BNC (75 Ohm) Coaxial Calibration Kit

Similar documents
V281C/D and W281C/D 1.0 mm Coaxial to Waveguide Adapters. Operating and Service Manual

MAURY. VNA Calibration Kits, Microwave Components & Adapters. Calibrate With Confidence IN THIS CATALOG:

Measurement & Modeling Device Characterization Solutions

Keysight N9911X Economical Waveguide Calibration Components

spinner Measurement & Calibration equipment for network analyzers

About this Manual. Support for Your Product

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Contents i. CNX MIDI Interface Expansion Card: CNXMIDI 0

SATA Test Adapter User Manual

281A/B Adapters. Operating and Service Manual

Powerware Relay-Serial Card User s Guide

User s and Service Guide

Keysight N9911X Economical Waveguide Calibration Components

Agilent 85052D 3.5 mm Economy Calibration Kit

TC Electronic Extended Warranty Policy

ATS Overhead Table Shelf System INSTRUCTION MANUAL

DVI to Analog Converter

TTL to RS232 Adapter User Guide

Agilent Measuring Noninsertable Devices

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

Agilent P940xA/C Solid State PIN Diode Switches

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

Installation Instructions

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

Amplified High Speed Fiber Photodetectors

SKY LF: GHz Two-Way, 0 Degrees Power Divider

Agilent N9911X Economical Waveguide Calibration Components

NFC Communication Tray Model: HHX-IT3-Z

MICRO-COAX Space Grade Cable Assembly Integration Manual

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

W1 Connector W1 Adapter W1 Termination

User's Guide. Integrating Sound Level Datalogger. Model Introduction

This product has the equivalent gain performance with the 14 element Yagi antenna.

SC Series: MIS Chip Capacitors

Installation and Operation Manual. for the. IPC-1, Bi-Directional stereo level matching interface

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

MTX-D, Oil Temperature/Pressure Gauge

Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

PS/2 Extender USER MANUAL.

Agilent X/P/K281C Adapters

INSTRUCTION MANUAL MODEL PCD-88

Current Probes. User Manual

Installation and Maintenance Instructions

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

HDMI To Composite/S-Video Scaler. GTV-HDMI-2-COMPSVIDS User Manual.

Table of Contents WARNING SYMBOLS AND DEFINITIONS

TRANSLATOR INSTALLATION AND OPERATIONS MANUAL KEYBOARD AND MOUSE CONVERTER Stancliff Road Phone: (281)

MTV-FS1 / FS1T / FSB375

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

2. The Vector Network Analyzer

Application Guide to RF Coaxial Connectors and Cables

HotLok Pass Through Blanking Panel

VK-250 WARRANTY REGISTRATION FORM

OAK WORKBENCH WITH 2 DRAWERS

StorTrends 3400 Hardware Guide for Onsite Support

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Replacing N-300 PCB YZ Systems for use by YZ s distribution network and end-users.

Installation & Operation Manual

BroadBand PowerShield. User Manual

Serial ATA Hard Drive Enclosure

The SMA RF Connector and Associated Tools Whitham D. Reeve

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

PERFORMANCE AND VALUE FOR YOUR DAY-TO-DAY TEST APPLICATIONS.

R&S ZCxxx Millimeter-Wave Converters Specifications

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide

WristPC. WristPC Wearable Keyboard QWERTZ Special (Version 2.0L and above) Copyright L3 Systems, Inc. Redmond, WA

Seven function digital multimeter

INSTALLATION INSTRUCTIONS

HYDRA Z Owner s Manual

How To Install A Power Supply (Uplast) With A Battery Pack

STAGE SETTER-8. User Instructions. Elation Professional

SURROUNDVIEW Installation and Setup User s Guide

CITRIX SYSTEMS, INC. SOFTWARE LICENSE AGREEMENT

Single Port T1/E1 Tap

SKY LF: 20 MHz-3.0 GHz High Power SP4T Switch With Decoder

User Guide. HDMI Active Cable Extender. DVI-7370c

TERMS AND CONDITIONS 1 CONTRACT INFORMATION

Part I - Installation

Advantium 2 Plus Alarm

KVM - DVI, USB 2.0, Cat 5 Extender

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Benchtop Computer Monitor Generator

