Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Similar documents
NMI M 6-2 Electricity Meters. Part 2: Test Report Format

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Energy Management Energy Meter Type EM23 DIN

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

AMIS. Automated Metering and Information System. Integration of meters from other manufacturers

RM4TG20 three-phase network control relay RM4-T - range V

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

ELDAŞ Elektrik Elektronik Sanayi ve Tic.A.Ş.

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

7.5 Watt AC-DC Switch Power Supply

Dual Chamber Temporary External Pacemaker

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Waveguide Access Point WGA631. Product Guide

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Redundancy Module QUINT-DIODE/40

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Type: DILM9 10(24VDC) Article No.:

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Type: DILM32 10(24V50HZ) Article No.:

Power Meter Series 700

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Telephone- and leased line modem for industrial applications TD-36

Type: DILM50(230V50HZ,240V60HZ) Article No.:

STRATO LED Drivers 70W, Single output

EMC Test for Compliance with EU EMC Directive 2004/108/EU

TEST REPORT EN (1997) +A1 (2001)

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Analog signal converters CC-E I/I Current / current isolators

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

MasterINTERFACE 39 Series - Relay interface modules

80 Series - Modular timers 16 A. Features

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Huawei NE5000E 400Gbps Flexible Line Processing Unit

Rack mounted telephone- and leased line modem for industrial applications

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

1788 Linking Device Specifications

Trip circuit supervision relay. Type RXTCS

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

MasterINTERFACE 39 Series - Relay interface modules

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Espotel Test Laboratory Services. November 20, 2014

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

15 Series - Electronic step relay and dimmer. Features SERIE

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

DATA SHEET DVI - HDCP Extension Cable

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Operating Manual UWAPS-TINY Series

MHCO MHCO-RI. Transmitter The Transmitter, connected to the system, acquires the inputs and througth a fiber optic transmits it to the receiver.

Preset Counter signo 721

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Features. Picture. Specifications

DS 600. A contact free flux gate based current measurement sensor 600A rms

49 Series - Relay interface modules A. Features

Test Report #: Date: April 8, 2005

ENVIRONMENTAL TEST SPECIFICA- TION FOR INSTRUMENTATION AND AUTOMATION EQUIPMENT

High-ohmic/high-voltage resistors

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Thermistor motor protection

Relés e Contatores de Estado Sólido SIRIUS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

48 SERIES Relay interface modules 10 A

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

TEP 200WIR Series, Watt

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

ANSI Watthour Meter Testing & Certification Programs

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Series AMLDL-Z Up to 1000mA LED Driver

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Transcription:

2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Issue No: 027 Issue date: 10 August 2016 Langer Road Contact: Mr I Frost Felixstowe Tel: +44 (0)1394 694000 Suffolk Fax: +44 (0)1394 276030 IP11 2ER E-Mail: ian.frost@itron.com Website: www.itron.com Testing performed at the above address only SECTION 1: EMC TESTING UTILITY METERING AND ASSOCIATED PRODUCTS eg: Integrating watt-hour meters, gas, water meters Meter attachments (local and remote) Revenue collection products, vending terminals, point of sale equipment, electronic tokens DETAIL OF ACCREDITATION EMC Testing 1.1 Electrostatic discharge up to 15 kv Immunity to Electrostatic Discharge 2 kv to 8 kv Contact Discharge (positive and negative polarities) 2 kv to 15 kv Air Discharge (positive and negative polarities) 1.2 Fast Burst Transients Immunity to Fast Transient Bursts 0.5 kv to 4 kv (positive and negative polarities) EN 61000-4-2:1995, Amds 1 and 2 IEC 60801-2:1991 EN 61000-4-4:1995, Amd 1 EN 61000-4-4:2004 edition 2 IEC 60801-4:1988 1.3 Surge Immunity up to 6.0 kv BS EN 61000-4-5:1995, Amds A1 and A2 1.4 Conducted RF Immunity 150 khz to 80 MHz Voltage levels from 3.0 V to 10.0 V BS EN 61000-4-6:2009 BS EN 61000-4-6:1996, Amds 1 to 3 IEC 61000-4-6:1996, Amd 1 1.5 Immunity to Electromagnetic RF Fields 80 MHz to 2700 MHz Field Levels up to 30.0 V/m BS EN 61000-4-3:2006 Amd 1 and Amd 2 IEC 61000-4-3: 2008 ed 3.1 Assessment Manager: GM Page 1 of 8

