Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. Molten-in Liquid Level Indicator

Similar documents
Float and Thermostatic Traps Series H, C and X

Maintenance and Instruction Manual. December 2011 Rev. 01 Page 1 of 12

Unique DV-ST UltraPure - Manuel: for valve sizes DN8 to DN80 (¼ to 3 )

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

GATE VALVES ASAHI AV VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

PBX Series Quick Fit Connector Bimetallic Steam Traps

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

IMPORTANT SAFETY NOTICE

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

API Flanged Safety Relief Valves Series 526 CATALOG

Load Limiter ULS-60 ULS-80 ULS-100 ULS-125. Table of Contents. Assembly Instructions Load Limiter ULS-60, -80, -100, -125

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.7

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

OPERATION MANUAL SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR BRICKLAYER S PULLEY

VALVES FOR REFRIGERATING SYSTEMS

INSTALLATION, OPERATION & MAINTENANCE MANUAL

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

SureSite Magnetic Liquid Level Indicator

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Oil and Coolant Circulating Heating System. Model - OCSM

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Maintenance and Service Instruction

ROTEX SD shiftable jaw coupling

Machine needle shut-off nozzle type HP

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

SunMaxx Solar Filling Station Operating Instructions

Operating Instructions

Guide to good leak testing

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

James M. Pleasants Company

Select Radiators Installation Guide

Weatherproof Tournament Table Tennis Table

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

This instruction is valid for all ACD pump models shown on page 2

Instruction Manual Differential Pressure Transmitter

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

V47 Series Temperature Actuated Modulating Water Valves

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Pressure regulating valve with modulating kit, type DRV

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

81000 Series Aluminum Gate Valve Installation and Repair Manual

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Mounting Instructions. Torque Transducer. A en

Cooling system components, removing and installing

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

HYDRAULIC LIFT TABLE CART 2200-LB.

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Volkswagen Golf > VW Rabbit GTI 2006->

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Pneumatic actuators The Original! Technics of the top class.

Operating and installation instructions

ALMATEC Series CX CX 10 CX 130

1000-LB. TRAILER JACK OWNER S MANUAL

Doc. No. NDP 015M-15 MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS. DP-10 series

INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR. HYDRAULIC PUMP type HP 03L, 05L, 07L volume 3 l, 5 l, 7 l

San josé OWNER S MANUAL

2" & 3" Poly Wet Seal Pump Instruction Manual

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Installation Instructions

Installation and safety instructions for AC/DC built-in devices

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

Fisher 249 Caged Displacer Sensors

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

SINGLE STAGE INLINE FIRE PUMP

Infrarot-Bewegungsmelder IP44

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

10 TON HYDRAULIC PRESS

SISTO-16TWA/HWA/DLU. Type Series Booklet

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Doc. No. NDP 009M-32 MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS. NDP- 5 series NDP-15 series

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

3097 en / e. This manual is to be given to the end user POULIBLOC Shaft mount reducer. Installation

Overflow valve with thread connection

MODEL J SERIES CONVERTER

NITROUS TRANSFER PUMP INSTRUCTIONS

Operation & Maintenance Manual

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

CHROME FRONT BRAKE MASTER CYLINDER KIT

Druck PV 62x pneumatic/hydraulic pressure stations

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

XL PREMIUM OIL COOLER KIT

Universal Installation and Maintenance Instructions 71CD-1212 Spill Containment Bucket

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Transcription:

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU Molten-in Liquid Level Indicator Please read these operating instructions carefully to ensure a safe operation and keep the same for further use. 2016 Armaturenwerk Altenburg GmbH Am Weißen Berg 30 04600 Altenburg, Germany

Contents Safety... 4 Authorized personnel... 4 Residual dangers... 4 Symbols used for safety information... 4 General safety information... 5 Other information... 5 Description of level indicator... 6 Types and connections... 6 Product description... 7 Identification... 7 Technical parameters... 7 Design Features... 8 Transport and Storage... 9 Mounting... 9 Principles... 9 Mounting preparation... 9 Installating the level indicator...10 Commissioning...11 Principles...11 Steps of commissioning...11 Operation, Maintenance and Repair...12 Principles...12 Repair...12 Dismantling and Disposal...13 Principles...13 Document 90000711 Revision 00 Sh. 3 of 14