PTU Series Ultrahigh-Purity Pressure Transducers

Old Company Name in Catalogs and Other Documents

Master Anamorphic Lens 100/T1.9 Lens Flare Set. Date: May 2015

i410/i1010 AC/DC Current Clamp

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner

Hi5. HD-SDI/SDI To HDMI Video and Audio Converter User Manual. December 17, 2008 P/N For Hi5 Serial Number or Later

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

TBM5, TBM5-S and TBM5-SV

IEEE /ZigBee USB Dongle

Transcription:

User Guide BNC (75 Ohm) Coaxial Calibration Kit Model: 8580CK10 8580-511 (A) 3/15

User Guide BNC (75 Ohm) Coaxial Calibration Kit Model: 8580CK10 2900 Inland Empire Boulevard Ontario, California 91764-4804 USA Telephone: (909) 987-4715 Facsimile: (909) 987-1112 maurymw.com Copyright 2015 Maury Microwave Corporation. All rights reserved.

Warranty Maury Microwave hardware products are warranted against defects in materials and workmanship for a period of one year from date of shipment. During the warranty period, Maury Microwave will, at its option, either repair or replace products which prove to be defective. Maury Microwave software products are warranted against defects in material and workmanship of the media on which the product is supplied for a period of ninety (90) days from date of shipment. Maury also warrants that the product shall operate substantially in accordance with published specifications during the same warranty period. During the warranty period, Maury Microwave will, at its option, either repair or replace products which prove to be defective. Maury does not warrant that the operation of the product shall be uninterrupted or error-free. For warranty service or repair, all products must be returned to Maury Microwave and must be issued a return authorization number by Maury prior to shipment. Buyer shall prepay shipping charges to Maury. Obligation is limited to the original Buyer. Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the Buyer, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or wear resulting from normal use. No other warranty is expressed or implied. Maury Microwave specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. The remedies provided herein are the Buyer s sole and exclusive remedies. Maury Microwave shall not be liable for any direct, indirect, special, incidental, or consequential damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or any other financial loss) arising out of the Buyer s use of or inability to use the product, even if Maury or an authorized Maury dealer has been advised of the possibility of such damages.

Contents General Information... 1 Calibration Kit Description... 1 Maintenance... 1 Calibration... 1 Supporting Test Port Adapters... 1 Electrostatic Discharge Precautions... 1 Connector Description... 2 Connector Care... 2 Calibration Kit Contents... 3 Standard Definitions... 5 Anritsu Network Analyzers... 5 Keysight Network Analyzers... 6 Rohde & Schwarz Network Analyzers... 7 Appendix... 9 Data Sheet Resources... 9 Contacts... 11 8580-511 (A) 3/15 i

Contents Tables Table 1. Male Standard Definitions for Anritsu... 5 Table 2. Female Standard Definitions for Anritsu... 5 Table 3. Standard Definitions for Keysight... 6 Table 4. Standard Definitions for Rohde & Schwarz... 7 Figures Figure 1. BNC Connector Interfaces... 2 ii 8580-511 (A) 3/15

General Information Calibration Kit Description The 8580CK10 series of BNC 75 ohm coaxial calibration kits is designed to provide accurate calibrations of network analyzers in the DC to 12 GHz range. Each of these kits includes all the necessary calibration standards for the accurate calibration of most network analyzers. See the following Calibration Kit Contents section for information on included components and available kit options: Refer to Maury Microwave data sheet 2Z-069, available on our website, for further specifications on the Maury Microwave 8580CK10 series of coaxial calibration kits. NOTE: This document, calibration constants software, and data sheet can be downloaded from our website: maurymw.com NOTE: Legacy analyzer software is not on our website but is available for purchase. Maintenance This calibration kit is relatively maintenance free if the components are handled with the same care that is appropriate to all precision equipment. As with any precision component, proper care should be taken to assure clean mating surfaces, correct alignment when mating, and proper torquing of connectors or waveguide coupling screws. To help maintain the integrity of the components in this kit, routine visual inspection and cleaning of mating surfaces is recommended. Failure to do so may result in degraded repeatability and accuracy, as well as damage any mated devices. Calibration To maintain verification that a calibration kit is performing to traceable specifications, we recommend that all kits be periodically returned to Maury Microwave for calibration. The typical calibration cycle is one year, although actual need may vary depending on usage. Supporting Test Port Adapters When configuring a test setup, be sure that damaging stresses are not applied to the connectors on the test set. This is particularly critical when the attached components are heavy or long. Always properly support the test port adapters being used. Electrostatic Discharge Precautions Protection against electrostatic discharge (ESD) is essential while inspecting, cleaning, or making connections to connectors attached to a static-sensitive circuit, such as those found inside test sets. When handling the connectors on the test set, be aware that you are coming in contact with exposed center conductors that are connected directly to the static-sensitive internal circuits of the network analyzer. Make sure that you and your equipment are well-grounded before inspecting, cleaning, or making connections to test set ports. Standard ESD precautions, such as the use of grounded wrist straps and grounded antistatic mats, are recommended. 8580-511 (A) 3/15 1