SECTION 1: EMC TESTING (cont'd) UTILITY METERING AND ASSOCIATED PRODUCTS eg: Integrating watt-hour meters, gas, water meters Meter attachments (local and remote) Revenue collection products, vending terminals, point of sale equipment, electronic tokens (cont'd) EMC Testing (cont'd) 1.6 Impulse Voltage Tests - Peak voltage 4.0 kv to 12.0 kv - Impulse 1.2/50 s - Source Impedance 40 & 500 - Impulse 0.1/2000 s - Peak voltage up to 8 kv 1.7 AC Voltage Tests 2.0 kv and 4.0 kv RMS at 50 Hz BS EN 61036:1997, Amd 1 IEC 61036:1996, Amd 1, SP Test Method 1618 VDE FNN Guidelines on reliability of electricity meters 2 nd edition November 2011 BS EN 61036:1997, Amd 1, IEC 61036:1996, Amd 1, BS EN 62053-11:2003 BS EN 62053-21:2003 BS EN 62053-22:2003 BS EN 62053-23:2003 IEC 62053-11:2003 IEC 62053-21:2003 IEC 62053-22:2003 IEC 62053-23:2003 BS EN 50470-3:2006 1.8 Voltage dips and interrupts EN 61000-4-11:2004 1.9 Conducted Emissions 150 khz to 30 MHz EN55022:2006 CISPR 22:2008 1.10 Power frequency magnetic fields of external origin. EN 61000-4-8:2010 as limited to requirements of Metering standards EN50470, EN62052 Assessment Manager: GM Page 2 of 8

SECTION 1: EMC TESTING (cont'd) UTILITY METERING AND ASSOCIATED PRODUCTS eg: Integrating watt-hour meters, gas, water meters Meter attachments (local and remote) Revenue collection products, vending terminals, point of sale equipment, electronic tokens EMC Testing (cont'd) 1.11 Immunity against symmetric currents in the frequency range 2-150kHz (High Frequency Pollution Test), with current amplitudes upto 10A rms 1.12 Generic and Product Family Tests These are included to the extent that the standards called up are specifically included in this Schedule. PD CLC/TR 50579:2012 Draft BSEN 61000-4-19 Ed 1, 12/30258875 DC BS EN 61000-6-1:2007 BS EN 61000-6-2:2005 BS EN 61000-6-3:2007 BS EN 61000-6-4:2007 IEC 61000-6-1:2005 IEC 61000-6-2:2005 IEC 61000-6-3:2006 IEC 61000-6-4:2006 BS EN 62053-11:2003 BS EN 62053-21:2003 BS EN 62053-22:2003 BS EN 62053-23:2003 BS EN 61036:1997, Amd 1 IEC 61036:1996, Amd 1 IEC 62053-21:2003 IEC 62053-22:2003 IEC 62053-23:2003 BS EN 50470-2:2006 BS EN 50470-3:2006 Assessment Manager: GM Page 3 of 8

SECTION 2: ENVIRONMENTAL TESTS ENVIRONMENTAL TESTS (non-explosive items) CLIMATIC 2.1 Dry Heat - Steady State Max temp: +85 C Chamber size: 1.0 m x 1.8 m x 1.0 m (high) BS EN 60068-2-2:2007 IEC 60068-2-2:2007 BS EN 60068-2-2:1993, Amd 1, IEC 60068-2-2:1974, Amds 1 and 2 and Sup A, Test Variant Bb 2.2 Cold - Steady State Min temp: -40 C Chamber size: 1.0 m x 1.8 m x 1.0 m (high) BS EN 60068-2-1 :2007 IEC 60068-2-1:2007 BS EN 60068-2-1:1993, Amds 1 and 2, IEC 60068-2-1:1990, Amds 1 and 2, Test Variant Ab 2.3 Damp Heat, Cyclic Upper temp +40 C and +55 C, Variant 1 & 2 Humidity range: 30% to 98% RH Chamber size: 1.0 m x 1.8 m x 1.0 m (high) BS EN 60068-2-30:2005 IEC 60068-2-30:2005 2.4 Ingress testing Ingress Protection Tests (Dust) IP5X Dust Protected Ingress Protection Tests (Water) IPX1 Protected against falling water IPX2 Protected against dripping water when tilted up to 15 IPX3 Protected against spraying water IPX4 Protected against splashing water BS EN 60529:1992 (2013) Amd 2 Assessment Manager: GM Page 4 of 8

