FALK TYPE PA PUMP & COOLER ASSEMBLIES (AIR/OIL) All Falk Gear Drives

Similar documents
300 Series PA Pump and Cooler Assemblies

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Diesel Engine Driven Generators Page 1 of 6

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Horizontal Jet Pumps 1/3-1-1/2 HP

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

FLASH TANK ECONOMIZER PRODUCT GUIDE

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

MAC-120HE-01 Air-Cooled Chiller

Quiz On Information Learned From Chapter 1

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Commercial Gas Furnace Upflow

Model 1210C Battery Powered Pump Shown. Description

Goulds Water Technology

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

C18 ACERT Fire Pump Tier bkw/ rpm

BOWIE PUMPS OPERATION - MAINTENANCE

Oil and Coolant Circulating Heating System. Model - OCSM

TECHNICAL INFORMATION Bulletin

Centrifugal Fans and Pumps are sized to meet the maximum

Rexroth Hydraulic Pump A10VO Series User Manual

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

We will discuss common industrial applications with guides for the proper use of electric motors on these.

Fire Pump Plan Review March 2010

Vertical Pumps for the Oil & Gas Industry

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Explosion-Proof Electric Unit Heaters

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance

VERTICAL TURBINE AND PROPELLER PUMPS

COMMISSIONING OF HVAC SYSTEMS

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

Air Eliminators and Combination Air Eliminators Strainers

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

AC Electric Motors best practice

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

REGULATORS 175/153 Series

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Conlift1, Conlift2, Conlift2 ph+

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

IMPORTANT SAFETY NOTICE

Technical Specification. Generating Set with Waukesha engine burning natural gas

Cooling system components, servicing

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

ECOCIAT. Domestic hot water heat recovery unit

Pumping Fuel & Fuel Oil

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

Cooling Capacity CFM in. w.c. (125 Pa)

Basic Nameplate Information

Hydraulic Control Solutions

NITROUS TRANSFER PUMP INSTRUCTIONS

A Guide to Trouble-Free Cooling Towers

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

Transformer oil cooler ALFA A02

PUMP AND MOTOR DIVISION

Cooling Systems. Table of Contents

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

FAIRBANKS NIJHUIS FIRE PUMPS.

BB-18 Black Body High Vacuum System Technical Description

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Automatic Self-Cleaning Strainers

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

3516 Industrial Engine

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Installation and Start-up Instruction

AABC Specifications for Testing and Balancing HVAC Systems

Single- and Multi-circuit Pumps

Hydraulic Trouble Shooting

MEMBRANE VACUUM MINI PUMPS

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Energy Recovery Device isave 21-40

The Yachtmans Choice...

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Hydraulically actuated clutches and spring-applied brakes clutch/brake combined units

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

WATER pressure. Issue 3 / Clear water pumps for domestic and commercial applications

SECTION AIR CONDITIONING UNIT

Transcription:

FALK TYPE PA PUMP & COOLER ASSEMBLIES (AIR/OIL) SELECTION GUIDE All Falk Gear Drives

Selection Guide 131-315, November 2002 Type PA Pump & Cooler Assemblies With Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate thermal energy, Rexnord offers the following cooling accessories: Shaft Driven Cooling Fans Electric Cooling Fans Cooling Tubes Type PC Pump and Cooler Assembly (Water/Oil) Type PA Pump and Cooler Assembly (Air/Oil) Rexnord recommends the most economical cooling accessory that meets the demands of the application and any associated customer specifications. Pump & cooler assemblies are commonly suggested when the thermal requirements exceed that which can be accommodated by shaft driven fans, electric cooling fan, or cooling tubes. Notice: Pump and cooler assemblies described in this guide are offered as oil cooling devices for use on gear drives that are splash lubricated (splash assures adequate oil flow to bearings and gearing regardless of whether the pump & cooler assembly is activated). When gear drives require pressure lube, jet lube, or other dependencies associated with continuous flow of lubrication supplied by the lube pump, refer to Factory. Type PA Pump & Cooler Assemblies with Air/Oil Heat Exchanger are typically preferred when water is unavailable, water is corrosive, or where water is subject to freezing. This selection guide covers Type PA Pump & Cooler Assemblies with Air/Oil Heat Exchanger. Six sizes are available. See Table 1, on Page 3, which provides the thermal capacity of each size of Type PA Pump and Cooler Assembly, as well as a general description of the individual components that make up each size. Rexnord reserves the right to substitute equivalent brands of components. Each Type PA Pump and Cooler Assembly includes oil lube pump and associated lube pump motor, coupling (motor to lube pump), air/oil heat exchanger, oil filter, heat exchanger bypass valve, all pre-assembled with preformed hydraulic tubing and tube fittings on a common steel mounting plate which can be bolted to a suitable foundation. Type PA Pump & Cooler Assemblies are furnished to be floor mounted. Rexnord furnishes only oil piping from the lube pump to the heat exchanger inlet. Refer to Table 2, on Page 4, for recommended lube line sizes of the customer furnished oil suction and oil discharge lines. Oil Immersion Heater Lubricant viscosity recommendations shown in Rexnord service manuals for enclosed gear drives are applicable to these pump and cooler assemblies. However, for operation at ambient temperatures at less than 50 F (10 C), a gear drive equipped with Type PA Pump & Cooler Assembly should also be equipped with an oil immersion heater (extra charge option). Temperature Switch When gear drives equipped with pump and cooler assemblies are started after extended idle periods, lubricant in the gear drive sump will not be at operating temperature, and may be at viscosities exceeding 8000 SSU (1725 cst). Startups with lubricant at elevated viscosity levels can result in pump cavitation, pump motor overload, and damage to components. Where cold start situations are anticipated, specify a temperature switch (extra charge option) when ordering the pump and cooler assembly. Installation & Maintenance Caution Lock out power source and remove all external loads from the gear drive before servicing the gear drive or accessories. For detailed maintenance instructions and specifications for components such as heat exchanger, oil filter, lube pump, etc, refer to the product manufacturer s literature. When ordering parts, or requesting information, provide the Rexnord M.O. Number, gear drive size, H.S. shaft rpm, ratio, and date that are stamped on the gear drive nameplate. Always locate floor-mounted pump and cooler assemblies in close proximity to the gear drive to minimize pressure drop in the oil lines. It is recommended that oil lube pumps be mounted below the gear drive oil level to maintain a prime. Minimum lube line sizes are indicated in Table 2, on Page 4. When requested, and where determined feasible by Rexnord Engineering, pump and cooler assemblies may be mounted directly to the gear drive at additional charge. When pump and cooler assemblies are mounted on the gear drive by Rexnord, all oil line connections are completed by Rexnord. Pre-selected thermometer and pressure gauge are available as extra charge options. Contact Rexnord for other requirements including switch to activate warning device, flow indicator/switch, oil heater, oil sump tank, water control device, non-standard components, etc. Copyright 2002. Rexnord Industries, LLC. All Rights Reserved. Litho in USA. FALK and a good name in industry are trademarks of Rexnord. The contents of this selection guide are subject to change without notice or obligation. Information contained herein should be confirmed before placing orders. Refer to gear drive certified prints for final designation of components, and exact location and description of inlet/outlet hookup points. The atmosphere in the immediate area of the Pump & Cooler Assembly must be free of lint, dirt, etc. to maintain efficient operation of the assembly. Prior to filling gear drives with oil, remove the gear drive inspection cover and flood the oil troughs to insure a generous flow of oil to the bearings. 2 (131-315) Rexnord Industries, LLC, 2002.

