Differential Pressure Transmitter STK337

Similar documents
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Technical Information RIA14

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Pressure transmitter For general industrial applications Model A-10

PRODUCT PROFILE FEATURES

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Flow switches Series AD/VH

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Digital inductive conductivity transmitter

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

How To Use A Ds340 (Dsp)

Differential Pressure Transmitter Model DPT-10

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Data Sheet PS1B Pressure Switch

Plastic tube flowmeters Series PT/PS

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Electronic Pressure Switch EDS 3000

How To Use A Flowmeter

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

PIEZOMETER AIRFLOW MEASURING RING

Rosemount 333 HART Tri-Loop

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Instruction Manual. T3111 T3111L T3111P T3111Ex

Series DFMT Digital Paddlewheel Flowmeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

J TB/TW Temperature limiter, temperature monitor

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Rosemount 333 HART Tri-Loop

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Variable V Area Flowmeter Rotameter The Original

HYDRUS ULTRASONIC METER

T0118 T2118 T3118. Instruction Manual

T U R B I N E G A S M E T E R

Compact pressure switch Flameproof enclosure Ex d Model PCA

How To Make A Smart Transmitter

Duct Humidity Transmitter

Cable Plug acc. to DIN EN , Form A

Preset Counter signo 721

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Thyristor-controlled power supplies and battery chargers

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Electric Rotary Actuator - On/Off or programmable control actuator

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

IFC 070 Technical Datasheet

Operation Manual For NDJ-8S Digital Rotary Viscometer

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Model 43AP Pneumatic Controller, Style B

Relative and absolute pressure switch type 529

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Viscotherm sensor electronic differential pressure transmitter electronic viscosity controller electric control valve power supply unit starter box

Electromagnetic Flow Meter

Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394

Electronic Pressure Switch EDS 300

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Electronic Pressure Switches

LCD Readout Digital Pressure Switch

4 Posiflow Proportional Solenoid Valves

Model 3051 Pressure Transmitter with HART Protocol

Assisted lift operated 2/2-way solenoid valves Type EV250B

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Safety technique. Emergency stop module BO 5988 safemaster

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

For Multi-Parameter Meters see mvx

Integrating Sound Level Meter and Datalogger

3DLevelScanner II TECHNICAL DATA SHEET

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Telephone- and leased line modem for industrial applications TD-36

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

ATL Fuel Level Sender Probes

Transcription:

SENSE Instruments CO., LTD. Data sheet STK337 Page 1 / 5 Differential Pressure Transmitter STK337 Features and Benefits Maximum range turndown 100:1 Non-Intrusive Magnetic Controls Backlight LCD display for the dark environment Separate electronics and connection compartments O Housing can be rotated through 330 Excellent stability Application Areas For application in the process engineering Suit for liquids, vapour, or gases Preferred areas of use are: Process engineering chemical industry Technical data Measuring range Code Nominal pressure Lower(LRL) Measurement limit Upper(URL) Overload Min.operating pressure 3S 4S 5S 6S 7S 8S 6KPa 7.5KPa 40KPa 200KPa 700KPa 2000KPa 2100KPa 7000KPa -6KPa 6KPa -7.5KPa 7.5KPa 13MPa 0.12Kpa -40KPa 40KPa 13MPa 0.40Kpa -200KPa 200KPa 13MPa 2Kpa -700KPa 700KPa 13MPa 7Kpa -2000KPa 2100KPa 13MPa 21Kpa -2100KPa 2100KPa 13MPa 21Kpa -7000KPa 7000KPa 125% of range 70Kpa On request Power supply (polarity protected) Supply voltage Output signal 2-wire-system Signal range-4 to 20 ma Signal on alarm 12.5...45 VDC 4...20 ma with superimposedsignal for HART protocoldigital communication 3.8mA...22.8mA 3.8mA/ 22.8mA/Others on request

