Operating Instructions

Similar documents
Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Series 8146/5-V37 and Series 8150/5-V37

Instructions for Safe Use

Technical Data. Dimensions

Explosion proof enclosures

Terminal Boxes Series 8146

Technical Data. Dimensions

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6402/2

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Operating Instructions

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Plug and Socket Devices CES 63 A Series 8579

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Operating Instructions

MINI MCR-SL-R-UI(-SP)

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Compact pressure switch Flameproof enclosure Ex d Model PCA

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Modular I/O System Analog and Digital Interface Modules

Instruction Manual Differential Pressure Transmitter

FGM 160 ATEX EC type examination certificate

Redundancy Module QUINT-DIODE/40

Inductive sensor NI10-M18-Y1X-H1141

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Floodlight Range Installation Guide

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Accessories SUNNY REMOTE CONTROL

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

A good connection. International approvals.

Plug and Socket Devices SolConeX 16 A Series 8570

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

ADM1TE 5/30A DIN rail single phase two wire energy meter

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

MIC-WKT and MIC-WKT-IR

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

TX OPEN RS232/485 module

HP UPS R1500 Generation 3

Inductive slot sensor

HERZ-Thermal Actuators

UM-X Field display for continous level sensors

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

M3 ORANGE Snap-On. User Guide. Product Model: A-SNO-ATYP-060-R00. Compatible Device: M3 ORANGE. Version 2.2 Released in March 2013

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Safety instructions VEGADIS DIS81.CEIA/V****

Operating Instructions

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

CONFIGURABLE SAFETY RELAYS

Operating Instructions. Room temperature controller

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Flameproof Audible Signal 115 db (A) Series YA90

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd.

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Digital input modules

Design of intrinsically safe systems

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

SEISMIC VELOCITY TRANSDUCER T1-40

Technical data sheet TDS0070

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ACS-30-EU-EMDR-10-MOD

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

aseries A13B Mini Bullet Camera User Manual

GREISINGER electronic GmbH

Radiant Temperature Sensor TY7321

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

=============================== WARNING

SMS 4 / SMS 5 safety mat Product information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Addendum to the Operating Instructions

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

ITEM MODEL QTY. Filter ITEM MODEL QTY USB-RS485 Converter (with 3716A-21) 3716A-20 1

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Solenoid Valve Island Type 3965

Antenna Splitter ASA 1. Instruction manual

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

English. User Manual. POLARIS Web Client/Remote PC 17-71V3-...

T7560A,B,C Digital Wall Module

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

8146/5 Series Breaker Panelboards

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Sunny Boy Accessories SMA POWER BALANCER

Control and Distribution Boxes made of Stainless Steel Series 8150

Transcription:

Operating Instructions Power supply module iscanps Revision date: 21.3.2016 Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 1

Contents 1. iscanps product range overview... 3 2. Important notes on the operating instructions... 4 2.1 Safety information... 4 2.2 Notes on the operating instructions... 4 2.3 General notes of caution... 5 3. Product Information... 7 3.1 Manufacturer... 7 3.2 Certification... 7 3.3 Serial numbers... 7 3.4 Technical data... 8 3.5 Type numbers... 10 4 Operating the power supply module... 11 4.1 Power supply design... 11 4.2 Pin assignment in the Ex e connection box... 12 4.3 Pin assignment in the Ex i connection box with RS232 interface... 13 4.4 Pin assignment in the Ex i connection box with RS232 interface... 14 Revision control Document Number 416239, revision 2.0 This document is copyright 2016. Extronics reserve the right to change this document and its content without notice. The latest version applies. Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 2

