SAUTER EY3600. Compatibility, comfort and energy efficiency at all levels of building automation.

Similar documents
SAUTER novapro Open: B-AWS. BACnet Advanced Workstation

SAUTER EY-modulo 5. The complete building management solution

YZP : SAUTER Vision Center

System description EY-modulo A A

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

Integrated Building Management and Security System. Building Automation & Security.

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

OPENweb. Efficient controlling at the highest level.

Climate Ready Control Systems Technical Specifications

Supporting ANY PRODUCT employing

Understanding Device Level Connection Topologies

Integrated Building Management and Security System. Building Automation & Security.

PLCs and SCADA Systems

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Efficient remote access to machines and plants with SIMATIC

Climate Ready Shade Operating Systems for residential applications.

Technology Spotlight on Cellular Data Networking for SCADA system networks. Presented by Teamwork Solutions, Inc.

Your remote sites at your fingertips?

System Development and Life-Cycle Management (SDLCM) Methodology

Digi Connect WAN Application Guide Using the Digi Connect WAN and Digi Connect VPN with a Wireless Router/Access Point

Personna PC web-based software. Q-AdminTM client. Lighting management hub (floor 2) Lighting management hub (floor 1)

MM8000 safety and security with smart danger management. A scalable and flexible management station for any requirement. Answers for infrastructure.

Chapter-5 Introduction to Building Automation System (BAS)

1 Application Description Objective Goals... 3

Using installed Fieldbus Wiring to carry Ethernet Communications

MY HOME - CONTROL 130

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

ControlMaestro and. BACnet integrated solution

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

Network Topology Comparison

Discovering Computers Chapter 9 Communications and Networks

Newron Efficient building management

Intelligent Integrated Systems

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

EUCIP - IT Administrator. Module 3 LAN and Network Services. Version 2.0

Introduction To SCADA and Telemetry

IntesisBox. Making Building Automation go further. Modbus Products

Bluetooth Web Enabler

Understanding Device Level Connection Topologies

Automation Unit TM 1703 ACP Flexible automation and telecontrol

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Agenda Introduction to KNX UK What is KNX? KNX the all round advantages The Standards Manufacturers & Products KNX Technology Applications KNX is

DL TC72 Communication Protocols: HDLC, SDLC, X.25, Frame Relay, ATM

It s all open from here.

Personna PC web-based software. Q-AdminTM client. Lighting management hub (floor 1)

HELPING BUILDINGS THINK

SCADA Questions and Answers

Square D Model 6 Motor Control Centers

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

ABB PSPS Erich Steinmann; Generator control-2013

Future Stars. Grade X Manual Chapter 1 Networking and Telecommunication. telecommunication. Telephones, telegrams, radios and televisions help

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

PCS0100en Persy Control Services B.V. Netherlands

Solution for the integration of the security systems in the global building automation system

Network Design. Yiannos Mylonas

Introduction to Computer Networks and Data Communications

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

PowerCommand iwatch 100 Remote Network Monitoring

TX2123 RS485 TO ETHERNET ADAPTOR

Permissible ambient temperature Operation Storage, transport

This course has been retired. View the schedule of current <a href=

Introduction to PROFIBUS and PROFINET

IBMS Specification. Specification & Design Guideline for Integrated Intelligent Building Management System. Lonix Ltd.

INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME. Ján Cigánek, Martin Janáček, Stanislav Števo

AutoLog ControlMan. Remote Monitoring & Controlling Service

Networks. The two main network types are: Peer networks

PROFIBUS AND MODBUS: A COMPARISON

Telecommunications, Networks, and Wireless Computing

savic-net for Integrated Building Management System

Modbus and ION Technology

NETWORKING TECHNOLOGIES

Documentation. M-Bus 130-mbx

Forum 500 telephone exchange. a professional telephone welcome for all your customers

Developing Wireless GPIB Test Systems Using the GPIB-ENET/100

SCADA System Fundamentals

MM8000 highest safety and security with intelligent danger management

IntesisBox Modbus Server Fidelio IP

Electric Measurement and Control. Energy management software

Internet-Accessible Power Monitoring & Control Systems

connecdim Gateway G1 Ethernet TCP/IP to DALI

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

Application Note #563 Revision A November 2015 Lutron / Automated Logic BACnet Integration

LB Sky Global. 92 Lobachevskogo St, Bld 92, Office 5, Moscow, Russia Tel/Fax 7(495) , Site:

SCADAvantage Network Topology System software products

Integrated Controls & Monitoring System for Apartments. Solution for southern countries.