Quick Selection Method Type PA Pump & Cooler Assemblies The following selection method is conservative, and assumes the pump & cooler assembly will dissipate the complete thermal burden. Contact Rexnord when an optimized selection is required. Optimized selections also take into account thermal dissipation contribution from gear drive housing surfaces, and gear drive sump capacity. Notice: For Falk gear drives, Types ABX and AXV, use pre-selected pump and cooler assemblies indicated in Table 5. 1. Determine the Power Rating of the Prime Mover. It is not necessary to use a service factor. 2. Determine BTU/Hr that will be used to select the pump & cooler assembly as follows: If the Prime Mover is rated in Horsepower Single Reduction Gear Drives BTU/Hr = Power Rating of the Prime Mover (HP) X 38.2 Double Reduction Gear Drives BTU/Hr = Power Rating of the Prime Mover (HP) X 76.4 Triple Reduction Gear Drives BTU/Hr = Power Rating of the Prime Mover (HP) X 114.6 If the Prime Mover is rated in Kilowatts Single Reduction Gear Drives BTU/Hr = Power Rating of the Prime Mover (kw) X 51.3 Double Reduction Gear Drives BTU/Hr = Power Rating of the Prime Mover (kw) X 102.5 Triple Reduction Gear Drives BTU/Hr = Power Rating of the Prime Mover (kw) X 153.7 3. From Table 1, choose the size of pump & cooler assembly that has a Max Dissipation BTU/Hr that equals or exceeds the BTU/Hr that was determined in Step 2. Note that each size of pump & cooler assembly has two values for Max Dissipation BTU/Hr, one value when the pump motor is 60 Hz, and a lower value when the pump motor is 50 Hz. 4. Dissipation rates (BTU) in Table 1 are based on sea level elevation and ambient temperature of 80 F (27 C). See Tables 3 & 4, on Page 4, in order to correct for alternate altitude or ambient temperature. Selection Example Prime mover is 750 HP at 1750 rpm Available electric source to drive pump motor is 60 Hz Mechanical Service Factor is 1.25 Nominal ratio of the gear drive is 5.60:1 The gear drive is splash lubricated From Selection Guide 131-110: Size of the gear drive is 425A2, double reduction, (mechanical service factor = 1215/750 = 1.62) Power Rating of the Prime Mover is 750 HP BTU/Hr for double reduction gear drive, with Prime Mover rated in HP = 750 HP X 76.40 = 57,300 BTU/Hr From Table 1, choose 220PA, which provides Max Dissipation of 79,700 BTU/Hr with 60 Hz pump motor Table 1 Typical Specifications for Type PA Pump & Cooler Assemblies (Air/Oil) Pump & Cooler Assembly 205PA 210PA 220PA 230PA 240PA 250PA Lube Pump HAIGHT or Equal HAIGHT or Equal HAIGHT or Equal HAIGHT or Equal HAIGHT or Equal HAIGHT or Equal Coupling LOVEJOY or Equal LOVEJOY or Equal LOVEJOY or Equal LOVEJOY or Equal LOVEJOY or Equal LOVEJOY or Equal Heat Exchanger & Electric Fan 16 Dia & Electric Fan 22 Dia & Electric Fan 22 Dia & Electric Fan 24 Dia & Electric Fan 30 Dia & Electric Fan 36 Dia Filter - 20 micron PARKER or Equal PARKER or Equal PARKER or Equal PARKER or Equal PARKER or Equal PARKER or Equal Pressure gauge (Optional) Furnished Only When Specified ASHCROFT or Equal ASHCROFT or Equal ASHCROFT or Equal ASHCROFT or Equal ASHCROFT or Equal ASHCROFT or Equal Thermometer (Optional) Furnished Only When Specified ASHCROFT or Equal ASHCROFT or Equal ASHCROFT or Equal ASHCROFT or Equal ASHCROFT or Equal ASHCROFT or Equal Lube Pump Motor Options 60 Hz AC Electric Motor 50 Hz AC Electric Motor 60 Hz AC Electric Motor Heat Exchanger Fan Motor Specifications Typical Motor HP Lube Pump Heat Exchanger Fan Pump Oil Flow Rate Max Dissipation BTU/Hr 3 GPM 31,000 1.00.25 2.5 GPM 25,700 5 GPM 49,700 2.00.25 4 GPM 41,800 208-230/460 Volt/3 Phase/60Hz/TEFC 3.00.25 5.00 1.00 7.50 1.00 Rexnord reserves the right to substitute equivalent brands or components. Lube pump HP shown is a minimum value based on lubricant viscosity <8000 SSU (1725 cst), and appropriate customer lube piping (length, diameter, elevation, free of excessive bends/elbows). Dissipation rates (BTU) are based on sea level elevation and ambient temperature of 80 F (27 C). See Tables 3 and 4 in order to correct for alternate altitude or ambient temperature. 11 GPM 79,700 9 GPM 68,100 20 GPM 150,000 17 GPM 131,000 29 GPM 222,000 24 GPM 191,000 40 GPM 311,000 10.00 3.00 36 GPM 277,000 Rexnord Industries, LLC, 2002. (131-315) 3