General Information Connector Description All calibration standards and adapters in the 8580CK10 series kits utilize the Maury Microwave Precision BNC 75 Ohm Connector, which is compliant with MIL-C-39012 specifications. Figure 1. BNC Connector Interfaces Connector Care Precision connectors must be handled carefully if accurate calibrations and measurements are to be obtained. All connectors should be inspected prior to each use. For optimum measurement results, all interfaces should be visually inspected under magnification and cleaned on a regular basis. Proper connector contact pin depths should also be verified through regular inspections using a connector gage, such as the Maury Microwave A012A connector gage kit, to insure that the connectors on both calibration devices and devices under test (DUTs) have contact pin depths within recommended tolerances. See Figure 1 above for proper pin and dielectric depth specifications for the BNC connector. Care should be used whenever aligning connectors. Tighten connector coupling nuts using an appropriate torque wrench while holding the opposing connector with an open-end wrench. When disconnecting devices, take care not to rock or bend any of the connections. Disconnect devices by disengaging the coupling nuts and gently pulling the connectors apart in a straight line. Always use protective covers on all connectors when devices are not in use. Should a connector become damaged, it should be repaired before it is used any further or replaced immediately. A damaged connector can damage other mated connectors. CAUTION: Do not mate BNC 75 ohm connectors to BNC 50 ohm connectors. Mating a BNC 75 ohm female connector to a BNC 50 ohm male connector will destroy the contact on the BNC 75 ohm female connector. Mating a BNC 75 ohm male connector to a BNC 50 ohm female connector will not provide proper electrical contact for the center conductors. 2 8580-511 (A) 3/15

General Information Calibration Kit Contents Standard Components 8580CK10 1 ea Short, female 8584A1 1 ea Short, male 8584B1 1 ea Open, female 8585A1 1 ea Open, male 8585B1 1 ea Fixed Termination, female 8583A1 1 ea Fixed Termination, male 8583B1 1 ea Case Assembly 8580-511 (A) 3/15 3

General Information (This page intentionally left blank) 4 8580-511 (A) 3/15

Standard Definitions Anritsu Network Analyzers Table 1. Male Standard Definitions for Anritsu BNC Male Open Device C0 46.5 e-15 C1 0 C2 88.0 e-36 C3 0 Offset Length 2.716 cm Serial Number 00000 BNC Male Short Device Offset Length 2.802 cm Serial Number 00000 Table 2. Female Standard Definitions for Anritsu BNC Female Open Device C0 61.5 e-15 C1-3000 e-27 C2 100 e-36 C3-5.9 e-45 Offset Length 2.122 cm Serial Number 00000 BNC Female Short Device Offset Length 2.200 cm Serial Number 00000 For specific loading instructions, see Anritsu loading instructions, which can be downloaded from our website: maurymw.com. 8580-511 (A) 3/15 5

