Keysight Technologies Extending the Measurement Plane up to 1 km in Vector Network Analysis. Application Brief

Similar documents
Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Agilent E5063A ENA Series Network Analyzer

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Keysight E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software

Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes

Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Keysight N9320B RF Spectrum Analyzer

802.11ac Power Measurement and Timing Analysis

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Keysight N6854A Geolocation System. Configuration Guide

PXI and AXIe Modular Instrumentation

Agilent U2000 Series USB Power Sensors

Agilent U2000 Series USB Power Sensors

The Next Generation in Automated Oscilloscope Test

Keysight Technologies N9320B RF Spectrum Analyzer

PXI and AXIe Modular Instrumentation

Make Better RMS Measurements with Your DMM

Variable Frequency Drive Troubleshooting with U1610A/U1620A

Agilent FieldFox Remote Viewer

Agilent 87421A/87422A Power Supply

DDR Memory Overview, Development Cycle, and Challenges

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Agilent U2000 Series USB Power Sensors

Keysight Technologies Test Case Manager N7649B

Keysight Technologies Solutions for WLAN ac Manufacturing Test

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Evaluating Oscilloscope Bandwidths for Your Application

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

N6171A MATLAB Data Analysis Software for Agilent Instruments

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Keysight E5063A ENA Series PCB Analyzer

Keysight Technologies DVB-T and DVB-T2 Receiver Test Challenges. Application Note

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

Real-Time Spectrum Analysis for Troubleshooting n/ac WLAN Devices

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Keysight Technologies Quickly Identify and Characterize Thermal Measurement Points

Keysight Technologies Compatibility of USB Power Sensors with Keysight Instruments. Application Note

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

PCI Express 1.0 (2.5 GT/s) Protocol Test

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Keysight Technologies How to Choose your MAC Lever. Technical Overview

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

AXIe: AdvancedTCA Extensions for Instrumentation and Test

An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T Devices

Keysight Technologies Drive Down the Cost of Test Using the ENA Series of Network Analyzers. Application Note

Agilent Test Solutions for Multiport and Balanced Devices

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

Keysight Technologies DVB-T and DVB-T2 Transmitter Test Challenges. Application Note

Agilent 4338B Milliohm Meter

1.5 GHz Active Probe TAP1500 Datasheet

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Keysight U8480 Series USB Thermocouple Power Sensors

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

E5092A Configurable Multiport Test Set

Agilent Automotive Power Window Regulator Testing. Application Note

Keysight Technologies Advanced Measurements and Modeling of Differential Devices

Agilent E6832A W-CDMA Calibration Application

WD Hard Drive Interface Guide

Agilent Television Power Consumption Testing. Application Note

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

Agilent OSS access7 Signaling Meter

TekSmartLab TBX3000A, TSL3000B Datasheet

Agilent OSS Customer-Centric Service Manager

How To Help A Customer With A Network Assessment

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes

QuickSpecs. HP Wireless Keyboard and Mouse. Models

CNE Progress Chart (CNE Certification Requirements and Test Numbers) (updated 18 October 2000)

High speed pattern streaming system based on AXIe s PCIe connectivity and synchronization mechanism

Updating the QIAcube operating software

Agilent P940xA/C Solid State PIN Diode Switches

Cisco IT Data Center and Operations Control Center Tour

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

Brochure More information from

Agilent 4339B/4349B High Resistance Meters

High-Speed Inter Connect (HSIC) Solution

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

R&S SMZ Frequency Multiplier Precise output levels from 50 GHz to 170 GHz

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

Computer Specifications

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

The Real Total Cost of Ownership of Your Test Equipment

Report on Government Information Requests

DATA SHEET. GigaStack GBIC THE CISCO SYSTEMS GIGASTACK GIGABIT INTERFACE CONVERTER (GBIC) IS A VERSATILE, LOW-COST,

Supported Payment Methods

Transcription:

Keysight Technologies Extending the Measurement Plane up to 1 km in Vector Network Analysis Application Brief