Safety The molten-in liquid level indicator, hereinafter referred to as level indicator, is designed for use in refrigeration/air conditioning systems referred to as systems hereinafter. It may only be put into service if installed into the system unchanged in accordance with these instructions and as a whole is compliance with the statutory provisions. The level indicator incorporates state-of-the-art technology and has been built according to the applicable regulations. Great value has been set upon the user s safety. These operating instructions are integral part of the contract and shall be kept throughout the entire life of the level indicator. Authorized personnel Only trained and instructed personnel shall be allowed to do any work on the level indicator. As regards the qualification and expertise of the personnel the applicable rules and guidelines shall apply. Residual dangers Unavoidable residual dangers may emanate from the level indicator. Every person working on this device shall therefore carefully read these instructions. To be observed are for example: - the generally accepted safety regulations, - EC directives, - Norms (e.g. EN 378) and all national provisions. Symbols used for safety information Instructions on preventing imminent serious danger to persons. Imminent most serious injuries or death as a possible consequence. Any non-observance may lead to an immediate failure of the level indicator. Instructions on preventing potential serious danger to persons. Avoidable serious to very serious injuries or death as a possible consequence. Any non-observance can cause the level indicator to fail. CAUTION! Instructions on preventing a minor danger to persons. Minor, reversible injuries cannot be excluded. Any non-observance may lead to a medium-term failure of the level indicator. ATTENTION! Instructions on preventing potential damage to equipment. Minor, reversible injuries cannot be excluded. Any non-observance may lead to a medium-term failure of the level indicator. Sh. 4 of 14 Document 90000711 Revision 00

General safety information These operating instructions are based on the safety requirements of DIN EN 378-2 and DIN EN 12178. Instructions to prevent dangers in all cycles of service life: Risk of bursting if operated beyond the technical parameters. Most serious injuries and immediate system failure possible. Observe the technical parameters. Damage due to improper handling. Serious injuries and system failure possible. Never use the level indicator as transport, lifting or lashing point. Any non-observance of the instructions may cause the level indicator to fail. Avoidable serious to very serious injuries or death possible. Installation, operation and maintenance by authorized trained personnel only. Risk of service fluid to be released. Depending on the kind of service fluid serious to very serious injuries or death possible. Wear personal protective equipment (e.g. respirators, gloves). CAUTION! Very cold or very hot surface temperatures possible. Frostbites/burns possible. Wear personal protective equipment (e.g. respirators, gloves). Other information The information contained herein represents to the best of our belief our knowledge at the time when these instructions were prepared. It shall serve as code of practice to ensure a safe handling of the level indicator in transport, storage, installation, commissioning, maintenance and dismantling/disposal. A final decision as to whether the level indicator suits the purpose is to be taken by the user. This information shall not be deemed a warranty of quality. Any modification of the level indicator and operation under other than the prescribed parameters shall not be allowed and will result in the loss of the conformity declaration and all liability claims. Document 90000711 Revision 00 Sh. 5 of 14

Description of level indicator Types and connections Operating Instructions for Molten-in Liquid Level Indicator Installation dimensions can be gathered from the AWA product catalogue and technical documents respectively. The connecting options and types are explained in more detail under "Design features". Sh. 6 of 14 Document 90000711 Revision 00

Product description The level indicator is designed for direct visual display of liquid level in components of refrigeration or air conditioning systems. The level indicator can be installed in liquid receivers, containers, compressor housings or pipe. For better visibility of the liquid level the device can be supplied on request with reflective glass or with a float. The level indicators consists of a sight glass molten pressure-tight into a metal casing. The level indicator is in compliance with DIN EN 12178:2003 and Pressure Equipment Directive 2014/68/EU and follows DIN 7079. Identification The level indicator is marked in accordance with DIN EN 12178 as follows: Mar of manufacturer Coded year of manufacture Maximum allowable pressure TÜV notified body if TÜV-certified Part number Technical parameters Pressure/Temperature allocation: Depending on data indicated in the technical documentation. Media used: Refrigerant as per DIN EN 378-1-2012, PED fluid group 2 and relevant refrigeration compressor oils according to DIN 51503-1. On request other refrigerants can be permitted (e.g. R290, R717) depending on data indicated in the technical documentation. Leakage test: according to DIN 8964-3 (<4.1 g/a R-134a at 10bar) Strength test: according to DIN EN 12178 at 1.43-fold PS Classification pursuant to Pressure Equipment Directive (PED 2014/68/EU): The level indicator is a pressure-retaining component. Approval according to TÜV Pressure Equipment Directive (PED 2014/68/EU): EC design examination (audit report 0662/1939/14) Manufacturer s approval according to Module A1 and C1 (Certificate 0090 151 0111) Document 90000711 Revision 00 Sh. 7 of 14