Natural Gas Well Automation using Kingfisher RTU Products

AUTOMATIONWORX. Seamless system technology from the remote control station to the control center

Impact of Power-over-Ethernet (PoE) on Industrial-based Networking

Intelligent Terminal Automation System

Security systems Fire alarm systems Access control systems Perimeters Video systems Other specific devices Production processes

Mathatma Gandhi University

DCM. Product Brochure. Diagnostic Communication Master

Sensor Devices and Sensor Network Applications for the Smart Grid/Smart Cities. Dr. William Kao

SPPA-T3000 Control System The Benchmark in Controls

JOB READY ASSESSMENT BLUEPRINT COMPUTER NETWORKING FUNDAMENTALS - PILOT. Test Code: 4514 Version: 01

Home Passport Gateway Series Simplify your Life with Smart Solutions

Information. Communication for the open minded. Siemens Enterprise Communications

Transcription:

SAUTER EY3600. Compatibility, comfort and energy efficiency at all levels of building automation.

The world of EY3600 The Integrated Building Management System. Printer Pager E-mail SMS Camera Laptop Laptop CAFM Fax Router Access Point VPN DSL Router Voice message ISDN Server AAM (Advanced Alarm Management) M-Bus novanet Ethernet TCP/IP Window blinds Wireless Smoke detector Ethernet BACnet/IP Web server Lighting Printer LON BACnet Gateway EIB novanet Field bus Profibus DP LON 2

From the very outset, Sauter and the EY3600 building management system will guarantee you unrestricted vertical and horizontal integration. You are free to choose the network communication so that complex tasks become easily manageable. Weather data and forecast Hotel booking system Fire-alarm system Security system Access-control system Smart Phone Wireless-LAN Access Point Operation via web browser Printer BMS workstation Administration & maintenance Energy management PDM (Process Data Manager) Laptop Laptop MDA novanet Wireless OPC Server Client LON Field bus Profibus Bluetooth DSL Router novaweb Router LON Protocol 3964R EIB Modbus RTU Universal gateway novacom / EIB Profibus Modbus-RTU Topology for universal integration The EY3600 building management system is fully scalable, making it an intelligent basis for integrated networks. When equipped with the novapro Open software, the EY3600 links the vertical integration of the field, automation and management levels with the horizontal integration of various systems. This approach opens up limitless possibilities for expanding systems and connecting to the web. Scalability means that you can start out small with EY3600 novapro Open, and then expand the system to any size you want. Protocol 3964R 3

BACnet/IP on Ethernet Communication as you choose, for all levels. SAUTER products fulfil the BACnet standard The BACnet standard has become established for communication between automation stations and with the management level via Ethernet. BACnet was devised by ASHRAE (American Society of Heating, Refrigerating and Airconditioning Engineers), and is now the first global standard for communication in building management systems (ISO/DIS 16484-5). The products also provide: Event-orientated communication for changes to measured values and statuses BACnet server and BACnet client functionality Support for all commonly-used BACnet objects, including time programs and calendar objects BACnet Sauter s BACnet automation stations can be expanded to a capacity of 1000 BACnet objects thanks to decentralised modules with intrinsic intelligence. M M M 4

Operating panel, touch-panel, PC operating software or web browser. Decentralised operation as requirements demand Building management based on EY3600 allows you to monitor and change process values and statuses at any point in the automation network. A varied range of possibilities for decentralised operation is available to match the configuration and requirements of the installation. The EY3600 modu240 control panel, directly connected to an automation station, offers the information and the possibilities for intervention that you want on the spot. The EY3600 modu250 touch-panel makes all the information available at any point in the automation network, in table form or with complete graphics in colour. Equally, one or more PCs with the novapro Open system operating software can be connected at any point in the novanet. The user interface meets all the needs for modern visualisation: Dynamic address list Plant diagrams in bitmap or vector format Alarm output via a variety of communication devices Pre-configured protocols Central management of decentralised time profiles and calendars Convenient presentation of HDB and trend data Individual password protection, finely graduated Web server for operation via internet browser Placed directly onto the CASE project data with minimal labour requirement Flexibility due to a wide range of combinations The data in the novapro Open web server can be accessed via a standard web browser from any PC, without the need for special software. This enables operation, remote monitoring and remote maintenance via LAN, WAN, the intranet or the internet. Depending on the desired operating philosophy for room-temperature setpoints, shade and lighting, the web browser can even replace conventional room control units. 5

EY3600 novanet and EY3600 novacom Perfect communication and external integration in automation networks. SAUTER EY3600 novanet: specially developed for building automation Its structure complies with the OSI layer model, which is an international standard. Communication participants may include automation stations, unitary controllers or PCs. The highly efficient novanet protocol permits the use of simple, inexpensive architecture even for large networks. 6