1. iscanps product range overview Power supply module Standard 1D iscan211 Standard and stacked PDF iscan211pdf Standard 1D, stacked PDF, and 2D ISCAN2012D Standard 1D iscan101 Standard and stacked PDF iscan101pdf Standard 1D, stacked PDF, and 2D ISCAN1012D iscan101cab1 iscan211exb iscan201exb2d iscan101cab2 iscan101cab3 iscan101cab4 iscan101cab5 iscan101cab6 iscan101cab1 iscan101cab2 iscan101cab5 iscan101cab6 iscan2xxcab5 iscan2xxcab6 iscan2xxcab7 iscan2xxcab8 iscan2xxcab9 iscan2xxcab10 iscan2xxcab5 iscan2xxcab6 iscan2xxcab7 iscan2xxcab8 iscan2xxcab9 iscan2xxcab10 iscanps1 iscanps2 iscanps3 iscanps4 iscanps12d iscanps32d iscanps1 iscanps2 iscanps3 iscanps4 iscanps1 iscanps2 iscanps3 iscanps4 Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 3

2. Important notes on the operating instructions 2.1 Safety information Warnings are highlighted by a special symbol and a different font colour: Danger Non-compliance may result in life-threatening situations. This warning must be heeded. This type of warning concerns dangerous situations that may result in minor injuries. Warning Info Important and helpful notes and information. 2.2 Notes on the operating instructions Before starting up the equipment please read the Manual thoroughly. The Operating Instructions contain important information on functionality as well as safety rules. If these are not heeded, normal operations within hazardous areas cannot be guaranteed. The notes contained in this manual are important for starting up and operating the product. These instructions may be updated at any time. reserves the right to make changes to this document. Before they use the product, users must ensure that they have the most up-todate version of the operating instructions. To make sure this is the case, please check Extronics website, www.extronics.com, or contact one of the company's staff. The drawings contained in these operating instructions are for illustration purposes only and may differ somewhat from the actual design. No changes may be made to the device that were not intended or approved by. Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 4

If the handheld scanner is not used properly, the operating permission for hazardous areas may lapse for the device in question. Non-adherence to the instructions will void any warranty. For the full commission of the handheld scanner, the programming information contained in the manual issued by SICK AG (www.sick.com) is also required. 2.3 General notes of caution Caution / Notes The devices may only be operated when fully assembled. In hazardous areas, the devices must not be wiped or cleaned with a dry cloth. The device must be switched off immediately if it is likely that it can no longer be operated safely as a result of damaging impact or general peculiarities (such as ingress of water or other fluids, temperatures outside of the specified range, etc.). General statutory requirements or health and safety rules and accident prevention guidelines and environmental laws must be adhered to (e.g. the German Occupational Health and Safety regulation). Users must not open the device. Users must not make any changes to the device. Components may not be exchanged or replaced. If non-specified components are used, explosion protection is no longer guaranteed. Ensure safe handling with firm footing and sufficient room for movement. If the enclosure is in any way damaged the device must be removed from the hazardous area immediately. In accordance with IEC 60079-19 and IEC 60079-17, operators of electrical installation in hazardous areas are obliged to have them serviced by qualified electricians. Do not insert any sharp objects into the enclosure or any other openings of the handheld barcode scanner. Any openings at the device may not be covered or blocked. The device and any accessories must be properly disposed of, i.e. as legally specified, for example by a certified company. Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 5

Notes on installation Electrical plants are subject to certain regulations concerning installation and operation (e.g. RL 99/92/EG, RL 94/9EG, or the national rules such as IEC 60 079-14 and VDE 0100). In the hazardous area it is the operator's responsibility to carry out any repair and maintenance in compliance with applicable rules. Caution on laser devices Devices fitted with laser fall under standards US 21 CFR 1040.10 and EN 60825-1. The laser's classification is stated on a plate affixed to the device. Class 1 lasers are deemed inherently safe during normal use, but users must not look directly into the light source. The following declaration is required by American and international laws: Usage of control elements, adaptations or the use of procedures that differ from these instructions may result in a dangerous exposure to laser beams. Class 2 lasers use a visible low-voltage LED. As with any source of bright light, such as the sun, the user should avoid looking directly into the light. Brief exposure to a class 2 laser is deemed not dangerous. Maintenance Provided the device is operated and assembled according to instructions and the ambient requirements are being met continuous maintenance is not necessary. Servicing Operators of electric equipment in hazardous areas are obliged to have them serviced by qualified electricians (IEC 60079-19 and IEC 60079-17). Repairs Repairs may only be carried out by the manufacturer or by persons trained and commissioned for this purpose by the manufacturer. The device is closed ex-factory. It may only be opened in the factory by specifically trained personnel. Software installation Operation For instructions on how to install the software at the PC please refer to the manual issued by SICK. Before operating the device you must ensure that all necessary components are available. Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 6

