GEBOUDIENSTE 112 /BUILDING SERVICES 112 VRAAG 1 / QUESTION 1 [8]

Similar documents

Vermenigvuldig en Afdeling (Intermediêre fase)

UNIVERSITEIT VAN PRETORIA / UNIVERSITY OF PRETORIA DEPT WISKUNDE EN TOEGEPASTE WISKUNDE DEPT OF MATHEMATICS AND APPLIED MATHEMATICS

Soil and waste for high-rise

Department of Mathematics and Applied Mathematics Departement Wiskunde en Toegepaste Wiskunde

Die vrae uit ou vraestelle, toetsvraestelle, en modelvraestelle is individueel gekies en uitgehaal vir

Residential Plumbing BCN 1058

Department of Mathematics and Applied Mathematics Departement Wiskunde en Toegepaste Wiskunde

Heating and Domestic Hot Water Systems for dwellings Achieving compliance with Part L 2008

DRAIN, WASTE AND VENT PLUMBING

IMPLEMENTING AN EFFECTIVE INFORMATION SECURITY AWARENESS PROGRAM

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Policy on Student Leadership Development and Training

CONTENTS 1 INTRODUCTION 2 POSSIBLE INSTALLATION DIFFICULTIES 3 OUTLINE OF THE ASSESSMENT PROCEDURE 4 PURPOSE OF THE ASSESSMENT PROCEDURE

ALL YOU NEED TO KNOW...

Prepare a drainage system layout and specification notes for a low- rise building.

MARKETING MANAGEMENT

1 Discuss with brief notes and diagrams, the radiological management of

Why Do I Have Sewer Smells In My Home or Business?

Creating a GIS data model for IT infrastructure management - A pilot project at the Potchefstroom campus of the North-West University.

Compliance Document for New Zealand Building Code Clause G13 Foul Water Second Edition

THE SUPREME COURT OF APPEAL REPUBLIC OF SOUTH AFRICA JUDGMENT. SILTEK HOLDINGS (PTY) LTD (in liquidation) t/a WORKGROUP

Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References

COPYRIGHT AND CITATION CONSIDERATIONS FOR THIS THESIS/ DISSERTATION

Job Ready Assessment Blueprint. Plumbing. Test Code: 3061 / Version: 01

NATIONAL SENIOR CERTIFICATE GRADE/GRAAD 12

FAMILY PLAY THERAPY IN THE CONTEXT OF CHILD SEXUAL ABUSE: AN ECOLOGICAL AND GESTALT FIELD APPROACH MODEL

Servikale kanker is die tweede mees algemene kanker onder Suid-Afrikaanse vroue

PLUMBING SYSTEM DESIGN

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Advertising and attorneys: some anxiety -reducing empirical findings

Geberit Sovent. Installation Guide

Guernsey Technical Standard

REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

GMP-Z Annex 15: Kwalificatie en validatie

Maximizer Synergy. BE Houwaartstraat 200/1 BE 3270 Scherpenheuvel. Tel: Fax:

PMA ONLINE TRAINING Venting for Plumbing Systems

IN THE HIGH COURT OF SOUTH AFRICA (NORTH WEST DIVISION, MAHIKENG) JACOBUS WILLEM ADRIAAN NELL FRANZALL INSURANCE BROKERS CC JUDGMENT

The purpose of this chapter is to set forth provisions for planning, design and installation of waste disposal systems in and out of buildings

PRELIMINARY DETERMINATION IN TERMS OF SECTION 30J OF THE PENSION FUNDS ACT OF 1956

Plumbing Code in Commercial Kitchens

INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION. This guidance is endorsed by HHIC members.

Foul Drainage, systems and responsibility. Environmental Protection

Government Gazette REPUBLIC OF SOUTH AFRICA. AIDS HELPLINE: Prevention is the cure

HOëRSKOOL PORTERVILLE

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

ONLINE VERSION ONLINE VERSION

Hunter Plastics Ltd Nathan Way London SE28 0AE Tel: Fax:

Mechanical Services Standard Specification Above Ground Soil, Waste and Ventilation Pipes

NATIONAL SENIOR CERTIFICATE/ NASIONALE SENIOR SERTIFIKAAT GRADE/GRAAD 12 SEPTEMBER 2014 MATHEMATICS P1/WISKUNDE V1 MEMORANDUM

Oranje -Vrystaatse Gemeenskaplike Munisipale Pensioenfonds DETERMINATION IN TERMS OF SECTION 30M OF THE PENSION FUNDS ACT OF 1956

A Cost Comparison for the Supply and Installation of Three High Rise Sewer Stack Systems

PLUMBING ROUGH IN INSPECTION

Top 10+ Mistakes of DWV plumbing design

The Top Ten Most Commonly Asked Questions About VN T Vision Inspiration Navigation

IMPLEMENTATION AND ADVANTAGES OF A TOTAL QUALITY MANAGEMENT SYSTEM IN SERVICE RELATED INDUSTRIES

Constructive Dismissal and Resignation due to Work Stress

When Should Examination Preparation Begin?