Introduction Most network analysis is performed on the test bench or in a production environment. In these situations, all ports of the device-under-test (DUT) are readily available to the vector network analyzer (VNA). In contrast, a variety of applications place a greater distance between the VNA and the DUT. Examples include radar test ranges; in-building, airborne or shipboard RF distribution systems; and satellite communication terminals. Even with the best-performing coaxial cable, high-frequency signals will suffer tremendous attenuation over long spans. The most common solution is to downconvert the stimulus and response signals; however, this introduces mixing products that must be dealt with to ensure accurate measurement results. A new alternative uses the opposite approach. Keysight Technologies new Optical Extenders for Instruments the OXI Series eliminate long runs of coax by converting RF signals to and from optical wavelengths and using single-mode optical fiber that has negligible loss. The OXI solutions enable transmission and reception of signals of up to 50 GHz with very high isolation over distances of up to 1 km. This application brief outlines the problem and the solution, explains how to extend the measurement plane, and describes the OXI modules that enable accurate, cost-effective measurements over long distances. If you believe these products have value for your applications, please call Agilent to discuss the requirements and implementation strategy.

03 Keysight Extending the Measurement Plane up to 1 km in Vector Network Analysis - Application Brief Sketching the problem and the solution To illustrate the problems associated with long runs of coax, consider signal transmission over a 100-ft distance. The first issue is signal loss, which would exceed 25 db even when using the high-performance, low-loss cables designed for test and measurement (Figure 1). The second issue is cost: a 100-ft high-performance cable will cost $10,000 or more. In contrast, single-mode optical fiber can be roughly 10% of this cost when purchased in bulk and typically experiences about 0.2 db of loss per kilometer. Adding a preamplifier will dramatically reduce the loss incurred in the RF-to-optical and optical-to-rf conversions. In addition, noise figure is also improved. Given these advantages, replacing coax with fiber is a very appealing alternative. It is only recently that such optical solutions have been possible at frequencies up to 50 GHz. The enabling technologies are drivers that can modulate an RF signal onto single-mode fiber as an optical signal and detectors and drivers that can convert the received signal back to RF. These components are the result of development work in lightwave communications, which is moving from 10 Gb/s to 40 Gb/s, 100 Gb/s and beyond. 50 Cable Loss 45 40 35 db 30 25 20 100 ft. 125 ft. 15 10 5 0 0 5 10 15 20 GHz Figure 1. In long runs of coaxial cable, signal loss increases with frequency.

04 Keysight Extending the Measurement Plane up to 1 km in Vector Network Analysis - Application Brief Extending the measurement plane PNA-X Local 1 3 4 2 Remote U3020Y03 U3020AY04 U3020AY04 Signal Reference Measurement Test port optical links Figure 2. The standalone local and remote OXI units can be used to place two test ports up to 1 km away from the PNA-X. Designed to support the PNA Series vector network analyzers, the optical port extenders in the OXI Series include two standalone units: a local converter (U3020AY03) and a remote microwave optical module (U3020Y04) that allow optical extension of one or more VNA ports. The remote module provides electrical-to-optical and optical-to-electrical signal conditioning for the local converter, and neither module requires external control. For long-range testing, the local converter accepts the REF, TEST and SRC signals from the PNA and converts them into optical signals that are transmitted to the remote optical module at distances of up to 1 km through a trio of fiber-optic cables (Figure 2). If additional RF output power to the test port is required, an amplifier can be used and the gain backed out of the measurement result. If necessary, attenuation can be applied to the return path to the PNA. One important note: the quality of the optical fiber will have a significant effect on the measurements. Contact Keysight for information regarding the requirements the optical fiber must meet for your application.

