRUCTIONS

FCD MMASS (Part V400) AN ISO 9001 REGISTERED COMPANY. Ball Valve Actuator Selection

Vogt Valves. The Connection Bulletin for Zero Emission Forged Steel Gate Valves CB 01

Kämmer Series Laboratory Valves

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

FCD VVABR Vogt Valves. Product Overview. Vogt Valves

MXa SIL Guidance and Certification

Vogt Valves The Connection Bulletin for Extended Body Forged Steel Valves Welded Bonnet, Bolted Bonnet, Class 800 & Class 1500 CB 22

Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

Operating Instructions

Speed-Mat Rectangle Cutter

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

SIMRAD SD10 Sailboat Drive

The power module is Feature Number 8800-F2-901.

Wiper Motor Marinco 2.5. Installation Instructions

Flowserve Flow Control Division

HP UPS R1500 Generation 3

Series Hose Reels

Operating Instructions

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

CoolWave r 2 Phase Control Board and Cable Replacement Kits

Model SRMD Setra Remote Monitoring Display

ELECTRONICS G H I J K L M

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

NEXUS FX04 and FX04-1 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION. FX04-1 Shown

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Left Hand Limit Switch. Housing. Left Hand. Connections. Motor Connector BROWN PURPLE GRAY BLACK DARK BLUE BLACK BROWN BROWN LIGHT BLUE.

1/2" (12.7 mm) Conductive Plastic and Cermet Potentiometer

ELECTRIC KNIFE SHARPENER

On/Off Relay Switch and 3-Way Switch Kit

Medium voltage VCP-W MR2 (integral racking)

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

CMD-10k COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

About the BitStorm 6051 POTS Splitter

Electronic Power Control

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Flowserve - Edward Valves Development of the Flowserve Edward Equiwedge Gate Valve

POWERS CONTROL RC 195 Single Input Receiver-Controller

Digi-Motor Installation Guide

INSTALLATION MANUAL. Installation Instructions

About this Manual. Support for Your Product

DIY QUAD. Build Manual V.A 2014

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Advantium 2 Plus Alarm

VEHICLE SPEED CONTROL SYSTEM

Permanent Magnet Motor Kit, Magnetic Reed Type. (SKY-ReedMotorKit) Instructions

Model 2300DR Installation Guide

Powers Controls TH 192 S Single Temperature Room Thermostat

ENCODER TEST MODULE APPLICATION GUIDE

Installation Instructions

Electrically Released Brake ER-825, ER-1225 with Pin Drive Armatues for Montgomery Kone

ATS Overhead Table Shelf System INSTRUCTION MANUAL

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Operating Instructions

TOA 900 SERIES II MIXER POWER AMPLIFIER

Multi-Pitch Pitching Machine USER MANUAL

Cooktop Low-Profile Ventilation Hoods

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Knob Potentiometer FEATURES. P16NP P16NM Panel Cutout. Thickness nut 2 mm washer 1.5 mm. Panel sealing ring 12 wrench Thread M10 x

SERVICE BULLETIN No.1103

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Water Leak Detection System

GPS AutoSteer System Installation Manual

Universal Vehicle Power Supply 9007AX01. Installation Instructions

Knob Potentiometer with Switch

KEYPAD LOCK RETROFIT KIT

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

CortezTM A Kichler Décor Ceiling Fan

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

Cover Page. Factory Radio Other Documents Available For This Vehicle:

Air damper actuators

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

Transcription:

USER INSTRUCTIONS Worcester Series 7 Actuator Potentiometer Kit Single, Dual Installation Operation Maintenance FCD WCAIM207-00 09/0 (Replaces Part 0970) Experience In Motion

