I/O module, analogue outputs and universal inputs, modu570

Similar documents
Digital input modules

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Modular I/O System Analog and Digital Interface Modules

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Electronic Control Devices The European Product Catalogue 2007

Duct Humidity Transmitter

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Combi switchbox with integrated 3/2 way pilot valve

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Product and functional description

MINI MCR-SL-R-UI(-SP)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

ABB i-bus EIB Logic Module LM/S 1.1

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

TX OPEN RS232/485 module

ABB Drives. User s Manual HTL Encoder Interface FEN-31

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Quick Connect. quick - simple - efficient.

Electronic Control Devices The European Product Catalogue 2007

PCS0100en Persy Control Services B.V. Netherlands

Model: DC-A2IO Advanced HVAC Controller

Air damper actuators

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Disturbance Recoder SPCR 8C27. Product Guide

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Automation Unit TM 1703 ACP Flexible automation and telecontrol

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Digital Pressure Measuring Instrument MDR480

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

EXTERNAL DIMENSIONS AND PARTS

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

is then retained absolutely without interruption.

IO-RM3 3-Stage Relay Module

ACS-30-EU-EMDR-10-MOD

NEW. EVEN MORE data acquisition and test stand automation

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

DALI RC BASIC SO. Control unit Operating instructions

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

ABB i-bus KNX SA/S Switch Actuators Product Manual

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Multifunction devices

Belimo Gateway MP to Modbus RTU - UK24MOD

Voltage Regulator SPAU 341 C. Product Guide

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

ABB i-bus KNX Fan Coil Controller FC/S 1.1

RRV934. Multi-controller. Synco living

Hand-held thermometer Model CTH7000

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Adjustment functions for both span and shift have been incorporated

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Sensing element Polymer humidity capacitor Operating range humidity 0-100%RH; temperature -40~80Celsius Accuracy

HERZ-Thermal Actuators

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

SYSTEM DESCRIPTION Termination Boards

CONFIGURABLE SAFETY RELAYS

Actuator for modulating control AME 435

Safety technique. Emergency stop module BO 5988 safemaster

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

Heating Controller. Building Technologies HVAC Products

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

GREISINGER electronic GmbH

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

WD-AMX Water Detection Controllers

CONFIGURABLE SAFETY RELAYS

Combi B Alarm box. Mounting instructions

USB-AD16f Data acquisition system (USB)

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Installation manual. Generator Paralleling Controller GPC multi-line C

Proportional pressure regulators VPPE

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Electric Rotary Actuator - On/Off or programmable control actuator

Transcription:

Product data sheet 92.061 EY-IO 570: I/O module, analogue outputs and universal inputs, modu570 How energy efficiency is improved SAUTER EY-modulo 5 technology: modular, fast and universal Features Part of the SAUTER EY-modulo 5 system family 12 inputs and outputs Plug-in element for extending the modu525 automation station (AS) Power supply from modu525 AS Direct labelling on the front Can be equipped with a local operating and indicating unit EY-IO570F001 Technical data Power supply Power supply From modu525 AS via I/O bus Power consumption1) 1.5 VA/0.8 W Power loss 0.8 W Current consumption2) 50 ma Operating temperature 0...45 C Ambient conditions Storage and transport temperature -25...70 C Admissible ambient humidity 10...85% rh, no condensation Analogue outputs 4 (push-pull) Load 2 ma Universal inputs 8 Inputs/Outputs Analogue Ni1000/Pt1000, U/I/R, Pot Digital DI (approx. 3 Hz) Interfaces and communication Connection for modu6 (LOI) 6-pin, integrated Connection, I/O bus 12-pin, integrated Connection terminals 24 (0.5...2.5 mm²) Fitting On top-hat rail Dimensions W x H x D 42 170 115 mm Weight 0.29 kg Type of protection IP 30 (EN 60529) Protection class I (EN 60730-1) Construction Standards and directives CE conformity according to Environment class 3K3 (IEC 60721) EMC directive 2004/108/EC EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 Overview of types Type Properties EY-IO570F001 I/O module, analogue outputs and universal inputs, modu570 1) 2) On the primary side of modu525 base station (230 V~) Supply from modu525 base station Right of amendment reserved 2015 Fr. Sauter AG 4.1 1/6