TABLE 2 Type PA Pump & Cooler Assemblies Minimum Lube Line Sizes Lube Line Function Oil Suction Line Gear Drive to Pump Inlet Oil Discharge Line Heat Exchanger Outlet to Gear Drive Lube Line Length, Feet Minimum Lube Line Inside Diameter, Inches PA Size 205PA 210PA 220PA 230PA 240PA 250PA 3 1.00 1.00 1.25 1.75 2.00 2.25 5 1.00 1.25 1.50 1.75 2.00 2.25 10 1.25 1.50 1.75 2.00 2.25 2.50 15 1.50 1.50 2.00 2.25 2.50 2.50 20 1.50 1.75 2.00 2.25 2.75 2.75 5 0.75 1.00 1.25 1.25 1.50 1.50 10 1.00 1.00 1.25 1.50 1.75 1.75 15 1.00 1.25 1.50 1.75 2.00 2.00 20 1.25 1.25 1.50 1.75 2.00 2.25 25 1.25 1.25 1.75 2.00 2.00 2.25 NOTES: 1. Minimum lube line sizes assume the use of a lubricant meeting Rexnord recommendations, and that lubricant entering the oil inlet of the pump is at a nominal viscosity not exceeding 8000 SSU (1725cSt). 2. Assumes pump inlet located below gear drive outlet. 3. To achieve optimal system performance, it is strongly recommended that pump and cooler assemblies be located as close as possible to the gear drive, thereby minimizing the length of lube lines. Lube lines should be constant diameter, and free of unnecessary bends and elbows. Observing these recommended measures will reduce the potential for line losses (pressure drop) and cavitation. Table 3 Altitude Factor Altitude ft Sea Level = 0 Altitude meters Sea Level = 0 Factor 0 to 2,500 0 to 762 1.00 2,500 762.95 5,000 1 524.90 7,500 2 286.85 10,000 3 048.81 12,500 3 810.76 15,000 4 572.72 17,500 5 334.68 Table 4 Ambient Temperature Factor Ambient Temperature Factor 50 F/10 C 1.19 60 F/16 C 1.13 70 F/21 C 1.07 80 F/27 C 1.00 90 F/32 C.93 100 F/38 C.85 110 F/43 C.78 120 F/49 C.69 Factors for other ambient temperatures can be interpolated. Table 5 Pre Selected Pump & Cooler Assemblies for Falk Type ABX and ABX Gear Drives Only DRIVE SIZE Pre-Selected Pump & Cooler Assembly 405 210PA 425 210PA 445 220PA 465 220PA 485 220PA 505 230PA 535 230PA 555 230PA When Pump & Cooler Assemblies are specified, Pre-Selected sizes provide the required flow of oil. Do not use a larger or smaller size than is Pre-Selected. In the event the Pre-Selected size does not have adequate thermal capacity for the specific application, a special design Pump and Cooler Assembly, with oversize heat exchanger, is necessary. Contact Rexnord for price and delivery of special design Pump & Cooler Assemblies. 4 (131-315) Rexnord Industries, LLC, 2002.

Type PA Pump & Cooler Assemblies Sizes 205PA, 230PA, 240PA, & 250PA Dimensions Inches OIL DISCHARGE AIR FLOW 4-HOLES FOR FOUNDATION BOLTS A Drawings and dimensions are for reference and concept only. Certified drawings are furnished after receipt of purchase order with complete information. B VENT CL OF FAN & MOTOR H FAN ROTATION DIRECTION OF SHAFT ROTATION DRAIN G OIL SUCTION OPTIONAL DRAIN SIZE A B G H Weight-lb 205PA 34.75 27.75 0.50 41.00 285 230PA 36.50 36.50 0.50 46.75 567 240PA 37.50 43.50 0.50 54.00 690 250PA 37.50 49.50 0.50 61.00 945 Sizes 210PA 220PA Dimensions Inches 4-HOLES FOR FOUNDATION BOLTS AIR FLOW A Drawings and dimensions are for reference and concept only. Certified drawings are furnished after receipt of purchase order with complete information. VENT B OIL DISCHARGE H FAN ROTATION CL OF FAN & MOTOR DIRECTION OF SHAFT ROTATION DRAIN G OIL SUCTION OPTIONAL DRAIN SIZE A B G H Weight-lb 210PA 30.50 30.50 0.50 40.25 305 220PA 30.50 30.50 0.50 40.25 365 Rexnord Industries, LLC, 2002. (131-315) 5

This Page Intentionally Left Blank 6 (131-315) Rexnord Industries, LLC, 2002.

This Page Intentionally Left Blank Rexnord Industries, LLC, 2002. (131-315) 7

World Class Customer Service For more than 100 years, the dedicated people of Rexnord have delivered excellence in quality and service to our customers around the globe. Rexnord is a trusted name when it comes to providing skillfully engineered products that improve productivity and efficiency for industrial applications worldwide. We are committed to exceeding customer expectations in every area of our business: product design, application engineering, operations, and customer service. Because of our customer focus, we are able to thoroughly understand the needs of your business and have the resources available to work closely with you to reduce maintenance costs, eliminate redundant inventories and prevent equipment down time. Rexnord represents the most comprehensive portfolio of power transmission and conveying components in the world with the brands you know and trust. Rexnord, Renew, and Steelflex are registered trademarks of Rexnord Industries, LLC. Falk and Drive One are trademarks of Rexnord. All rights reserved. Rexnord Industries, LLC, Geared Products, 3001 West Canal Street, Milwaukee, WI 53208-4200 USA Phone: 866-REXNORD/866-793-6673 Fax: 414-643-3366 2006 Rexnord Industries LLC 131-315 11/2002 Delzer Litho Printed in USA