3. Product Information 3.1 Manufacturer 1 Dalton Way Midpoint 18 Middlewich CW10 0HU 3.2 Certification iscanpsx: Test certificate II 2 G Ex eb qb [ib IIC/IIB] IIC T4 II 2 D Ex tb [ib] IIIC T135 C II 2 G Ex e q [ib IIC/IIB] IIC T4 Gb II 2 D Ex tb [ib] IIIC T135 C Db IBExU15ATEX1082 IECEx IBE 15.0022 Protection rating IP65 3.3 Serial numbers Serial key: Year of manufacture (2 numbers) Serial number (4 numbers) Example: 16001 Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 7

3.4 Technical data Non-intrinsically safe iscanps1 and 2: power supply circuit: rated voltage Un DC +12 V ± 10 % power input P = ca. 3.3W (max. 6.6W) iscanps3 and 4: rated voltage Un AC 90 V to 253 V, 50-60 Hz power input P = ca. 4W (max. 16W) Non-intrinsically safe data circuit: RS232 RS422 USB ±12 V / 4 ma +12 V / -7 V / 4 ma +5 V / 68 ma Nominal data (RS232): iscanps1 and 3 (RS232 interface, output current 240mA): maximum fault voltage Um 253V maximum output voltage Uo 4.9V maximum output current Io 440mA maximum output power Po 1.25W (trapezoidal characteristic) maximum external capacitance Co 113 µf maximum internal capacitance Ci 2.2 µf maximum external inductance Lo 0.1mH iscanps12d and 32D (RS232 interface, output current 420mA): maximum fault voltage Um 253V maximum output voltage Uo 4.9V maximum output current Io 750mA maximum output power Po 2.01W (trapezoidal characteristic) maximum external capacitance Co Ex ib IIC : 113 µf (Lo=0) Ex ib IIB : 250 µf (Lo=0) maximum internal capacitance Ci 2.2 µf maximum external inductance Lo 0.1mH (Co=0) Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 8

Nominal data (USB), intrinsically safe supply circuit: maximum output voltage Uo 4.9V maximum output current Io 440mA maximum output power Po 1.20W (trapezoidal characteristic) maximum external capacitance Co C o VCC + C o DATA =113 µf maximum internal capacitance Ci 2.2 µf maximum external inductance Lo 0.1mH Nominal data (USB), intrinsically safe data circuit: maximum output voltage U O maximum output current I O D+/D- D+/D- maximum output power P O 4.9V 40mA 48W (linear characteristic) D+/D- maximum external capacitance Co Ex ib IIC : 113 µf (Lo=0) Ex ib IIB : 250 µf (Lo=0) maximum internal capacitance Ci 1.2 µf maximum external inductance Lo 0.1mH (Co=0) Pin assignment data circuit, non-intrinsically safe data circuit: RS232 RS422 X5 (TxD) X4 (GND) X7 (T+) RS232 ± 12V / 4mA RS422 ± 12V / -7V / 4mA X8 (T-) X6 (TE) USB X5 (screen) USB +5V / 68 ma X4 (GND) X6 (NV) X7 (D+ 2MA) X8 (D- 2MA) Pin assignment data circuit, non-intrinsically safe data circuit: RS232 USB X9 (RxD) X10 (GND) X9 (D+ 2SL) U i = 5.5V DC U O D+/ D- = 4.9 V X10 (D- 2SL) I O D+/ D- = 20 ma per data cable X11 (GND/PE) P O D+/ D- = 24 mw per data cable linear characteristic Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 9