How To Get A Bsc In Forensic Science

Drainage. Information for those with problem drains

Examen Software Engineering /09/2011

ANNEXURE TO ASSESSMENT INSTRUCTION 17 OF 2014 CHIEF MARKERS REPORT ON MARKING OF 2013 NATIONAL SENIOR CERTIFICATE EXAMINATION (NSC)

employager 1.0 design challenge

AANSOEK OM AANSTELLING AS KOMMlSSARlS VAN EDE APPLICATION FOR APPOINTMENT AS COMMISSIONER OF OATHS

CERTIFYING DRAINLAYER

Verticale tuin maken van een pallet

Innovasie deur diversiteit EN INLIGTINGSTELSELS

Drainage and waste disposal

BANDWIDTH EFFICIENT VIRTUAL CLASSROOM

Drainage and waste disposal

CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS

IN THE HIGH COURT OF SOUTH AFRICA (ORANGE FREE STATE PROVINCIAL DIVISION) Application No.: 3260/2001. In the matter between: and THE MAIZE BOARD

ONTARIO PLUMBING INSPECTORS ASSOCIATION INC. In the public service since Wet Venting. Incorporating Stack Venting and NPC Harmonization

Teacher Assessment Blueprint. Plumbing. Test Code: 5175 / Version: 01. Copyright 2010 NOCTI. All Rights Reserved.

12. Design of plumbing systems for single dwellings

CHAPTER 9 VENTS TRANSPORTATION OF SEWER GAS

What to Expect From the Examination. How to Study the Plumbing Codes

Submission on Basic Plumbing Repairs in Remote Aboriginal Communities from the Kimberley Aboriginal Health Planning Forum (KAHPF)

JACOBUS ADRIAAN RUPPING. Thesis presented in partial fulfilment of the requirements for the degree. MAcc (Taxation) of the

Benefits, business considerations and risks of big data

Opstel Assesseringsrubriek tot ½ tot tot 7. 7½ tot 8 4½ 4 3 2½ 2

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

GAUTENG DEPARTMENT OF EDUCATION ENGINEERING GRAPHICS AND DESIGN

An information technology governance framework for the public sector. by Judith Terblanche. Thesis presented in partial fulfilment of the requirements

THE NGK OFFICIALS PENSION FUND INTERIM RULING IN TERMS OF SECTION 30J OF THE PENSION FUNDS ACT OF 1956

EMPLOYEE PERCEPTION ON THE IMPLEMENTATION OF THE PERFORMANCE MANAGEMENT SYSTEM IN THE AMATOLA WATER BOARD EASTERN CAPE.

Looking after your Septic Tank System

Shopper Marketing Model: case Chocomel Hot. Eric van Blanken 20th October 2009

To many people, a home s plumbing system is perceived as being extremely

The Functional Design of a Project Management Information System: Case Study with South African Breweries Ltd

# 06 / 2014 Tel: /8150; Fax: , anton@ccmedia.co.za

Drainage and Grease Management for the Commercial Kitchen

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

STANDARD PLUMBING AND DRAINAGE REGULATION 2003

REGISTRATION EXAMINATION, NOVEMBER 2012 CERTIFYING PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Plumbing for retail food businesses

HOE WERKT CYBERCRIME EN WAT KAN JE ER TEGEN DOEN? Dave Maasland Managing Director ESET Nederland

IP-NBM. Copyright Capgemini All Rights Reserved

Transcription:

GEBOUDIENSTE 112 /BUILDING SERVICES 112 SEMESTER TEST 1 / SEMESTER TOETS 1 MEMO 2013 VRAAG 1 / QUESTION 1 [8] By means of ONE full sketch, describe in full the ways in which water traps can be destroyed other than evaporation and back pressure. Beskryf aan die hand van EEN volledige skets, die maniere waarop water slotte gebreek kan word, buiten verdamping en teendruk. 1

VRAAG 2 / QUESTION 2 [15] Discuss and sketch in full, what a sovent system is and when you will make use of it? What alternative to the use of this system can you suggest? Bespreek en illustreer volledig wat n belugter-stelsel is en wanneer jy een sal gebruik? Watter alternatief tot die gebruik van hierdie stelsel, sal jy voorstel? Dit is n enkel stampyp stelsel (1) waar die vloei kapasiteit van die stampyp verhoog word met n SPESIALE ONTLUGTER ONDERDEEL by die verbinding van sytakke met die stampyp (1) Dit laat ons toe om kleiner stampype te gebruik en elimineer addisionele stampyp ontlugter behoeftes (1) Die sy-takke is ontwerp om te werk sonder teenheuwelwerkende pype (1) Vorming van water-proppe in die stampyp vanaf sy-takke te voorkom (1) Dit vermeng die vuilwater vloei vanaf sy-tak met water/lug vloei reeds in stampyp (1) Beperk die vloei-druk of velocity van vloeistowwe en lug in die stampyp (1) Verseker die ontlugter aksie van sy-takke (1) Voorkom spatwater/skuim in sy-takke (1) Sovent -stampyp het goeie druk eienskappe (1) Sy-takke benodig goeie ontwerp om self-heuwelwerking te voorkom (1) 2