SECTION 2: ENVIRONMENTAL TESTS (cont d) ENVIRONMENTAL TESTS (non-explosive items) (cont d) DYNAMIC Single Parameters 2.5 Vibration - sinusoidal (ambient temperature) Frequency range: 10 Hz to 150 Hz Max pk-pk displacement: 25 mm Environmental Test - Electrical 2.6 Heating Test (Temperature Rise) To measure the temperature rise of units under draft and solar free conditions at 10 C to 50 C, when current and voltage are applied 45 V to 280 V 1.0 A to 120 A 50Hz only Maximum Recorded absolute Temperature 120 C Ambient Temperature 20 C to 50 C BS EN 60068-2-6:2008 IEC 60068-2-6:2007 BS EN 60068-2-6:1996 IEC 60068-2-6:1995 : Clause 7.2 Clause 7.2 Clause 7.2 Mechanical Tests 2.7 Mechanical strength of casing 0.2 Nm to 1 Nm 2.8 Mechanical strength of casing 0.22 Nm BS EN 60068-2-75:1997 BS EN 60068-2-75:2014 IEC 60068-2-75:1997 BS EN 60687:1993, Amd 1, IEC 60687:1992, BS EN 61268:1996, IEC 61268:1995, Limitation: Clause 5.2.1, Mechanical strength only* Assessment Manager: GM Page 5 of 8

SECTION 2: ENVIRONMENTAL TESTS (cont d) ENVIRONMENTAL TESTS (non-explosive items) (cont d) Environmental Tests 2.9 Generic and Product Family Tests These are included to the extent that the standards called up are specifically included in this Schedule. BS EN 62053-11:2003 BS EN 62053-21:2003 BS EN 62053-22:2003 BS EN 62053-23:2003 BS EN 61036:1997, Amd 1 IEC 61036:1996, Amd 1 BS EN 50470-2:2006 BS EN 50470-3:2006 IEC 62053-11:2003 IEC 62053-21:2003 IEC 62053-22:2003 IEC 62053-23:2003 Assessment Manager: GM Page 6 of 8

SECTION 3: ENERGY MEASUREMENT AC Energy, Single and Polyphase Active and Reactive UTILITY METERING AND ASSOCIATED PRODUCTS eg: Integrating watt-hour meters, gas, water meters Meter attachments (local and remote) Revenue collection products, vending terminals, point of sale equipment, electronic tokens 3.0 45 V to 280 V 0.020 A to 120 A 45 Hz to 65 Hz Power Factor Cos Ф 1 to 0.5 inductive or capacitive Sin Ф 1 to 0.25 inductive or capacitive Can be combined with reduced or elevated temperature between - 40 C to + 85 C Can be combined with AC magnetic Field at 0.5 mt Or can be combined with a DC magnetic field of 1000 Ampere-turns BS EN 61036:1997, Amd 1 (Withdrawn) BS EN 50470-2:2006 BS EN 50470-3:2006 IEC 62053-11:2003 IEC 62053-21:2003 IEC 62053-23:2003 BS EN 62053-11:2003 BS EN 62053-21:2003 BS EN 62052-23:2003 BS EN 62053-24 :2015 Including test types: Limit of error due to variation of the current. Variation with voltage. Severe voltage variation. Variation with frequency. Self heating. Test of no-load. Test of starting. Temperature variation. Maximum permissible errors. Repeatability. Reverse phase sequence. Voltage unbalance. Current unbalance. Power frequency magnetic fields of external origin. Continuous magnetic fields of external origin. Power Consumption in the voltage and current circuits Meter Constant Start up time Energy measurement in the presence of DC and Even Harmonics, Odd Harmonics and Sub Harmonics Assessment Manager: GM Page 7 of 8

SECTION 4 ACCURACY OF TIME KEEPING 4.0 Accuracy of time keeping, for meters incorporating timeswitched elements BSEN62052-21:2004 BSEN62054-21:2004 END Assessment Manager: GM Page 8 of 8