Design Features The material of the level indicator components and the manufacturing method are selected in conformity with the DIN EN 12178 and Pressure Equipment Directive 2014/68/EU thus guaranteeing the reliability for the operating range indicated. The glass lens of the level indicator is molten pressure-tight into the steel casing. The different coefficients of expansion of glass and metal provide for a homogenous compressive stress over the entire glass body. This is why the level indicator behaves like tough material according to the "leak before break" principle. Types: Screwed level indicator level indicator with external thread (optionally: cylindrical metric thread DIN 13, tapered pipe thread NPT ANSI/ASME B1.20.1 and B1.20.3, cylindrical pipe thread ISO 228 and Unified screw thread ASME B1.1) screwed by means of a gasket/seal ring or by way of a pressure-tight joint into a mating part that has a suitable internal thread. The following types of level indicators are available: D smooth lens DS smooth lens with float DR reflective glass DI smooth lens with indicator. Rotalock level indicator Level indicator for Rotalock connection with Rotalock union nut, seal ring and Rotalock level indicator. The threaded joint comes as Unified screw thread ASME B.1.1. The following types of the level indicator are available: RL smooth lens RLR reflective glass RLF smooth lens with Rotalock union nut RLF SET smooth lens with cage, float, gasket and Rotalock union nut. Flange-type level indicator Level indicator to be screwed on (3 to 6 screws), sealed by O- ring. The following types of level indicators are available: D smooth lens DR reflective glass The level indicator comes with galvanized surface. This kind of coating ensures protection against corrosion until installation if handled and stored in dry condition. Suitable connecting components are available in the AWA delivery program. Sh. 8 of 14 Document 90000711 Revision 00

Transport and Storage Mounting Principles Transport the level indicator by closed means of transport in the original packing protected against weather influences and store it in dry areas. The level indicator and/or the connecting piece shall be arranged in the system so that it can be operated properly and that it is and protected from possible hazards. Damage of level indicator / connecting pieces possible. Serious injuries and system failure possible during operation. Level indicator / connecting pieces to be installed without additional loads (forces, vibrations, etc.). Removal space shall be so that the level indicator can be properly mounted by use of a tool and at the necessary torque. Only authorized personnel shall be allowed to mount the valve. Any non-observance of these instructions may cause the level indicator to fail. Most serious injuries and death possible. Mounting by personnel trained in refrigeration systems only. No modifications of the level indicator and/or in-line housing are permitted. If modifications become necessary, they have to be agreed with the manufacturer prior to mounting. Product features may change. Avoidable serious to very serious injuries or death possible. Any modification has to be agreed with manufacturer in advance. Mounting preparation 1. The connecting piece must have been installed and cooled in the system/component already. The sealing surfaces of the installed connecting pieces must be free of any damage. Any non-observance of these instructions may cause the level indicator to fail. Very serious injuries or death possible. Install the connecting piece without level indicator. 2. In the condition as supplied the level indicator may be provided with an additional transport protection. To avoid corrosion inside the level indicator or contamination, leave the transport protection in place until mounting. ATTENTION! Damage of internal components possible. Malfunction due to contamination of internal components. Remove the transport protection shortly before mounting. Document 90000711 Revision 00 Sh. 9 of 14

Installating the level indicator 1. The dimension of the connecting piece must fit that of the level indicator. If not, use adapters. 2. Initially fasten the level indicator to the connecting piece using a suitable gasket and, if necessary, other components (cage, float ball). Pay attention to a correct position of the components and avoid damage. Then, tighten the level indicator using a positive-fit tool until the prescribed torque is reached. Make sure the level indicator is mounted free from mechanical constraint. Tighten it crosswise in min. two steps applying the given torque. Any exessive torque or non-observance of the mounting order may cause failures. Serious injuries and system failure possible during operation. Keep the mounting order, screw order and torque. 3. Depending on the type and thread and size resp. the following torques are applicable (Nm): Screwed level indicator: Thread Gasket Torque Thread Gasket Torque Thread Torque M24x1 O-ring 50 +10 G 1/2 O-ring 50 +10 1/2 NPT 60 +10 M25x1 O-ring 50 +10 G 3/4 Aluminium gasket 90 +10 3/4 NPT 90 +10 M26x1.5 Aluminium Aluminium 120+30 G 1 gasket gasket 150+20 1 NPT 140 +10 M36x1.5 Aluminium 1 180+20 190 +10 gasket 1/4 NPT M52x2 Aluminium Aluminium 1 250+30 G 1 1/2 250+30 275 +10 gasket gasket 1/2 NPT 1 1/8-18 Fibre flat O-ring 50 +10 G 2 UNEF gasket 120 +20 2 NPT 340 +10 Note: Level indicator with NPT thread to be mounted only once. Selants may be used for NPT threads. Rotalock level indicator: Size Thread Torque RL 1 1/4 1 1/4 12 UNF 100 +10 RL 1 3/4 1 3/4 12 UN 150 +10 RL 2 1/4 2 1/4 12 UN 170 +10 Flange-type level indicator: Thread Torque M 6 8 +2 M10 45 +5 Sh. 10 of 14 Document 90000711 Revision 00