Die sovent -stelsel is voordelig as meer as 10 verdieping gebou is, a.g.v. die koste van die belugter onderdeel (1) Baie maklik as dieselfde uitleg herhaal word (1) It is a single stack system (1) where the flow capacity of the stack is increased by SPECIAL AERATOR FITTING at the junction of the branches with the stack. (1) Allows to use smaller stacks & eliminates suppl. stack venting needs (1) The branches designed to work without anti-siphonage pipes. (1) Prevent formation of a plug of water in the stack from the branch (1) Mixes the waste flow from branch with water/air flow in stack (1) Limits velocity of liquid & air in the stack (1) Ensures venting action of branches (1) Avoid splash water / foam in branches (1) Sovent stack has excellent pressure characteristics,(1) Branches NEEDS careful design, preventing self-siphonage (1) The sovent system is more advantageous > 10 storeys - due to cost of aerator fittings (1) Easy when the same layout is repeated (1) VRAAG 3 / QUESTION 3 [12] 3.1 Identify the pipe system as per the photo 3.2 Describe the system in full 3.3 Is this system still in use in industry today? 3.1 Identifiseer die pypstelsel soos op die foto 3.2 Beskryf die stelsel volledig 3.3 Word die stelsel vandag nog in die industrie gebruik? 3.1 Enkel-stam stelsel / Single stack [1] 3.2 Die Enkel Stampyp Stelsel = Een-pyp Stelsel maar sonder ontlugters vir elke toebehoor [1] Die individuele sperders is ongeventileerd + die 1 stampyp dien as beide hoof-afvoer en ontlugter component [1] Groot besparings in pypwerk + skag spasie + blootstelling & vermy estetiese onooglikheid [1] Word deur die Nasionale Bou Regulasies vir residensiële & kantoorgeboue toegelaat [1] Wanneer ontwerp limiete van die enkel stampyp sisteem oorskry word [1] 3

By residensiële eiendom, word elke individuele toebehoor direk verbind met stampyp met geen gemeenskaplike sy-tak pyp of teen-heuwelwerking pype nie [2] n Stampyp mag n addisionele ( supplementary ) ontlugter benodig met hoë geboue selfs op 2de vloer [1] Met kantoorblokke, word dieselfde toebehore gekoppel aan die stampyp d.m.v. n gemeenskaplike sy-tak pyp [1] Daar is beperkinge tot die hoeveelheid toebehore aan n gemeenskaplike sy-tak: Geen teen-heuwelwerking pype nie [1] n Addisionele ontlugter mag benodig word, afhangend van die aantal toebehore en die stampyp diameter [1] 3.2 The Single Stack System=One-Pipe System without vents. [1] The individual traps are unvented + the 1 stack serves as both main discharge and ventilating component. [1] Great Savings in Pipe Work + duct space + less exposed & unsightly [1] When design limits of single stack system exceeds, use onepipe system. [1] With residential, each ind. appl. Is directly connected to stack with no common branch pipes or anti-siphonage pipes. [2] The stack may require a supplementary vent at high rise buildings [1] With office buildings, appliances of the same type are connected to the stack via common branch pipe. [1] There are limitations to the # of appl.on common branch. - No anti-siphon pipes [1] Suppl stack vent may be required, depending on # of appl & stack diameter [1] 3.3 JA / YES [1] 4

VRAAG 4 / QUESTION 4 [15] It was thought that only drainage of water closets constitutes a health hazard. (1) They separated the soil and waste water in two-pipe system. (1) Upper floor soil appl. discharge into separate soil stack connected directly to underground drains. (1) Waste water appl discharge into separate waste stack, discharging to a trapped gully connected to underground drains. (1) The gully acts as a seal against odours rising from foul water drain into waste stack. (1) All traps are vented against siphonage (1) The stack may be provided with a relief vent, below the branch pipe to the lowest appl. (1) To relief back pressure at bend at the base of stack where it connects with horizontal underground pipe/drain. (1) Very expensive system (1) Sketch (6) 5

VRAAG 5 / QUESTION 5 [10] 5.1 A discharge stack carries liquid effluent and a vent stack carries air to ensure pressure fluctuations are minimised in the drainage system. (2) 5.2 The water seals have evaporated in the toilets. (2) If the gully seal had failed the smell would be outside. Flush the toilets and the water seals will be restored. (1) 5.3 Waste & Soil water (solids and fluids), be carried away, quickly, quietly, without blockage and without foul air escaping into the building. (3) 5.4 True (1) 5.5 False (1) TOTAAL 60 / TOTAL 60 6