Standard Definitions Keysight Network Analyzers Table 3. Standard Definitions for Keysight Standard (1) Type Description C0 x10-15 F L0 x10-12 H C1 x10-27 F/Hz L1 x10-24 H/Hz C2 x10-36 F/Hz 2 L2 x10-33 H/Hz 2 C3 x10-45 F/Hz 3 L3 x10-42 H/Hz 3 Fixed or Sliding (2) Delay ps Offset Z0 (3) Ω Loss (4) GΩ/s Frequency GHz Coax or W/G Min Max Standard Label Short Female Short 73.383 75 1.4 0 999 Coax 8584A1 Open Female Open 61.5-3000.0 100-5.9 70.782 75 1.4 0 999 Coax 8585A1 Load Female Fixed Fixed 0 75 0 0 999 Coax 8583A1 Thru Thru (0 cm) 0 75 0 0 999 Coax THRU (5) Short Male Short 93.463 75 1.4 0 999 Coax 8584B1 Open Female Open 46.5 0 88.0 0 90.595 75 1.4 0 999 Coax 8585B1 Load Male Fixed Fixed 0 75 0 0 999 Coax 8583B1 (1) (2) (3) (4) Open, short, load, delay/thru, or arbitrary impedance. Load or arbitrary impedance only. Z0 normalized. Skin loss factor, normalized at 1 GHz. (5) Test ports connected directly. For specific loading instructions, see Keysight loading instructions, which can be downloaded from our website: maurymw.com 6 8580-511 (A) 3/15

Standard Definitions Rohde & Schwarz Network Analyzers Table 4. Standard Definitions for Rohde & Schwarz Short (M) Label (1) Min Freq Max Freq Length Loss = 8584B1 = 0 Hz = 12 GHz = 28.019 mm = 0.015154 db/ GHz Through (MF) Label (1) Min Freq Max Freq Length Loss = 0 cm Thru = 0 Hz = 12 GHz = 0 mm = 0 db/ GHz Short (F) Label (1) Min Freq Max Freq Length Loss = 8584A1 = 0 Hz = 12 GHz = 21.999 mm = 0.011898 db/ GHz Match (M) Label (1) Min Freq Max Freq = 8583B1 = 0 Hz = 12 GHz Open (M) Label (1) = 8585B1 Min Freq = 0 Hz Max Freq = 12 GHz Length = 27.159 mm Loss = 0.014689 db/ GHz C0 = 46.5 ff C1 = 0 ff/ghz C2 = 0.088 ff/ghz 2 C3 = 0 ff/ghz 3 Match (F) Label (1) Min Freq Max Freq = 8583A1 = 0 Hz = 12 GHz Open (F) Label (1) = 8585A1 Min Freq = 0 Hz Max Freq = 12 GHz Length = 21.220 mm Loss = 0.011476 db/ GHz C0 = 61.5 Ff C1 = -3 ff/ghz C2 = 0.100 ff/ghz 2 C3 = -0.006 ff/ghz 3 For specific loading instructions, see Rohde & Schwarz loading instructions, which can be downloaded from our website: maurymw.com. 8580-511 (A) 3/15 7

Standard Definitions (This page intentionally left blank) 8 8580-511 (A) 3/15

Appendix Data Sheet Resources 2Z-069 Precision Calibration Kits BNC Coaxial Connectors Vector Network Analyzers http://maurymw.com/pdf/datasheets/2z-069.pdf 2Y-009 Connector Gage Kit Precision TNC / BNC Connectors http://maurymw.com/pdf/datasheets/2y-009.pdf 2Z-001 Test Port Cable Assemblies and Test Port Adapters http://maurymw.com/pdf/datasheets/2z-001.pdf 8580-511 (A) 3/15 9

Contacts Corporate Maury Microwave Corporation 2900 Inland Empire Boulevard Ontario, California 91764-4804 United States of America Tel. 909-987-4715 Fax 909-987-5855 Email maury@maurymw.com Sales Tel. 909-204-3224 Fax 909-987-1112 Email maury@maurymw.com Customer Support Tel. 909-204-3283 Fax 909-987-1112 Email support@maurymw.com Website maurymw.com Web Resources Maury Calibration Kits http://maurymw.com/precision/vna_cal_kits.php Maury Precision Coaxial and Waveguide-to-Coaxial Adapters http://maurymw.com/finder/adapter_finder.php Maury Applications Notes Library & Technical Articles Archive http://maurymw.com/support/tech-support.php Maury Sales Representative Finder http://maurymw.com/support/find-sales-rep.php Visit our website for additional product information and literature.