Commissioning Principles The level indicator except the connecting piece has already been checked for tightness and strength by the manufacturer. The level indicator and the system, into which it is installed, may only be commissioned if they have been checked, with due regard to the intended mode of operation, for proper condition as to assembly, installation, set-up conditions and safe functioning. After mounting and initial start-up according to DIN EN 378-2:2012 check again for leakage and strength and an effective corrosion protection. Steps of commissioning 1. Check the system for resistance to pressure by suitable means (e.g. helium, dry nitrogen). Danger of bursting of level indicator. Most serious injuries possible. The test pressure must not exceed the maximum allowable pressure (PS). Strictly observe the safety information (e.g. DIN EN 378). 2. It is absolutely necessary to apply an anticorrosive coating that suits the operating conditions because the level indicator with a temporary corrosion protection only. Make sure that the fabrication data remain legible. CAUTION! Delayed failure due to corrosion possible. Serious injuries and failure of system during operation possible. Apply a suitable anticorrosive coat. ATTENTION! Loss of product conformity due to illegible marking. Warranty becomes null and void. Marking/signing must be legible! 3. Evacuating and filling the system with refrigerant. Danger of bursting if operated beyond the technical parameters. Most serious injuries possible. Observe the technical parameters of the level indicator. Make sure the system is not filled with an excessive amount of refrigerant. 4. Never cool down or heat up the level indicator abruptly. The temperature gradient of the level indicator shall not exceed 30K. CAUTION! Cracks with resulting leaks in the glass lens possible. Injuries and failure of system during operation possible. Observe temperature differences. Document 90000711 Revision 00 Sh. 11 of 14

Operation, Maintenance and Repair Principles Operating Instructions for Molten-in Liquid Level Indicator The level indicator is maintenance-free. When cleaning make sure the temperature difference between the cleaning agent and the level indicator is not too big. Release of refrigerant possible. Release of refrigerant may lead to most severe injuries. For repairs the system must have an adequate temperature, free of refrigerant and sufficiently ventilated. As part of the regular system inspection it should be checked for corrosion/damage and operability and its proper condition restored if necessary. Media contact possible, contact with hot/cold surfaces. Burns, frostbites Wear personal protective equipment as prescribed by national regulations during maintenance and inspections. Repair If the level indicator needs repair, shut down the system, drain the refrigerant from the system (or system section) in an environmentally friendly manner and ventilate the system. Release of refrigerant possible. Release of refrigerant may lead to most severe injuries. For repairs the system must have an adequate temperature, free of refrigerant and sufficiently ventilated. For repairs use no other than original spare parts. For mounting/start-up follow these operating instructions. It is absolutely necessary to use a new gasket and do a leakage and strength test once again. AWA assumes no warranty for tightness after repairs. Level indicator damage due to defective spare parts/mounting. Avoidable serious injuries and system failure possible. Use no other than original spare parts for repairs. Sh. 12 of 14 Document 90000711 Revision 00

Dismantling and Disposal Principles To dismantle the level indicator, shut off the system, remove the refrigerant from the system (or system section) in an environmentally friendly manner and sufficiently ventilate the system (or system section). Release of refrigerant possible. Release of refrigerant may lead to most severe injuries. For repairs the system must have an adequate temperature, free of refrigerant and sufficiently ventilated. Media contact possible, contact with hot/cold surfaces. Burns, frostbites Wear personal protective equipment as prescribed by national regulations during maintenance and inspections. The level indicator and its components can be recycled: level indicator: cage / float ball: Dust caps: iron scrap plastics plastics (PE) Document 90000711 Revision 00 Sh. 13 of 14

Armaturenwerk Altenburg GmbH Am Weißen Berg 30 D-04600 Altenburg Germany Telephone +49 (0) 3447-893-0 Telefax +49 (0) 3447-811-10 Internet: E-Mail: http://www.awa-armaturenwerk.de info@awa-armaturenwerk.de Subject to change as of: 03.2016 Document 90000711 Revision 00