EY3600 novanet offers these special features: Real peer-to-peer/multi-peer cross-communication Event-orientated data transfer Short response times Free topology (line, ring, or tree structure) Freely extensible by using novanet repeaters Up to 28,672 automation stations and 256 PCs can be addressed in one network Several novanet networks can be coupled together Any distances can be bridged using novanet routers via standard modems, ISDN adaptors etc., with demand-led connection and disconnection Standardised driver interface with the novanet OPC server for any SCADA software Profibus / EIB Modbus-RTU Protokoll 3964R Profibus / EIB Modbus-RTU Protokoll 3964R The EY3600 novacom universal interface enables decentralised data exchange with sub-systems at the automation level. Because it is freely programmable, it is possible to create direct functional links with the subsystems. These are just some of the systems that are supported: LON EIB M-Bus Modbus RTU SAUTER EY2400 Simatic control systems Alarm systems, e.g. Securiton, Cerberus Fire-protection systems, e.g. Esser Air-conditioning equipment, e.g. Toshiba Lighting-control systems, e.g. Zumtobel Luxmate Pump-management systems, e.g. Grundfos, Wilo Frequency converters, e.g. Danfoss VLT 7

Many integrated functions in SAUTER automation stations EY3600 nova automation stations consistently put the concept of distributed intelligence into practice. The stations are freely programmable, allowing decentralised, autonomous operation for individual control. Alongside extensive regulation, control and logic functions, the automation stations also feature a time and calendar function and a local historical database. Information affecting several areas is exchanged independently in cross-traffic. For example, energy management for peak load limitation is fully integrated into the system. 8

EY3600 automation stations: distributed intelligence consistently implemented. User-friendly operation The integrated lightning protection and the sturdy design guarantee high noise immunity and reliable operation. The same high-performance microprocessor is used in all the stations. Communication is carried out via BACnet or novanet. The user-friendly CASE Suite enables the stations to be programmed graphically using firmware modules that contain Sauter s extensive knowledge of installations. To meet the task in hand, all that s left to do is to select and connect the most suitable modules. The user can make program changes on his own, even if he has little prior knowledge of the system. Specifications nova220 nova225 nova230 nova106 (EYU109) Dimensions (W x H x D in mm) 280 x 266 x 78 280 x 266 x 78 280 x 266 x 78 267 x 482 x 180 LED indication (novalink) Labelling possible (novalink) Power supply 230 V~/24 V~, 50/60 Hz 230 V~/24 V~, 50/60 Hz 230 V~/24 V~, 50/60 Hz 230 V~, 50/60 Hz Emergency power 12 V (external) 12 V (external) 12 V (external) Pb battery 12 V/6 Ah Digital inputs 32 64 (novalink) 16 Range of cards or novalink Meter inputs 2 2 2 Range of cards or novalink Analogue inputs Ni/Pt1000 6 x U/I/R Ni/Pt1000 8 x U/I/R Digital outputs 4 x 0-I/4 x 0-I-II 16x0-I/16xI-II (novalink) Ni/Pt1000 4 x U/I/R Range of cards or novalink 1 x 0-I/3 x 0-I-II Range of cards or novalink Rating 250 V~/2 A 250 V~/2 A 250 V~/2 A 42 V /2 A (novalink 250 V~ /2 A) Analogue outputs 6 x 0 10 V (2 x 0 20 ma) 12 x 0...10 V (novalink) (6 x 0...20 ma) 3 x 0 10 V (1 x 0 20 ma) Range of cards or novalink novalink field modules novaflex I/O modules Printer interface Local operation 9

The EY3600 I/O modules: decentralised intelligence and manual/emergency operation on site. Independent operation of field modules and automation stations Selected automation stations allow the control of field modules which function as intelligent terminals, substantially cutting the labour required for installation. Supplemented with the added manual operating function, they are fitted either in the cabinets or in the technical system direct. The modules can be run independently of the automation station, so they meet the requirements for an emergency operating level. The connection between the automation stations and the field modules uses a twisted two-wire cable which can cover a distance of up to 100 metres. Specifications modulink164 modulink165 modulink170 modulink174 Functions Issues switching commands 0 I Issues switching commands 0 I II Issues positioning signals Records digital inputs Dimensions (W x H x D in mm) 105 x 90 x 54 105 x 90 x 54 105 x 90 x 54 105 x 90 x 54 Number of inputs/outputs 4 2 4 x 0...10 V 2 x 0...10 V/2 x 0...20 ma Rating/output signal 250 V~, 2 A 250 V~, 2 A 0 10 V/0 20 ma Manual operation Emergency operation LED/indicator (green) (green) potentiometer setting 16 (red/green) Labelling possible Priority circuit/watchdog Connection to nova106 Connection to 225 Distance AS to field module 100 m (5 nf/3 Ω) 100 m (5 nf/3 Ω) 100 m (5 nf/3 Ω) 100 m (5 nf/3 Ω) 10

11

Systems Components Services Facility Management 70010230003 X6 www.sauter-controls.com Subject to modifications. 2010 Fr. Sauter AG