Accessories Local operating and indicating units (LOI) Type EY-LO630F001 EY-LO670F001 Description Description of operation 16-LED indication, bi-colour 4 setpoint transmitters (A-0 100%), 8 LEDs for operation/indication The modu570 I/O module is used for actuation with a standard signal (0...10 V), receiving digital (alarm/status) and analogue inputs (Ni/Pt1000, U/I/Pot) in operational systems, e.g. in HVAC engineering. The I/O module has a total of 4 analogue outputs and 8 universal inputs. Intended use This product is only suitable for the purpose intended by the manufacturer, as described in the Description of operation section. All related product regulations must also be adhered to. Changing or converting the product is not admissible. Engineering notes The modu570 I/O module is generally comprised of two components. The baseplate in which the I/O bus system and the connection terminals are integrated and the actual I/O module electronics. Fitting/assembly The baseplate of the I/O module is fitted in a cabinet using a top-hat rail (EN 60715) and connected on the side directly to the I/O bus of the modu525 AS or modules. This work must only be carried out in the de-energised state. The baseplate contains the bus module, which is responsible for power supply and continuous communication. This ensures that faults due to a failure or partial defect in the electronic component do not affect the function of other downstream modules. Removing/inserting the I/O module electronics from/to the baseplate is possible while the AS is in operation. To ensure plant safety and to avoid any faults at inputs or outputs, the I/O module electronics should only be removed or inserted while the base station is switched off. The return line of the Ni/Pt1000 sensors must be separated from the other inputs and outputs, i.e. separate GND terminals must be used. Labelling concept The I/O module can be labelled with a paper insert in the frontal transparent cap. There are specially perforated label sheets available for this purpose. The labelling is usually carried out using texts generated from CASE Suite, and the labels are printed on normal A4 paper using commercial printers. Assigning modules to AS The I/O module electronics are encoded on the hardware side using pin inserts so that only the appropriate baseplate can be used. The modu525 AS detects whether a module baseplate is plugged into the I/O bus. Baseplate number and assignment of module types for the I/O modules on the AS are defined with CASE Suite. This information is permanently stored in the AS. LED indicator/function The I/O module is equipped with a system LED that indicates the operating statuses as follows: System LED LED I/O bus Status Description No designation Continuous green light Module in operation Flashing green or red Alternating green red off No indicator Module not ready for operation Lamp test active (indicator type priority) No power supply 2/6 4.1 Right of amendment reserved 2015 Fr. Sauter AG

Analogue outputs Number of outputs 4 Type of outputs Analogue outputs 0(2)...10 V= Load up to 2 ma per output Return line grounded Update rate Resolution 100 ms 13 bits The output voltage is taken from between an output terminal (a0...a3) and a ground terminal. The outputs are designed as push-pull outputs with active sink capability. Every output can be subjected to a load of 2 ma. The outputs are protected against static discharges, not against AC or DC that is present. Universal inputs Number of inputs Type of inputs (software coding) Protection against external voltage Ni/Pt/U/R/Pot/DI I (channel u8, u9) 8 (UI) Ni1000 (DIN 43760) Pt1000 (EN 60751) Voltage measurement (U) Current measurement (I) channel u8, u9 only! Potentiometer input (Pot) Resistance (R) ±30 V/24 V~ (without destruction) +12 V/-0.3 V (without destruction) Reference U ref 1.23 V (terminal no. 22) Update rate Channels u8, u12 Channels u9, u10, u11, u13, u14, u15 For temperature measurement (independent of channel) Resolution Measuring ranges Voltage (U) Current (I) Potentiometer (Pot.) 100 ms 500 ms 3 s 14 bits 0 (2)...10 V, 0 (0.2)...1 V 0 (4)...20 ma 0...1 (100%) with 3-wire connection (1 100 kω) Reference U ref 1.23 V (terminal no. 22) Resistance (R) Temperature Ni1000 Pt1000 Digital input load max. 10 ma 200 2500 Ω -50...+150 C -50...+150 C Potential-free contacts with ground connection opto-coupler, transistor (open collector) approx. l out = 1.2 ma Pulse counter 3 Hz (100 ms update interval) 0.5 Hz (500 ms update interval) Temperature measurement (Ni/Pt) The Ni/Pt1000 sensors are connected using two wires between one of the input terminals for universal inputs (channel u8...u15) and a ground terminal. The inputs require no calibration and can be used directly. Line resistance of 2 Ω is pre-compensated as standard. With the correct line resistance of 2 Ω (cable cross-section 1.5 mm²), the power cable (wire) may be no more than 85 m. Larger line resistances can be compensated by the software. The measurement current is pulsed to ensure that the sensor is not heated (l meas approx. 0.3 ma). Voltage measurement (U) The voltage to be measured is connected between an input terminal for universal inputs (channel u8...u15) and a ground terminal. The signal must be potential-free. The measuring ranges with or without offset 0 (0,2)...1 V or 0 (2)...10 V are selected through the software. The internal resistance R i of the input (load) is 9 MΩ. Right of amendment reserved 2015 Fr. Sauter AG 4.1 3/6