Worcester Series 7 Actuator Potentiometer Kit FCD WCAIM207-00 - 09/0 I. General The potentiometer, as part of the Series 7 Actuator, is used to obtain feedback representing the actuator position. It requires a power supply, which may be furnished by the end user and/or by optional devices such as a -7 (-20 ma) Position Indicator or AF17 Positioner. A dual potentiometer is used with the AF17 Positioner or -7 Position Indicator when remote resistance indication is required. The dual potentiometer is required when both AF17 and -20 ma position output or DFC17 and -7 Position Indicator options are to be used together, one pot for each device. For example, each potentiometer can serve only one function, remote resistance monitoring and an AF17 cannot share a potentiometer. For potentiometer wiring with these options or for standard potentiometer wiring, see notes below and the wiring label included with the kit (attached to inside of actuator cover). A wiring diagram is also found in this installation instruction sheet. Also refer to -7 (WCAIM2070) and/or AF17 (WCAIM2031) and/or 7 Actuator (WCAIM2013) and/or DFC17 (WCAIM202) instruction sheets, which can be obtained from your local distributor/supplier, if necessary. II. Mounting and Wiring Potentiometer See illustrations on page 2. A. Operate the 7 actuator to verify 90 operation from open to closed. Adjust limit switches (1), if required, to obtain 90 operation of the actuator. B. With the potentiometer () mounted to the potentiometer bracket (7) or (13) and the spur gear (8) loosely fitted to the potentiometer shaft (11), mount the potentiometer bracket (7) or (13), if not already mounted, as follows: 10-23 7 Actuator Remove the motor module mounting screws (3) on the side of the module farthest away from the actuator shaft (). Line up potentiometer shaft with center of actuator shaft, position potentiometer bracket (7) holes over screw holes, replace and tighten screws. 2-30 7 Actuator Line up potentiometer shaft with center of actuator shaft. Attach potentiometer bracket (13) to motor support plate (1) between the terminal strip () and actuator shaft () with mounting screws (1) as shown. DUAL POTENTIOMETER A dual potentiometer is also available. For mounting use the same procedure as for standard potentiometer kit. C. Run the potentiometer leads (10) to the terminal strip () as shown in the plan views for 10-23 7 and 2-30 7 actuators. D. Connect the potentiometer leads to the terminal strip as follows or see NOTES below: Terminal Strip Wire Color 10 Green 11 White/Black (or White) 12 Purple NOTES: All wiring to terminal strip should be inserted only to midpoint of terminal strip. Single potentiometer or B potentiometer of dual potentiometer has voltage limit of 30 volts. For actuator with AF17 and with dual potentiometer: A pot (closest to the shaft) is wired directly to TB1 on circuit board; B pot (farthest from shaft) is wired to terminal strip terminals 7, 8, 9, if available. For actuator with -7 and with dual potentiometer: A potentiometer is wired directly to TB1 on circuit board, B potentiometer is wired to terminal strip terminals 10, 11, 12, if available. For actuator with AF17 and -20 ma position output together: A potentiometer is wired directly to TB1; B potentiometer is wired directly to TB2 on the AF17 circuit board. For actuator with DFC17 and -7 position indicator together: A potentiometer is wired directly to TB1 on DFC17 circuit board; B potentiometer is wired to terminal block on -7 circuit board. If terminals as noted above are not available for use, potentiometer wires are to be spliced to wires of external device. 2