Data sheet STK337 Page 2 / 5 Performance Accuracy Static pressure effect Power supply effect Vibration effect Installation position effect Thermal effect Static pressure Stability Switch on delay Cycle time/updater time Damping Response time Self stability configuration Filter configured Electrical protection Insulation resistance Short-Circuit protection Reverse polarity protection Overvoltage protection Intrinsic safety Humidity Ambient and operation Storage Ingress protection Electromagnetic compatibility(emc) Physical specifications Diaphragms Flange Drain/vent valve Media wetted o-rings Electronic housing Flange screws, identification plate Mounting brackets (Option) Sight glass Filling fluid 3S 0.1% accuracy for range trundown 5:1 (0.1+0.01XURL/Span) between 1/5 and 1/50 of measuring 4S...7S 0.075% accuracy for range trundown 10:1 (0.075+0.00751XURL/Span) between 1/10 and 1/100 of measuring 8S 0.2% accuracy for range trundown 10:1 (0.2+0.01XURL/Span) between 1/10 and 1/100 of measuring Zero error: 0.1%/7Mpa Span error: 0.2%/7Mpa Negligible <0.01% of URL /g when tested 200Hz in any axis relative Zero shift which can be calibrated out, no span effect 0.45%/55 30bar...130bar 0.1% of URL/1 year 5s 0.25s 0 to 100s, step: 0.1s 200 ms (without consideration of electronic damping) 0 to 2% 0 to 16 0 ua >250M Permanent No damage, and no function 500 V Exia Ct4~T6 5...98% -40-85 (without display), -20-70 (with display) -40-85 IP 65 Interference immunity and interference emission according to GB/T17626.2-1998), compliance with IEC 61000-4-3:1995. Stainless steel 316L, Others on request Stainless steel 316 Stainless steel 316 FKM, others on request Die-cast aluminium Carbon steel with Zinc coating Carbon steel with Zinc coating or with painting Laminated safety glass Silicon oil/others on request

Data sheet STK337 Page 3 / 5 Others Display Type Display Range Weight Dimensions Visible range 32.5X22.5mm; 5-digit 7-segment main display, digit height 8mm, 8-digit 14segment additional display, digit height 5mm; 52 bars meter with 2% resolution -1.9.9.9.9. To 9.9.9.9.9. Standard model approx. 3.8kg

Data sheet STK337 Page 4 / 5 Exploded View Operation The STK337 can be operated in the following ways: Using two buttons and zero-adjustment screw Or Operating remotely using the HART protocols -e.g. via HARTTalker and a PC with the SENSE operating programm HARTTran or -using the PDA Software SENSE offers two configuration software. They can be used the PC and PDA. Operation of push buttons The STK337 can be programmed via two buttons and zero-adjustment screw. Following parameters can be adjusted: scaling, decimal point, damping, display model, fix output current, and reset. HART-commnication via HART-protocol the possibility of setting zero and span value is given. HART-communicatin, which can run via PC, note-book, PDA, measured values and parameters become transparent and are available on every step of the signal circuit.

Data sheet STK337 Page 5 / 5 Ordering code STK337 For example:stk337-2dh14s21dcn1b... -40...40Kpa Model Fill fluid Suffix Codes Output 2-- 3-- D- Pressure Type G-- A- Comm.type Meas. Range Wetted parts material Process connections Electrical connection LCD indicator Display Mode Mounting bracket Label Explosion Protection H 1----- 2----- 3----- 2-- 3-- 4-- 5-- 6-- 7-- 8-- 9-- 0-- S----- H----- C----- 1---- 2---- 1-2- N----- D----- C---- R---- P---- A---- B---- N--- 1-0- B------ D------ 4...20mA/2-wire system 1...5V/3-wire system Differential pressure Gauge pressure Absolute pressure HART Protocol Fill fluid Silicone oil Silicone oil Flurocarbon oil Differential Isolating diaphragm SUS 316L SST None With LCD display Cleansing treatment Standard flat type (for horizontal piping) L type (for vertical piping) None Intrinsically safe Approval Flameproof Approval Description Degrease cleansing treatment Degrease cleansing treatment -1.5kPa~-0.05~0 0.05 1.5kPa -6kPa~-0.12~0 0.12 6kPa -40kPa~-0.40~0 0.40 40kPa -200kPa~-2~0 2 200kPa -700kPa~-7~0 7 700kPa -2.1MPa~-0.021~0 0.021 2.1MPa -7MPa~-0.07~0 0.07 7MPa Process Connection Wetted Parts SUS 316 SST SUS 316 SST without process connector (1/4 NPT female on the cover flanges) 1/2 NPT female, two electrical connections M20*1.5 female, two electrical connections 1/2-14 NPT, female, two electrical connections Current % range PV Standard Customer Gauge 0 0.12 6kPa 0 0.40 40kPa 0 2 200kPa 0 7 700kPa 0 0.021 2.1MPa 0 0.07 7MPa 0 0.21 21MPa 0 0.41 41MPa Absolute 0 1 40kPa 0 5 200kPa 0 17.5 700kPa 0 0.05 2.1MPa 0 0.175 7MPa This ordering code contains product specification; properties are not guaranteed. Subject to change without notice.