Current measurement (I) The current can only be measured at two inputs. The current to be measured is connected at one of the two input terminals for universal inputs (channel u8, u9) and a ground terminal. The current signal must be potential-free. The measuring ranges with or without offset 0 (4)...20 ma are selected via the software. The internal resistance R i of the maximum input current must be limited to 50 ma. The internal resistance R i is < 50 Ω. Potentiometer measurement (Pot) The potentiometer is connected between an input terminal for universal inputs (channel u8...u15), a ground terminal and the terminal U ref (reference voltage). The reference output is not short circuitproof. To avoid overloading the reference output, the overall resistance of all connected potentiometers may not drop below 123 Ω (max. 10 ma load). For a stable, interference-free measurement, a potentiometer value of 10 kω is recommended. ) Note To maintain measuring accuracy, ground connections should always be connected to the same type of input. For an optimum connection, we recommend connecting one ground terminal of the I/O module directly with the AS or each appropriate cabinet terminal. Digital inputs (DI with UI) The AS also records binary information with the universal inputs. The information (alarm/status) is connected between an input terminal (u8...u15) and a ground terminal. The station applies a voltage of approximately 13 V to the terminal. If a contact is open, this usually corresponds to an INACTIVE state (bit = 0). If a contact is closed, there is an ACTIVE state (bit = 1) and 0 V is applied, giving a current of approximately 1 ma. Short-term changes of at least 20 ms between the queries of the station are stored temporarily and processed in the next cycle. Every input can be defined individually as an alarm or a status by setting software parameters. The digital inputs can be displayed with a local indicating unit (e.g. modu630 accessory). Technical specifications of the inputs and outputs Universal input Measuring range Resolution Precision a x measuring span + b x measured value Ni/Pt1000-50 +150 C < 0.05 K ± 0.5% ± 0.5% U (0/0.2...1 V) 0.02...1.1 V < 0.1 mv ± 0.5% ± 0.5% U (0/2...10 V) 0.15...10.2 V < 1 mv ± 0.5% ± 0.5% I (0/4...20 ma) 0.5...22 ma < 0.02 ma ± 1% ± 2% R 200 2500 Ω < 0.1 Ω ± 0.2% ± 1% Pot ( 1 kω) 2...100% < 0.5% ± 1% ± 1% Example of calculating the accuracy: Measured value 20 C. Measuring span: -50 C + 150 C = 200K Precision = a x measuring span + b x measured value = ±0.5% x 200K ±0.5% x 20 C = ±1K ±0.1K = ±1.1K Analogue output Range of adjustment Resolution Accuracy AO (0/2 10 V) 0.01...10.2 V < 2 mv 1% of the end value Binary input (0-I) Switching threshold inactive 0 Switching threshold active 1 Switching hysteresis Pulse counter with universal input (UI) > 3 V < 1.5 V > 0.4 V 3 Hz Channel and terminal assignment Description modu570 Channel Schematic Terminals Signal Analogue output (0...10 V) 0 a0 2 1 1 a1 4 3 2 a2 6 5 3 a3 8 7 GND 4/6 4.1 Right of amendment reserved 2015 Fr. Sauter AG

Description modu570 Channel Schematic Terminals Signal Universal input 8 u8 13 9 (Ni/Pt1000 / U/R/Pot) 9 u9 14 Power signal only on channels 8, 10 u10 15 16 9 or terminals 13, 14 11 u11 17 18 12 u12 19 20 13 u13 21 14 u14 23 15 u15 24 Reference voltage 1.23 V 22 Connection of local operating unit The modu570 I/O module can be complemented with a modu670 local operating and indicating unit (LOI) to allow direct actuation of positioning signals and display of digital inputs. The function corresponds to the standard EN ISO 16484-2:2004 for local override and indicating units. The modu630 local indicating unit can also be used. The unit can be installed and removed during operation (hot-pluggable) without affecting functions of the AS or I/O module. Detailed information about the actuation function and LED indicator can be found in the PDS 92.081 for EY-LO 6**. If an incompatible operating unit is connected, this status is indicated by the flashing of all LEDs (red and yellow). There is no risk of the I/O module being destroyed. ) Note Before insertion, all controller positions (AUTO) must be checked to ensure that no undesired signal values are issued. When the unit is removed, all outputs are operated with the automatic values of the AS or I/O module. In accordance with the standard, the local override and indication devices allow restricted operation of system components without the involvement of the AS intended for the application. Outputs of the AS or the I/O modules in manual position may change the value briefly when the user program is downloading. The local operating unit can be used to actuate the analogue outputs in the AS directly even without a user application (CASE Engine). Disposal When disposing of the product, observe the currently applicable local laws. More information on materials can be found in the Declaration on materials and the environment for this product. GND Right of amendment reserved 2015 Fr. Sauter AG 4.1 5/6

Connection diagram a0 a1 a2 a3 01 03 05 07 09 11 02 04 06 08 10 12 4 x AO 0(2) 10V Analog outputs 8 x UI Universal inputs Ref Reference signal 13 15 17 19 21 23 14 16 18 20 22 24 u8 u9 u10 u11 u12 u13 u14 u15 0-20 ma (16, 18, 20) 0-10V 1...100 k Ref (22) A10510a Dimension drawing 42 115 M11416 85 170 85 Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 www.sauter-controls.com 6/6 4.1 Right of amendment reserved 2015 Fr. Sauter AG