External connection cable: Data cable : USB: 2.0 2.5 mm 2, 4-wire RS232: 0.2 2.5 mm 2 3-wire Power supply cable : USB: 0.2 2.5 mm 2, 3-wire The current rating of the connection cables must be checked before use. Dimensions: 140 mm x 250 mm x 56 mm (W x H x D) Weight: Ambient temperature: 3.1 kg without connection cable -25 C to +60 C 3.5 Type numbers RS232 devices iscanps1 iscanps1 2D DC 24 V with RS232 interface, U a = 4.9 V / I a=240 ma DC 24 V with RS232 interface, U a = 4.9 V / I a=420 ma iscanps3 iscanps3 2D AC 90 to 253 V with RS232 interface, U a = 4.9 V / I a=240 ma AC 90 to 253 V with RS232 interface, U a = 4.9 V / I a=420 ma USB devices iscanps2 DC 24 V with USB interface, U a = 4.9 V / I a=240 ma iscanps4 AC 90 up to 253 V with USB interface, U a = 4.9 V / I a=240 ma Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 10

4 Operating the power supply module 4.1 Power supply design Use the four fixing holes at the corner of the base plate (see diagram) to mount the power supply onto a firm surface. The holes have a diameter of 7mm each. The equipotential bonding connection (M 5 x 10) is located at the front and back of the power supply. Equipotential bonding is required for the entire installation of the intrinsically safe circuits. Terminal connection box underneath cover. Cable gland M16 x 1.5 for appliance. Cable gland M16 x 1.5 for data transfer. Cable gland M20 x 1.5 for voltage supply. Ex e connection box for connection of voltage supply. Ex i connection box for connection of appliances. Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 11

4.2 Pin assignment in the Ex e connection box Pin assignment for the supply with RS232 interface: Terminal definition Terminal number Description Type numbers + / - L X1 - / N X2 PE X3 PE GND X4 RS232 TxD X5 RS232 L = AC 100 V to 250 V + = DC24 V N Neutral conductor - minus Shield X6 RS232/RS422 T+ X7 RS422 T- X8 RS422 iscanps1 iscanps12d iscanps3 iscanps32d iscanps1 iscanps12d iscanps3 iscanps32d Pin assignment of supply with USB interface: Terminal definition Terminal number Description Type numbers + / - L X1 - / N X2 PE X3 PE GND X4 USB Shield X5 USB NC X6 D+ X7 USB D- X8 USB L = AC 100 V to 250 V + = DC24 V N Neutral conductor - minus iscanps2 iscanps4 iscanps2 iscanps4 Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 12

4.3 Pin assignment in the Ex i connection box with RS232 interface The terminal assignment is located underneath the removable cover at the front of the power supply. Caution! Do not open enclosure in hazardous area! Before operating the device in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tightened. Any changes to the wiring may only be carried out by trained staff. Pin assignment in the Ex i connection box RS232: Power supply Type: iscanps1, 12D, 3, 32D Prepared Connection coupling Connection box Pin Wire Definition Number 3 3 RxD X9 GND PE X10 X11 2 2 GND X12 1 1 +UB X13 Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 13

4.4 Pin assignment in the Ex i connection box with RS232 interface The terminal assignment is located underneath the removable cover at the front of the power supply. Caution! Do not open enclosure in hazardous area! Before operating the device in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tightened. Any changes to the wiring may only be carried out by trained staff. Pin assignment in the Ex i connection box USB: Power supply Type: iscanps2, 4 Prepared Connection coupling Connection box Pin Wire Definition Number 3 3 D+ X9 2 4 D- X10 PE X11 4 2 GND X12 1 1 +UB X13 Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E-mail: info@extronics.com Web: www.extronics.com 14