05 Keysight Extending the Measurement Plane up to 1 km in Vector Network Analysis - Application Brief Leveraging the versatility of PXIe Figure 3. The family of OXI modules adds greater capability at the remote end when using fiber optic cable for long-distance measurements. In general, PXIe modules deliver the benefits of the standard: a compact, modular and scalable architecture. Looking specifically at the Agilent OXI Series, these modules deliver on the potential to reduce solution cost and complexity. They simply plug into a PXIe chassis and don t require a dedicated instrument controller and you can mix and match modules at any time to address specific measurement needs. Currently, the OXI Series includes six modules. Five are 3U high and occupy two slots each: an RF-to-optical converter transmitter (M9403A), an optical-rf-converter receiver (M9404A), an RF reflectometer (M9408A) and two USB hubs (M9406A and M9407A; see following section). The sixth module is a one-slot 3U preamplifier (M9405A). All are shown in Figure 3. The M9403A transmitter modulates an RF signal onto a 1550-nm single-mode optical signal, and the M9404A receiver demodulates the optical signal and presents the resulting RF signal at its output. Both modules operate from 300 khz to 26.5 GHz (optionally to 50 GHz). These modules take the place of the U3020AY04 at the remote end of the measurement configuration (Figure 4) PNA-X 1 3 Local 4 2 Remote 1: Transmit antenna M9404A receiver M9403A transmitter M9408A reflectometer Remote 2: Receive antenna M9403A transmitter U3020Y03 PXI chassis PXI chassis Signal Reference Measurement Test port optical links Figure 4. This example solution for testing on an antenna range illustrates the flexibility that becomes possible when the PXI-based OXI products are placed in two remote locations.

06 Keysight Extending the Measurement Plane up to 1 km in Vector Network Analysis - Application Brief Figure 5. Performance of a 1.5-km optical link without preamplification. Figure 6. Performance of the same 1.5-km optical link when using the M9405A preamplifier. The M9405A preamplifier covers the same operating frequency range as the converters and delivers 30 db of gain to overcome conversion loss and improve noise figure. Its noise figure performance is 8.5 db to 26.5 GHz and 6 db up to 35 GHz. This capability also is available as an integrated part of the M9403A and M9404A modules. The amplifier can be a useful addition to any remote system because a certain amount of noise is associated with the link in typical electro-optical and opto-electrical pairs. As shown in Figure 5, there is about 34 db of loss and a loss slope of about 0.23 db/ghz and an additional 5 db above 22 GHz in a 1.5-km run. Noise figure is about 40 db. Using the M9405A preamplifier in the link, noise figure drops to 10 or 15 db and loss varies between 0 and 10 db (Figure 6). When the VNA has a configurable test set, adding the M9408A reflectometer module enables full port extension over a full 1-km span. Even at shorter distances, the reflectometer extends the measurement plane and delivers more power to the device and this allows full two-port characterization that isn t practical using coaxial cables. The M9408A has a frequency range of 300 khz to 50 GHz and can also be used as an independent dual coupler. Enabling remote connectivity and control The complete PNA measurement environment including display and control can be operated via USB devices at the remote end of the optical link by adding a one-port (M9406A) or four-port (M9407A) optical-to-usb hub. The hubs provide connections to keyboard, mouse, power sensor and electronic calibration (E-Cal) modules as well as the instrument display (with the optional USB-to-VGA converter). Calibration can be performed from the remote location, as can the power measurements necessary to verify RF power levels at the DUT. A two-pair optical cable supports the transmit and receive paths from the remote and the modules.

07 Keysight Extending the Measurement Plane up to 1 km in Vector Network Analysis - Application Brief Conclusion In applications that include a remote SUT, Keysight s PXIe-based OXI modules eliminate problems such as signal loss and poor noise figure associated with long runs of coaxial cables. These easy-to-configure modules also reduce the number of elements required in the measurement system. In addition, they provide capabilities such as the ability to control the network analyzer from the remote end of the optical connection. If you believe these products have value for your application, please call your Keysight sales representative to discuss the requirements and implementation strategy. Related information Brochure: PNA-X Series microwave network analyzers, publication 5990-4592EN Brochure: PXI Optical Extenders for Instruments, publication 5990-9069EN Data sheet: PXI Optical Extenders for Instruments, publication 5991-0383EN

08 Keysight Extending the Measurement Plane up to 1 km in Vector Network Analysis - Application Brief mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA, AdvancedTCA, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/threeyearwarranty Keysight s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-07-10-14) This information is subject to change without notice. Keysight Technologies, 2013-2014 Published in USA, August 3, 2014 5991-1828EN www.keysight.com