Worcester Series 7 Actuator Potentiometer Kit FCD WCAIM207-00 - 09/0 III. Adjusting Potentiometer A. 10-30 7 Actuator Place the large face gear (12) over the actuator shaft with the gear teeth down and secure with snap ring (1). NOTE: The face gear utilizes a friction fit to the shaft. For best results, wipe off any lubicant that may be on the shaft before sliding on the face gear. a CAUTION: Do not overstretch the snap ring. Use the minimum opening to allow it to slip over the gear. B. Adjust the potentiometer spur gear (8) until there is approximately 1 1" engagement with the large face gear. Tighten the spur gear set screw (9). If necessary, slightly bend potentiometer bracket to get proper engagement. C. Rotate the face gear back and forth to ensure smooth and easy operation of the potentiometer. D. For 90 Valves With the actuator either in the OPEN (full CCW) or CLOSED (full CW) position, and power off, rotate the face gear, thus turning the potentiometer shaft, until the resistance between the white/black lead (terminal 11) and the green lead (terminal 10) or the white/ black lead (terminal 11) and the purple lead (terminal 12), respectively, as measured by ohmmeter, is between 80 and 90 ohms. (Refer to instruction sheets listed in section I for potentiometer lead locations and adjustments with other options.) NOTE: It is not necessary to loosen or remove face gear snap ring to rotate gear. E. Power the actuator to the opposite position from where resistance was measured. F. At this position, with power off, measure the resistance at the same terminals as stated above. The resistance reading should be greater than 700 ohms. If not, then power actuator back to original position and adjust potentiometer again, if necessary, as stated in paragraph E above. NOTE: If unsuccessful in getting proper resistance readings, potentiometer is defective and should be replaced. The feedback potentiometer is now adjusted for use in the 7 actuator. Attach the potentiometer caution label to the outside of the actuator cover. IMPORTANT: The feedback potentiometer is calibrated for only one 90 quadrant of valve operation. If the output shaft is repositioned to another 90 quadrant or if the output shaft is rotated a multiple of 30 from its original position, the feedback potentiometer will no longer be in calibration and must be recalibrated. 3

Worcester Series 7 Actuator Potentiometer Kit FCD WCAIM207-00 - 09/0 Wiring for 10-30 P/D 7 Feedback Potentiometer Option FOR AF17 WITH DUAL POTENTIOMETER ("B" SECTION ONLY) SINGLE FEEDBACK POT OR -7 OPTION WITH DUAL POT ("B" SECTION ONLY) 1 3 GREEN WHT/BLK CW PURPLE GREEN WHT/BLK 2 CW PURPLE INTERNAL 1 2 3 7 8 9 10 11 12 NOTE: Single Feedback Pot or "B" Section of Dual Pot Has Voltage Limit of 30 Volts. CUSTOMER CONNECTIONS CUSTOMER CONNECTIONS EXTERNAL

1 2 3 7 8 9 10 11 12 Worcester Series 7 Actuator Potentiometer Kit FCD WCAIM207-00 - 09/0 Illustrations show single potentiometer only. 10-23 7 Plan View (See NOTES in Section II, D) 1 View A-A 1 12 1 3 2 7 9 8 11 10 12 A GREEN WHT/BLK PURPLE 8 9 11 A 17 2 3 7 10 Item Description 1 Limit Switches 2 Motor Module 3 Motor Module Mtg. Screws (2) Terminal Strip Actuator Shaft Potentiometer 7 Potentiometer Bracket 8 Spur Gear 9 Spur Gear Set Screw 10 Potentiometer Leads 11 Potentiometer Shaft 12 Face Gear 13 Potentiometer Bracket 1 Mounting Screws (2) 1 Motor Support Plate 1 Snap Ring 17 Lockwashers (2) 18 Nut 18 2/30 7 Plan View (See NOTES in Section II, D) B B View B-B 9 8 11 17 1 12 13 1 18 10 1

Worcester Series 7 Actuator Potentiometer Kit FCD WCAIM207-00 - 09/0 This page is intentionally blank.

Worcester Series 7 Actuator Potentiometer Kit FCD WCAIM207-00 - 09/0 This page is intentionally blank. 7

United States Flowserve Flow Control Worcester Actuation Systems 11 Woodall Road P.O. Box 11318 Lynchburg, VA 20-1318 Phone: 3-28-00 Fax: 3-8-973 FCD WCAIM207-00 Printed in USA. (Replaces Part 0970) To find your local Flowserve representative: For more information about Flowserve Corporation, visit www. or call USA 1 800 22 989 Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation Operation Maintenance (IOM) instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 200 Flowserve Corporation, Irving, Texas, USA. Flowserve is a registered trademark of Flowserve Corporation.